Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | Admitted-Finance |
| 2 | Admitted-Finance COLLEGE CHOWMUHANI JIRANIA WEST TRIPURA | Admitted-Finance |
| 3 | Admitted-Finance AGARTALA TRIPURA W | AGARTALA | TRIPURA | Admitted-Finance |
| 4 | Admitted-Finance SHIBNAGAR AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799001 | Admitted-Finance |
| 5 | Rejected-Technical | Rejected-Technical does not satisfied DNIT Terms and condition |
Tender Value
₹4.0 Cr
EMD Value
₹8.0 L
Closing Date
27 May 2025, 6:00 pmClosed
DGM ED Santirbazar
Office of the DGM, ED Santirbazar
Extension of HTLT line including distribution Transformer in turnkey basis Partial for energisation of 60 nos DTW innovative scheme at different locations of Bagafa and Jolaibari R.D block under the jurisdiction of ED Santirbaza
2025_POWER_61667_1
DNIT No- DGM/ED-STB/2024-25/14
Open Tender
Electrical Works
Turn-key
ED Santirbazar
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹8.0 L
21 Oct 2025
21 May 2025
28 May 2025
21 May 2025
27 May 2025
21 May 2025
21 May 2025 - 26 May 2025
Amount
Supply of the followings- 9.0 mtr.long P.C.C Pole
9.0mtr. Long Steel pole (Swagged type tubular steel poles 410:SP30)
8.0 mtr. Long PCC Pole
Stay set HT complete with 16 mm dia 1.8 mtr stay rod, anchor
Stay set LT complete with 16 mm dia 1.8 mtr stay rod, anchor
Stranded Stay wire 7/2.50mm2
Stay Insulator(HT)
Stay Insulator(LT)
Supply of 0.3 mtr. long 75 X 40 X 40 X 6 mm. MS channel
Supply of 1.2 mtr. long 75 X 40 X 40 X 6 mm. MS channel
Supply of 1.5 mtr. long 65 X 65 X 6 mm. MS angle
Supply of 2.2 mtr long 75X40X40X6mm M.S. Chanel
Supply of 2.5 mtr. long 65 X 65 X 6 mm. MS angle
Supply of 2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel
Supply of 0.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel
Supply of 2.8 mtr. long 75X40X40X6 mm. MS channel
Supply of 2.8 mtr. long 65 X 65 X 6 mm. MS angle
Suppy of 1.5 mtr long 75X40X40X6 mm MS channel
Supply of 1.6 mtr. long 65 X 65 X 6 mm. MS angle
Supply of 3-ph 4 wire "C" Bracket of 65x65x6 mm MS Angle
Supply of 11 KV 320 mm CD Polymer composite Pin Insulator as per the direction of the engineer In- Charge
Supply of 11 KV Polymeric Disc Insulator with fittings, nuts & bolts, washers etc. as required
Supply, testing, erection and commissioning of ACSR Weasel Conductor for jumpering including PG Clamps, bi-metallic connectors, hardware etc as per Drawing & Scope of works as required as per IS.Technical Specification, approved
Supply of 8 SWG GI wire for gaurding/earthing as per technical specifications, approved drawings and scope of works. as required as per IS.
Bi-metalic Lugs 95 sq mm
Bi-metallic Lugs 50 sq. Mm.
70 Sqmm PVC cable as per the technical specifications, IS.
16 Sqmm PVC cable as per the technical specifications, IS.
Supply of fabricated M.S clamp made of 50X6 mm MS flat for fitting fixing of stay set, substation & line erection.
Triple pole (3 phase), 12 KV, 200 Amp. GOS unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer-In-charge.
Triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer's In-charge.
9 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply Nominal Creepage distance 300mm. conforming to ISS:3070/1985 as per the direction of the Engineer's In-charge.
Supply & erection of Wooden Plunk karai wood (L-9", Breath-1.5", thickness-1.5")
LT Shackle Insulators (4X4.5)″ with straps & bolts.
Supply of Nuts & bolts of assorted size.
100 Amps kit kat Cut-out as per Technical specifications.
Danger Plate HT
Danger Plate (LT)
Erection of the followings- 9.0mtr. Long Steel pole
9.0 mtr. Long PCC Pole
8.0 mtr. Long PCC Pole
GI stay set HT 20 SQMM i/c Stay wire (6.0 Kg) , Stay Insulator(1 No), Clamps 50 x 6 mm(4 Nos), Nuts & bolts(2Nos)
GI stay set LT 20 SQMM i/c Stay wire (6.0 Kg) , Stay Insulator(1 No), Clamps 50 x 6 mm(4 Nos), Nuts & bolts(2Nos)
0.3 mtr. long 75 X 40 X 40 X 6 mm. MS channel cross arm on steel tubular pole or PCC pole or RS joist with 1 (one) no. clamp of 50x6 mm. MS flat, nuts and bolts as required. 2.16 Kg @ 69.36/- KG
1.2 mtr. long 75 X 40 X 40 X 6 mm. MS channel cross arm on single steel tubular pole or PCC pole or RS joist including supply with (i)1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.64 Kg @69.36/- KG
1.5 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
2.2 mtr long 75X40X40X6mm M.S. Chanel cross arms on PCC /S.T poles with M.S. Clamps, nuts and Bolts etc as required. 15.84 Kg @69.36/- KG
2.5 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Double steel tubular pole or PCC pole or RS joist structure including supply with (i) 2 (two) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 14.5 Kg @69.36/- KG
2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support and supply with (i) 2 (two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 26.6 kg @69.36/Kg
0.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support and supply with (i) 2 (two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 6.80 kg @69.36/Kg
2.8 mtr. long 75X40X40X6 mm. MS channel bracket for G.O.S & D.O. fuse unit on double steel tubular pole or PCC pole including supply of i) 2(two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 20.16 kg @69.36/Kg
2.8 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
1.5 mtr. long 75 X 40 X40X6 mm. MS Channel cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
1.6 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required 8.70 Kg @69.36/- KG
Erection of 3-ph 4 wire "C" Bracket of 65x65x6 mm MS Angle
Erection of 11 KV 320 mm CD Polymer composite Pin Insulator as per the direction of the engineer In- Charge
Erecion of 11 KV Polymeric Disc Insulator with fittings, nuts & bolts, washers etc. as required
Erection, testing and commissioning of ACSR Weasel Conductor for jumpering including PG Clamps, bi-metallic connectors, hardware etc as per Drawing & Scope of works as required as per IS.Technical Specification, approved
Erection, testing and commissioning of 8 SWG GI wire for gaurding/earthing as per technical specifications, approved drawings and scope of works. as required as per IS.
Erection of protective Guard/ Cross lacing for 11 KV line GI wire 8/10 SWG as per the technical specification
Providing pipe earthing with supply of 2.5 mtr long 40 mm Dia GI pipe (Jindal/TATA make) including supply of salt & charcoal(Salt 60 Kg, Charcoal 55Kg) along with excavation, refilling with alternative layer of salt & charcoal etc as required including connectivity with Transformer Body, nutral & Lightning arrestor as per direction of the EIC.
Providing Coil earthing as per REC specification.
Triple pole (3 phase), 12 KV, 200 Amp. GOS unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer-In-charge.
Triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit (Porcelin type) for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with fixing of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR. as per the direction of the Engineer's In-charge.
9 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply Nominal Creepage distance 300mm. conforming to ISS:3070/1985 as per the direction of the Engineer's In-charge.
Commissioning of AI. wound three Phase ,63KVA, 50 Hz AC, out door type 11/0.433KV, distribution transformer complete with necessary accessories and Transformer oil conforming to relevant ISS and required connection by ACSR from 11 KV line to Transformer via G.O.S & D.O.F fixing with of 2 ( two ) Nos strain Screw and nuts & bolts as reqd. as per the direction of Engineer-in-charge and approved drawing.
Danger Plate HT
Danger Plate (LT)
Grouting with CC of Ratio 1:2:4 (1 Cement(Cement Concrete, A=600x600x630 -(3.14x(165/2)Sqx630)=220108443.8Sqmm, B=3.14x(420/2)Sqx 457-(3.14x(165/2)Sqx457)=53516785.38Sqmm, A+B =273624229.2Sqmm=0.273 Cum)):2 Rover Sand: 4 Jhama Brick Aggregate of 20 mm, normal Size) including supply of Cement sand and brick aggregate complete with excavation, refilling of earth ramming alongwith centering shuttering as required @0.273 cum per Steel Tubuler Pole as per TSECL Specification etc.
LT Shackle Insulators (4X4.5)″ with straps & bolts.
Providing of three phase service connection laying of PVC cable from nearby electrical Pole to the premises up to 35 Meter in length supported by GI-wire, Reel insulator i/c fitting, fixing of Energy Meter (Department supply which shall be collected from respective Electrical Division) as required as per the direction of the Engineer In-charge.
Providing of Substation protective Fencing of size 2X3 mtr and height 1.5 mtr as per engineering requirement by 10 nos. MS angle post(50X50X6 mm) of height 2 mtr, horizontal bar 2X3 mtr. And 2X2 mtr. Of MS Angle(35X35X5 mm)
Carriage of 9.0mtrs. Long PCC poles from Bagafa ESD Store yard to work site by Mechanical transport etc. as required including loading / Unloading & stacking etc. as reqd. upto the lead range of 25.0Km
Carriage of 9.0mtrs. Long Steel poles from Bagafa ESD Store yard to work site by Mechanical transport etc. as required including loading / Unloading & stacking etc. as reqd. upto the lead range of 25.0Km
Carriage of 8.0mtrs. Long PCC poles from Bagafa ESD Store yard to work site by Mechanical transport etc. as required including loading / Unloading & stacking etc. as reqd. upto the lead range of 25.0Km
Carriage of 11/0.430, 3-Phase 63KVA by mechanical transport from site/ store/ workshop to working site vis-a-vis including loading, unloading and placing on base, as required. Beyond 50KM
Carriage of all line materials from Bagafa-ESD site store to work site by Mechanical transport etc. as required including loading /Unloading & stacking etc. as reqd upto the lead range of 25.0Km
ADHIR DEBNATH (BID ID -176897)
RANJAN BHATTACHARJEE (BID ID -176499)
M/s Bhattacharjee Construction (BID ID -177040)
stage.html
html • 0.04 MB
technical_62734.pdf
techsummary_62734.pdf
finance_62734.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.44 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tendernotice_2.pdf
PDF • 5.16 MB
BOQ_62734.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .