Loading…
Loading…
Tender Value
₹24.9 L
EMD Value
₹49,897
Closing Date
28 Sept 2026, 5:30 pm6d left
Karnataka Power Corporation Limited
Manjunath H S
Retrofitting, Testing and Commissioning of ABB make 12kV,1250A, 40KA, HT Breakers with cradle solution in place of Jyothi make HT breaker at control room SWGR and old HT Breaker of stacker/Reclaimer-3 at CHP-1 RTPS
KPCL/2026-27/PS/WORK_INDENT4788
KPCL/2026-27/PS/WORK_INDENT4788
Open
Power stations
Two Tender Document System(Two Cover)
KPCL Executive Engineer CHPE2 Office RTPS Raichur
4 documents required · 0 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
Proposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)
The intending bidder should have satisfactorily as a prime contractor, at least one similar work such as supply and Commissioning of HT Breakers of value not less than Rs 14.72 Lakhs in the last five years (2021-22, 2022-23, 2023-24, 2024-25 and 2025-26) in any Power stations/Process Industries. As a proof of this, the bidder should upload a work order and corresponding work done certificate issued by the competent authority. (Work done of previous years shall be given weight of 10% per year to bring them to the present price level of the financial year)
The intending bidder shall be OEM or Authorized dealer of ABB make HT breakers or class-1 or above electrical contractor having experience of supply, Erection & Commissioning of HT Breakers.As a proof of this, bidder should upload relevant documents and valid electrical license issued by competent authority of Govt of Karnataka shall be uploaded in case of Authorised dealer/Electrical Contractor.
The intending bidder in his name should have achieved an average annual financial turnover of Rs. 29.44 lakhs in any two financial years during the last five years (2021-22, 2022-23, 2023-24, 2024-25 and 2025-26). As a proof of this, the bidder shall upload the certified copy of the Profit and Loss or Turnover certificate duly certified by the chartered Accountant. (financial turnover of previous years shall be given weight of 10% per year to bring them to the present price level of financial year).
₹630
₹49,897
11 Sept 2026
11 Sept 2026
30 Sept 2026
23 Sept 2026
25 Sept 2026
Retrofitting, Testing and Commissioning of ABB make 12kV,1250A, 40KA, HT Breakers with cradle solution in place of Jyothi make HT breaker at control room SWGR and old HT Breaker of stacker/Reclaimer-3 at CHP-1 RTPS
Supply of VD4 Breaker with Cradle Salution ( Cassette type)
Rating: 12KV,1240A , for feeder protection.at Control Room SWGR with complete Accessories .
Supply of VD4 HPA Breaker
Rating: 12KV,1240A , for feeder protection at Stacker/Reclaimer-3 with complete Accesseries.
Installation of VD4 Breaker with cradle solution ( Cassette type)Rating: 12KV,1240A , at control Room SWGR and Stacker Reclaimer-3 complete work(Door Modification,Busbar modification and contorl wirin...
Supply,of REF 615 with Relay Metering Door with pre wired plate CT PT MFM,Ammeter,Master Trip Relay TCS relay at stacker Reclaimer-3
Installation of REF 615 with Relay Metering Door with pre wired plate CT PT MFM,Ammeter,Master Trip Relay TCS relay at stacker Reclaimer-4
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BID_DOCUMENT-2.docx
Tender Document • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .