Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST AMOUNT QUOTED BY SHAJIMON S | |
| 2 | L2₹2.1 L+₹6,299.21 (3.03%)Rejected-AOC | L2 | Rejected-AOC LOWEST AMOUNT QUOTED BY SHAJIMON S |
Tender Value
₹2.1 L
EMD Value
₹5,249
Closing Date
12 Feb 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Assistant Executive Engineer LSGD Division Idukki Painavu
GENERAL-Murikkassery Schoolpady Bhagam DWSS-Electrification of Murikkassery Schoolpady Bhagam DWSS in Vathikudy GP under Idukki Jilla Panchayath area- DP work.-General Electrical Work-TENDER
2024_LSGD_652023_8
19/T/AEE/LIDEW/IDK/2023-2024
Open Tender
Electrical Works
Item Rate
120 days
VATHIKUDY
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
₹5,249
Yes
17 Jul 2025
1 Feb 2024
13 Feb 2024
1 Feb 2024
12 Feb 2024
1 Feb 2024
1 Feb 2024 - 12 Feb 2024
Amount
Electrification
OD323059/2023-2024:Supply, conveyance, testing and commissioning of 3 phase 15 kw /20 HP open well Motor pump set working at 50 Hz 415 V AC supply having a head range of 34m -124m and discharge range of 510 lpm - 180 lpm respectively and having a delivery size of 50mm conforming to US capable standard accessories as per the direction of department staff as the site [KSP/Kirlosker, Texmo, CRI of approved equivalent make) with pannel.
OD323060/2023-2024: Providing HDPE PE 63 grade P 6 pipes complete with fixing and jointing the pipe with coupling or any other fittings including the cost of fittings and testing of joints etc. complete as per direction of Engineer in charge 50 mm dia. 10 hgf/cm2
90.6.6.5:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.10 sq mm
OD323061/2023-2024:Supply and laying of 20mm or nearest size Nylon rope
OD323062/2023-2024:Providing and fixing gun metal non-return valve of approved quality (screwed end) : 50mm nominal bore Vertical
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
OD323072/2023-2024:Fabrication, supply, conveyance and installation of angle iron frame work for wall mounting panel board using suitable size angle iron cut and welded to shape including painting with front sheet of angle iron panel board including all accessories etc. as required in the size of 180x 90cm
2.13.3:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
90.11.1.12:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
90.14.24.8:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.10 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
1.34:Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
OD323066/2023-2024:Supply and fixing 100A, backlite fuse base with HRC fuse link in the existing meter board and giving connection etc.
OD323067/2023-2024:Supply and fixing 100A, 415V, 2 way neutral link mounted on DMC/SMC base in the existing meter board and giving connection etc.
OD323068/2023-2024:Supply and installation of dust and vermin proof, wall mounting, Sintex meter box of size 505x24x145mm suitable for fixing KSEB meter, fuse unit etc., hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. (GSMB-5628)
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD323069/2023-2024:Supply, conveyance , fixing GI pipe of 2" dia for supporting the pump set including all suitable accessories as required.
OD323070/2023-2024:Supplying Bolt & Nut of sizes as required
OD323098/2023-2024:Supplying and providing clamp set 35 mm CI
OD323100/2023-2024:Cable tie 250mm (P)SL
OD361488/2023-2024:Providing GI pipe earthing with all suitable accessories as per IS 3043 as required
OD323099/2023-2024:GI Bend 50mm SP
OD323097/2023-2024:Supply and fixing 5/18 nuts & bolts for flang fitting
OD323166/2023-2024:Supply and providing Nut & Bolt 2"x½"
Justin George
Bidder Name
Justin George
SHAJIMON S
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1005230.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .