Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 CrAdmitted-Finance | ₹9.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.2 Cr+₹13.5 L (1.50%)Admitted-Finance KANNUR | KERALA | 670001 | ₹9.2 Cr+₹13.5 L (1.50%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY L2 | KAVUMKAL ROAD BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00SITE CLEARANCE | |||||
| 1.00 | 2.2:Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area | 0.14 | Hectare | 56,840 ₹8,014.44 Lowest | 61,612.86 ₹8,687.41 |
| 1.00 | 3.19.2:Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | 2,114.1 | cum | 78 ₹1,64,899.8 | 36.44 ₹77,037.8 Lowest |
| 2.00GROUND IMPROVEMENT AND EMBANKMENT | |||||
| 2.00 | OD92105/2024-2025:Based on MoRTH 15.6 - Laying of a PP Non Woven Geotextile Needle Punched and Mechanically Bonded Non-Woven Geotextile between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching. | 13,929.57 | sqm | 230 ₹32,03,801.1 | 225.22 ₹31,37,217.76 Lowest |
| 2.00 | OD92369/2024-2025:Ground improvement work by spreading 20 mm coarse aggregate for a thickness of 20 cm and compacting with surface vibrator, inserting geo grid at the middle level which will be paid separately. | 2,582.33 | cum | 3,700 ₹95,54,635.8 Lowest | 3,895.26 ₹1,00,58,862.34 |
| 2.00 | OD92102/2024-2025:Based on DAR item no. 26.18.1 - Supplying and laying high strength and high stiff strip bonded geo grids (grade I) with low creep characteristics and stress strain characteristics to mobilise desired tension at 5% strain - geo grid made from polyester (PET) with high quality coating like LDPE or equivalent - with minimum long term design strength at 30 degree Celsius for 120 year designed life of 57kN/m, minimum roll width 4.5m - soil reinforcement / basal reinforcement as per MORTH 3100 and IRC 113-2013 .
Ultimate tensile strength- 100 kN/m | 12,911.67 | sqm | 310 ₹40,02,617.7 | 297.86 ₹38,45,870.03 Lowest |
| 2.00 | OD92452/2024-2025:Based on MoRTH item 55.32: Providing and laying geocell of size 150X356X200 in subgrade layer all complete as per IRC SP 59-2019 and technical specification 700 with aggregate as directed by Engineer. | 12,387.06 | sqm | 1,270 ₹1,57,31,566.2 Lowest | 1,449.05 ₹1,79,49,469.29 |
| 2.00 | OD174801/2025-2026:Based on MORTH item 3.16: Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2. | 15,886.68 | cum | 1,370 ₹2,17,64,750.23 | 1,187.98 ₹1,88,73,056.92 Lowest |
| 2.01 | OD103976/2024-2025:Based on item no. 26.17 of DAR - Supplying & laying of drainage composite as capillary cut off - having thermobonding a draining core - HDPE geonet comprises of two sets of parallel overlayed ribs integrally connected to have a rhomboidal shape with a polyethylene film and a nonwoven geotextile having mass per unit area 130 gsm and tensile strength of 8.0 kN/m that
will be working as separation or protecting layer, geocomposite having in plane flow capacity of 0.7 L / (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure and tensile strength 2069SUB HEAD : 26- NEW TECHNOLOGIES AND MATERIALS of 13.5 kN/m , with mass per unit area of 830 gsm, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete and as directed by Engineer - In - Charge. | 9,818.82 | sqm | 1,030 ₹1,01,13,384.6 Lowest | 1,190.79 ₹1,16,92,152.67 |
Tender Value
₹8.6 Cr
EMD Value
₹2 L
Closing Date
27 Oct 2025, 3:00 pmClosed
Project Director, PMU-KRFB, TVM
The Project Director, Kerala Road Fund Board, Project Management Unit, Ground Floor, BSNL Office Building at CGM(O), Doorsanchar Bhavan, PMG Junction Trivandrum-695033
Construction
2025_KRFB_809338_1
PWD/KR/TR/13000/2024_5_1_1/1
Open Tender
Civil Works - Roads
Item Rate
365 days
Alappuzha
Please refer Tender documents.
8 documents required · 8 mandatory
₹13,010
Yes
₹2 L
Yes
19 Mar 2026
14 Oct 2025
29 Oct 2025
14 Oct 2025
27 Oct 2025
14 Oct 2025
Amount
SITE CLEARANCE
2.2:Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area
3.19.2:Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.
GROUND IMPROVEMENT AND EMBANKMENT
OD92105/2024-2025:Based on MoRTH 15.6 - Laying of a PP Non Woven Geotextile Needle Punched and Mechanically Bonded Non-Woven Geotextile between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.
OD92369/2024-2025:Ground improvement work by spreading 20 mm coarse aggregate for a thickness of 20 cm and compacting with surface vibrator, inserting geo grid at the middle level which will be paid separately.
OD92102/2024-2025:Based on DAR item no. 26.18.1 - Supplying and laying high strength and high stiff strip bonded geo grids (grade I) with low creep characteristics and stress strain characteristics to mobilise desired tension at 5% strain - geo grid made from polyester (PET) with high quality coating like LDPE or equivalent - with minimum long term design strength at 30 degree Celsius for 120 year designed life of 57kN/m, minimum roll width 4.5m - soil reinforcement / basal reinforcement as per MORTH 3100 and IRC 113-2013 . Ultimate tensile strength- 100 kN/m
OD92452/2024-2025:Based on MoRTH item 55.32: Providing and laying geocell of size 150X356X200 in subgrade layer all complete as per IRC SP 59-2019 and technical specification 700 with aggregate as directed by Engineer.
OD174801/2025-2026:Based on MORTH item 3.16: Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
OD103976/2024-2025:Based on item no. 26.17 of DAR - Supplying & laying of drainage composite as capillary cut off - having thermobonding a draining core - HDPE geonet comprises of two sets of parallel overlayed ribs integrally connected to have a rhomboidal shape with a polyethylene film and a nonwoven geotextile having mass per unit area 130 gsm and tensile strength of 8.0 kN/m that will be working as separation or protecting layer, geocomposite having in plane flow capacity of 0.7 L / (m.s) at hydraulic gradient of 1.0 & 20 kPa pressure and tensile strength 2069SUB HEAD : 26- NEW TECHNOLOGIES AND MATERIALS of 13.5 kN/m , with mass per unit area of 830 gsm, at easily accessible location including top and bottom, with all leads and lifts, manpower and machinery, materials, labour etc. complete and as directed by Engineer - In - Charge.
OD174900/2025-2026:Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2
OD93786/2024-2025:Laying of a coir geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.
PAVEMENT
4.1.B.1:Construction of granular sub-base by providing graded material, spreading in uniform layers with a motor grader on a prepared surface, mixing by mix in-place method with rotavator at OMC, and compacting with a vibratory roller to achieve the desired density, complete as per clause 401. Grading-V - For sub-base cum drainage layer - Mix in Place Method
4.12:Providing, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
5.1.a:Providing and applying primer coat with bitumen emulsion ( SS) on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 - 1.0 kg/sqm using mechanical means.
5.2.a:Providing and applying tack coat with bitumen emulsion( RS) using emulsion pressure distributor at the rate of 0.20 - 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
OD103882/2024-2025:Based on MoRTH item 5.7.2 : Providing, laying and rolling of close-graded premix surfacing material of 40 mm thickness composed of 13.2 mm to 0.09 mm (Type-B) aggregates using viscosity grade bitumen ( VG - 30) to the required line, grade, and level to serve as wearing course on a previously prepared base, including mixing in a suitable HMP of appropriate capacity not less than 75 tonnes/hour., laying and rolling with a Smooth wheeled roller 8-10 tonne capacity, and finishing to the required level and grade.
55.16:Providing and fixing guard post Providing and fixing guard post of size 200mmx200mm, 1400mm long, 800mm above ground level and 600mm below GL. casted in M20 Grade concrete reinforced with 4 nos of 8mm dia longitudinal bars and 6mm dia stirrups @ 100mm c/c, firmly fixed in position by means of foundation of size 0.5mx0.5mx0.7m in M15 grade concrete below ground level including painting 2 coats on exposed surface with synthetic enamel paint in alternate white & black band 20cm wide
BOX CULVERT
3.13.1.B:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work. Ordinary soil - Mechanical Means - (Depth upto 3 m)
15.9:Construction of dry rubble flooring at cross drainage works for relatively less important works.
12.8.A:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications PCC Grade M15 ( Without formwork)
OD56582/2025-2026:Supplying and stacking Coconut piles 6.0m long
OD56597/2025-2026:Driving down coconut pile to lines and levels through soft to medium clay soil strata including all hire charges and labour and all other appliances necessary for pile driving down after pointing the bottom end. Details for one post of 6m long 15 numbers per day 6X15=90m Details for 90m length
12.8.E.2.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. RCC Grade M25 - With Batching Plant, Transit Mixer and Concrete Pump
12.40:Supply, Fitting and Placing un- coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications
8.8:Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
PIPE CULVERT
12.1.5.B:Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Marshy Soil Depth upto 3 m (Excluding Shoring) - Mechanical Means
15.9:Construction of dry rubble flooring at cross drainage works for relatively less important works.
12.8.A.1:Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15
9.2.A:Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first-class bedding of granular material in a single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in headwalls and parapets. 1000 mm dia
15.4.A:Providing and laying Pitching on slopes laid over prepared filter media including boulder Stone/Boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications
TRAFFIC SIGNS, ROAD MARKINGS AND OTHER APPURTENANCES
8.4.2:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. 60 cm equilateral triangle
8.4.4:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting vide clause 801.3.3 fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. 80 mm x 60 mm rectangular
8.13:Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, the thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform, and free from streaks and holes.
8.35:Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3 Road Markers/Road Stud with Lense Reflector :-
8.4.12:Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 7years warranty manufactured as per IRC :67 made of Type IV micro prismatic grade sheeting fixed over aluminum sheeting, 2 mm thick/aluminum composite material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc. 50cmx 60 cm rectangular (Single chevron etc.)
8.15:Supplying and installation of delineator (Roadway indicators) posts 80- 100cm high above ground level, pained black, and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorized panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)
8.6:Providing and fixing of direction and place identification retro-reflectorised sign with 7 years warranty manufactured as per IRC :67 High Intensity Micro Prismatic (Type IV) grade sheeting fixed over aluminum sheeting, 2 mm thick/aluminum composite material sheeting 4 mm thick with an area exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on suitably designed GI pipe pole not less than 50mm NB , 2 Nos. confirming to IS 1239, firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.
55.10.1:Providing and erecting retro-reflectorised Object Hazard Marker 300mm x 900mm Providing and erecting retro-reflectorised Object Hazard Marker sign with 07 years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09 micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick / aluminium composit material sheeting 4 mm thick with suitable back support frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly fixed 30cm above ground level by means of properly designed foundation with M 15 grade cement concrete 30cmx30x45cm, 45cm below ground level including painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as per approved drawing and clause 801.300 mm x 900 mm
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY (BID ID -2410267)
Bidder Name
KAVUMKAL ROAD BUILDERS
THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY
stage.html
html • 0.03 MB
technical_1350212.pdf
techsummary_1350212.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.16 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
Requisitionfore-payment.pdf
Additional Documents • 0.10 MB
SBD.pdf
Tender Documents • 2.04 MB
BOQ_1350212.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .