Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹42.0 L+₹3.8 L (9.82%)Rejected-AOC OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected being higher bidder | |
| 3 | L3₹44.5 L+₹6.3 L (16.4%)Rejected-AOC 37 SUBHASH NAGAR AIR FORCE JODHPUR 342 008 | JODHPUR | JODHPUR | RAJASTHAN | 342008 | L3 | Rejected-AOC Rejected being higher bidder |
Tender Value
₹48.5 L
EMD Value
₹97,100
Closing Date
1 Oct 2024, 6:00 pmClosed
GE (AF) Jodhpur
GE AF JODHPUR
SPECIAL REPAIRS TO BLDG NO P 53 MT YARDS GARAGES STORES WITH ALLIED WORKS AT SUAT AF STN JODHPUR
2024_MES_670520_1
8676/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹97,100
Yes
15 Oct 2024
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
17 Sept 2024
Amount
Demolition of stone/ boulder masonry, built in cement/ lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed by the Engineer-in-Charge.
Dismantling particle boardings any escription fixed in any position with screws complete all as specified & directed.
Demolition of Precast Concrete Block walling, build in cement mortar including all quoins, arches, pillars, ashlars facings, dressed stonework and precast concrete articles and removing demolished material to 1.0 km lead complete all as specified & directed.
M&L for walling of squared rubble stone, regular coursed, well bonded, bedded and solidly hearted, built in in cement mortar 1:6, complete al as specified.
M&L for Pre-cast cement concrete type B1 1:2:4 using (20 mm graded stone aggregate) as in block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified & directed.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below/above ground level) including floor finishes complete all as specified & directed by the Engineer-in-Charge.
Material & labour for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in levelling course finished even and fair for laying floor finishes etc complete all as specified & directed by the Engineer-in-Charge.
M&L for coloured vitrified ceramic tiles 10mm thick of approved colour and 600x600 mm in size (square/rectangular) polished in floors etc set jointed in cement slurry and pointed in white or coloured cement slurry and pointed in white or coloured cement to match the colour/shades of tiles over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for 10 to 12 mm thick vitrified unglazed and unpolished, scratch resistant, matt finished coloured tiles (square/rectangular) of size not less than 300mm x 300mm as in parking/hardstanding etc laid over and including 15 mm thick screed bed in CM 1:4, set, jointed in cement slurry and pointed in white or coloured cement to match the colour/shades of tiles complete all as specified and directed.
Taking down cement or cement lime plaster work any description from brick or stone wall/ ceiling etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified & directed by the Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats exterior weather proof water base emulsion paint, over a coat of chalk whiting complete all as specified & directed by the Engineer-in-Charge.
M&L for rendering 15 mm thick in CM 1:4 on stone masonry surface including finish surface fair & even complete all as specified & directed by the Engineer-in-Charge.
M&L for preparation of old surfaces including complete removal of old existing treatment of wall surfaces and applying one coat of white cement base wall care putty 2 mm thick on walls finished even and smooth with sand paper and applying two coats of Oil bound distemper complete all as specified and directed.
Taking down chowkhats or frames n exc 1.5 sq. m complete all as specified and directed.
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m complete all as specified and directed.
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawl strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.
Supply & fixing 125mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and as directed.
Supply & fixing stainless steel handles of size 125mm, complete all as specified and directed.
Supply & fixing 300 mm long stainless steel sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet complete all as specified and directed.
Supply & fixing floor door stopper of brass body and tongue with hard drawn steel spring with overall length of cover plate 150 mm, fixed in floor complete all as specified and as directed.
Supply & fixing stainless steel barrel tower bolt of size 150mm fixed in positions complete all as specified & directed by the Engineer-in-Charge.
S&F in repairs, Aluminium door closer hydraulically regulated, designation No 1, universal type suitable for door shutters upto 700 mm in width and of wt not more than 35 kg complete all as specified and as directed.
Supply and fixing 12 mm thick toughned glass in square or rectangular shape, area exc 1.50 Sqm but n exc 4.00 Sqm for the designer door, including stainless steel bracket and other suitable accessories to fix door on floor spring and top piovt with 2 Nos stainless steel door handle of length 300 mm and 100 mm size mortice lock for each door complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing brass mortice lock handels of 4 Lever vertical type, size 175 mm for doors all as specifed and directed by Engineer-in-Charge.
M&L for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.) hinge type B-21 100mm long (2 Nos.) suitable handle (1 No.) complete all as specified and directed.
S&F 5.5 mm thick sheet glass ground or obscured or frosted on one side as approved and glazing with oil putty/ glazing clips in square not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F vitreous china wash down water closet pan, white (Pedestal pattern) including PVC seat cover, closed pattern with flat bottom, and cover and MS Chromium Plated or aluminised hinging device complete all as specified and directed.
S&F vitreous china WHB white, flat back, size 550 x 400mm excluding taps, chain and plug and porcelain stopper but including brackets, waste pipe and waste coupling and Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed of 15 mm bore complete all as specified and directed.
S&F Salt-glazed stoneware gully traps, square or round mouthed, type `P' Size of gully traps 125x100 in mm complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F 20 mm bore GI steel tubing medium grade with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F 15 mm bore GI steel tubing medium grade with all fitting and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
S&F in repairs bib tap chromium plated,fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of 15 mm bore.
S&F in repair stop valves chromium plated,fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union and fixed, 15 mm bore complete all as specified and directed.
S&F in repair brass chromium plated shower rose 125 mm size complete all as specified and directed.
S&F in PVC connection 15mm size with PTMT nuts 450mm long complete all as specified and directed.
Supply and fixing in repairs PVC valveless syphonic action type flushing cistern low level 10ltrs capacity white, fixed with new brackets complete all as specifed and directed.
Supply and fixing in repairs CP waste coupling 40/32 mm dia for steel sink / urinal with long shank and fly nuts etc complete all as specified and directed.
Supply & fixing PVC (SWR), 75mm dia of floor trap, with grating including jointing with solvent cement inculding cutting out wall /concrete and finishing of surface to match existing surface complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs PVC Flexible waste pipe 40 mm dia with socket for steel sink upto floor level and length not less than 1.00 meter complete all as specified and directed.
S&F in repairs Health faucet ( ABS Body) mild steel chromium plated suitable foir 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F in repairs soap dish vitreous china soap tray embedded in the wall all as specifed and directed.
S&F Tubler Towel rail 20 mm dia brass chromium plated including brackets 600 mm long complete all as specified and directed.
Supply and fixing in repairs of fancy type pillar taps brass, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks & fly nuts for iron pipe of 15mm bore complete all as specified and directed.
Supply and fixing rotational moulded polyethylene water storage tank of capacity 500 ltrs (Cylindrical vertical with closed top), three layer construction, ISI marked hoisted & fixed in position including GI light grade, over flow pipe 450mm and waste pipe 600mm long with all fitting etc. of 20 mm dia including dismantling/taking out of old water tank of having capacity of etc 250 Ltr but not exc 500 Ltr & removing to site etc complete all as specified and as directed.
Supply and fixing in repairs for 20 mm bore of Ball valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe (wt not less then for 210 gms) complete all as specified and directed.
S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogeneous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. (Note:- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly.)
S&F factory made solid PVC moulded door shutters 28 to 30 mm thick (stile), with 2, 4 or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face, with wood free EPS, fixing in frame at site as per specification & drawing complete all as specified and directed.
S&F Aluminium powder coated aluminium frame for doors, windows, ventilators, partion wall with one or more rebates including joining cleat for fixing etc completet all as specified. (Thickness of powder coating shall not be less than 50 micron.)
S&F aluminium powder coated door shutters of any colour (Thickness of powder coating not less than 50 micron), aluminium sections weighing 0.55kg/m incl necessary joining cleat glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, aluminium snap beading screws complete all as specified and directed.
S&F 5 mm thick froasted glass panes and glazing with oil putty or fix in aluminium door / widnow complete all as specified and directed.
S&F in repairs double action floor spring hydraulically regulated made up of of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
S&F Anodised aluminium snap grid frame work (600mm X 600 mm) for false ceiling complete all as specified and directed.
S&F 8 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 x 600mm grid for Exposed metal frame ceiling complete all as specified and directed. (Frame work for ceiling shall be measured and paid separately)
M&L for 100 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:2:4 type B2 using 40mm graded stone aggregate as in flooring laid in alternate bays complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in plinth protection complete all as specified and directed.
M&L for collapsible steel gates of channel thickness 3mm, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
Demolition of Concrete Concrete of any description and in any position not otherwise specifically provided for and removing demolished material upto 1000 m complete all as specified and directed.
Demolition of Stone slabs and tiles laid in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over and including cement screed 15mm thick in cement mortor 1:3 jointed with grey cement slury mixed with pigment to match the shade of the slab including rubbing and polishing all as specified and directed.
Taking down old existing roof treatment (APP membrane) and removing debris outside MD land complete all as specified and as directed.
Demolition of cement concrete of any type description and in any position including removing debris outside MD land complete all as specified and as directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and directed.
M&L for brushing neat cement slurry with 3kg of cement per Sqm complete all as specified and directed.
M&L for min 40 mm thick cement concrete 1:2:4 type B-O m (12.5 mm graded stone aggregate) in padding finishing surface of concrete topping even and smooth without using extra cement complete all as specified.
M&L for 10mm thick plastering in CM 1:3 on green concrete roof surfaces with water proofing compound @ 3% by weight of cement, surface finished even and smooth without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid separately.
Supply only integral water proofing compound ISI Marked all as specified and as directed.
M&L for preparation of concrete surfaces for applying bitumenous primer (conforming to IS : 3384-1965) @ 0.40 Kg/sqm complete all as specified and directed by Engineer-in-Charge.
M&L for applying evenly a tack coat of industrial bitumen grade of 85/25 at the rate of 1.2 Kg per sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane) complete all as specified and as directed by Engineer-in Charge. (Note :- Each coat will be measured and paid seperately.)
M&L for applying APP based polymeric membrane minimum weighing not less than 3 kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application and finally finished with aluminium paint @ 0.20 Ltr per sqm complete all as specified and as directed by Engineer-in-Charge.
Dismantling of old unserviceable, rusted, broken (corrugated/semi corrugated, etc.) CGI/AC/ Fibre glass sheets in ridge and roof coverings complete all as specified & directed.
Supply & fix Pre-painted galvalume GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion concrete, brick work, masonry, etc. and making good disturbed ground complete all as specified and as directed.
S&F in steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St. 240 complete all as specified and directed.
Material & labour for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over and including coat of red oxide primer complete all as specified & directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion concrete, brick work, masonry, etc. and making good disturbed ground complete all as specified and as directed.
Excavation in post holes ( or similar holes) each n exc 0.5 cum each getting out, returning, filling in and ramming earth or broken rubble mixed with earh around , in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surfaces in soft/loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2(40mm graded aggregate) in foundation, sub base, filling and mass concrete complete all as specified and as directed.
S&F angles in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F in repairs galvanized 2 strand steel barbed wire 2.20 to 2.24 mm dia barbed with 2mm dia barbs @ 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed.
Supply & fix galvanised steel punched type concertina coil of 1050 mm dia (dia of coil when unstretched) (weight of the concertina coil not less than 14 Kg and opening length should be 8 m) & fixed to angle iron post/struts with 3.15mm dia GI wire complete all as specified & as directed.
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
Taking down MCB DB any type and any capacity all as specified and directed by Engineer-in-Charge.
Taking down Sub main wiring any type any size and making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light point/fan point controlled by one switch 5 amp one way using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No drawn through and including concealed PVC conduit of 20 mm bore with accessories in wall floor etc ISI mark including sunken type metal boxes covered with 3 mm thick plastic laminated sheet cover suitable for modular switches/sockets and fan regulators including modular plates etc, including PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly , including making good of disturbed surface of cement plaster, whitewash/ distempered match with original colour complete all as specified and directed by Engineer-in-charge.
All as per Item No 88 above but for 5 amp socket on same board.
All as per Item No 88 above but for 5 amp socket on independent board.
All as per Item No 88 above but with 2.5 Sq mm cable for Independent one 6 pin 5/15 Amps socket outlet In and including 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS-694 FRLS cable for continuous earth wire.
Spply and fix in repairs modular switches 6 amps single pole one way complete all as specified and directed.
Supply and fix in repairs modular socketes outlet 6 amps 5 pin complete all as specified and directed.
Supply and fix in repairs modular switches 16 A single pole one way complete all as specified and directed.
Supply and fix in repairs modular socket 6/16 A 3 pin combined with shuttered complete all as specified and directed.
Supply and fix in repairs modular step fan speed regulator 5 steps complete all as specified and directed.
S&F in repair ceiling rose surface bakelite 65 x 20mm white coloured 3 terminals ISI marked complete all as specified and directed.
S&F energy efficient recessed mounted LED 36W luminaire suitable for 2'x2' grid ceiling with flat diffuser and lumen output of 3600 lumens colour temprature 3300K to 5300K having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required complete all as specified and directed.
Taking down and refixing energy efficient recessed mounted LED 36W luminaire complete all as directed by Engr-in-Charge.
Taking down and refixing LED 4 feet tube light fitting 1x 18W complete all as directed by Engr-in-Charge.
Taking down and refixing ceiling fans/exhaust fans of any sizes complete all as directed by Engr-in-Charge.
Taking down and refixing Split Air conditioners of any capacity including connected voltage stabilizers complete including making good to disturbed surface to match with existing surface without extra cost all as directed by the EIC.
Taking down and refixing of multisensors heat and smoke detector in ceiling including connection and numbering, complete testing on completion as required at site as directed by Engr-in-Charge.
Taking down and refixing of manual call point including making necessary connection including testing on completion at site as directed by Engr-in-Charge.
Taking down and refixing wall mounted hooter including makking neccessary connection including testing on completion at site as directed by Engr-in-Charge.
Taking down and refixing existing fire alarm panel including installation, testing and commissioning complete all as directed by Engr-in-Charge.
Supply and Fixing of multisenser Heat Detector & smoke detector addressable type suitable for Automatic Fire Detection & Alarm System complete connection including testing on completion all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs copper tube (ISI marked) of size 5/8" dia for any capacity of split type AC complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs copper tube (ISI marked) of size 1/4" dia for any capacity of split type AC complete all as specified and directed by the Engineer-in-Charge.
Material and Labour in repairs for fire resistance, elastomeric Nitrile rubber tubing (NBR) for pipe insulation thickness 10mm of size 5/8" dia of split type AC's any capacity complete all as specified and directed by the Engineer-in-Charge.
Material and Labour in repairs for fire resistance, elastomeric Nitrile rubber tubing (NBR) for pipe insulation thickness 10mm of size 1/4" dia of split type AC's any capacity complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repairs flexible drain pipe (PVC BRAIDED hose pipe) of size 15mm dia for split type AC any capacity and make complete all as specified and directed the Engr-in-Charge.
M&L for submain wiring with two runs of single core 6 sqmm FRLS PVC insulated copper cable 1100 volts grade multistranded, unsheathed conductor drawn through and including PVC casing and caping and all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuty conductor connected to common earth dolly complete complete all as specified and directed. Note : Two runs of main wire and one run of earth wire & one run of casing caping shall be measured and paid as one length.
Material and labour for submain wiring with 2 single core PVC insulated multi stranded copper conductor cable FRLS of size 1.5 sqmm 1100 volt grade (ISI marked) drawn through and including steel conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling with necessary fittings, with one 1.5 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire complete all as specified and directed by the Engineer in Charge. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
M&L for flame proof submain wiring with approved colour coding as per IS with single core FRLS PVC insulated unsheathed multistranded copper conductor 1100 volts grade IS-694 marked as 02 runs of 10.0 Sqmm for phase & neutral and 01 run of single core 10.0 sq. mm as earth wire drawn through and inluding heavy duty ISI marked surface mounted ERW stove enamelled, steel conduit suitable for flame proof wiring, not less than 20mm dia with and including flame proof bends and elbows, couplers, bell mouth reducer, junction box all as per relevant IS all as specified and directed. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
Supply and fixing LED light fitting 2x20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed.
Supply and fix flame proof weather proof plug in switch socket 16Amp, 3 Pin (2P+E), 16A, single pole 250V complete all as specified and as directed.
Supply and fix flame proof weather proof DB SPN DB 8 way MCDB of Make Sudhir CAT Part No. MCDB - 186 complete all as specified and directed by EIC.
Supply and fix in repairs MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB single pole 6 to 32 amp complete all as specified and directed.
Supply and fix in repairs MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB SPN 40 to 63 amp complete all as specified and directed.
M & L for flame proof submain wiring with approved colour coding as per IS with single core PVC insulated but unsheathed FRLS cable, 02 run of single core 6.0 Sqmm for phase and neutral and 01 run of single core 6.0 sq. mm earth wire multistranded copper conductor 1100 volts grade IS-694 marked drawn through and including heavy duty ISI marked surface mounted ERW stove enamelled, steel conduit suitable for flame proof wiring, not less than 20mm dia with and including flame proof bends and elbows, couplers, bell mouth reducer, junction box all as per relevant IS all as specified and directed. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
M&L for surface mounted flame proof junction box 3 to 4 way 20mm min all as per relevant IS for flame proof submain wiring complete all as specified and directed by Engr-in-Charge.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN, 440 volts, 4 ways complete all as specified and directed by Engr-in-Charge.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN, 440 volts, 8 ways complete all as specified and directed by Engr-in-Charge.
S&F in repairs MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 100 amp complete all as specified and directed.
S&F in repair MCBs of 'C' series having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of TPN 40 amp complete all as specified and directed.
M&L for copper plate of size 300x300x3mm fixed on wall with porcelain insulators including brazing/connecting to copper strip of 20x3mm as required all as directed by Engr-in-Charge.
Material and labour for copper strip as earth continuity conductor or main earthing lead of size 20 x 3 mm complete all as specified and directed.
Supply & fix air curtain 4 ft legth of size 365 x 330 mm (Height x Depth) with power rating 440V, air velocity 20-22 meter per second, 'E' class insulation, Nozzle angle vertically downward, suitable for 3 phase, Motor capacity - 3/4 HP, RPM -1440 complete all as specified and directed by Engr-in-Charge.
Supply & fix air curtain 6 ft legth of size 365 x 330 mm (Height x Depth) with power rating 440V, air velocity 20-22 meter per second, 'E' class insulation, Nozzle angle vertically downward, suitable for 3 phase, Motor capacity - 1.0 HP, RPM -1440 complete all as specified and directed by Engr-in-Charge.
Material and Labour for industrial type double pole, earth (2P + E) socket and plug with a three pin, neutral and earth with 16 Amp, 275V with enclosure complete all as specified and directed.
Material and Labour for AC Surge Protection Device (SPD), 275V, 16 Amps suitable for industrial type socket double pole, earth (2P+E) complete all as specified and directed by the Engr-in-Charge.
Supply and fix building security light fittings, with pressure die cast aluminium housing sitable for 25W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated location all as specified and directed by Engr-in-Charge.
Material & labour for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including 4mm dia GI wire, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately.
M&L for submain wiring with two runs of single core PVC insulated multi stranded copper conductor cable FRLS of size 2.5 sqmm 1100 volt grade (ISI marked) drawn through and including steel conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on wall and surface on ceiling with necessary fittings, with one 2.5 Sqmm single core multi stranded copper conductor cable FRLS as earth continuity to common earth doly as earth wire complete including taking down old sub main wiring any type any size and making good the disturbed surfaces complete all as specified and directed. Note : Two runs of main wire and one run of earth wire & one run of steel conduit shall be measured and paid as one length.
M&L for point wiring for one light point/fan point controlled by one switch 5 amp one way using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multistranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No drawn through drawn through and including PVC casing caping not less than 20x12mm ISI marked ivory colour including accessories like bends, tees junction boxes, etc fixed on wall or ceiling etc including 1.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FRLS cable 1100 Volts grade as earth continuity wire including sunken type pressed steel terminal boxes of suitable size white sheet cover for mounting swiches, sockets, fan regulators etc complete all as specified and directed.
All as per item No 137 above but with 2.5 Sq mm cable for Independent one 6 pin 5/15 Amps socket outlet in and including 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS-694 FRLS cable for continuous earth wire.
S&F in repair switch piano 5 amps flush type single pole one way complete all as specified and directed.
S&F in repair switch piano 16 amps flush type single pole one way complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 5 pin 16 amps flush type complete all as specified and directed.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways complete all as specified and directed.
Supply and fixing in repair LED 4 feet tube light fitting 1x 18W, 220V, AC decorative type connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply & Fixing in replacement of LED flood light 200W made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection 230 Volt with all connected acessories required as directed by Engr-in-charge.
Harsh Enterprises (BID ID -3124111)
DEV INDUSTRIES (BID ID -3123689)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .