Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
30 Nov 2026, 3:00 pmDue tomorrow
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Sudipta Bose (EE/EL)
nbdd uttarkanya
Electrification and Allied works including Deep Tubewell of Insfracture development and setup of new smart classroom at Barakaimari Junior Basic school at Sitalkuchi block in the District of Coochbehar.
2026_NBDD_1048924_2
NBDD/BS/EE /NIQ-41 - (EL) of 2026-2027
Open Tender
Electrical Work/ Equipment
Item Rate
120 days
Cooch Behar
Please refer Tender documents.
6 documents required · 6 mandatory
₹40,000
Yes
30 Nov 2026
6 Nov 2026
2 Dec 2026
6 Nov 2026
30 Nov 2026
6 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution
board of sheet steel, dust protected, duly powder
painted, inclusive of 200 A tinned copper bus bar,
common neutral link, earth bar, din bar for mounting
MCBs (but without MCBs and incomer ) as required .
(Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
4 way (4 + 12), Double door.(Make: Legrand/Schneider/Siemens/Havells Crabtree/L&K as per the choice of EIC) | 1 | Set | - | - |
| 2 | Providing and fixing following rating and breaking
capacity and pole MCCB with thermomagnetic
release and terminal spreaders in existing cubicle
panel board including drilling holes in cubicle panel,
making connections, Ics=100% Icu and Operational
Voltage 690V etc. as required. 100A(Make :Legrand/Schneider/Siemens/Havells Crabtree/L&K) | 1 | Each | - | - |
| 3 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10
kA, "C" curve, miniature circuit breaker suitable for
inductive load of following poles in the existing MCB
DB complete with connections, testing and
commissioning etc. as required.
Triple pole(Make: Legrand/Schneider/Siemens/Havells Crabtree/L&K as per the choice of EIC) | 1 | Each | - | - |
| 4 | Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FRLS/HFFR PVC insulated
copper conductor single core cable ( Make :Havells/Polycab/Finolex/RR Cabel as per the choice of EIC) in surface/
recessed medium class PVC conduit, with modular
switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm FRLS/HFFR PVC insulated
copper conductor single core cable etc. as required.
Group C | 108 | Point | - | - |
| 5 | Supplying and fixing following modular switch/ socket( Make :Legrand Nextgen /Schneider/Siemens/Havells Crabtree/L&K as per the choice of EIC)
on the existing modular plate & switch box including
connections but excluding modular plate etc. as
required.
5/6 A switch | 10 | Each | - | - |
| 6 | 3 pin 5/6 A socket outlet | 10 | Each | - | - |
| 7 | Supplying and fixing suitable size GI box with modular
plate and cover( Make: Legrand Nextgen /Schneider/Siemens/Havells Crabtree as per the choice of EIC) in front on surface or in recess,
including providing and fixing 3 pin 5/6 A modular
socket outlet and 5/6 A modular switch, connections
etc. as required. | 24 | Each | - | - |
| 8 | Supplying and fixing suitable size GI box with modular
plate and cover( Make: Legrand Nextgen /Schneider/Siemens/Havells Crabtree as per the choice of EIC) in front on surface or in recess,
including providing and fixing 6 pin 5/6 & 15/16 A
modular socket outlet and 15/16 A modular switch,
connections etc. as required. | 14 | Each | - | - |
| 9 | Supplying & fixing suitable size GI box with modular
plate and cover in front on surface or in recess
including providing and fixing 25 A modular socket
outlet and 25 A modular SP MCB, "C" curve including
connections, painting etc. as required. | 2 | Each | - | - |
| 10 | Wiring for circuit/ submain wiring along with earth wire
with the following sizes of FRLS/HFFR PVC insulated
copper conductor, single core cable( Make: Havells/Polycab/Finolex/RR Cabel/Standard/Kei as per the choice of EIC) in surface/
recessed medium class PVC conduit as required
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 100 | mtr. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tendernotice_2.pdf
PDF • 0.52 MB
BOQ_2567836.xls
BOQ • 0.41 MB
DateC_0001.pdf
PDF • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .