Tender Value
₹21.0 L
EMD Value
₹21,000
Closing Date
1 Jun 2026, 6:00 pmClosed
Executive Engineer’s office, Valsad (R&B) Division,
Repairs To Residential Staff Quarters At Malanpada & Tin Darvaja Campus Ta- Dharampur Dist: Valsad (Toilet Bathroom and Drainage Work etc.)
308086
02 Of 2026-27 2nd time
Open
Civil - All
Valsad
8 documents required · 8 mandatory
₹900
Executive Engineer, Valsad (R&B)Division, Valsad
₹21,000
25 May 2026
25 May 2026
25 May 2026
1 Jun 2026
25 May 2026
Sr. Description of Item Quantity Unit Rate Amount
1 Dismentaling tiled of stone floors laid in mortar including stacking of 998.00 Sqmt 48.21
serviceable materilas and disposal of unserviceable materials with all
2 Dismantling santtary fittings like wash basin . W.C. pan Indian and 104.00 No 405.65
European type, flushing tank etc. including stacking the materials with
all lead and lift
3 Providing and laying antiskid ceramic tiles 30 x 30 cm size 6 mm thick 144.00 Sqmt 970.07
in flooring treads of steps and landing laid on a bed of 12 mm thick
cement mortar 1:3(1-cement:3-coarse sand)finishing with flush
pointing in white cement
4 Providing and laying glazed tiles tiles size 30 x 45 cm 6 mm thick in 854.00 Sqmt 1441.22
skirting risers of steps and dedo on 10 mm thick cement plaster 1:3 (1-
cement:3coarse sand) and jointed with colour cement slurry
5 Applying two coats of Acrylic lapy (putty) & two coats of primer of 443.00 Sqmt 40.59
approved brand and manufacture on new wall surface to give an even
shade including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth.
6 Wall painting (two coats) with plastic emulsion paint of approved 443.00 Sqmt 52.19
brand and manufacture on undecorated wall surface to give an even
shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
7 Painting (two coats) with plastic emulsion paint of approved brand 144.00 Sqmt 85.76
and manufacture on undecorated ceiling surface to give an even
shade including throughly brushing the surface free from mortar
droppings and other foreign matter and sand papered smooth.
8 Providing Water proofing Treatment on Sunk Slab including cement 292.00 Sqmt 340.88
concrete flooring 1:2:4 (1-cement : 2-coarse sand : 4-graded stone
aggregate 20mm nominal size) laid in one layer and finished with a
floating coat of neat cement average 50mm thick to Prepare slope
including water proofing chemical etc. Complete for Sunk Slab All
9 Providing laying and jointing in true line and level 50mm dia. 100.00 Rmt 195.67
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved
by Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
10 Providing laying and jointing in true line and level 40mm dia. 100.00 Rmt 148.12
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved
by Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
11 Providing laying and jointing in true line and level 25mm dia. 100.00 Rmt 91.84
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall with
the help of clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing of pipe and
joints and fixing the same with adhesive solvent, including cost of all
12 Providing laying and jointing in true line and level 15mm dia. 520.00 Rmt 72.65
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved
by Engineer In Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as directed
including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all
13 Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 working 90.00 Rmt 336.24
pressure poluthene pipes of the following outside Dia. Low densidy,
complete with special falnge compression type fittings, wall clipsetc.
including making good the wall ceiling and floor.(G)110 mm
14 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 52.00 No 571.08
mm diameter with jali of the following nominal diameter of self
cleansing design with C.I scread down or hinged grating including the
cost of cutting and making good the walls.
15 Providing and fixing water closet squatting Pan (Indian type W.C. 52.00 No 940.14
Pan) size 580mm (Earthwork, bed concrete, foot reste and trap to be
measured and paid for separately) (A) Vitreous China.(I) Long pattern
16 Providing and fixing brass screw down stop tap.(A) 15mm dia. 104.00 No 205.83
17 Providing and fixing washbasin with single hole for pillar tap with C.I. 52.00 No 1670.26
or M.S. brackets painted white including Rubber plug, sutting holes
and making good the same but excluding fittings and also including
rate of C.P. brass waste for washbasin or sink (A) 32mm dia. and
M.I. fisher union for washbasin or sink. (A) 32mm dia.; (A) Vitreous
China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white
18 Providing and fixing 600mm x 450mm bevelled edge mirrror of 52.00 No 833.73
superior glass mounted on 6mm thick A.C. sheet or plywood sheet
and fixing to wooden pluge with C.P. brass screws and washers.
19 Providing and fixing C.P. brass towel rail comlete with C.P. brass 52.00 No 603.19
brackets fixed to wooden plugs with C.P. brass scews (B) 600mm x
20 Providing and fixing screw down bib taps of following size.(A) Brass 104.00 No 186.83
screw down bib tap polished bright. (i) 15mm dia.
21 Providing and fixing pillar tap, capstan head, screw down high 52.00 No 308.73
pressure with screws, shanks and back nuts. (i) 15mm dia.
22 Providing and fixing chromium plated brass half trun flush cock of 52.00 No 263.77
approved quality including fixing in pipe line etc. complete (ii) 25mm
23 Providing and fixing S.W. gully trap with C.I. grating brick masonry 52.00 No 1246.92
chamber and water tight C.I. cover with frame of 300mm x 300mm
size (inside) with standard weight (i) Square mouth traps (B) 150mm x
100mm size P or R type
Deputy Executive Engineer, Executive Engineer
Dharampur (R&B) Sub Division Valsad (R&B) Division
Dharampur Valsad
I/We am/are willing to carry out the work at ………………………………………………..% above/below (percent should be written in
figures and words) of the estimated rates mentioned above. Amount of my/our tender works out as under.
*Estimated amount *Estimated amount
Put to tender Rs…2100982.05 Put to tender Rs…2100982.05
Deduct ……. % below Rs……………… Add ……. % Avove Rs…………..….
Net Rs. ……………… Total Rs. ………….…
In words ………………….…………………… In words ………………….
*( please strike out whichever is not applicable)
All works shall be carried out as public works department Handbook and other
specification of Division or as directed.
All the columns in schedule should be filled in ink or ballpen and the total of the
entries in last column should be struck by the contractor under his signature.
Rate quated include clearance of site (Prior commencement of work and at its close)
in all respects and hold good for work under all conditions,site moisture, weather etc.
The Contractor shall exhibit a board with detailed specification and details of work
as directed by the Engineer-In-Charge for which no extra payment shall be made.
The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
GST and Income tax TDS will be deducted at a source while making payments of bills
In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per
Govt. G.R.: PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in
S.O.R. therefore in R.C.C. items where there is a change as per actual mix design the cost
of difference of cement consumption have been deducted from the rate of original item at
the rate of input rate mentioned in all the tender.
To be continued on additional sheet,if found necessary.
Deputy Executive Engineer, Executive Engineer
Signature of the contractor Dharampur (R&B) Sub Division Valsad (R&B) Division