Loading…
Loading…
Tender Value
₹3.2 Cr
EMD Value
₹6.3 L
Closing Date
25 May 2026, 3:00 pmClosed
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SNT TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N' or 'V' whichever is less; where, V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar Nature of work: "Any RI or EI or CLS or ABS or IBS work involving indoor & outdoor work (cable laying & termination)".
6 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Checklist for Tenderer: The Tenderer shall submit signed copy of Check-list placed in documents attached with tender. The Tenderer shall also submit relevant documents of compliance of the checklist if any.
While bidding, bidder should submit the MOU of RDSO approved source (OEM or his RDSO approved source) of existing MEDHA make EI at the time of bidding covering supply of the equipment of EI, installation, alteration, testing and commissioning of EI including after sales support required during the warranty period and beyond the warranty period, failing which tender/offer shall be summarily rejected.
Bhavnagar Division: Supply installation, Testing, Commissioning of Signalling gears and alteration in Medha make Electronics Interlocking system at Kothgangad, Alau, Hadalabhal in connection of Sabarmati - Botad Section - Providing of track machine sidings.
DRMSnT-BVP-Sig6R1of26-27
DRMSnT-BVP-Sig6R1of26-27
Open
Works - General
12 Months
Bhavnagar, Gujarat
₹0
₹6.3 L
25 May 2026
1 May 2026
11 May 2026
208 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 40,84,136.94 | ||
| — | 4.00 | — | — | ||
| INPUT WFM CPU Card of MEDHA make Electronics Interlocking system. | — | — | — | 1,73,892 | |
| — | 150.00 | — | — | ||
| Rubber Mat for Power Equipment room. (5mm thick). | — | — | — | 18,244.5 | |
| — | 6.00 | — | — | ||
| Supply of Surge protection device (SPD) 4- Pole, 5V versions similar to model no MDP- 4 D-5-T of OBO make. Make OBO, Phoenix, ABB or DEHN. | — | — | — | 29,098.8 | |
| — | 0.30 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq. mm. (85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | — | — | — | 10,009.86 | |
| — | 0.30 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm). 101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | — | — | — | 40,819.06 | |
| — | 0.30 | — | — | ||
| Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | — | — | — | 39,751.54 | |
| — | 2.00 | — | — | ||
| Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2 mm), as per IRS 76/89 (Amd3) or latest. | — | — | — | 11,097.08 | |
| — | 200.00 | — | — | ||
| Supply of 35 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 49,548 | |
| — | 200.00 | — | — | ||
| Supply of 10 Sq. mm PVC insulated Single core Multistrands copper conductor (Red/Black/Green) as per IS:694/2010 or latest, as per Specification No. IRS:S-76/89 or latest. Colour of the wire which is required will be specified by the Engineer in charge. | — | — | — | 21,134 | |
| — | 6.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signalling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signalling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card. (unit read as per module) | — | — | — | 1,78,461.78 | |
| — | 3.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signalling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signalling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. (unit read as per module.) | — | — | — | 1,55,861.34 | |
| — | 150.00 | — | — | ||
| Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 2,790 | |
| — | 60.00 | — | — | ||
| Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 3,059.4 | |
| — | 60.00 | — | — | ||
| Indicative type Fuse Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS: S-80/92. | — | — | — | 2,066.4 | |
| — | 60.00 | — | — | ||
| Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | — | — | — | 3,432.6 | |
| — | 3.00 | — | — | ||
| Earth Leakage Detector as per RDSO/SPN/256/2002 or latest with latest amendments. The basic detector unit shall comprise of 8 channels, for use on signalling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance. Installation as per instruction of Engg in charge. | — | — | — | 4,54,724.67 | |
| — | 6.00 | — | — | ||
| Miniature, Plug in Type, M to C, DC Neutral, Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec: BRS :939-A & 966 (Appx-F2) & IRS: S-23, S-23, S-34 & 60. | — | — | — | 29,273.4 | |
| — | 6.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral, Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec: BRS:933A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 32,528.4 | |
| — | 6.00 | — | — | ||
| Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery. | — | — | — | 21,139.62 | |
| — | 6.00 | — | — | ||
| Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base). | — | — | — | 5,870.76 | |
| — | 30.00 | — | — | ||
| Track Lead Junction Boxes as per C. Rly Drg. No. RST 11509 made from fibre glass/SMC/FRP along with terminal blocks. | — | — | — | 33,619.5 | |
| — | 3000.00 | — | — | ||
| GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. | — | — | — | 2,04,510 | |
| — | 90.00 | — | — | ||
| Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. | — | — | — | 543.6 | |
| — | 30.00 | — | — | ||
| Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split- Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement). | — | — | — | 40,377.9 | |
| — | 6.00 | — | — | ||
| Gauge Tie plate nylon insulation as per RDSO Drg No: T-10372Alt2, T-10368, T-10371 Alt2, T- 15083/88/Alt2 & T-11690/Alt2 and to the spec. IRS: S-40/84 with latest amendments as applicable. | — | — | — | 9,022.08 | |
| — | 3.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer in charge as per requirement. As per RDSO/SPN/219/2016 ver 1.0 with latest Amd. | — | — | — | 29,231.91 | |
| — | 3.00 | — | — | ||
| Colour Light Signal Complete. This includes: - (1). Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA- 24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3). Pinnacle. (4). Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. (5). Signal Front Staging Complete Assembly for CLS Unit. (6). Signal back staging as per extent WR Practice. Note: Height of the Post shall be 5.5 Long. | — | — | — | 41,981.37 | |
| — | 3.00 | — | — | ||
| Non Metallic (FRP) color light signal housing multi-unit type for railway signalling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | — | — | — | 85,733.16 | |
| — | 9.00 | — | — | ||
| Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377 Note: This item includes the supply & fixing of 2 Nos E Type Lock fitted on both doors, along with two Keys. | — | — | — | 1,40,499.63 | |
| — | 750.00 | — | — | ||
| — | — | — | 56,250 | ||
| — | 3600.00 | — | — | ||
| — | — | — | 15,67,872 | ||
| — | 21.00 | — | — | ||
| — | — | — | 40,156.2 | ||
| — | 72.00 | — | — | ||
| — | — | — | 84,260.16 | ||
| — | 3.00 | — | — | ||
| — | — | — | 13,590.21 | ||
| — | 18.00 | — | — | ||
| Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197 with latest Amd. | — | — | — | 1,87,255.44 | |
| — | 60.00 | — | — | ||
| Earth Electrode as per Drg. No. CSTE / 6091. | — | — | — | 1,67,939.4 | |
| — | 60.00 | — | — | ||
| Supply of copper strip for earthing (25mm x 3mm) | — | — | — | 34,389.6 | |
| — | 90.00 | — | — | ||
| Supply of GI flat for earth (50 X 6 mm). | — | — | — | 18,600.3 | |
| — | — | — | 2,75,20,081.84 | ||
| — | 3.00 | — | — | ||
| Modification of EI System of Medha at 7 Stations of WR (Kothgangad, Alau, Hadalabhal,) as per RDSO spec no: RDSO/SPN/192/2019, in connection with the provision of TrackMachine SidingSupply of EI additional Hardware as per the tentative SIP provided with 15% I/O bis as spares.Modification to the existing Application Logic circuits and Interface circuits. Alteration to the MT and VDU software. Up-gradation of Data- logger database at MEDHA end. FAT (Factory Acceptance Test), SAT and commissioning as per the Modified Application Logic. ASMADES. (One unit read as per LS). | — | — | — | 1,28,25,000 | |
| — | 6.00 | — | — | ||
| Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station. The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC-PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Approximate Screen size 55 inch. Prior approval to be taken from Engg in charge. | — | — | — | 5,19,822 | |
| — | 3.00 | — | — | ||
| Design of Cable Route Plan submission of Three paper copies for approval. | — | — | — | 29,619 | |
| — | 3.00 | — | — | ||
| Supply of final Cable Route Plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables in original tracing along with Auto CAD in Pen Drive and Six set copies after approval. (One unit read as per station) | — | — | — | 4,740 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderCondisitionandSchedule.pdf
ATTACHMENT
GCC-2022-uptoACS10_merged_compressed.pdf
ATTACHMENT
SignedJPOBVPDivisionforundertakingdiggingworkinthevicinityofSTandElectricalcablesmerged..pdf
ATTACHMENT
CHECKLISTFORTENDERERmorethan50Lacs.pdf
ATTACHMENT
GCCACS11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .