Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAdmitted-Finance JL 103 SUTAHATA SRI KRISHNAPUR HALDIA EAST MEDINIPUR WEST BENGAL 721635 UDYAM WB 10 0002192 19AAACW6033G1ZC B R MSME STATUS AS NOT VERIFIED | MEDINIPUR EAST | WEST BENGAL | 721635 | ₹5.1 L | L1 | Admitted-Finance |
| 2 | L2₹5.3 LAdmitted-Finance | ₹5.3 L | L2 | Admitted-Finance |
| 3 | L3₹5.5 LAdmitted-Finance 46C 7G EVEREST HOUSE CHOWRINGHEE ROAD MIDDLETON ROW KOLKATA 700071 | KOLKATA | KOLKATA | WEST BENGAL | 700071 | ₹5.5 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Superintendence Co of India Pvt Ltd L3 | SCIENTIFIC RESEARCH LABORATORY L2 | WEST BENGAL WASTE MANAGEMENT LIMITED L1 |
|---|---|---|---|---|---|---|
| 1.00Environment Monitoring | ||||||
| 1.01 | Collection of samples for emission through stack/stacks of the
operating unit/units of the Power Station conducting analysis
(SPM, SO2, NOx, Mercury etc. and submitting report etc. all as
per guideline /stipulation of MOEF, GOI/WBPCB for 24 (twenty
four) months. | 64 | Months | 1,100 ₹70,400 | 700 ₹44,800 | 1,200 ₹76,800 |
| 1.02 | Collection of sample for ambient air from 04 (four) different
identified locations prevailing at the Power Station conducting
analyzing and submitting report containing relevant parameters
including PM2.5, PM10, SO2, NO2, CO,O3, NH3, Pb,
C6H6, As, Bap, Ni (1 hour & 8 hour report for CO and O3
to be submitted separately) etc. all as per guideline/stipulation
of MOEF, GOI/WBPCB for 24 (twenty four)months. | 96 | Months | 1,000 ₹96,000 | 2,880 ₹2.8 L | 1,450 ₹1.4 L |
| 1.03 | Collection of sample for analyzing liquid effluent water from
Boiler Blow Down at outfall location and submitting report
containing relevant parameters including pH, TSS, Oil & Grease,
BQD, COD, Free available Chlorine, Cu, Fe (all in mg/lit) etc.
all as per guideline/stipulation of CEA, MOEF, GOI/WBPCB for
24 (twenty four) months. | 24 | Nos | 1,200 ₹28,800 | 500 ₹12,000 | 1,100 ₹26,400 |
| 1.04 | Collection of samples for analyzing liquid effluent water from
Power House Common Disposal Sump at outfall location and
submitting report containing relevant parameters including Oil &
Grease, pH, TSS, BOD & COD, Cu, Fe, Zn, Cr, & P (All in
mg/lit. except pH) etc. all as per guideline/stipulation of CEA,
MOEF, GOI/WBPCB for 24 (twenty four) months. | 24 | Nos | 1,200 ₹28,800 | 500 ₹12,000 | 1,100 ₹26,400 |
| 1.05 | Collection of samples for analyzing liquid effluent water from
Condenser Blowdown at outfall location and submitting report
containing relevant parameters including pH, TSS, BOD, COD.
Fe, Oil & Grease, Free Available Chlorine, Inlet & Outlet
Temperature etc. all as per guideline/stipulation of CEA, MOEF,
GOI/WBPCB. for 24 (twenty four) months. | 24 | Nos | 1,200 ₹28,800 | 450 ₹10,800 | 1,100 ₹26,400 |
| 1.06 | Collection of samples for analyzing liquid effluent water from
Township Discharge Canal for analyzing and submitting report
containing relevant parameters including pH, TSS, BOD, COD,
Oil & Grease, Fe (All in mg/lit except pH) etc. all as per
guideline/stipulation of CEA, MOEF, GOI/WBPCB for 24 (twenty four)months | 24 | Nos | 1,200 ₹28,800 | 450 ₹10,800 | 1,100 ₹26,400 |
| 1.07 | Collection of samples for analyzing liquid effluent water from Ash Pond effluent for analyzing & submitting report etc. as per
guideline/stipulation of CEA, MOEF, GOI/WBPC#. Parameters to
be tested are: pH, TSS, BOD, COD, Oil & Grease, Fe (All in
mg/lit. except pH), for 24(twenty four) months. | 24 | Nos | 1,200 ₹28,800 | 450 ₹10,800 | 1,000 ₹24,000 |
| 1.08 | Collection of samples for analyzing liquid effluent water from
Neutralizing Pit for analyzing & submitting report etc. all as per
guideline/stipulation of CEA, MOEF, GOI/WBPCB. Parameters to
be tested are: pH, TSS, COD & BOD, Oil & Grease, Fe (All in
mg/lit. except pH), for 24 (twenty four) months. | 24 | Nos | 1,200 ₹28,800 | 450 ₹10,800 | 1,000 ₹24,000 |
| 1.09 | Collection of samples not exceeding 2 (two) location for analyzing drinking water from Power House and Township for analyzing and submitting report etc. Parameters to be tested are: Odor, Taste, pH, TDS, Hardness (as CaCO3), Alkalinity (as CaCO3), Nitrate, Sulphate, Fluoride, Chloride, Turbidity (NTU), Arsenic, Copper, Cadmium, Chromium, Lead, Iron, Zine, Fecal Coliform (cfu) & E. Coli (cfu) (All in mg/lit. except pH), for 24 (twenty four)months. | 48 | Nos | 1,200 ₹57,600 | 1,150 ₹55,200 | 1,050 ₹50,400 |
Tender Value
₹5.8 L
Closing Date
25 May 2026, 3:00 pmClosed
GM(BTPS)
Administrative Building, Bandel Thermal Power Station, Hoogly 712503
Biennial Service Contract for Environmental Monitoring Works along with Submission of Reports at BTPS.
2026_WBPDC_1023760_1
WBPDCL/BTPS/NIT/E2815/26-27
Limited
Support/Maintenance Service
730 days
Bandel Thermal Power Station, Hoogly
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
Exempted
1 Jun 2026
11 May 2026
28 May 2026
11 May 2026
25 May 2026
11 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Environment Monitoring | ||||||
| 1.01 | Collection of samples for emission through stack/stacks of the
operating unit/units of the Power Station conducting analysis
(SPM, SO2, NOx, Mercury etc. and submitting report etc. all as
per guideline /stipulation of MOEF, GOI/WBPCB for 24 (twenty
four) months. | - | Months | - | - | 2 |
| 1.02 | Collection of sample for ambient air from 04 (four) different
identified locations prevailing at the Power Station conducting
analyzing and submitting report containing relevant parameters
including PM2.5, PM10, SO2, NO2, CO,O3, NH3, Pb,
C6H6, As, Bap, Ni (1 hour & 8 hour report for CO and O3
to be submitted separately) etc. all as per guideline/stipulation
of MOEF, GOI/WBPCB for 24 (twenty four)months. | - | Months | - | - | 3 |
| 1.03 | Collection of sample for analyzing liquid effluent water from
Boiler Blow Down at outfall location and submitting report
containing relevant parameters including pH, TSS, Oil & Grease,
BQD, COD, Free available Chlorine, Cu, Fe (all in mg/lit) etc.
all as per guideline/stipulation of CEA, MOEF, GOI/WBPCB for
24 (twenty four) months. | - | Nos | - | - | 9 |
| 1.04 | Collection of samples for analyzing liquid effluent water from
Power House Common Disposal Sump at outfall location and
submitting report containing relevant parameters including Oil &
Grease, pH, TSS, BOD & COD, Cu, Fe, Zn, Cr, & P (All in
mg/lit. except pH) etc. all as per guideline/stipulation of CEA,
MOEF, GOI/WBPCB for 24 (twenty four) months. | - | Nos | - | - | 10 |
| 1.05 | Collection of samples for analyzing liquid effluent water from
Condenser Blowdown at outfall location and submitting report
containing relevant parameters including pH, TSS, BOD, COD.
Fe, Oil & Grease, Free Available Chlorine, Inlet & Outlet
Temperature etc. all as per guideline/stipulation of CEA, MOEF,
GOI/WBPCB. for 24 (twenty four) months. | - | Nos | - | - | 11 |
| 1.06 | Collection of samples for analyzing liquid effluent water from
Township Discharge Canal for analyzing and submitting report
containing relevant parameters including pH, TSS, BOD, COD,
Oil & Grease, Fe (All in mg/lit except pH) etc. all as per
guideline/stipulation of CEA, MOEF, GOI/WBPCB for 24 (twenty four)months | - | Nos | - | - | 12 |
| 1.07 | Collection of samples for analyzing liquid effluent water from Ash Pond effluent for analyzing & submitting report etc. as per
guideline/stipulation of CEA, MOEF, GOI/WBPC#. Parameters to
be tested are: pH, TSS, BOD, COD, Oil & Grease, Fe (All in
mg/lit. except pH), for 24(twenty four) months. | - | Nos | - | - | 13 |
| 1.08 | Collection of samples for analyzing liquid effluent water from
Neutralizing Pit for analyzing & submitting report etc. all as per
guideline/stipulation of CEA, MOEF, GOI/WBPCB. Parameters to
be tested are: pH, TSS, COD & BOD, Oil & Grease, Fe (All in
mg/lit. except pH), for 24 (twenty four) months. | - | Nos | - | - | 14 |
| 1.09 | Collection of samples not exceeding 2 (two) location for analyzing drinking water from Power House and Township for analyzing and submitting report etc. Parameters to be tested are: Odor, Taste, pH, TDS, Hardness (as CaCO3), Alkalinity (as CaCO3), Nitrate, Sulphate, Fluoride, Chloride, Turbidity (NTU), Arsenic, Copper, Cadmium, Chromium, Lead, Iron, Zine, Fecal Coliform (cfu) & E. Coli (cfu) (All in mg/lit. except pH), for 24 (twenty four)months. | - | Nos | - | - | 15 |