Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹65.7 LAccepted-AOC | 1 | Accepted-AOC 1 |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
5 May 2021, 5:00 pmClosed
Executive Engineer
Executive Engineer, C.D. UPJN, Khatima
Retrofitting Work of Sarpura Water Supply Scheme for FHTC and Pipe line work etc complete of Block Khatima in District Udham Singh Nagar
2021_MDPEY_32441_1
748 / Nivida / 40 Dated 20-04-2021
Open Tender
Pipe Laying Works
Item Rate
60 days
Khatima
Please refer tender documents
3 documents required · 3 mandatory
₹4,720
Executive Engineer, C.D. UPJN, Khatima
₹1.3 L
Khatima
30 Jul 2025
22 Apr 2021
7 May 2021
23 Apr 2021
5 May 2021
23 Apr 2021
28 Apr 2021
Amount
Providing of all materials, carting from site store to site of work, laying & jointing of G.I. Medium screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc.) in trenches with its cutting, threading and testing of pipe line etc complete.
15 mm (Average 25.0 m for each house connection)
Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.
Supply of Multijet water meter ISI marked with fittings complete in all respect.
40 mm dia. (ISI marked)
Fixing of water meter in G.I. pipe line including cutting and threading of pipe etc. complete, but excluding cost of all materials. (Labour cost only)
32 to 40mm size G.I. pipe water main.
Making ferrule connection in the existing main of G.I, A.C, PVC or any type of pressure mains with saddle piece, service connections, fittings and fixing of ferrule including tapping the main, but excluding the cost of earth work and cost of all materials. (Labour cost only)
Constructing masonry Chamber for Wheel valve/ Water Meter with a floating coat of neat cement complete as per standard design : With F.P.S. bricks
Geo-tagging of each domestic connection on portal.
Providing and fixing brass ferrule 15mm dia. nominal bore for domestic connections.
Providing and fixing of PTMT bib cock 15 mm dia. nominal bore for domestic connections.
50 mm dia.
125 mm dia.
80 mm dia.
Constructing masonry Chamber for sluice valve with a floating coat of neat cement complete as per standard design : With F.P.S. bricks
Dismantling of normal cement concrete surface of edges of roads 1:3:6 or richer mix or hot mixed bituminous road surface manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level in 1:2:4 (1 Cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level,1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size)
Provide 1.5m high boundary wall in 23 cm thick brick masonry in 1:6, with RCC beam at plinth and columns @ 3.00m c/c including finishing with 1:4 cement plaster and painting as per drawing and direction of Engineer in charge.
Providing MS Gate of size 3.20m x 1.80m wt. not less than 270 kg, and construction of RCC column 0.45X 0.45X 1.80 and MS Gate fixed between RCC column's of the boundary wall as per direction of Engineer in charge including priming & painting etc complete for proper completion of work.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .