Loading…
Loading…
Tender Value
₹25 L
EMD Value
₹20,000
Closing Date
2 Sept 2026, 7:00 pm
Ex.Eng (O&M) Valsad Rural Division
Tender For Supply and installation of 11/22 KV distribution Transformer HT/LT Terminal Protector and Supply of HT/LT Booting, Transformer Earthing, Sleeves (Conductor Cover), Bird Guard in Any Scheme for Transformers (Including Installation) of Rankuwa Sub-Division Under Valsad Rural Division.
337543
DGVCL/VALSAD-R DO/E-TENDER/2026-27/83
Open
Miscellaneous Works
Works
Valsad
8 documents required · 8 mandatory
₹1,180
DGVCL, Payable Valsad
₹20,000
21 Aug 2026
21 Aug 2026
21 Aug 2026
2 Sept 2026
21 Aug 2026
-::- SCHEDULE-B -::-
The Rates inclusive of PF and Exclusive of GST
Item Code Item Unit FY 2024-25
Binding of messanger Conductorat with a
distance not more than 0.75 mtr with 6 turns
minimum on XLPE Cable with single strand
binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV
Distribution Transformers HT Terminal
2 9926000086 protector (UV Resistance) with using PER SET
95/120/150 sq.mm long barrel aluminum lug.
(1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22
kV Distribution Transformer with replacement
of bare conductor by HT ABC conductor (DO
3 9926000087 bottom side to transformer) after removal of PER SET
semi conductor by HT ABC (6 inch both side).
HT ABC to be supplied by DGVCL. (1Set =
Nos i.e. on R, Y, B)
Supply, Installation, Testing and
Commissioning of Maintenance Free, Ready
Capsule, Pipe-In-Cage (Pic) Type, Earth
4 9926000088 Electrodes for HT Feeder Pole Having 2000 NO
mm Electrode Length as per the Tender
Specifications and Drawing. (All Materials Will
Be Supplied By Agency)
Supply, Installation, Testing and
Commissioning of Maintenance Free, Ready
Capsule, Pipe-In-Cage (Pic) Type, Earth
5 9926000089 Electrodes for HT Feeder Pole Having 3000 NO
mm Electrode Length as per the Tender
Specifications And Drawing. (All Materials Will
Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip
having hot dip- galvanized-zinc coating of 80-
100 microns without any joints or welding.
Both the end of the GI strip should be
connected with GI nut bolts and required
fabrication work for giving separate earthing
(1) Neutral of the transformer
(2) MS structures of the transformer center
(Approximately 25 meter GI strip per
transformer centre
- as per requirement and instruction of
Engineer in- charge) (All Materials will be
supplied by Agency)
Supply and Installation of uPVC standard
make Pipe of 1.25" diameter for covering GI
strip with UV protected Cable Ties of 550 X
7.6 mm size to bind with pole
face(Approximately 25 meter uPVC pipe for
GI strip covering per transformer centre -as
per requirement and instruction of Engineer
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and Drop
8 9926000093 out fuse to Transformer H.T. including Busbar Per TC
(12 mm sleeve) as per technical specification.
(All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and Drop
9 9926000100 out fuse to Transformer H.T. without Busbar Per TC
(12 mm sleeve) as per technical specification.
(All Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and Drop
out fuse to Transformer H.T. including
Busbar(15 mm sleeve) as per technical
specification. (All Materials will be supplied by
Supply & fixing of upto 33 kV Conductor
sleeve for Busbar to Drop out Fuse and Drop
out fuse to Transformer H.T. without
Busbar(15 mm sleeve) as per technical
specification. (All Materials will be supplied by
Supply & fixing of Disc type Red Color
FRP(Non-flammable) material with Weather
resistant, Non-conductive bird guard OD=300
MM, ID=33 MM, Width =1.25 MM, one side
cut from ID to OD. (All Materials will be
supplied by Agency)
Providing and fixing of LT Terminal protectors
i.e. Re-useable boot (LT Side 1.1 kV)
13 9926000096 including LT (1.1 kV) insulating taps. All live No
part at LT side shall be covered with fixing of
LT insulating taps.
14 Nylon Net around Transformer Center
14.1 9926000097 Nylon Net (12 * 15 ft) Per Net
14.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All
14.3 9926000099 fabricated material for fitting nylon net shall Per TC
be provided by DGVCL)
1. DGVCL will provide key material like M.S.
materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to
the contractor.2.All fabricated items shall be
fabricated as per DGVCL approved drawing
and by welding rods confirming to the
relevent ISI specification and as directed by
Engineer in charge.3.Necessary electricity
connection for fabrictated items shall be
provided by DGVCL on payment of required
charge for connection & electricity bill of the
same shall be paid by the agency.4.All the
rates are inclusive of PF and Exclusive of GST
applicable time to time.5.All steel material are
to be painted as below:(a) Scrubbing of
rusted surface properly before applying the
paints on to the RSJ poles & steel fabricated
materials of RSJ/PSC poles is must
required.(b) Two coats of approved ISI mark
red oxide (primer) is to be properly painted
for the RSJ poles & steel fabricated materials
of RSJ/PSC poles. (c) Two coats of approved
ISI mark silver paint (i.e. triple mangoes or
equivalent quality silver paint) is to be
properly painted on to the RSJ poles & steel
fabricated materials of RSJ/PSC
Total of schedule B….
(+)_______%Above, (-)_______%Below, Rate to
Net Total of Schedule B:
Amount in Words: (Twenty-Five lacs only)
1. Whatever Steel Material removed after replacement should be credited to Store.
2. The rates are inclusive of PF & Work Contract Tax & excluding of GST.
3. Contractor has to carry out work under Rankuwa Sub-Division under Valsad-Rural
4. DGVCL will provide 1ph & 3ph LT Ariel Bunch Cable 11/22kv HT ABC with necessary
accessories to the contractor.
5. The rates are inclusive of dismantling charges of existing bare conductor and
crediting in to store & dismantling of service lines from LT bare conductor and to
provide service connections on ABC by insulated pierce connectors through service
connection box.
6. The contractor has to collect all the required materials from DGVCL store as well as
credit the dismantle material to the DGVCL store at their cost.
1. DGVCL will provide key material like M.S. materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding
rods confirming to the relevent ISI specification and as directed by Engineer in charge.
3. Necessary electricity connection for fabrictated items shall be provided by DGVCL on
payment of required charge for connection & electricity bill of the same shall be paid by the
4. All the rates are inclusive of PF and Exclusive of GST applicable time to time.
5. All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on to the RSJ poles &
steel fabricated materials of RSJ/PSC poles is must required.
(b) Two coats of approved ISI mark red oxide (primer) is to be properly painted for the
RSJ poles & steel fabricated materials of RSJ/PSC poles.
Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint)
is to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
Executive Engineer (O&M)
Valsad Rural Division.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
GENERAL TERMS and CONDITIONS.pdf
Notice Inviting Tender.pdf
Schedule-B.pdf
TECHNICAL SPECIFICATIONS FOR THE WORK.pdf
Amend an Arbitration Clause.pdf
TECHNICAL BID.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].