Loading…
Loading…
Tender Value
₹17.4 L
EMD Value
₹18,000
Closing Date
19 Oct 2026, 6:00 pm
Deputy Municipal Commissioner (D)
STRUCTURAL REHABILITATION & RENOVATION WORK OF BHARTHANA -3 ANGANWADI AT BHARTHANA VILLAGE AND LAL TAMBU ANGANWADI AT KOSAD VILLAGE IN NEW EAST (SARTHANA) ZONE, SURAT.
351646
DMC/NEZ/10/2026-2027,Work No. 02
Open
Repair and Maintenance
Works
Surat
3 documents required · 3 mandatory
₹1,062
Commissioner, Surat Municipal Corporation
₹18,000
3 Oct 2026
3 Oct 2026
3 Oct 2026
19 Oct 2026
3 Oct 2026
NAME OF WORK:- STRUCTURAL REHABILITATION & RENOVATION WORK OF BHARTHANA -3 ANGANWADI AT
BHARTHANA VILLAGE AND LAL TAMBU ANGANWADI AT KOSAD VILLAGE IN NEW EAST (SARTHANA) ZONE,
SOR 2024-25 & MR
Description Qty. Unit Amount
(A) ANGANWADI AT BHARTHANA-3
PART A:- REPAIR + REHABILITATION
Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness consider)
Heavy Roller plaster on walls or similar surfaces at all floor levels consisting of
12 mm av. Th. Backing coat of C.M. 1:3 (1 cement:3 sand : racron 3s ( 0.5 nos
per bag )) also plaster master wterproofing chemical
1 ml /bags as per companey manual & approved by E.I.C or consultant & 8 mm.
th. Finishing coat of C.M. 1:1 (1 cement:1 sand) apply thick cement slurry and
apply roller horizontal as well as vartical ( two times ) up to good quality and size
of grain in elevation as per directed by engineer incharge
up to plinth level 13.00 417.00 S.M.
WORK ABOVE PLINTH LEVEL
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 Design mix concrete as per IS 456:2000 (latest revision) and as
2 per tender specification in all items including cost of form work and
rendering but excluding cost of reinforcement. (With using plastisizer
(A) foundation, footing, base of columns and mass concrete
For Sintex Tank (Upper Terrace) 1.00 4373.05 C.M.
Providing, mixing, placing, compacting by machine vibrator, curing,
testing M25 Design mix concrete as per IS 456:2000 (latest revision) and as
3 per tender specification in all items including cost of form work and
rendering but excluding cost of reinforcement. (With using plastisizer
(1)Having c/s area up to 0.08 s.mt
Ground Floor 0.00 12930.68 C.M.
First Floor (Terrace Floor) 0.00 12971.23 C.M.
(2) c/s area more than 0.08sq. mt. & upto 0.12 sq.mt
Ground Floor 0.00 11253.32 C.M.
First Floor (Terrace Floor) 0.00 11293.87 C.M.
(3) Having cross sectional area more than 0.12 sq. mt.
Ground Floor 0.00 9288.03 C.M.
First Floor (Terrace Floor) 0.00 9328.58 C.M.
(1)Having c/s area up to 0.08 s.mt
Ground Floor 0.00 9083.57 C.M.
First Floor (Terrace Floor) 0.00 9124.12 C.M.
(2) c/s area more than 0.08sq. mt. & upto 0.12 sq.mt
Ground Floor 0.00 8155.37 C.M.
First Floor (Terrace Floor) 0.00 8195.92 C.M.
(3) Having cross sectional area more than 0.12 sq. mt.
Ground Floor 0.00 7067.84 C.M.
First Floor (Terrace Floor) 0.00 7108.39 C.M.
2) Slabs having more than 8cm. and upto 10 cm. Th'.
Ground Floor 0.00 7965.38 C.M.
First Floor (Terrace Floor) 0.00 8005.93 C.M.
(3) Slabs having more than 10 cm. & upto 13 cm. Th'.
Ground Floor 0.00 7377.92 C.M.
First Floor (Terrace Floor) 0.00 7418.47 C.M.
SOR 2024-25 & MR
Description Qty. Unit Amount
4) Slabs having more than 13 cm. Thickness
Ground Floor 0.00 6793.97 C.M.
First Floor (Terrace Floor) 0.00 6834.52 C.M.
Ground floor 0.09 7119.46 C.M.
First Floor (Terrace Floor) 0.00 7160.01 C.M.
Ground floor 0.00 9963.33 C.M.
First Floor (Terrace Floor) 1.23 10003.88 C.M.
Providing & fixing IS Mark TMT Bar FE 500d reinforcement for R.C.C. work
incl. bending, binding & placing in position etc.comp.---Ground Floor
Ground floor 6.00 77.29 Kg.
First floor (Terrace Floor) 80.00 78.34 Kg.
Providing throatingor plasterdrip and moulding it toR.C.C. chajja etc.
comp.. For all Floor (M.R.)
Providing 20mm deep finished groove in plaster in lineand level etc. Comp. For
all Floor (M.R.)
DISMANTLING WORKS
Demolition of brick work and stone masonry including stacking of serviceable
7 materials and disposal of unserviceable materials with all lead and lift. (i) On 0.30 577.92 C.M.
Removing the scraping of old deteriosted plaster of any thickness form
8 wall/R.C.C. member including strcking of serviceable material and disposal of 37.86 20.55 S.M.
unserviceable material from site of work with all lead and lift.
Demolition including stacking of serviceable materials and disposal of
9 unserviceable materials with all lead and lift.' 0.04 1110.75 C.M.
Demolition of terrace including stacking of serviceable materials and disposal of
10 unserviceable materials with all lead and lift.' 1.) Brick 45.06 66.81 S.M.
Dismantling C.I. Pipes, G.S.W. Pipes and A.C.,PVC rain water pipes with
11 fittings and clamps including stacking the materials with all lead & lift ( For any 30.00 78.51 R.M.
Dia. of pipes )
Dismantling Doors, Windows, Ventilators etc. (wood or steel) shutters including
chowkhats, architreaves, holdfasts, and other attachment etc. complete and
stacking them within all lead and lift.
(1) Not exceeding 3 sq. meters in area .
Dismentaling of Tiles floors laid in mortar including stacking of serviceable
13 material and disposal of unserviceable material with all lead and lift 15.73 50.11 S.M.
REPAIR & REHABILITATION WORKS
Fixing clerestory window chowkhats in existing openings including cutting
masonry for hold fasts, embedding hold fasts in cement concrete blocks with
cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate
14 mm single size), painting two coats of coal tar to sides of chowkhats and making 1.00 399.00 NOS.
good the damge to walls complete including disposal of rubbish to the dumping
SOR 2024-25 & MR
Description Qty. Unit Amount
Providing and applying cement mortar (1:3) modified by using polymer and
expanding grout additives at various thickness for repair/strengthening of various
RCC elements at all floor levels, lead, lift, including breaking, chipping,
dismentling existing cover concrete and exposing existing reinforcement,
15 applying wirebrush for making surfaces of steel and concrete free from rust and
other loose materials, applying rust removing chemical on existing reinforcement,
applying anti-corrosive coating on existing reinforcement, applying polymer
bonding agent on existing concrete surfaces before applying polymer modified
mortar in specified thickness as directed by the Engineer-in-charge.
The rates shall also include providing and applying 12 mm thick cement mortar
(1:4) modified with plasticizer for finishing smooth the repaired surfaces,
providing and applying curing agent on the repaired surfaces, etc. complete as
directed by the Engineer-in-charge. The make and quality of rust removing
chemical, anti-corrossive coating, polymer bonding agent, polymer and
expanding grout additives, plasticizer, curing agent, etc. shall be approved by
engineer-in-charge. The procedure for application shall be strictly in accordance
with manufacturer's detail specification, which shall be submitted before start of
work and shall be approved by the Engineer-in-charge.
The rates shall include the cost of providing, erecting and maintaining leakproof
shuttering /formwork /scaffolding, etc. to be used for the purpose, providing and
erecting props, temporary frame work and maintain them in position for required
time, to existing load bearing elemnts for reliving loads coming on to structural
members being repaired/strengthened but excludes the cost of reinforcement.
The rates shall include the cost of providing, erecting formwork with drainage
outlet for presocking and air venting. The formwork shall be such that it provides
suitable excess points to pour or pump the mixed micro fluid concrete in place.
The cost shall also include providing and erecting props, temporary frame work
and maintain them in position for required time, to existing load bearing elements
for relieving loads coming on to structural members being repaired/strengthened
but excludes the cost of reinforcement.
chemical use BASF, Sunanda, Fosroc, Pidilite etc as per Approved by engineer
(Note:- Only Single Payment Consider For Same Work)
0mm To 25mm thickness 4.07 1208.00 S.M.
0mm To 50mm thickness 4.07 2348.00 S.M.
Providing Formwork of ordinary timber planking so as to give rough finish
including centering, Shuttering, Struting and propping etc. height of propping
16 and centering below supporting floor to ceiling nott excluding 4m and removal
of the same for Cast in situ reinforced concrete and plain concrete work
(G)Column, pillers, post and strusts
(i)Square rectangular polygonal in plan (upto 10 ton) 1.00 320.70 S.M.
Providing and applying cement mortar 1:4 enriched with expanding grout
additive in required proportion in cement for repair of cracks in RCC and non-
RCC members after making 25mm x 25mm groove, cleaning the surface and
applying coat of bonding, finishing smooth the repaired surfaces, providing and
applying curing agent on the repaired surfaces, etc. complete at all floor levels as
directed by engineer-in-charge. The make and quality of expanding grout
additives, bonding agent, curing agent, etc. shall be approved by the engineer-in-
charge. The procedure for application shall be strictly in accordance with
manufacturer's detail specification, which shall be submitted before start of work
and shall be approved by the Engineer-in-charge.
SOR 2024-25 & MR
Description Qty. Unit Amount
Carrying out Injection grouting for cracks in RCC structural members by drilling
holes of 15 mm diameter upto minimum depth of 75 mm, fixing aluminium
nozzle / rubber pipe using non-shrink epoxy putty, injecting epoxy grout material
specified pressure with grouting pump till it the material refuses to impregnate
inside the hole. If required or suggested by the Engineer-in-charge, injection
18 grouting shall be carried out more than once for a hole to assure proper spreading
of grout material and filling of capillaries / voids
within the element. After satisfactory injection grouting, the nozzle/pipe shall be
cut and sealed by non-shrink epoxy putty. The surface shall be finished smooth
with C:M (1:4) and reinstated to the original condition as directed by the
The rate shall include the cost of providing and supplying all tools, materials
,labour, scaffolding, props, formwork,etc.complete.The make and quality of
epoxy grout, epoxy putty, etc. shall be
approved by the Engineer-in-charge.The procedure for application shall be
strictly in accordance with manufacturer's detail
specification, which shall besubmitted beforestart of workand shall beapprovedby
theEngineer-in-charge. (Actual noof holes
and their locations shall be as decided by the Engineer-in-charge)
chemical use BASF, Sunanda, Fosroc, Pidilite etc as per Approved by engineer
Carrying out Injection grouting for cracks in RCC structural members by drilling
holes of 15mm diameter up to minimum depth of 75mm, fixing aluminium
nozzle/ rubberpipeusingcementitious
compound, injecting polymer modified slurry (SBR+cement+water)
1:1:1material at specified pressure with grouting pump till it the
material refuses to impregnate inside the hole. If required or suggestedby
19 theEngineer-in-charge, injection grouting shall be carried out more than once for
a hole to assure proper spreading of
groutmaterial and fillingof capillaries / voids with in theelement. After
satisfactory injection grouting, then ozzle/pipes hall becut and
sealed by non-shrinke poxy putty. The surfaces hall be finished smooth with
C:M(1:4) and reinstated to the original conditionas
directed by the Engineer-in-charge.
The rate shall include the cost of providing and supplying all tools, materials,
labour,scaffolding, props, formwork,etc.complete.The make and quality of epoxy
grout, epoxy putty, etc. shall be approved by the Engineer-in charge. The
procedure for application shall be strictly in accordance with manufacturer's 10.00 450.00 NOS
detail specification, whichshall besubmittedbeforestart of workand shall be
approved by the Engineer-in-charge. (Actual NOS of holes and their locations
shall be as decided by the Engineer-in-charge)
Providing and appliying thixotropic Making up lost section of concrete / mortor
with thixotropic repair mortor of one-component, normal-setting, shrinkage-
compensating, thixotropic mortar for layers up to 20 mm thick. Supply and
application of one-component, normal-setting, shrinkage-compensating
thixotropic mortar made from cementitious binders, selected aggregates, special
additives and synthetic polyacrylonitrile fibres, for reconstructing deteriorated
20 concrete structures. Apply the mortar after adequate preparation of the substrate
by removing all deteriorated concrete to form a sufficiently-rough, solid substrate
with no detached portions. Clean the steel reinforcement down to bare metal and
apply a passivating treatment by brush-applying two coats of one-component,
anti-corrosion cementitious mortar. Apply the product by trowel or spray with a
continuous-feed rendering machine on a clean substrate saturated with water in
layers up to 20 mm thick.
To improve expansion in the open air during the first few days of curing, add a
special curing additive when mixing the mortar to reduce both plastic and
hydraulic shrinkage at a dose of 0.25% in weight on the weight of the mortar.
The product must comply with the minimum requirements of EN 1504-3 for
structural mortars and have the following performance characteristics:
SOR 2024-25 & MR
Description Qty. Unit Amount
Compressive strength (EN 12190) (MPa):> 40 (after 28 days), Flexural strength
(EN 196/1) (MPa): 7 (after 28 days), Compressive modulus of elasticity (EN
13412) (GPa): 25 (after 28 days) Adhesion to substrate (EN 1542) (MPa):>
(after 28 days), Capillary absorption (EN 13057) (kg/m²•h0.5): < 0.20, Thermal
compatibility measured as adhesion according to EN 1542 (MPa): – freeze-thaw
cycles with de-icing salts (EN 13687/1): > 1.5 (after 50 cycles), Storm cycles
(EN 13687/2):> 1.5 (after 30 cycles), dry thermal cycles (EN 13687/4):>
(after 30 cycles), Reaction to fire (EN 13501-1) (Euroclass):1
Consumption (per cm of thickness) (kg/m²): approximately 18.5 Kg included
and calculated in the price for work carried out according to specification: (1)
hydro-cleaning of adhesion surfaces and saturation of substrate with water
immediately before applying the mortar; (2) application of the mortar by trowel
or spray around steel reinforcement; (3) levelling off surfaces with a straight edge
and final tamping; (4) careful curing of the mortar by spraying on water for at
least 7 days (3times) after application.
(Note:- Only Single Payment Consider For Same Work)
0 MM TO 25 MM THICK 4.50 1370.00 S.M.
0 MM TO 50 MM THICK 4.50 2460.00 S.M.
Pointing on brickwork with cement mortar 1:1 (1-cement : 1- coarse sand) (B)
Ruled pointing.
MASONARY & PLASTER WORKS
Masonary work using Aerated light weight concrete block having crushing
strength not less than 35 kg/sqcm for super structure above plinth level upto floor
two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as per
Technical Specification
Ground floor 0.00 4644.08 C.M.
First floor (Terrace Floor) 0.30 4689.24 C.M.
Providing 20mm thick double coat mala cement plaster on brick/concrete work
for plastering comprising of base coat 12mm thick cement plaster in cement
23 mortar (1Cement :4coarsesand) in rough finishing and 8mm thick top coat of
cement mortar1:2 (1Cement :2Coarsesand) finished with trovel including
scaffolding curing etc. complete
Ground Floor 30.47 286.10 S.M.
Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness consider)
Heavy Roller plaster on walls or similar surfaces at all floor levels consisting of
12 mm av. Th. Backing coat of C.M. 1:3 (1 cement:3 sand : racron 3s ( 0.5 nos
per bag )) also plaster master wterproofing chemical
ml /bags as per companey manual & approved by E.I.C or consultant & 8 mm.
th. Finishing coat of C.M. 1:1 (1 cement: 1 sand) apply thick cement slurry and
apply roller horizontal as well as vartical ( two times ) up to good quality and size
of grain in elevation as per directed by engineer incharge.
Outside All Floor Plaster 21.66 417.00 S.M.
Apply two coats of putty and two coats of primer of approved brand and
manufacture on new wall surface to give an even shade including thoroughly
brushing the surface free from mortar dropping and other matter and sand
papered smooth.
(A) for wall and similar surfaces 121.89 40.59 S.M.
Painting two coats of enamel paint over priming coat (including priming coat) on
wall after removing entire surface dirt, dust foreign matter & also incl. preparing
the surface even & sand papered smooth etc. comp.(M.R.)
SOR 2024-25 & MR
Description Qty. Unit Amount
Wall painting (two coats) with plastic emulsion paint of approved brand and
manufacture on undecorated wall surface to give an even shade including
27 throughly brushing the surface free from mortar droppings and other foreign 95.63 83.36 S.M.
matter and sand papered smooth.
Providing and applying two coats of weather shield max paint (3 coat may be
required in case of darker colours.) of ICI DULEX or Apex ultima of asian paint
including applying exterior acrylic primer coat as per manufacturers specification
and dirctions in shade and colour approved by architects, on exterior surface of
the building including scaffolding, preparing the surface, watering, curing etc.
complete and as directed by the architects and manufacturers. Surface
Preparation :Surface is throughly clean, dry and free from all loose dirt, chalk,
grease, fungi, algae and flaking paint. This can be achieved by brushing with a
28 wire / stiff coir brush followed by water jetting if required. Fill up all minor
cracks and defects with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint must be
throughly scraped off and Clean the surface throughly using wire brushes.
PRIMING:Apply a liberal coat of exterior acrylic primer and allow it to dry for 4-
5 hours. Application of putty is Not recommended. Minimum 4-6 hours duration
is required between each coat of weather shield max paint.
(A) For wall 121.31 82.00 S.M.
Providing & laying Vitrified tiles of 8mm thick of Orient, Kajaria, Jhonson,Nitco,
Somani, Bell, Asian or Euromake in flooring,treadsof steps & Landing laidonbed
of 20mm (Average) baseof cement mortar 1:6 (1 Cement : 6Coarsesand) on new
29 surface or fixing on existing flooring by adhesive material including dismentaling 0.00 1467.72 S.M.
of existing flooring and jointed with colour cement slurry including finishedwith
flush pointing & cleaning the surface etc. comp.Size 24" x 24" For Antiskid tiles
Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in skrting risers
30 of steps and dedo on 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) 0.00 1135.80 S.M.
and jointed with white cement slurry.
Providing and laying polished Kota stone slab flooring over 20mm (Average)
thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or
L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey
31 cement slurry mixed with pigment to match the shade of slab including 4.18 1019.39 S.M.
rubbing and polishing etc. complete. (A) 25mm thick
Providing and laying polished kota stone slab 25mm thick in risers of
steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1- Cement
32 : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match 2.38 1130.79 S.M.
the shade of slab including rubbing and polishing etc. complete.
Providing & laying granite slab 18mm thick in Window-Door seal Frame Etc laid
on 10mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) with nessary
33 adhesive material and finished with flush pointing in white or colour cement, 0.84 2026.00 S.M.
including rubbing & polishing comp.. (Basic Rate:- Rs.1000.0/S.M.).)
Providing& laying granite slab 18mm thick inflooring, treadsof steps and landing
laid onbedof 20mm thick cemen mortar 1:6 (1Cement : 6 coarse sand)or lime
34 mortar1:1.5 laid and finished with flush pointing in white or colour cement 1.93 2410.00 S.M.
including rubbing and polishing complete. (BasicRate:
Providing& laying granite slab18mm thick in skirting, risers of steps, dedo and
pillars laid on10mm thick cement mortar 1:4 (1Cement :
Coarse sand) and finishedwith flush pointing inwhite or colour cement including 0.96 2449.00 S.M.
rubbing & polishing comp.. (Basic Rate:- Rs.1347.46/S.M.)
SOR 2024-25 & MR
Description Qty. Unit Amount
Providing & Laying white glazed tiles 6mm. th. of Orient, Kajaria,
Jhonson,Nitco,Somani ,Bellmakeat all floor levels, in flooring, treads of steps &
landings laid on a bed of 12mm. Av.Th.C.M.1:3 (1cement :3sand) finished with
flush pointing in white cement etc.com. For all floors
Providing & Laying white glazed tiles 6mm. th. Of Orient, Kajaria,
Jhonson,Nitco,Somani,Bell make at all floor levels in skirting risers of steps &
37 dado on 10 mm. th. C.M.1:3(1cement :3 sand) including necessary cement paste 1.53 932.02 S.M.
for fixing and joined with white cement slurry etc. complete. For all floors
38 Labour charges for edge finishing for granite 30.02 43.43 R.M.
WATERPROOFING WORKS
NOTE :- (1) The whole work is to be executed through specialized agency with a
guarantee of 10 (Ten) years given on a prescribed proforma duly stamped (2)
The rate shall include for work at all floors & conducting water proof test as
directed. (M.R.)
(B) Providing and laying integral cement based water proofing treatment
including preparation of surface as required for treatment of roofs, balconies,
terraces etc. consisting of following operations.
(a) Applying and grouting a slurry coat of neat cement using 2.75 Kg./sqm of
cement admixed with proprietary water proofing compound comforming to
IS:2645 over the R.C.C. slab including cleaning the surface before tratment.
(b) Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm
size with 50% of cement mortar 1:5 (1 Cement : 5 Coarse sand) admixed with
proprietary water proofing compound conforming to IS:2645 ,brick bats is finally 46.00 511.00 S.M.
covered by jointless cement plaster 20mm th. in C.M. 1:4 added with special
water proofing compound confirming to IS:2645 & top smooth finished with
trowel with false chequered marking of 300 mm.size.The treatment is carried
along the vertical surface of the parapet & other adjoining wall up to height of
about 300 mm in a shape of quarter round vata Incl. curing etc. Comp. With
average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying broken China mosaic flooring for terrace using 12 mm to
20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or
slope and to be tempered to bring mortar crème out upto surface using white
40 cement including rounding off junctions and extending them upto 15 C.M. along 46.00 779.70 S.M.
the wall, clearing with water and oxalic acid etc. as directed.
WATER SUPPLY & SANITARY WORKS
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 110x110 mm
diameter with jali of the following nominal diameter of self cleaning design with
41 C.I. scread down or hinged grating including the cost of cutting and making
good the walls.
All floor 2.00 586.27 NOS
Providing & fixing U-PVC pipes Confirming to ISno. 13592 (Type"A") of
Prince/ Supreme/Jain/Astral/ Tulsi/Finolexmake for rainwater at all floor
levels incl. fixtures likebends, tees, shoeetc joined with resin of approved brand
& manufacture etc. comp. (M.R.)
Providing & Fixing U-PVC pipe (SWR) confirming to IS NOS 13592 (Type "B")
of Prince/Supreme/Jain/Astral/Tulsi/FiNOSlex make for soil and waste discharge
43 system at all floor levels incl. All fixtures like bends, tees, shoe etc. jointed with
resin of approved brand & manufacture etc. comp.
44 Providing & fixing G.I. Rain water spout of 50 mm dia & 30 C.M. length etc.
SOR 2024-25 & MR
Description Qty. Unit Amount
All floors level 1.00 101.91 NOS
Providing and constructing simple chamber with 23C.M.. th. brick masonary
walls in c.m. 1:5 with cement plaster 15mm. thick in c.m. 1:3 inside and outside
to exposed faces,R.C.C. top slab with 1:2:4 mix,foundation concrete 1: 5:10 and
45 fixing C.I. cover with frame to be NOSt less than 38 Kg.. on top etc. comp.
Inside dim. 455 X 610mm X 450 mm deep for single pipe.
(A) Same as above but Precast RCC heavy duty Cover instead of C.I. Cover.
46 Extra for every additional depth of 0.1 mt beyond 0.45 mt. 3.00 242.39 NOS
Prov.& Fixing water closet squatting pan (Orissa type W.C.pan) at all floor
levels, size 500mm x 400 mm incl. 100 mm size "P'or "S" trap for water closet
47 squatting pan joining the trap with the pan & soil pipe in C.M. 1:1 (1cement :1 1.00 3277.39 NOS
fine sand) etc. Comp.(A) Vitreous china long pattern
Make- Cera S3010109, Jaquar ,HindWare
Providing & fixing Wash Hung basin with single hole for pillar tap , Size- 550 x
48 400 mm at all floor levels, with C.I. or M.S. Brackets painted white incl. cutting
holes & making good the same etc. complete. For all Floor
Make- Cera Cat. No. S2040121, Jaquar SLS- WHT -6801,HindWare10004
Providing & Fixing 15 mm Dia bib tap with wall Flange at all floor levels,
polished bright etc. comp.
Make- Cera F2013151 BIB COCK, HindWare F280002 BIB COCK, Jaquar FLR-
5047 N BIB COCK
Providing flush cock consisting lever, cartridge sleeve & flange & concealed part
Make- Cera EXPOSED PART F2013751 &Concealed part F4060101
Jaquar FLR 5083 KN , CONCEALED BODY ALD-081,HINDWARE
F730013 & CONCEALED STOP COCK F850095
Providing & fixing C.P. brass pillar cock with copper connection, C.P. brass
screws complete
Make- Cera F2013101, HindWare Cat. No.: F650003, Jaquar FLR- 5011N
Providing & fixing 15mm C.P. brass angle valve (Stop Cock) with C.P. copper
connecting pipe 450 mm long and nuts, washer and brass flange complete,
52 including cutting and making good the wall where
Make- Cera F1020362, HindWare Cat. No.: F440020 F850094,
jaquar CON 053 KN
Providing & Fixing P.V.C. pipes (SCH-80) of Prince/ Supreme/ Jain/ Astral/
Tulsi/FiNOSlex make for water supply line at all floor levels incl. fixtures like
bends, tees, shoe etc joined with resin of approved brand & manufacture etc.
53 comp. Pipe shall be fixed on the wall the help of clamp at every two meter C/C or
shall be concealed as directed including necessary fittings etc. including testing of
pipe and joints and fixing the same with adhesive solvent, including cost of all
Providing & Fixing gun metal check or NOSn return full way wheel valve at all
floors levels, etc. complete. (A) 15 mm. dia.
Providing & Fixing abonite ball cock of approved qualities directed etc. comp.
SOR 2024-25 & MR
Description Qty. Unit Amount
Providing & Fixing in position PVC Cowl vent to pipes of
56 Prince/Supreme/Jain/Astral/Tulsi/Finolex make etc.Comp. (A) 75 mm. dia. 1.00 40.00 NOS
(B) 110 mm Dia. 1.00 50.00 NOS
Providing & Fixing Kathi around the vertical PVC drainage pipes for concealing
57 with cement plaster 20 mm avg thickness(C.M. 1:3 [1 cement :3 coarse sand])
finishing as per instruction given by Eng. incharge. MR
(A) 75 mm PVC PIPE 3.00 173.00 R.M.
(B) 100 mm /110 mm PVC PIPE 3.00 180.00 R.M.
Providing & fixing Z - clamps at all floor levels of approved design to C.I. S.C.I.
58 or PVC pipes including the cost of cutting holes & making good the wall etc.
Complete - 100 mm dia as per architect instructions
(A) 40 to 50 mm dia 6.00 62.00 NOS
(B) 75 to 90 mm dia 6.00 75.00 NOS
(C) 110 mm dia to upto 150 mm dia 6.00 90.00 NOS
Removal of Sintex tank with all fittings and refixing at same location but on the
pedastal of 0.3m height from slab level with all necessary fittings and fastenings
as per requirements and as per directions of engineer in charge. As per M.R.
(1000 lit to 10,00 Lit. any size od Tank)
Providing erecting and fixing double coated Sintex/Super/Reno PVC (ISI) mark
60 water tank of required capacity each with all necessary fittings & 1000.00 3.95 Lits
connection etc. complete on terrace. (sintex tank 10000 lit.)
61 Vegetation Removal from building 1.00 1500.00 JOB
Providing & Fixing M.S.Grills of required pattern to wooden frames of windows
etc. at all floor levels with M.S.flats at required spacing & frame around square or
round bars with round headed bolts & round heade bolts and nuts or by screws
incl. Priming coat of Red lead paint etc. comp.
Apply hacking on RCC member manual or by mechanical as discoused by
engineer incharge. 350 - 400 notches (dents)
per sqmt. Process of making the back ground rough before plastering for better
bonding of mortar with RCC (Tacha)
Providing & fixing 35mm.th. Flush Door Solid Double Core type Both Face
water proof Ply Vennered & 1.5 mm th.laminate shall be pasted on both side
with adhesives as specified by the manufacturers. The laminate shall be as per
64 approved shade & texture, of make incl. Sal wood frames of finished size 12cm x 0.00 3720.00 S.M.
7cm.incl. S.S. Hinges with nessary screws & Anodized aluminum fixtures &
fastenings For all Floor
Same as Above But Without Frame 1.60 2520.00 S.M.
Carrying out wall treatment for termite control including spraying with chemical
solution in oil base including labour and material Using Chlorpyriphos 20 ECAs
per IS 6313 part - II (1% concentration by mass) is recommended i.e one litre
65 chemical emulsion diluted 37.00 24.90 S.M
with 19 liter oil base. Total solution will be 20 liters inclusive of one liter
chemical emulsion application at the rate of 7.5 litre chemical / Sqm of surface is
recommended as per I.S.
Providing & Fixing Nylon net (having net weight-0.065 kg/sq.mt) in
66 outside as well as inside plaster / terrace water proofing etc as direct by 52.13 32.00 S.M.
Providing and Replace door, Window S.S. Fixtures fix in wooden /
67 Alluminium door - window with ISI marks as per approoved by engineer in
(A) 4" S.S. Hinge 16.00 125.00 Nos.
(B) 5" S.S. Hinge 9.00 150.00 Nos.
(C) 8" S.S. Aldraf 2.00 180.00 Nos.
(D) 10" S.S. Aldraf 0.00 210.00 Nos.
(E) 12" S.S. Aldraf 0.00 240.00 Nos.
(F) 4" S.S. Handle 4mm. Th. 10.00 150.00 Nos.
SOR 2024-25 & MR
Description Qty. Unit Amount
(G) 6" S.S. Handle 4mm. Th. 0.00 180.00 Nos.
(H) 4" S.S. Stopper 4mm. Th. 10.00 125.00 Nos.
(I) 8" S.S. Stopper 4mm. Th. 1.00 175.00 Nos.
(J) 6" S.S. Pavan Ankdi Heavy duty 10.00 100.00 Nos.
Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar
1:1 including neat cement finishing, watering etc. complete.
Ground Floor 4.68 24.28 R.M.
Terrace floor 44.94 24.28 R.M.
"Providing and laying FRP (Fiber Reinforced Plastic) chhajja over doors,
windows and building extensions, factory-moulded with glass-fiber
reinforcement and resin matrix, UV-stabilized, weather-resistant, including
MS brackets, anchor fasteners, anticorrosive painting, sealing of joints, and
complete installation as per specifications and Engineer-in-Charge."
Providing – supplying & fixing top & bottom aluminum frame (50 x 25)
0.95 mm thick & central lock frame with ( 75 x 25 ) 1.03 mm thick color
70 anodized with 4 mm thick ACP (Exterior grade plain colors) with 1.60 2580.00 S.M.
aluminum anodized aldrop, stopper & fixing with S.S screws etc all per
directed by engineer in charge.
Providing & fixing G.i mesh 25X25X3mm used for celling repair fixed
71 with celling rebar column as per directed by enginner incharge rate 5.00 546.00 S.M.
excluding the rebar cost .
RCC Core Cutting is about making precise, circular cuts for creating holes
of required diameters for Rehabilitation in civil
72 works. The core drilling rod is fitted with diamond pieces at the drilling
end. The core cutting machine can be used for
both horizontal and vertical hole making purposes.
73 Polishing flooring after repair work done as direct by E.I.C 41.83 172.00 S.M.
Providing and Fixing Hollow steel Sections Framed Work including
74 Cutting, Hoisting,Welding & Fixing in position Purlin, Main Chord etc.as 50.00 126.00 Kg.
per Engineer in-charge.TATA / JINDAL / ASIAN Make
Providing and fixing rebar of following diameter using chemical grout of
Swanchore/Hilti/Fischer or equivalent make including cost of all
equipments, tools, material, labour, etc. Standard procedure as mentioned
in manufacturer's specifications shall be strictly followed, which shall be
submitted and got approved from the authority prior to start of work. The
rate shall also include cost of drilling of hole of required diameter and
75 depth as mentioned in manufacturer's specification, cleaning the hole with
blower and other necessary tools and tackles, positioning, providing and
grouting chemical, allied fixtures and fasteners, etc. but excluding the cost
of reinforcing bar etc. complete. Item includes necessary scaffolding,
staging, labour, tools and equipments, etc. complete as directed by the
engineer-incharge.
Decorative wall paintings with designing, painting at place with all necessary
76 material surface preparation , primer application 2 coats of weather coat paint 300.00 40.00 Sq.ft.
artwork creation including labour
SOR 2024-25 & MR
Description Qty. Unit Amount
Slogan writing on walls designing, painting at place with all necessary matirials
77 surface preparation, primer application 2 coats of whether coat paint, artwork 100.00 30.00 Sq.ft.
creation including labour
Vinyl Sticker any size 1. Eco Solvent vinyl
sticker (120 gsm) with laminate (100 gsm)
Vinyl Sticker any size 2. Solvent vinyl sticker
(120 gsm) with laminate (100 gsm)
80 5 mm PVC sheet Eco vinyl any size 25.00 52.00 Sq.ft.
PART B :- GROUND DEVELOPMENT + COMPOUND
1 Removing Paver block flooring 110.00 10.10 S.M.
Box Cutting the road surface to proper slope and camber for making base
2 includinng removing the excavated stuff and depositing on the road side 18.00 109.41 C.M.
slope as directed up to 50 mt. lead.
Providing & laying cement concrete Pavement using M30 concerte &
3 Vaccuum Dewatering technique including floating surface with a skim 17.00 6548.83 C.M.
powder floater, curing etc. complete.
Providing & fixing IS Mark TMT Bar FE 500 / FE 500D reinforcement for
R.C.C. work incl. bending, binding & placing in position etc. comp. Upto
Providing & filling in plinth with yellow soil or selected soil in layers of
cm. Th'. Incl. watering, ramming & consolidation etc. complete.
Preparation of subgrade with Compacting, Levelling and consolidation of
subgrade with miniroller/plate vibrator machine including watering and
filling in depressions which occur during the process as directed by
engineer-in-charge.
Providing & laying Granular sub base (GSB) confirming to Grading-II of
Table 400.0 of compacted thick of 150mm with specified graded stone
metal and sand mixed in place and laid with mechanical means spreading
7 with motor grader and compacting with vibratory roller having minimum 12.00 1469.00 C.M.
80-100 KN static weight to acheve desired density of 98% of MDD
including all material, labour, machinery with all leads and lift etc.
Providing and laying 200 micron plastic sheet on prepared sub base For
Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 Crushed stone
9 agg 20m.m Nominal size)&curing comp. excl. cost of form work in :(a) 10.00 3095.25 C.M.
foundation & Plinth
Supplying & filling fine sand (pana) in 150 mm compacted thickness over
the base including necessary compaction, watering etc. complete. Item
includes leveling by using vibratory plates compacted machine and as
directed by engineer in charge.
Providing & fixing interlocking type Cement Concrete paver block of
approved shape & design having 80 mm thickness (M-50) purchased from
SMC's approved paverblock manufacturer only on fine sand bedding. Item
includes leveling by using vibratory plates compacted machine. Item also
includes all materials, Labour, euipments, tools, plants, watering, cleaning
SOR 2024-25 & MR
Description Qty. Unit Amount
Cutting of Groov 5.00 mm wide in VDS for depth of 250.00 mm of total
thickness making bays of 4.0 mtr x 4.0 mtr. Using groove cutting machine
with diamond cutting wheel and filling of sealent etc. complete as per
directed by Engineer in-charge
Providing 100mm thick readymade C.C. kerb of strength M-20 (size
300mm x 380mm) purchased from SMC's approved paverblock
manufacturer &setting in line, level and in truly vertical position, including
filling joints in C.M. 1:1 (1 part of cement : 1 part of stone dust) smooth
pointing in C.M. 1:1 (1 part of cement : 1 part of coarse sand) including
watering etc. complete and as directed by engineer in charge.
For rounding at the edge of footpath (For fanning portion) 10.00 274.00 R.M.
Demolishing Brick work and stone masonry incl. including stacking of
14 serviceable material and disposal of unserviceable material with all lead 5.00 577.92 C.M.
and lift. (ii) In cement mortar
Removing the scraping of old deteriosted plaster of any thickness form
wall/R.C.C. member including strcking of serviceable material and
disposal of unserviceable material from site of work with all lead and lift.
Including Scafholding
Masonary work using Aerated light weight concrete block having crushing
strength not less than 35 kg/sqcm for super structure above plinth level
upto floor two level in cement mortar 1:5 ( 1 cement : 5 fine sand )
complete as per Technical Specification
Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness
consider) Heavy Roller plaster on walls or similar surfaces at all floor
levels consisting of 12 mm av. Th. Backing coat of C.M. 1:3 (1 cement:3
sand : racron 3s ( 0.5 nos per bag )) also plaster master wterproofing
17 chemical 100ml /bags as per companey manual & approved by E.I.C or 128.25 417.00 S.M.
consultant & 8 mm. th. Finishing coat of C.M. 1:1 (1 cement: 1 sand) apply
thick cement slurry and apply roller horizontal as well as vartical ( two
times ) up to good quality and size of grain in elevation as per directed by
engineer incharge.
Providing and applying two coats of weather shield max paint (3 coat may
be required in case of darker colours.) of ICI DULEX or Apex ultima of
asian paint including applying exterior acrylic primer coat as per
manufacturers specification and dirctions in shade and colour approved by
architects, on exterior surface of the building including scaffolding,
preparing the surface, watering, curing etc. complete and as directed by the
architects and manufacturers. Surface Preparation
:Surface is throughly clean, dry and free from all loose dirt, chalk, grease,
fungi, algae and flaking paint. This can be achieved by brushing with a
18 wire / stiff coir brush followed by water jetting if required. Fill up all minor 256.50 82.00 S.M.
cracks and defects with white cement and sand mixture in the ratio 1:3. For
application on previously painted wall, previous coatings of paint must be
throughly scraped off and Clean the surface throughly using wire
brushes. PRIMING:Apply a liberal coat of exterior acrylic primer
and allow it to dry for 4-5 hours. Application of putty is Not recommended.
Minimum 4-6 hours duration is required between each coat of weather
shield max paint.
Providing and fixing and fitting TATA or Jindal make G.I. barbed wire
fencing with necessary barbed wire (12 x 14 guage, weight not less than
0.14 kg. / mt.) pins, hooks, excluding M.S. angles etc. complete as per
relevent IS specification.& directed by engineer in charge
Steel work welded in built up sections, framed work including cutting,
hoisting, fixing in position and applying a priming coat of red lead paint
(A) in beams & joists channels angles, tees, flats with connection plates or
angle cleats as in main & cross beams,hip & trussed purlins connected to 2.00 9108.48 Qtl.
common raffers & the like.
SOR 2024-25 & MR
Description Qty. Unit Amount
Applying Priming coat over new steel and other metal surface after over
and including preparing the surface by throughly cleaning oil, grease dirt
21 and other foreign matter and scoured with brushed fine steel wool, scrapers 5.00 36.74 S.M.
and sand paper with ready mixed priming paint brushing red lead.
Painting two coat (excluding priming coat) on new steel and other metal
22 surface with synthetic enemal paint, burshing to give an even shade 5.00 68.57 S.M.
including cleaning the surface of all dirt, dust and other foreign matters.
PART C :- ELECTRICAL WORKS
Part-01 Point wiring in Copper (MODULAR)
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length , in below type of pipe
erected with 6A Modular type switch / bell push & accessories and earth
1 continuity of following type, erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (green) both are of ISI marked 1.1 KV grade ZHFR PVC
insulated multi strand copper wires, in below type of pipe to be erected
complete with earth continuity and necessary connection with primary light
with accessories erected on Metal / PVC / wooden box covered with
mm thick PC(Polycarbonate) / Acrylic sheet for open / concealed wiring.
with necessary Lamp holder / ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of .ISI marked 1.1 KV Grade ZHFR PVC insulated multi
strand copper wires up to 10 mtr length, in below type of pipe erected
with 6A Modular type switch and hum free EME step type electronic fan
3 regulator mounted and accessories with earth continuity of following type
erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in
wall / ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
Cat. III 0.00 670.24 Pt.
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Cat. III 3.00 708.41 Pt.
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade ZHFR PVC insulated multi strand
copper wires up to 10 mtr length, in below type of pipe erected complete
4 with Modular type switch & 5 pin Plug erected on PVC /
Metallic/Wooden box covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
SOR 2024-25 & MR
Description Qty. Unit Amount
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Cat. III 2.00 535.55 Pt.
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade ZHFR PVC insulated multistrand
copper wires, in following type of to be erected concealed in / on surface of
wall / ceiling complete with Modular type switch & 5 pin Plug erected on
PVC / Metallic box covered with appropriate front plate modules erected
on / in wall / ceiling as per pipe erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Cat. III 2.00 782.65 Pt.
Point wiring for on board Looped Plug with 6A Modular type switch &
pin socket erected on PVC / Metallic/Wooden box, single mounting base
frame covered with textured / metallic/white front plate modules erected
on / in wall / ceiling with following type accessories
Conduits & Pipes
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved manner as directed
Providing & erecting PVC Corrugated Flexible Conduit with required
9 nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. 20.00 17.17 Mtr.
Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping)
having double-locking arrangement with grooves, trunking of size not
10 below 12.5 mm in height as per IS with accessories of PVC/Resin 5.00 31.31 Mtr.
polypropylene not below 1.8 mm thick duly sealed in joint & erected on
wall / ceiling of following size .(2) 25 mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC
insulated stranded wire of green colour for earth continuity of following
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm 50.00 62.62 Mtr.
(b) 2 wire 2.5 sq. mm 50.00 82.82 Mtr.
(C) With oval conduit /PVC casing capping double lock type
(a) 2 wire 1.5 sq. mm 20.00 56.56 Mtr.
12 (b) 2 wire 2.5 sq. mm (From LDB to SB and SB to SB ) 30.00 82.82 Mtr.
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded
Copper conductor wire in following type of pipe to be erected in / on wall /
13 ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size (C) with oval
conduit /PVC casing capping double lock type
(a) 2 wire 4 sqmm 10.00 112.11 Mtr.
(g) 4 wire 4 sq. mm 5.00 180.79 Mtr.
(b) 2 wire 6 sq. mm 5.00 147.46 Mtr.
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable
1.1 KV grade to be erected as directed of following size.
(E) 3 core 2.5 Sq. mm 50.00 137.36 Mtr.
Part-02 LT Switchgear, Distribution Boards & LT Panel
SOR 2024-25 & MR
Description Qty. Unit Amount
Providing and erecting Sheet Steel powder coated MCB distribution board -
flush / surface mounted fitted with busbar, neutral link, earth bar and DIN
15 rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of
MCB to be used) suitable for
(A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43)
providing and erecting Approved make RCCBs conforming to IS:
and having sensitivity of 30 mA and Short Circuit withstand capacity of
KA and suitable for operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected as
directed (i) 25 Amps.DP Cat. III
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI
Providing & erecting 240 V MCB double pole switch for motor &
18 inductive load (C Curve) having 10 KA breaking capacity & confirms to
IS : 8828 in existing box having following capacity
(A) 6 to 32 Amp.
Cat III 2.00 299.97 Ea.
sheets Steel powder coated enclosure suitable for incorporating One/Two
Providing and erecting metallic vitrified danger notice board as per
20 language suggested by engineer incharge for MEDIUM VOLTAGE 2.00 69.69 Ea.
installation to be erected as per IS-2551.
Solder less crimping type Copper lugs conforming to IS suitable for cable
of following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
Part-03 Indoor Lighting Item
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/
aluminium die cast powder coated and high U.V. & corrosion resistance
with diffuser with company mark/name 160V to 270V, Power Factor more
22 than 0.9, THD < 15%,
CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet 10.00 373.70 Ea.
Supplying and erecting led lamps with following wattage capacity of
to 240 voltage, minimum 15000 burning hours life, 500 V in built-surge
23 protection,Polycarbonate diffuser, mounting suitable for E14 / E27 / B22
lamp holders, pf >=
(A) LED Lamps integral type, with PC diffuser suitable LAMP holder
(ii) 5 to 8 watts 2.00 112.11 Ea.
SOR 2024-25 & MR
Description Qty. Unit Amount
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or embossed 160 to
270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must
have 440VAC line supply with over-voltage protection.
(i) above 36 to 48 watts
Cat-lll 2.00 3345.12 Ea.
Part-04 Fan & Accessories
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan
with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz
25 1200 mm sweep complete having 3blades with aluminium blades with , 3.00 1948.29 Ea.
canopy & 30 cm. down rod erected with earthing. (Make shall be approved
by Engineer in charge)
Supply, Installation, Testing and Commissioning of suitable sweep, BEE
Star rated, Ceiling fan with Brush Less Direct Current (BLDC) permanent
ferrite magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium
blades, 2 nos. canopies, shackle kit with earthing provision, copper
winding, Power factor not < 0.9, Service Value (CMM/W) minimum 6.85,
Air delivery minimum 215 CMM, 350 RPM,230v (tolerance as per IS : 374-
26 2019), THD < 10%, with remote unit for Speed Control and all remaining 2.00 2885.57 Ea.
accessories including safety pin, nut bolts, washers, temperature rise =
degree C (Max.), suitable for 140 to 285 Voltage and rectifier circuit with
surge, over current and overload protection , 50 Hz, Single phase AC
Supply, earthing etc. Complete as required.[ Make shall be approved by
Engineer in Charge] (B) 1200 mm Sweep (48")
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe
27 down rod erected duly painted for fan complete with proper insulation 3.00 108.07 Mtr.
without leckage and earthing.
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to
the RCC bars up to 50mm length each side and pierced through a
Gauge M.S. box / Heavy Duty PVC box complete erected concealed in
Ceiling with necessary finishing.
Supplying & erecting single phase approved make industrial exhaust fan
29 suitable for medium duty ring mounted low noise operation suitable for
medium duty having following dia size and maximum speed in RPM
[A] 305 mm dia 900 RPM Cat.II 1.00 2054.34 Ea.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan
Part-05 Earthing System
Providing and erecting required size HOT deep Galvanised iron strip for
31 earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. 5.0 77.77 Kg.
using proper clamp.
SOR 2024-25 & MR
Description Qty. Unit Amount
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising,
connection terminal dia of 14 mm with constant ohmic value surrounded
by highly conductive compound with high charge dissipation suitable for
following type of applications with chamber and heavy duty cover
32 (A)(approved make OEM has to submit test certificate including value of
earth resistance of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing resistane mentioned in
test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-
2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must be submitted by
[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr 1.0 5842.85 Ea.
Back filling compound - 1 Nos. of Bag of 15 Kgs.
33 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 1.0 794.87 Kg.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long 'B'
grade G.I. pipe with necessary coupling buch buried in specially prepared
earth pit & G.I. earth wire of 8 SWG erected & connected as directed (For
36 For using salt and charcoal / coke as required for pipe type earthing. 2.0 171.70 Ea.
Supplying & erecting funnel type earthing having earth plate of following
size burred in specifically prepared earth pit 3 mtr. below ground with
kg. charcoal and salt with alternate layers of charcoal & salt, 20mm.dia.
G.I. pipe with Funnel with a wire mesh for watering & bricks masonry
block, C.I. Cover complete as per para 7.3 of IS 3043 with necessary length
of double Galvanised Iron / copper earth wire No 6 SWG bolted with lug to
the plate and covered in 12 mm dia. G.I. pipe 2.5 mtr long complete
connected to the nearest switch gear with end socket as per direction &
duly tested by earth tester confirming to IS (As per drawing) with
following specification
(A) With 30 x 30 x 0.35 cms: C.I. earth plate 1 2311.89 Ea.
38 ABC TYPE FIRE EXTINGUISHER :-
6KG CAPACITY 1.00 1,896.02 NOS
(MAKE:- SAFEX / KANEX / V-SAFE)
39 CO2 TYPE FIRE EXTINGUISHER :-
4.5KG CAPACITY 1.00 4,740.06 NOS
(MAKE:- SAFEX / KANEX / V-SAFE)
G.I. "C" CLASS PIPE AS PER IS 1239 WITH PAINTING
(1 COAT OF ZINC OXIDE PRIMER AND 2 COATS OF PO RED
PAINT), SUITABLE TYPES OF SUPPORTS, HILTI FASTENERS,
BOLTS, NUTS (GALVANISED), CLAMPS, "U" BOLTS, FITTINGS
SUCH AS REDUCERS, TEES, ELBOWS, FLANGES. INCLUDING
CUTTING, WELDING, FIXING IN/ON WALLS, (MAKE:- ASIAN /
50MM DIA 20.00 929.11 MTRS
Part-07 Motor, Pumps & Starter
Providing & erecting open well type horizontal mono block pump set with
stainless steel body having following specification
(C) 1 H.P. single phase open well motor pump set suitable for 185 LPM
discharge @ 25 mtr. head, suitable for 32 mm dia. Delivery pipe with 0 9613.18 Ea.
SOR 2024-25 & MR
Description Qty. Unit Amount
Providing & erecting open well horizontal mono block pump set with cast
iron body, complete for three phase submersible motor having
[A] For 1.5 HP 3 phase open well horizontal mono block pump set suitable
for 190 LPM @ 20 mtr head suitable for 40 mm dia delivery pipe 1 10284.83 Ea.
Supplying and erecting Direct On-line Electronics Starter with 2-5/4-10/8-
14/10-16 Amp. Rating relay (variable current setting) directly operated in
totally insulated elegant enclosure and 18 Amp. Rating power relay with
start - stop button for single phase operation up to 3 HP as per complete
43 erected on P.W. Block with following features. 1 1603.88 Ea.
Low voltage cut off below 140 V
High voltage cut off above 280 V
Overload protection
Indicating LEDs for motor on lv, hv & overload tripping. [Cat.II]
Supplying & erecting approved make Automatic liquid level controller
6A.as per instruction of Engineer in charge on site complete with wiring
connection with existing wires , with copper conductor from pump to
upper and lower tank.
Supplying & erecting approved make self-priming domestic monoblock
water pump with 1 H.P motor, suitable for operation on 230 volts, 50c/s.
45 AC supply with metallic flange, and M.S. impeller delivery and following
(a) 40 LPM at 24 mtrs. head suitable for 25mm dia. Delivery Cat.III 1 7679.03 Ea.
S.I.T.C. of single phase submersible pump set suitable for 100 mm size or
more dia bore well having motor capacity and discharge as under with
necessary panel box. Lifting and Lowering taken extra.
(a) Motor rating 1 HP (12 stage) pump having capacity of 50 LPM at 43 to
45 mtr head suitable for 32 mm dia. delivery pipe
Cat.II 0 15595.41 Ea.
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat
47 flexible Submersible copper cable approved make of following Size.
(A) 3 Core x 1.5 Sq. mm. 50 65.65 Mtr
Part-08 Water Cooler & Purifier
Providing and erecting water cooler having storage capacity 80Ltr. &
cooling capacity 40 Ltr.per hour @ an ambient temp of 450 C. The outlet
temp. of the water should drop by 150 C within a hour, The water cooler
47 should be comprising of hermetically sealed compressor, fan motor, 1 49559.69 Ea.
condensing unit, water tank surrounded by evaporating coil, thermostats,
relay etc. complete with necessary inlet & outlet connection. The body of
water cooler will be made from Stainless Steel.
SITC of Water Purifire Eureka Forbs Make AG 200 or Equivalent 1 10605.00 Ea.
Supplying and erecting water filter cum purifier with ultra violate
48 technology. (Aquaguard / waterdoc model or equivalent symphony/ 1 5424.71 Ea.
crystal/videocon model)
Part-09 Other Work
Supplying & erecting approved make SMC press moulded composite
FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite
connector strip 5way(3P+N+E),DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements with mounting
clamp with nuts, bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box.
(B) 250mm x 200mm x 100mm [deep] 2 515.10 Ea.
SOR 2024-25 & MR
Description Qty. Unit Amount
Providing and erecting street light pole bracket comprising main B Class
MS pipe of 4.2 cm/require outside dia. complete with suitable B Class
M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm /
80mm. / require size pole top having sufficient fasteners for fixing the
brackets and having spread of 1 mtr. length with suitable rise as per site
condition & suitable welded stiffener reducer and nipple with check nut
complete painted with one coat of Red oxide / PU base primer and two
coats of Aluminium / PU paint. paint with following nos of arms.
[A] Single Arm bracket 1 Mtr 2.00 561.56 Ea.
Supplying and erecting HYLAM sheet on existing angle iron frame.for
following thickness
TOTAL (A) ANGANWADI AT BHARTHANA-3
(B) ANGANWADI AT LAL TAMBU KOSAD VILLAGE
PART A:- REPAIR + REHABILITATION
1 Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness
consider) Heavy Roller plaster on walls or similar surfaces at all floor
levels consisting of 12 mm av. Th. Backing coat of C.M. 1:3 (1 cement:3
sand : racron 3s ( 0.5 nos per bag )) also plaster master wterproofing
chemical 100 ml /bags as per companey manual & approved by E.I.C or
consultant & 8 mm. th. Finishing coat of C.M. 1:1 (1 cement:1 sand) apply
thick cement slurry and apply roller horizontal as well as vartical ( two
times ) up to good quality and size of grain in elevation as per directed by
engineer incharge
up to plinth level 12 417.00 S.M.
WORK ABOVE PLINTH LEVEL
2 Providing, mixing, placing, compacting by machine vibrator,
curing, testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost of
form work and rendering but excluding cost of reinforcement. (With using
plastisizer compulsory)
(A) foundation, footing, base of columns and mass concrete
For Sintex Tank (Upper Terrace) 1 4413.60 C.M.
3 Providing, mixing, placing, compacting by machine vibrator,
curing, testing M25 Design mix concrete as per IS 456:2000 (latest
revision) and as per tender specification in all items including cost of
form work and rendering but excluding cost of reinforcement. (With using
plastisizer compulsory)
(1)Having c/s area up to 0.08 s.mt
Ground Floor 0 12930.68 C.M.
First Floor (Terrace Floor) 0 12971.23 C.M.
(2) c/s area more than 0.08sq. mt. & upto 0.12 sq.mt
Ground Floor 0 11253.32 C.M.
First Floor (Terrace Floor) 0 11293.87 C.M.
(3) Having cross sectional area more than 0.12 sq. mt.
Ground Floor 0 9288.03 C.M.
First Floor (Terrace Floor) 0 9328.58 C.M.
(1)Having c/s area up to 0.08 s.mt
Ground Floor 0 9083.57 C.M.
First Floor (Terrace Floor) 0 9124.12 C.M.
(2) c/s area more than 0.08sq. mt. & upto 0.12 sq.mt
Ground Floor 0 8155.37 C.M.
First Floor (Terrace Floor) 0 8195.92 C.M.
SOR 2024-25 & MR
Description Qty. Unit Amount
(3) Having cross sectional area more than 0.12 sq. mt.
Ground Floor 0 7067.84 C.M.
First Floor (Terrace Floor) 0 7108.39 C.M.
2) Slabs having more than 8cm. and upto 10 cm. Th'.
Ground Floor 0 7965.38 C.M.
First Floor (Terrace Floor) 0 8005.93 C.M.
(3) Slabs having more than 10 cm. & upto 13 cm. Th'.
Ground Floor 0 7377.92 C.M.
First Floor (Terrace Floor) 0 7418.47 C.M.
4) Slabs having more than 13 cm. Thickness
Ground Floor 0 6793.97 C.M.
First Floor (Terrace Floor) 0 6834.52 C.M.
Ground floor 0 7119.46 C.M.
First Floor (Terrace Floor) 0 7160.01 C.M.
Ground floor 0 9963.33 C.M.
First Floor (Terrace Floor) 2 10003.88 C.M.
4 Providing & fixing IS Mark TMT Bar FE 500d reinforcement for R.C.C.
work incl. bending, binding & placing in position etc.comp.---Ground
Ground floor 8 77.29 Kg.
First floor (Terrace Floor) 99 78.34 Kg.
5 Providing throatingor plasterdrip and moulding it toR.C.C. chajja
etc.comp.. For all Floor (M.R.)
6 Providing 20mm deep finished groove in plaster in lineand level etc.
Comp. For all Floor (M.R.)
DISMANTLING WORKS
7 Demolition of brick work and stone masonry including stacking of
serviceable materials and disposal of unserviceable materials with all lead 1 577.92 C.M.
and lift. (i) On Cement Mortar
8 Removing the scraping of old deteriosted plaster of any thickness form
wall/R.C.C. member including strcking of serviceable material and 57 20.55 S.M.
disposal of unserviceable material from site of work with all lead and lift.
9 Demolition including stacking of serviceable materials and disposal of
unserviceable materials with all lead and lift.' 0 1110.75 C.M.
10 Demolition of terrace including stacking of serviceable materials and
disposal of unserviceable materials with all lead and lift.' 45 66.81 S.M.
1.) Brick tile covering
11 Dismantling C.I. Pipes, G.S.W. Pipes and A.C.,PVC rain water pipes with
fittings and clamps including stacking the materials with all lead & lift ( 50 78.51 R.M.
For any Dia. of pipes )
12 Dismentaling of sheet roofing including ridges, Hips, Valleys, Gutters etc.
stacking of serviceable materials and disposal of unserviceable materials 0 56.79 S.M.
with all lead and lift. (ii) A.C. sheet roofing.
SOR 2024-25 & MR
Description Qty. Unit Amount
13 Dismantling Doors, Windows, Ventilators etc. (wood or steel) shutters
including chowkhats, architreaves, holdfasts, and other attachment etc.
complete and stacking them within all lead and lift.
(1) Not exceeding 3 sq. meters in area .
14 Dismentaling of Tiles floors laid in mortar including stacking of
serviceable material and disposal of unserviceable material with all lead 2 50.11 S.M.
REPAIR & REHABILITATION WORKS
15 Fixing clerestory window chowkhats in existing openings including cutting
masonry for hold fasts, embedding hold fasts in cement concrete blocks
with cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone
aggregate 20 mm single size), painting two coats of coal tar to sides of 1 399.00 NOS.
chowkhats and making good the damge to walls complete including
disposal of rubbish to the dumping ground within
16 Providing and applying cement mortar (1:3) modified by using polymer
and expanding grout additives at various thickness for repair/strengthening
of various RCC elements at all floor levels, lead, lift, including breaking,
chipping, dismentling existing cover concrete and exposing existing
reinforcement, applying wirebrush for making surfaces of steel and
concrete free from rust and other loose materials, applying rust removing
chemical on existing reinforcement, applying anti-corrosive coating on
existing reinforcement, applying polymer bonding agent on existing
concrete surfaces before applying polymer modified mortar in specified
thickness as directed by the Engineer-in-charge.
The rates shall also include providing and applying 12 mm thick cement
mortar (1:4) modified with plasticizer for finishing smooth the repaired
surfaces, providing and applying curing agent on the repaired surfaces, etc.
complete as directed by the Engineer-in-charge. The make and quality of
rust removing chemical, anti-corrossive coating, polymer bonding agent,
polymer and expanding grout additives, plasticizer, curing agent, etc. shall
be approved by engineer-in-charge. The procedure for application shall be
strictly in accordance with manufacturer's detail specification, which shall
be submitted before start of work and shall be approved by the Engineer-in-
The rates shall include the cost of providing, erecting and maintaining
leakproof shuttering /formwork /scaffolding, etc. to be used for the
purpose, providing and erecting props, temporary frame work and maintain
them in position for required time, to existing load bearing elemnts for
reliving loads coming on to structural members being
repaired/strengthened but excludes the cost of reinforcement.
The rates shall include the cost of providing, erecting formwork with
drainage outlet for presocking and air venting. The formwork shall be such
that it provides suitable excess points to pour or pump the mixed micro
fluid concrete in place. The cost shall also include providing and erecting
props, temporary frame work and maintain them in position for required
time, to existing load bearing elements for relieving loads coming on to
structural members being repaired/strengthened but excludes the cost of
chemical use BASF, Sunanda, Fosroc, Pidilite etc as per Approved by
engineer incharge
(Note:- Only Single Payment Consider For Same Work)
0mm To 25mm thickness 3 1208.00 S.M.
0mm To 50mm thickness 3 2348.00 S.M.
17 Providing Formwork of ordinary timber planking so as to give rough finish
including centering, Shuttering, Struting and propping etc. height of
propping and centering below supporting floor to ceiling nott excluding
4m and removal of the same for Cast in situ reinforced concrete and plain
(G)Column, pillers, post and strusts
(i)Square rectangular polygonal in plan (upto 10 ton) 2 320.70 S.M.
SOR 2024-25 & MR
Description Qty. Unit Amount
18 Providing and applying cement mortar 1:4 enriched with expanding grout
additive in required proportion in cement for repair of cracks in RCC and
non-RCC members after making 25mm x 25mm groove, cleaning the
surface and applying coat of bonding, finishing smooth the repaired
surfaces, providing and applying curing agent on the repaired surfaces, etc.
complete at all floor levels as directed by engineer-in-charge. The make and 50 120.00 R.M.
quality of expanding grout additives, bonding agent, curing agent, etc. shall
be approved by the engineer-in-charge. The procedure for application shall
be strictly in accordance with manufacturer's detail specification, which
shall be submitted before start of work and shall be approved by the
Engineer-in-charge.
19 Carrying out Injection grouting for cracks in RCC structural members by
drilling holes of 15 mm diameter upto minimum depth of 75 mm, fixing
aluminium nozzle / rubber pipe using non-shrink epoxy putty, injecting
epoxy grout material at specified pressure with grouting pump till it the
material refuses to impregnate inside the hole. If required or suggested by
the Engineer-in-charge, injection grouting shall be carried out more than
once for a hole to assure proper spreading of grout material and filling of
capillaries / voids within the element. After satisfactory injection grouting,
the nozzle/pipe shall be cut and sealed by non-shrink epoxy putty. The
surface shall be finished smooth with C:M (1:4) and reinstated to the
original condition as directed by the Engineerin-charge.
The rate shall include the cost of providing and supplying all tools,
materials ,labour, scaffolding, props, formwork,etc.complete.The make and
quality of epoxy grout, epoxy putty, etc. shall beapproved by the Engineer-
in-charge.The procedure for application shall be strictly in accordance with
manufacturer's detail specification, which shall besubmitted beforestart of
workand shall beapprovedby theEngineer-in-charge. (Actual noof holes and
their locations shall be as decided by the Engineer-in-charge)
chemical use BASF, Sunanda, Fosroc, Pidilite etc as per Approved by
engineer incharge
20 Carrying out Injection grouting for cracks in RCC structural members by
drilling holes of 15mm diameter up to minimum depth of 75mm, fixing
aluminium nozzle/ rubberpipeusingcementitiouscompound, injecting
polymer modified slurry (SBR+cement+water) 1:1:1material at specified
pressure with grouting pump till it thematerial refuses to impregnate inside
the hole. If required or suggestedby theEngineer-in-charge, injection
grouting shall be carried out more than once for a hole to assure proper
spreading ofgroutmaterial and fillingof capillaries / voids with in
theelement. After satisfactory injection grouting, then ozzle/pipes hall
becut andsealed by non-shrinke poxy putty. The surfaces hall be finished
smooth with C:M(1:4) and reinstated to the original conditionasdirected
by the Engineer-in-charge.
The rate shall include the cost of providing and supplying all tools,
materials, labour,scaffolding, props, formwork,etc.complete.The make and
quality of epoxy grout, epoxy putty, etc. shall be approved by the Engineer-
in charge. The procedure for application shall be strictly in accordance with
manufacturer's detail specification, whichshall besubmittedbeforestart of
workand shall be approved by the Engineer-in-charge. (Actual NOS of
holes and their locations shall be as decided by the Engineer-in-charge)
SOR 2024-25 & MR
Description Qty. Unit Amount
21 Providing and appliying thixotropic Making up lost section of concrete /
mortor with thixotropic repair mortor of one-component, normal-setting,
shrinkage-compensating, thixotropic mortar for layers up to 20 mm thick.
Supply and application of one-component, normal-setting, shrinkage-
compensating thixotropic mortar made from cementitious binders, selected
aggregates, special additives and synthetic polyacrylonitrile fibres, for
reconstructing deteriorated concrete structures. Apply the mortar after
adequate preparation of the substrate by removing all deteriorated concrete
to form a sufficiently-rough, solid substrate with no detached portions.
Clean the steel reinforcement down to bare metal and apply a passivating
treatment by brush-applying two coats of one-component, anti-corrosion
cementitious mortar. Apply the product by trowel or spray with a
continuous-feed rendering machine on a clean substrate saturated with
water in layers up to 20 mm thick.
To improve expansion in the open air during the first few days of curing,
add a special curing additive when mixing the mortar to reduce both plastic
and hydraulic shrinkage at a dose of 0.25% in weight on the weight of the
mortar. The product must comply with the minimum requirements of EN
1504-3 for structural mortars and have the following performance
characteristics:
Compressive strength (EN 12190) (MPa):> 40 (after 28 days), Flexural
strength (EN 196/1) (MPa): 7 (after 28 days), Compressive modulus of
elasticity (EN 13412) (GPa): 25 (after 28 days) Adhesion to substrate (EN
1542) (MPa):> 2 (after 28 days), Capillary absorption (EN 13057)
(kg/m²•h0.5): < 0.20, Thermal compatibility measured as adhesion
according to EN 1542 (MPa): – freeze-thaw cycles with de-icing salts (EN
13687/1): > 1.5 (after 50 cycles), Storm cycles (EN 13687/2):> 1.5 (after
30 cycles), dry thermal cycles (EN 13687/4):> 1.5 (after 30 cycles),
Reaction to fire (EN 13501-1) (Euroclass):1
Consumption (per cm of thickness) (kg/m²): approximately 18.5 Kg
included and calculated in the price for work carried out according to
specification: (1) hydro-cleaning of adhesion surfaces and saturation of
substrate with water immediately before applying the mortar; (2)
application of the mortar by trowel or spray around steel reinforcement; (3)
levelling off surfaces with a straight edge and final tamping; (4) careful
curing of the mortar by spraying on water for at least 7 days (3times) after
(Note:- Only Single Payment Consider For Same Work)
0 MM TO 25 MM THICK 3 1370.00 S.M.
0 MM TO 50 MM THICK 3 2460.00 S.M.
22 Pointing on brickwork with cement mortar 1:1 (1-cement : 1- coarse sand)
(B) Ruled pointing.
MASONARY & PLASTER WORKS
23 Masonary work using Aerated light weight concrete block having crushing
Ground floor 0 4644.08 C.M.
First floor (Terrace Floor) 1 4689.24 C.M.
24 Providing 20mm thick double coat mala cement plaster on brick/concrete
Ground Floor 35 286.10 S.M.
25 Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness
Outside All Floor Plaster 35 417.00 S.M.
26 Apply two coats of putty and two coats of primer of approved brand and
(A) for wall and similar surfaces 138 40.59 S.M.
27 Painting two coats of enamel paint over priming coat (including priming 24 90.00 S.M.
28 Wall painting (two coats) with plastic emulsion paint of approved brand 115 83.36 S.M.
29 Providing and applying two coats of weather shield max paint (3 coat may
SOR 2024-25 & MR
Description Qty. Unit Amount
(A) For wall 187 82.00 S.M.
30 Applying Priming coat over new steel and other metal surface after over 12 36.74 S.M.
31 Applying Priming coat over new wood & wood surface after & incl. 2 43.10 S.M.
32 Providing & laying Vitrified tiles of 8mm thick of Orient, Kajaria, 2 1467.72 S.M.
33 Providing and laying Vitrified tiles 8 to 10 mm thick, 24" x 24" in skrting 0 1135.80 S.M.
34 Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or
L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey
cement slurry mixed with pigment to match the shade of slab including 0 1019.39 S.M.
rubbing and polishing etc. complete. (A) 25mm thick
35 Providing and laying polished kota stone slab 25mm thick in risers of
steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-
Cement : 3 coarse sand) and jointed with gray cement slury mixed with 7 1130.79 S.M.
pigment to match the shade of slab including rubbing and polishing etc.
36 Providing & laying granite slab 18mm thick in Window-Door seal Frame
Etc laid on 10mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) with
nessary adhesive material and finished with flush pointing in white or 1 2026.00 S.M.
colour cement, including rubbing & polishing comp.. (Basic Rate:-
37 Providing & Laying white glazed tiles 6mm. th. of Orient, Kajaria,
Jhonson,Nitco,Somani ,Bellmakeat all floor levels, in flooring, treads of
steps & landings laid on a bed of 12mm. Av.Th.C.M.1:3 (1cement :3sand) 2 900.29 S.M.
finished with flush pointing in white cement etc.com. For all floors
38 Providing & Laying white glazed tiles 6mm. th. Of Orient, Kajaria,
Jhonson,Nitco,Somani,Bell make at all floor levels in skirting risers of
steps & dado on 10 mm. th. C.M.1:3(1cement :3 sand) including necessary 5 932.02 S.M.
cement paste for fixing and joined with white cement slurry etc. complete.
39 Labour charges for edge finishing for granite 21 43.43 R.M.
WATERPROOFING WORKS
40 NOTE :- (1) The whole work is to be executed through specialized agency
with a guarantee of 10 (Ten) years given on a prescribed proforma duly
stamped (2) The rate shall include for work at all floors & conducting
water proof test as directed. (M.R.)
(B) Providing and laying integral cement based water proofing treatment 50 511.00 S.M.
SOR 2024-25 & MR
Description Qty. Unit Amount
41 Providing & Applying Surface Water Proofing treatment on existing
Water proofing.
(1) Cleaning Surface Slab up to Mother slab & free from any Loose
Material. Paint, Dust, Greaze or Remove all existing bituminious Coating
Completely. It is recommended to use intense wise brushing on high speed
Water jet for through Cleaning.
(2) The Substrate must be checked for its Soundness using Small hammer.
All Cracks at corner joint, Channels and Parapet Should be Properly
(3) Cracks/construction joints treatment: Opening the cracks/construction
joints,if any, in V/U shape using electrically operated cutting machine.
Cleaning the surface thoroughly from dust and loose partical using wire
brush and air blower. Filling the cracks if any with polymer modified
cement mortar hybrid PU Sealant depending on the width of crack/joint.
(4) Epoxy primer:The Epoxy primer must be applied on clean and dry
surface by mixing base and hardner in equal proportions with the help of
strirrer and adding equal amount of water and appling on the surface at 80-
100 grams per sqmt and allowed it to dry untill tack free.
(5) Hybrrid polyurea part-A(base) and part-B(hardner) are packed in two
separate containers having the correct predetermined mixing ratio by
weight.Stir individual container separately,Part-A and PArt-B very well, to
get homogeneous material. The whole quantity of Part-B is added into Part-
42 Providing and laying broken China mosaic flooring for terrace using
mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar
1:3 to plain or slope and to be tempered to bring mortar crème out upto
surface using white cement including rounding off junctions and extending
them upto 15 C.M. along the wall, clearing with water and oxalic acid etc.
WATER SUPPLY & SANITARY WORKS
43 Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 110x110
mm diameter with jali of the following nominal diameter of self cleaning
design with C.I. scread down or hinged grating including the cost of
cutting and making
good the walls.
All floor 1 586.27 NOS
44 Providing & Fixing U-PVC pipe (SWR) confirming to IS NOS
(Type "B") of Prince/Supreme/Jain/Astral/Tulsi/FiNOSlex make for soil
and waste discharge system at all floor levels incl. All fixtures like bends,
tees, shoe etc. jointed with resin of approved brand & manufacture etc.
45 Providing & fixing G.I. Rain water spout of 50 mm dia & 30 C.M. length
All floors level 2 101.91 NOS
46 Providing and constructing simple chamber with 23C.M.. th. brick
masonary walls in c.m. 1:5 with cement plaster 15mm. thick in c.m. 1:3
inside and outside to exposed faces,R.C.C. top slab with 1:2:4
mix,foundation concrete 1: 5:10 and fixing C.I. cover with frame to be
NOSt less than 38 Kg.. on top etc. comp. Inside dim. 455 X 610mm X
mm deep for single pipe.
(A) Same as above but Precast RCC heavy duty Cover instead of C.I.
47 Extra for every additional depth of 0.1 mt beyond 0.45 mt. 3 242.39 NOS
SOR 2024-25 & MR
Description Qty. Unit Amount
48 Prov.& Fixing water closet squatting pan (Orissa type W.C.pan) at all floor
levels, size 500mm x 400 mm incl. 100 mm size "P'or "S" trap for water
closet squatting pan joining the trap with the pan & soil pipe in C.M. 1:1 1 3277.39 NOS
(1cement :1 fine sand) etc. Comp.(A) Vitreous china long pattern
Make- Cera S3010109, Jaquar ,HindWare
49 Providing & fixing Wash Hung basin with single hole for pillar tap , Size-
550 x 400 mm at all floor levels, with C.I. or M.S. Brackets painted white
incl. cutting holes & making good the same etc. complete. For all Floor
Make- Cera Cat. No. S2040121, Jaquar SLS- WHT -6801,HindWare10004
50 Providing & Fixing 15 mm Dia bib tap with wall Flange at all floor levels,
polished bright etc. comp.
Make- Cera F2013151 BIB COCK, HindWare F280002 BIB COCK,
Jaquar FLR-5047 N BIB COCK
51 Providing flush cock consisting lever, cartridge sleeve & flange &
Make- Cera EXPOSED PART F2013751 &Concealed part F4060101
Jaquar FLR 5083 KN , CONCEALED BODY ALD-081,HINDWARE
F730013 & CONCEALED STOP COCK F850095
52 Providing & fixing C.P. brass pillar cock with copper connection, C.P.
brass screws complete
Make- Cera F2013101, HindWare Cat. No.: F650003, Jaquar FLR- 5011N
53 Providing & fixing 15mm C.P. brass angle valve (Stop Cock) with C.P.
copper connecting pipe 450 mm long and nuts, washer and brass flange
complete, including cutting and making good the wall where
Make- Cera F1020362, HindWare Cat. No.: F440020 F850094,
jaquar CON 053 KN
54 Providing & Fixing P.V.C. pipes (SCH-80) of Prince/ Supreme/ Jain/
Astral/ Tulsi/FiNOSlex make for water supply line at all floor levels incl.
fixtures like bends, tees, shoe etc joined with resin of approved brand &
manufacture etc. comp. Pipe shall be fixed on the wall the help of clamp at
every two meter C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
55 Providing & Fixing gun metal check or NOSn return full way wheel valve
at all floors levels, etc. complete. (A) 15 mm. dia.
(B) 25 mm. dia. 1 420.63 NOS
(C) 40 mm. dia. 1 663.43 NOS
56 Providing & Fixing abonite ball cock of approved qualities directed etc.
comp. 1 102.91 NOS
(A) 25 mm. dia.
57 Providing & Fixing in position PVC Cowl vent to pipes of
Prince/Supreme/Jain/Astral/Tulsi/Finolex make etc.Comp. (A) 75 mm. dia. 1 40.00 NOS
(B) 110 mm Dia. 1 50.00 NOS
SOR 2024-25 & MR
Description Qty. Unit Amount
58 Providing & Fixing Kathi around the vertical PVC drainage pipes for
concealing with cement plaster 20 mm avg thickness(C.M. 1:3 [1 cement :3
coarse sand]) finishing as per instruction given by Eng. incharge. MR
(A) 75 mm PVC PIPE 3 173.00 R.M.
(B) 100 mm /110 mm PVC PIPE 3 180.00 R.M.
59 Providing & fixing Z - clamps at all floor levels of approved design to C.I.
S.C.I. or PVC pipes including the cost of cutting holes & making good the
wall etc. Complete - 100 mm dia as per architect instructions
(A) 40 to 50 mm dia 6 62.00 NOS
(B) 75 to 90 mm dia 6 75.00 NOS
(C) 110 mm dia to upto 150 mm dia 6 90.00 NOS
60 Removal of Sintex tank with all fittings and refixing at same location but
on the pedastal of 0.3m height from slab level with all necessary fittings
and fastenings as per requirements and as per directions of engineer in
charge. As per M.R. (1000 lit to 10,00 Lit. any size od Tank)
61 Providing erecting and fixing double coated Sintex/Super/Reno PVC (ISI)
mark water tank of required capacity each with all necessary fittings 2000 3.95 Lits
& connection etc. complete on terrace. (sintex tank 10000 lit.)
62 Vegetation Removal from building 1 1500.00 JOB
63 Providing & Fixing M.S.Grills of required pattern to wooden frames of windows
etc. at all floor levels with M.S.flats at required spacing & frame around square or
round bars with round headed bolts & round heade bolts and nuts or by screws 70 109.41 Kg.
incl. Priming coat of Red lead paint etc. comp.
64 Apply hacking on RCC member manual or by mechanical as discoused by
engineer incharge. 350 - 400 notches (dents) per sqmt. Process of making the
back ground rough before plastering for better bonding of mortar with RCC 75 20.00 S.M.
65 Providing & fixing 35mm.th. Flush Door Solid Double Core type Both Face
water proof Ply Vennered & 1.5 mm th.laminate shall be pasted on both side
with adhesives as specified by the manufacturers. The laminate shall be as per
approved shade & texture, of make incl. Sal wood frames of finished size 12cm x 1 3720.00 S.M.
7cm.incl. S.S. Hinges with nessary screws & Anodized aluminum fixtures &
fastenings For all Floor
Same as Above But Without Frame 1 2520.00 S.M.
66 Carrying out wall treatment for termite control including spraying with chemical
solution in oil base including labour and material Using Chlorpyriphos 20 ECAs
per IS 6313 part - II (1% concentration by mass) is recommended i.e one litre
chemical emulsion diluted with 19 liter oil base. Total solution will be 20 36 24.90 S.M
litersinclusive of one liter chemical emulsion application at the rate of 7.5 litre
chemical / Sqm of surface is recommended as per I.Schemical emulsion
recommended as per I.S.
67 Carring out plinth treatment to post construction / existing structure by spraying
chemical solution for termite control treatment including labour and material
consistment with ISI specification. Using Chlordene and Chiorpurfiles 20 EC. As
per 6131_paret-II Consentration Weight one percent is recommended i.e. one 42 87.03 S.M.
litre 20 EC chemical emulsion with 19 liter give 1% concrentration inclusive of
one litre chemical emulsion appication at the rate of 5 litre chemical / Sqm of
surface is recommended as per IS.
68 Providing & Fixing Nylon net (having net weight-0.065 kg/sq.mt) in outside as
well as inside plaster / terrace water proofing etc as direct by E.I.C 70 32.00 S.M.
69 Providing and Replace door, Window S.S. Fixtures fix in wooden / Alluminium
door - window with ISI marks as per approoved by engineer in charge.
(A) 4" S.S. Hinge 15 125.00 Nos.
(B) 5" S.S. Hinge 9 150.00 Nos.
SOR 2024-25 & MR
Description Qty. Unit Amount
(C) 8" S.S. Aldraf 2 180.00 Nos.
(D) 10" S.S. Aldraf 4 210.00 Nos.
(E) 12" S.S. Aldraf 0 240.00 Nos.
(F) 4" S.S. Handle 4mm. Th. 10 150.00 Nos.
(G) 6" S.S. Handle 4mm. Th. 2 180.00 Nos.
(H) 4" S.S. Stopper 4mm. Th. 10 125.00 Nos.
(I) 8" S.S. Stopper 4mm. Th. 4 175.00 Nos.
(J) 6" S.S. Pavan Ankdi Heavy duty 10 100.00 Nos.
70 Providing cement vata (10 cm x 10 cm size) quarter round in cement mortar 1:1
including neat cement finishing, watering etc. complete.
Ground Floor 17 24.28 R.M.
Terrace floor 23 24.28 R.M.
71 "Providing and laying FRP (Fiber Reinforced Plastic) chhajja over doors,
windows and building extensions, factory-moulded with glass-fiber
reinforcement and resin matrix, UV-stabilized, weather-resistant, including MS 0 3136.00 S.M.
brackets, anchor fasteners, anticorrosive painting, sealing of joints, and complete
installation as per specifications and Engineer-in-Charge."
72 Providing & fixing 35mm.th. Indian teak wood shutters for doors, windows &
clear story windows incl. Indian teak wood frames of finished size12cmx
7cm.incl. anodized aluminum fixtures & fastenings incl. Primer coat of approved 2 5533.68 S.M.
quality & two coats of oil painting etc. For all Floor (A) Fully Panelled
73 Aluminum section Window opening and refixing with all necessary fix & fiting
etc maid in wisely
74 Providing – supplying & fixing top & bottom aluminum frame (50 x 25)
mm thick & central lock frame with ( 75 x 25 ) 1.03 mm thick color anodized
with 4 mm thick ACP (Exterior grade plain colors) with aluminum anodized 1 2580.00 S.M.
aldrop, stopper & fixing with S.S screws etc all per directed by engineer in
75 Providing & fixing G.i mesh 25X25X3mm used for celling repair fixed with
celling rebar column as per directed by enginner incharge rate excluding the 5 546.00 S.M.
76 RCC Core Cutting is about making precise, circular cuts for creating holes of
required diameters for Rehabilitation in civil works. The core drilling rod is fitted
with diamond pieces at the drilling end. The core cutting machine can be used
for both horizontal and vertical hole making purposes.
77 Polishing flooring after repair work done as direct by E.I.C 0 172.00 S.M.
78 Providing and Fixing Hollow steel Sections Framed Work including Cutting,
Hoisting,Welding & Fixing in position Purlin, Main Chord etc.as per Engineer in- 50 126.00 Kg.
charge.TATA / JINDAL / ASIAN Make
79 Providing and fixing rebar of following diameter using chemical grout of
Swanchore/Hilti/Fischer or equivalent make including cost of all equipments,
tools, material, labour, etc. Standard procedure as mentioned in manufacturer's
specifications shall be strictly followed, which shall be submitted and got
approved from the authority prior to start of work. The rate shall also include cost
of drilling of hole of required diameter and depth as mentioned in manufacturer's
specification, cleaning the hole with required airblower and other necessary tools
and tackles, positioning, providing and grouting chemical, allied fixtures and
fasteners, etc. but excluding the cost of reinforcing bar etc. complete. Item
includes necessary scaffolding, staging, labour, tools and equipments, etc.
complete as directed by the engineer-incharge.
SOR 2024-25 & MR
Description Qty. Unit Amount
80 Decorative wall paintings with designing, painting at place with all necessary
material surface preparation , primer application 2 coats of weather coat paint 300 40.00 Sq.ft.
artwork creation including labour
81 Slogan writing on walls designing, painting at place with all necessary matirials
surface preparation, primer application 2 coats of whether coat paint, artwork 100 30.00 Sq.ft.
creation including labour
82 Vinyl Sticker any size 1. Eco Solvent vinyl
sticker (120 gsm) with laminate (100 gsm)
83 Vinyl Sticker any size 2. Solvent vinyl sticker
(120 gsm) with laminate (100 gsm)
84 5 mm PVC sheet Eco vinyl any size 25 52.00 Sq.ft.
PART B :- GROUND DEVELOPMENT + COMPOUND
GROUND DEVELOPMENT WORKS
1 Removing Paver block flooring 70 10.10 S.M.
2 Excavation for foundation includ.sorting out & stacking of useful materials &
disposing of the excavated stuff upto 50 mt. Lead & all lift, watering etc. Comp.
(A) Loose or Soft soil-With Manual Labour
(1) Up to 1.5 Mt. depth 11 212.52 C.M.
3 Providing & laying cement concrete Pavement using M30 concerte & Vaccuum
Dewatering technique including floating surface with a skim powder floater, 11 6548.83 C.M.
curing etc. complete.
4 Providing & fixing IS Mark TMT Bar FE 500 / FE 500D reinforcement for
R.C.C. work incl. bending, binding & placing in position etc. comp. Upto
5 Providing & filling in plinth with yellow soil or selected soil in layers of 20 cm.
Th'. Incl. watering, ramming & consolidation etc. complete.
6 Preparation of subgrade with Compacting, Levelling and consolidation of
subgrade with miniroller/plate vibrator machine including watering and filling in
depressions which occur during the process as directed by engineer-in-charge. 70 9.00 S.M.
7 Providing & laying Granular sub base (GSB) confirming to Grading-II of Table
400.0 of compacted thick of 150mm with specified graded stone metal and sand
mixed in place and laid with mechanical means spreading with motor grader and
compacting with vibratory roller having minimum 80-100 KN static weight to 8 1469.00 C.M.
acheve desired density of 98% of MDD including all material, labour, machinery
with all leads and lift etc. complete.
8 Providing and laying 200 micron plastic sheet on prepared sub base For V.D.S
9 Providing & laying C.C 1:3:6 (1cement :3 coarse sand :6 Crushed stone agg
20m.m Nominal size)&curing comp. excl. cost of form work in :(a) foundation & 6 3095.25 C.M.
10 Supplying & filling fine sand (pana) in 150 mm compacted thickness over the
base including necessary compaction, watering etc. complete. Item includes
leveling by using vibratory plates compacted machine and as directed by 0 1016.00 C.M.
engineer in charge.
SOR 2024-25 & MR
Description Qty. Unit Amount
11 Providing & fixing interlocking type Cement Concrete paver block of approved
shape & design having 80 mm thickness (M-50) purchased from SMC's
approved paverblock manufacturer only on fine sand bedding. Item includes
leveling by using vibratory plates compacted machine. Item also includes all
materials, Labour, euipments, tools, plants, watering, cleaning etc. complete.
12 Cutting of Groov 5.00 mm wide in VDS for depth of 250.00 mm of total
thickness making bays of 4.0 mtr x 4.0 mtr. Using groove cutting machine with
diamond cutting wheel and filling of sealent etc. complete as per directed by 200 50.00 R.M.
Engineer in-charge
13 Providing 100mm thick readymade C.C. kerb of strength M-20 (size 300mm x
380mm) purchased from SMC's approved paverblock manufacturer &setting in
line, level and in truly vertical position, including filling joints in C.M. 1:1 (1 part
of cement : 1 part of stone dust) smooth pointing in C.M. 1:1 (1 part of cement : 40 228.00 R.M.
1 part of coarse sand) including watering etc. complete and as directed by
engineer in charge.
For rounding at the edge of footpath (For fanning portion) 10 274.00 R.M.
COMPOUND WALL REHEBLITATION
14 Demolishing Brick work and stone masonry incl. including stacking of
serviceable material and disposal of unserviceable material with all lead and lift. 1 577.92 C.M.
(ii) In cement mortar
15 Removing the scraping of old deteriosted plaster of any thickness form
wall/R.C.C. member including strcking of serviceable material and disposal of
unserviceable material from site of work with all lead and lift. Including 18 20.55 S.M.
16 Masonary work using Aerated light weight concrete block having crushing
strength not less than 35 kg/sqcm for super structure above plinth level upto floor
two level in cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as per 1 4644.08 C.M.
Technical Specification
17 Providing & Applying 20mm.to 35mm Th.(Max. 35mm thickness consider)
Heavy Roller plaster on walls or similar surfaces at all floor levels consisting of
12 mm av. Th. Backing coat of C.M. 1:3 (1 cement:3 sand : racron 3s ( 0.5 nos
per bag )) also plaster master wterproofing chemical 100ml /bags as per
companey manual & approved by E.I.C or consultant & 8 mm. th. Finishing coat 102 417.00 S.M.
of C.M. 1:1 (1 cement: 1 sand) apply thick cement slurry and apply roller
horizontal as well as vartical ( two times ) up to good quality and size of grain in
elevation as per directed by engineer incharge.
18 Providing and applying two coats of weather shield max paint (3 coat may be
required in case of darker colours.) of ICI DULEX or Apex ultima of asian paint
including applying exterior acrylic primer coat as per manufacturers specification
and dirctions in shade and colour approved by architects, on exterior surface of
the building including scaffolding, preparing the surface, watering, curing etc.
complete and as directed by the architects and manufacturers.
Surface Preparation :Surface is throughly clean, dry and free from all loose dirt,
chalk, grease, fungi, algae and flaking paint. This can be achieved by brushing
with a wire / stiff coir brush followed by water jetting if required. Fill up all 205 82.00 S.M.
minor cracks and defects with white cement and sand mixture in the ratio 1:3.
For application on previously painted wall, previous coatings of paint must be
throughly scraped off and Clean the surface throughly using wire brushes.
PRIMING:Apply a liberal coat of exterior acrylic primer and allow it to dry for 4-
5 hours. Application of putty is Not recommended. Minimum 4-6 hours duration
is required between each coat of weather shield max paint.
19 Providing and fixing and fitting TATA or Jindal make G.I. barbed wire fencing
with necessary barbed wire (12 x 14 guage, weight not less than 0.14 kg. / mt.)
pins, hooks, excluding M.S. angles etc. complete as per relevent IS 15 125.00 K.g.
specification.& directed by engineer in charge
20 Steel work welded in built up sections, framed work including cutting, hoisting,
fixing in position and applying a priming coat of red lead paint
SOR 2024-25 & MR
Description Qty. Unit Amount
(A) in beams & joists channels angles, tees, flats with connection plates or angle
cleats as in main & cross beams,hip & trussed purlins connected to common 2 9108.48 Qtl.
raffers & the like.
21 Applying Priming coat over new steel and other metal surface after over and
including preparing the surface by throughly cleaning oil, grease dirt and other
foreign matter and scoured with brushed fine steel wool, scrapers and sand paper 5 36.74 S.M.
with ready mixed priming paint brushing red lead.
22 Painting two coat (excluding priming coat) on new steel and other metal surface
with synthetic enemal paint, burshing to give an even shade including cleaning 5 68.57 S.M.
the surface of all dirt, dust and other foreign matters.
PART C :- ELECTRICAL WORKS
Part-01 Point wiring in Copper (MODULAR)
1 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand
copper wires up to 10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth continuity of following
type, erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
2 Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of ISI marked 1.1 KV grade ZHFR PVC insulated multi
strand copper wires, in below type of pipe to be erected complete with earth
continuity and necessary connection with primary light with accessories erected
on Metal / PVC / wooden box covered with 3 mm thick PC(Polycarbonate) /
Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling
rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
3 Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both
are of .ISI marked 1.1 KV Grade ZHFR PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected with 6A Modular type switch
and hum free EME step type electronic fan regulator mounted and accessories
with earth continuity of following type erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured/metallic/white front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling
rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
Cat. III 0 670.24 Pt.
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Cat. III 3 708.41 Pt.
4 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade ZHFR PVC insulated multi strand copper wires
up to 10 mtr length, in below type of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby
switchboard/mcb db board
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
SOR 2024-25 & MR
Description Qty. Unit Amount
Cat. III 2 535.55 Pt.
5 Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are
of ISI marked 1.1 KV grade ZHFR PVC insulated multistrand copper wires, in
following type of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box
covered with appropriate front plate modules erected on / in wall / ceiling as per
pipe erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete
(f) with medium class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete
Cat. III 2 782.65 Pt.
6 Point wiring for on board Looped Plug with 6A Modular type switch & 5 pin
socket erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate modules erected on / in wall / 6 270.43 Pt.
ceiling with following type accessories
7 Conduits & Pipes
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall or ceiling erected with necessary PVC
fittings & Junction boxes fixed with adhesive solution & Clamps with following 20 24.24 Mtr.
dia of pipes, in approved manner as directed
8 Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts etc. complete of following sizes. (1) 20 mm 20 17.17 Mtr.
9 Supplying & erecting UPVC Mini trunking (PVC Casing-n-Capping) having
double-locking arrangement with grooves, trunking of size not below 12.5 mm in
height as per IS with accessories of PVC/Resin polypropylene not below 1.8 mm 5 31.31 Mtr.
thick duly sealed in joint & erected on wall / ceiling of following size .(2) 25 mm
10 Mains & Wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm 50 62.62 Mtr.
(b) 2 wire 2.5 sq. mm 50 82.82 Mtr.
(C) With oval conduit /PVC casing capping double lock type
(a) 2 wire 1.5 sq. mm 20 56.56 Mtr.
(b) 2 wire 2.5 sq. mm (From LDB to SB and SB to SB ) 30 82.82 Mtr.
11 Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper
conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour
for earth continuity of following size (C) with oval conduit /PVC casing capping
double lock type
(a) 2 wire 4 sqmm 10 112.11 Mtr.
(g) 4 wire 4 sq. mm 5 180.79 Mtr.
(b) 2 wire 6 sq. mm 5 147.46 Mtr.
12 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV
grade to be erected as directed of following size.
(E) 3 core 2.5 Sq. mm 50 137.36 Mtr.
Part-02 LT Switchgear, Distribution Boards & LT Panel
SOR 2024-25 & MR
Description Qty. Unit Amount
13 Providing and erecting Sheet Steel powder coated MCB distribution board - flush
/ surface mounted fitted with busbar, neutral link, earth bar and DIN rail,
Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of MCB to
be used) suitable for
(A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43)
(ii)6 way 2 885.77 Ea.
(iii)8 way 0 1152.41 Ea.
14 providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz. having characteristic of quick
action & tripping with all advance feature & do not incorporate any electronic 1 1969.50 Ea.
component. for following Max. rating erected as directed (i) 25 Amps.DP Cat.
15 providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to
operate on 240 V A.C. system and having breaking capacity 10 KA to be erected
in existing box. confirming to IS 8828/1996 with ISI Mark 6 112.11 Ea.
16 Providing & erecting 240 V MCB double pole switch for motor & inductive load
(C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing
box having following capacity
(A) 6 to 32 Amp.
Cat III 2 299.97 Ea.
17 sheets Steel powder coated enclosure suitable for incorporating One/Two nos.
18 Providing and erecting metallic vitrified danger notice board as per language
suggested by engineer incharge for MEDIUM VOLTAGE installation to be 2 69.69 Ea.
erected as per IS-2551.
19 Solder less crimping type Copper lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to switchgear
terminals with brass/cadmium plated nut bolts in an approved manner. 10 8.08 Ea.
Part-03 Indoor Lighting Item
20 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
Watt assembled on single MCPCB, with housing used as a heat sink shall be
made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED driver
efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.)
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet 10 373.70 Ea.
21 Supplying and erecting led lamps with following wattage capacity of 220 to
(A) LED Lamps integral type, with PC diffuser suitable LAMP holder
(ii) 5 to 8 watts 2 112.11 Ea.
SOR 2024-25 & MR
Description Qty. Unit Amount
22 Supplying and erecting LED street light / Flood light fittings with High power
White LEDs wattage of 3 Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass
with company mark/name engraved or embossed 160 to 270 V,Power Factor
more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection.
(i) above 36 to 48 watts
Cat-lll 2 3345.12 Ea.
Part-04 Fan & Accessories
23 Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium blades with , canopy & 30 cm. 3 1948.29 Ea.
down rod erected with earthing. (Make shall be approved by Engineer in charge)
24 Supply, Installation, Testing and Commissioning of suitable sweep, BEE 5 Star
rated, Ceiling fan with Brush Less Direct Current (BLDC) permanent ferrite
magnet Motor, class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos.
canopies, shackle kit with earthing provision, copper winding, Power factor not
< 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum
CMM, 350 RPM,230v (tolerance as per IS : 374-2019), THD < 10%, with
remote unit for Speed Control and all remaining accessories including safety pin, 2 2885.57 Ea.
nut bolts, washers, temperature rise = 75 degree C (Max.), suitable for 140 to
285 Voltage and rectifier circuit with surge, over current and overload protection
, 50 Hz, Single phase AC Supply, earthing etc. Complete as required.[ Make shall
be approved by Engineer in Charge] (B) 1200 mm Sweep (48")
25 Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe
down rod erected duly painted for fan complete with proper insulation without 3 108.07 Mtr.
leckage and earthing.
26 Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the 3 108.07 Ea.
27 Supplying & erecting single phase approved make industrial exhaust fan suitable
for medium duty ring mounted low noise operation suitable for medium duty
having following dia size and maximum speed in RPM
[A] 305 mm dia 900 RPM Cat.II 1 2054.34 Ea.
28 Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
Part-05 Earthing System
29 Providing and erecting required size HOT deep Galvanised iron strip for earthing
of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper 5 77.77 Kg.
SOR 2024-25 & MR
Description Qty. Unit Amount
30 Supplying & erecting in earthpit of minimum bore dia. 225mm size approved
make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-
1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of
mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising, connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high charge dissipation
suitable for following type of applications with chamber and heavy duty cover
(A)(approved make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and officer Incharge
has to ensure the value of earthing resistane mentioned in test Certificate) &
having back filling compound of (B) Inner chemical (CCM Compound)-
Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- <
volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :-
Earthing compound should be capable to retain moisture for long time Necessary
test report must be submitted by Agency.
[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr 1 5842.85 Ea.
Back filling compound - 1 Nos. of Bag of 15 Kgs.
31 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 1 794.87 Kg.
32 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
33 Providing and erecting Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade
G.I. pipe with necessary coupling buch buried in specially prepared earth pit &
G.I. earth wire of 8 SWG erected & connected as directed (For panel) 2 823.15 Ea.
34 For using salt and charcoal / coke as required for pipe type earthing. 2 171.70 Ea.
35 Supplying & erecting funnel type earthing having earth plate of following size
burred in specifically prepared earth pit 3 mtr. below ground with 40 kg.
charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe
with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover
complete as per para 7.3 of IS 3043 with necessary length of double Galvanised
Iron / copper earth wire No 6 SWG bolted with lug to the plate and covered in
mm dia. G.I. pipe 2.5 mtr long complete connected to the nearest switch gear
with end socket as per direction & duly tested by earth tester confirming to IS
(As per drawing) with following specification
(A) With 30 x 30 x 0.35 cms: C.I. earth plate 1 2311.89 Ea.
36 ABC TYPE FIRE EXTINGUISHER :-
6KG CAPACITY 1 1896.02 NOS
(MAKE:- SAFEX / KANEX / V-SAFE)
37 CO2 TYPE FIRE EXTINGUISHER :-
4.5KG CAPACITY 1 4740.06 NOS
(MAKE:- SAFEX / KANEX / V-SAFE)
G.I. "C" CLASS PIPE AS PER IS 1239 WITH PAINTING
(1 COAT OF ZINC OXIDE PRIMER AND 2 COATS OF PO RED PAINT),
SUITABLE TYPES OF SUPPORTS, HILTI FASTENERS, BOLTS, NUTS
(GALVANISED), CLAMPS, "U" BOLTS, FITTINGS SUCH AS REDUCERS,
TEES, ELBOWS, FLANGES. INCLUDING CUTTING, WELDING, FIXING
IN/ON WALLS, (MAKE:- ASIAN / JINDAL)
50MM DIA 20 929.11 MTRS
Part-07 Motor, Pumps & Starter
39 Providing & erecting open well type horizontal mono block pump set with
stainless steel body having following specification
SOR 2024-25 & MR
Description Qty. Unit Amount
(C) 1 H.P. single phase open well motor pump set suitable for 185 LPM
discharge @ 25 mtr. head, suitable for 32 mm dia. Delivery pipe with control 0 9613.18 Ea.
40 Providing & erecting open well horizontal mono block pump set with cast iron
body, complete for three phase submersible motor having
[A] For 1.5 HP 3 phase open well horizontal mono block pump set suitable for
190 LPM @ 20 mtr head suitable for 40 mm dia delivery pipe
41 Supplying and erecting Direct On-line Electronics Starter with 2-5/4-10/8-14/10-
16 Amp. Rating relay (variable current setting) directly operated in totally
insulated elegant enclosure and 18 Amp. Rating power relay with start - stop
button for single phase operation up to 3 HP as per complete erected on P.W.
Block with following features. 1 1603.88 Ea.
Low voltage cut off below 140 V
High voltage cut off above 280 V
Overload protection
Indicating LEDs for motor on lv, hv & overload tripping. [Cat.II]
42 Supplying & erecting approved make Automatic liquid level controller 6A.as per
instruction of Engineer in charge on site complete with wiring connection with
existing wires , with copper conductor from pump to upper and lower tank. 1 2355.32 Ea.
43 Supplying & erecting approved make self-priming domestic monoblock water
pump with 1 H.P motor, suitable for operation on 230 volts, 50c/s. AC supply
with metallic flange, and M.S. impeller delivery and following discharge
(a) 40 LPM at 24 mtrs. head suitable for 25mm dia. Delivery Cat.III 1 7679.03 Ea.
44 S.I.T.C. of single phase submersible pump set suitable for 100 mm size or more
dia bore well having motor capacity and discharge as under with necessary panel
box. Lifting and Lowering taken extra.
(a) Motor rating 1 HP (12 stage) pump having capacity of 50 LPM at 43 to
mtr head suitable for 32 mm dia. delivery pipe
Cat.II 0 15595.41 Ea.
45 Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible
Submersible copper cable approved make of following Size.
(A) 3 Core x 1.5 Sq. mm. 50 65.65 Mtr
Part-08 Water Cooler & Purifier
46 Providing and erecting water cooler having storage capacity 80Ltr. & cooling
capacity 40 Ltr.per hour @ an ambient temp of 450 C. The outlet temp. of the
water should drop by 150 C within a hour, The water cooler should be
comprising of hermetically sealed compressor, fan motor, condensing unit, water 1 49559.69 Ea.
tank surrounded by evaporating coil, thermostats, relay etc. complete with
necessary inlet & outlet connection. The body of water cooler will be made from
Stainless Steel.
SITC of Water Purifire Eureka Forbs Make AG 200 or Equivalent 1 10605.00 Ea.
47 Supplying and erecting water filter cum purifier with ultra violate technology.
(Aquaguard / waterdoc model or equivalent symphony/ crystal/videocon model) 1 5424.71 Ea.
Part-09 Other Work
48 Supplying & erecting approved make SMC press moulded composite FRP.
loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip
5way(3P+N+E),DIN rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth bolt of following size of
(B) 250mm x 200mm x 100mm [deep] 2 515.10 Ea.
SOR 2024-25 & MR
Description Qty. Unit Amount
49 Providing and erecting street light pole bracket comprising main B Class MS
pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size
pole top having sufficient fasteners for fixing the brackets and having spread of
mtr. length with suitable rise as per site condition & suitable welded stiffener
reducer and nipple with check nut complete painted with one coat of Red oxide /
PU base primer and two coats of Aluminium / PU paint. paint with following nos
[A] Single Arm bracket 1 Mtr 2 561.56 Ea.
50 Supplying and erecting HYLAM sheet on existing angle iron frame.for following
1 771.64 sq.mtr
TOTAL (B) ANGANWADI AT LAL TAMBU,KOSAD VILLAGE
TOTAL BHARTHANA-3 ANGANWADI ,BHARTHANA VILLAGE (PART-A)
TOTAL LAL TAMBU ANGANWADI, KOSAD VILLAGE (PART-B)
EXECUTIVE ENGINEER
NEW EAST (SARTHANA) ZONE
SIGNATURE OF CONTRACTOR SURAT MUNICIPAL CORPORATION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tech Bid Anganwadi Renovation WO NO 02.pdf
SCH B Anganwadi Renovation WO NO.2.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .