Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | L1 | Accepted-AOC Admitted Found Reasonable for Acceptance | |
| 2 | L2₹25.7 L+₹8,533 (0.33%)Rejected-AOC | L2 | Rejected-AOC Rejected L1 being accepted | |
| 3 | L3₹27.8 L+₹2.2 L (8.65%)Rejected-AOC | L3 | Rejected-AOC Rejected L1 being accepted | |
| 4 | Rejected-Technical 107J 79 50F PALAI ROAD WEST OPP TO MILLERPURAM WATER TANK TUTICORIN THOOTHUKUDI TAMIL NADU 628008 | TUTICORIN | TAMIL NADU | 628008 | - | Rejected-Technical Non Submission of EMD |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Oct 2021, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-06
As per tender documents
2021_MES_475644_1
GE (ARMY) TVM 9408/E8
Open Tender
Industrial/Medical GAS
Item Rate
90 days
Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹60,000
Yes
16 Nov 2021
16 Sept 2021
16 Oct 2021
16 Sept 2021
14 Oct 2021
30 Sept 2021
17 Sept 2021 - 29 Sept 2021
Amount
Supply, fixing, testing and commissioning of semi automatic control panel with alarm for oxygen having a minimum flow rate of 1500 lpm as per tested HTM 2022 and having two first stage regulators each capable of delivering 100 - 200 psi g oultet pressure. The first stage regulators should be connected to a common second stage regulator which will deliver an outlet pressure of 60 psi g. 40 micron filer should be provided at the inlet of each high pressure regulators of the oxygen control panel. Note- Item should be ISO certified and approved by Garrison Engineer .Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of 6+6 Size Oxygen Manifold configured with 2x6 nos. of class J (bulk D type) cylinders capable of withstanding working pressure of 145 kg/cm2 along with tail pipes and NRVs - 12 nos of high pressure copper annealed tail pipes with end brass adapter suitable for Oxygen Gas. Brass NRV blocks 12 nos. Note- Item should be ISO certified and approved by Garrison Engineer. Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of emergency point. 1 Size Oxygen Manifold configured with 1 no. of class J (bulk D type) cylinder capable of withstanding working pressure of 145 kg/cm2 along with tail pipe and NRV - 1 no of high pressure copper annealed tail pipe with end brass adapter suitable for Oxygen Gas. Brass NRV block 1 no. Note- Item should be ISO certified and approved by Garrison Engineer Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of copper pipe and providing adequate supports while laying pipe lines to ensure that the pipe do not sag (medical grade as per BS 2871 ) of size 15 mm OD X0.9 mm. Make-MEXFLOW
Supply, fixing, testing and commissioning of copper pipe and providing adequate supports while laying pipe lines to ensure that the pipe do not sag (medical grade as per BS 2871 ) of size 22 mm OD X0.9 mm. Make-MEXFLOW
Supply, fixing, testing and commissioning of copper pipe having adequate supports while laying pipe lines to ensure that the pipe do not sag (medical grade as per BS 2871 ) of size 12 mm OD X0.9 mm. Make-MEXFLOW
Supply, fixing, testing and commissioning of surface mounted British standard / din gas outlet for front loaded colour coded ( O2-12 Nos,Air-09 Nos,Vac-12 Nos). Note-Item should be ISO certified and approved by Garrison Engineer.Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of suitable probes for outlets. Matching probes for gas terminal units - oxygen, air and vacuum. The probe should comply with BS 5682 : 1998 for gases and vacuum. Matching probes with one end suitable for hose/flow meter and other end suitable for Imported ans Indigenous Medical Gas terminal units which complies and fully meets with the latest standard HTM02-01 and C11. Note- -Item should be ISO certified and approved by Garrison Engineer.Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of BPC flow meters with humidifier bottle made of unbreakable (polycarbonate material and autoclavable at 121 degree centigrade) having control within a range of 0 - 15 lpm (Calibration within ± 10%). The flow meter body should be made of brass chrome plated materials. Note- -Item should be ISO certified and approved by Garrison Engineer .Make-GHL/HMP/MEDFLOW/S KUMAR/G FLOW
Supply, fixing, testing and commissioning of ward vaccum unit of light weight and compact with regulator collection jar of 600 ml made of unbreakable polycarbonate material and autoclavable at 134 degree centigrade with wall brackets for mounting the jar assembly on the wall (Indigenous).Note- -Item should be ISO certified and approved by Garrison Engineer.Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of Isolation valve 15 mm having 90 degree turn,ball type& non lubricated for gas complete all as specified and directed.Note- -Item should be approved by Garrison Engineer . Make-Metrix/I&B
Supply, fixing, testing and commissioning of Area Alarms ( for four gases viz oxygen,air, vaccum, nitrous oxide)units with audio and visual alarms while pressure is lower than recommened Note- -Item should be ISO certified and approved by Garrison Engineer.Make-GHL/HMP/MEDFLOW/S KUMAR/ G FLOW
Supply, fixing, testing and commissioning of vacuum system 3 HP Belt driven type with motors and fittings Make: IR/Aerotek/ANESTAIWATA .Technical specification-Motor :Belt driven 3 Phase , Make:Crompton/Kirloskar, Motor power:3HP,RPM:500,Reservoir:500 Ltr for 3 Nos motor .In built automatic control panel with auto cut switch complete all as specified and directed.Bedding for the vacuum pump is provided with length 100 cm, width 60 cm and height 15 cm. Note- -Item should be ISO certified and approved by Garrison Engineer
Supply, fixing, testing and commissioning of Air Compressor system 3 HP Belt driven type oil free Air compressor with motors and fittings Make: Anesta Iwata/Aerotek/NEC.Technical specification-Motor :Belt driven 3 Phase,Make:Crompton/Kirloskar,Motor power : 3HP , RPM : 1440 , Reservoir :280 Ltrs for 3 nos motor ,Working pressure 8.5 kg/cm2 .In built automatic control panel with auto cut switch complete all as specified and directed. Bedding for the air unit is provided with length 100cm, width 60 cm and height 15 cm above GL and 15 cm below GL of PCC block masonary of 1:3:6 and external surface plastered in CM 1:4. Note- -Item should be ISO certified and approved by Garrison Engineer
Supply, Install, testing and commissioning Medical Gas cylinder for Oxygen capacity 7000 ltrs ,water capacity 46.7 ltrs, working pressure (minimum) 150 Kg/cm2 at 15 degree C,Test pressure (minimum) 250kg/cm2 at 15 degree C ,Shell thickness (minimum) 5.5 mm ,gas specify-Oxygen,standard IS 7825 complete all as specified and directed at site.Note- -Item should be ISO certified and approved by Garrison Engineer
Cutting Chasing ,making holes on wall and make good the damaged wall surface as per existing surface all as directed by Engr in Charge.
Supply and laying LT XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with standard aluminium conductor 25 sq mm 4 Core all as specified and directed by Engineer-in-Charge Make : Finolex, Havells, abster,RPG, Universal, NICCO, CCI.
Excavation in trenches n.exc 1.5mtr wide and n.exc 1.5mtr in depth and getting out in hard/dense soil for cable/pipe/poles, trimming the sides forming bottom surface to required levels complete all as specified and directed.
M&L for Returning filling in & including spreading leveling watering and well ramming in layers not exc 25cm all as specified and directed.
M&L for Removing excavated materials (surplus soil) to a distance not exceeding 50m in distance and depositing where directed at level n exc 1.5 m above the starting point all as specified and directed.
M & L brick common burnt clay sub class 'B'; lying flat on cable in trenches size of brick 230 x 115 x 75 mm all as specified and directed.
Supply and fix MCB DB TPN 4 way double door 415 volts, with minimum capacity of 200 Amps rated copper busbar including necessary dummy plate all as specified and directed. Make : L&T, Indo Asian, Havells, ABB, Standard, Siemens, HPL, MDS Legrand
Supply and fix MCB triple neutral (MCB TPN), 415 volts, of capacity 32 Amps all as specified and directed.Make : L&T, Indo Asian, Havells, ABB, Standard, Siemens, HPL, MDS Legrand
Supply and fix MCCB TPN 100 Amps 415 volts AC 50 Hz 16 KA all as specified and directed.Make : L&T, Indo Asian, Havells, ABB, Standard, Siemens, HPL, MDS Legrand
Material and labour for Submain wiring with 4 runs of 10 sqmm single core, multistranded PVC insulated unsheated cable 1100 volts grade with copper conductor, drawn in and including concealed rigid PVC conduit, conduit fittings and accessories concealed in wall/roof/floors with one run of 10 sqmm PVC insulated unsheathed multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly all as specified. Make : Finolex, Plaza, Nicco, RPG, Anchor , Havells, Standard, Indo Asian
M & L for earthing galvanised steel earth plate electrode 600 x 600 x 6.30 mm thick burried directly in ground (earth plate not less than 2.25 mtr deep below normal ground level with top edge of the plate less than 1.5 mtr below normal ground level) connected to GI strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including GI pipe light grade 40 mm bore for protection of earth lead, GI funnel and wire mesh etc complete all as shown in Electrical plate no 3 of SSR 2009 (part-I) including necessary excavation earth work, form work, earth pit of size 450 x 450 x 300 mm of PCC M-15 (Nominal mix) using stone aggregate earth pit cover of PCC and 20 mm bore light grade GI pipe for watering and charcoal dust, common salt, and connected to test point 7.5 mtr from earth pit including testing complete all as specified and as directed.
Supply and laying GI pipe light grade with all fittings complete fixed to walls/poles laid in trenches for cable protection 50 mm diameter complete all as specified and as directed. Make: Jindal, Tata , Surya, Prakash, Swastik
Supply , install, testing and commissioning of heatless type drier including 1 after cooler with moisture separator, 1 bacterial filter- 4 stage - 1 No,pressure regulating system with valves- 4 bar. All other auxiliary equipment accessories, piping, plumbing etc required for completing the system will be included. Make : Trident, Dryspell, Reliable
M/s Kamal Builders
Thejus Surgicals and Medical Equipments
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .