Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.7 CrAccepted-AOC | ₹12.7 Cr | 1 | Accepted-AOC Accepted since L1 bidder |
| 2 | 2₹13.5 CrRejected-Finance | ₹13.5 Cr | 2 | Rejected-Finance Rejected Since not Since L1 |
| 3 | 3₹13.8 CrRejected-Finance | ₹13.8 Cr | 3 | Rejected-Finance Rejected Since not Since L1 |
| 4 | 4₹13.9 CrRejected-Finance | ₹13.9 Cr | 4 | Rejected-Finance Rejected Since not Since L1 |
| 5 | 5₹14.1 CrRejected-Finance | ₹14.1 Cr | 5 | Rejected-Finance Rejected Since not Since L1 |
Tender Value
₹14.9 Cr
EMD Value
₹10.7 L
Closing Date
10 Jul 2020, 6:00 pmClosed
DDG CE
DDG CE DGNP NAVAL BASE POST PIPE LINE JN VISAKHAPATNAM 530014
AUGMENTATION OF STEAM SUPPORT SERVICES FOR ARIHANT CLASS SUBMARINES AT ND V VISAKHAPATNAM
2020_MES_350273_1
CA No DDG CE V TOKEN 06 OF 2019 2020
Open Tender
Civil Works
540 days
VISAKHAPATNAM
As per NIT
7 documents required · 7 mandatory
₹3,000
Yes
DGNP
₹10.7 L
Yes
DDG CE CONFERENCE HALL
19 Oct 2020
5 Jun 2020
13 Jul 2020
5 Jun 2020
10 Jul 2020
3 Jul 2020
5 Jun 2020 - 16 Jun 2020
19 Jun 2020
Amount
SCHEDULE "A" PART - I [CIVIL WORKS]
Dismantling steel sheeting, plain /corrugated or semi corrugated of any gauge, thickness sheets as in roof/wall coverings including ridges etc., complete all as specified and as directed.
Dismantling timber scantling framed work 40sq.cm and over section, in any position complete all as specified and as directed.
Dismantling of boarding any description, fixed in any position with screws, complete all as specified and as directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and as directed.
Dismantling of Textile coverings including frames (if any) and cover fillets (measured flat and not girthed), complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling framed trusses not exceeding 20.0m span, of any description and any location, complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in cement concrete and making good disturbed ground, complete all as specified and as directed.
Taking down chowkats or frames n.exc 1.5Sq.m. with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 Sq.m. but n.exc 4.0Sq.m. with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Demolition of cement concrete [unreinforced] in ground floors and paving's n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Demolition of cement concrete [unreinforced] of any description in any position, not otherwise separately provided for, complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Taking up or down steel tubing 15/20mm bore of pipe of any grade and connections for material taken back by contractor through credit, complete all as specified and as directed.
Removing demolished building materials/ debris etc (other than soil obtained from earth work) to a distance n.exc 5.0km, including loading and unloading and depositing outside the MD land at GVMC designated places, complete all as specified and as directed. Note: 1. Materials considered under Schedule of Credit shall not be considered in this item. 2. Definition of load shall be as given in section 21 of SSR Part-II.
Excavation in trenches n. exc. 1.5m wide and n. exc.1.5m in depth for laying of under ground cables or pipe line etc., n exc 10 sq m on plan and getting out in hard/dense soil, complete all as specified and as directed.
Surface dressing n. exc. 15cm deep [averaging] and getting out in soft/loose soil, including removal of the rubbish outside MD land, complete all as specified and as directed.
Surface excavation n. exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil, including removal of the rubbish outside MD land, complete all as specified and as directed by the Engineer-in-Charge.
Excavation in trenches n. exc. 1.5m wide and n. exc.1.5m in depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., n exc 10 sq m on plan and getting out in soft/loose soil, complete all as specified and as directed.
Excavation in trenches n. exc. 1.5m wide and exc.1.5m but not exc 3.0m depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., n exc 10 sq m on plan and getting out in soft/loose soil, complete all as specified and as directed.
Excavation in trenches n. exc. 1.5m wide and exc. 3.0m but not exc 4.5m depth for foundations, pile cap, beams, shafts, wells, manholes, pier holes, laying of under ground cables or pipe etc., n exc 10 sq m on plan and getting out in soft/loose soil, complete all as specified and as directed.
Excavation over areas not exc. 1.5m deep for foundations, beams, Pile caps and getting out in soft /loose soil complete all as specified and as directed.
Excavation over areas exc 1.5m deep but not exc. 3.0m deep for foundations, beams, Pile caps and getting out in soft /loose soil complete all as specified and as directed.
Returning, filling in including, spreading, levelling, watering and well ramming in layers n. exc. 25cm thick in soil, complete all as specified and as directed.
Removing excavated soil to a distance exc. 1.5 Km but n. exc. 5.0 Km and depositing where directed at a designated place as approved by GVMC, complete all as specified and as directed.
M&L for Pre construction Anti termite treatment by Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and as directed.
M&L for Pre construction Anti termite treatment by Treating the back and sides of excavation at the rate of 5.0 litres of emulsion per square metre of surface area, complete all as specified and as directed.
M&L for Pre construction Anti termite treatment by Treating the top surface of filled earth at the rate of 5.0 litres of emulsion per square metre of surface area, complete all as specified and as directed.
M&L for Pre construction Anti termite treatment by Treating the soil along external perimeter of the building at the rate of 2.25 litres of emulsion per metre, complete all as specified and as directed.
M&L for Pre construction Anti termite treatment by Treating the soil under plinth protection at the rate of 5.0 litres of emulsion per square metre of plinth protection surface area, complete all as specified and as directed. Note for Item No. 1.028 to 1.032 Only approved chemical shall be used as per IS 6313 (Part-2): 2013 and applicators of ATT are registered by the Pest Control Association of India (PCAI)/ Indian Pest Control Association (IPCA)
M&L for Drilling or boring for 500mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
M&L for Drilling or boring for 600mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
All as per Serial Item No. 1.033 here in before but for 500mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified.
All as per Serial Item No. 1.034 here in before but for 600mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified. Notes for Item Nos. 1.033 to 1.036:- (i) The depth of boring for piles shall be measured from existing ground/sea bed level/river bed top (as per soundings/reduced levels taken at the commencement of work) to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. The distance mentioned in description of item shall be the shortest distance from the centre of the building. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes. (iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in particular specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
M&L for 40mm thick Providing precast cement concrete Jallies [1:2:4 type B0 using 12.50mm graded granite stone aggregate] as in jallies, including all moulding set in CM 1:4, complete all as specified and as directed.
Carrying out initial load tests on test pile of 500mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for 2.5 times of the design load in non-working areas in the vicinity of site, including the cost of new piles for 500mm dia with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile), complete all as specified. Note: Load required for testing as per IS shall be arranged by the contractor and test pile shall be abandoned after testing.
Description all as per Serial Item No. 1.038 here in before but for Carrying out initial load tests on test pile of 600mm dia.
Carrying out routine load test on 500mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 500mm dia Piles for 1.5 times of the design load complete all as specified and as directed.
Carrying out routine load test on 600mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 600mm dia Piles for 1.5 times of the design load complete all as specified and as directed.
M&L for Moorum/red bajri filling under floors or paving's or in foundations, brought from outside MD land laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, complete all as specified and as directed. Note: Measurements of the finished surface of earth filling shall be taken after consolidation and 10% deduction shall be made for increase in bulkage.
M&L for Pre-cast cement concrete [1:2:4 type B1] block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:4, complete all as specified and as directed.
M&L for Hardcore of gauge n. exc. 63 mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface, using broken granite stone complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (using 40mm graded Granite stone aggregate) as in foundation, filling, mass concrete and underneath pile caps, suspended flooring/slab, beams, plinth protection, surface channels, drains etc. complete all as specified and as directed.
M&L for PCC type B0 [1:2:4] using 12.50mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs, surface channel benching/ hunching and the like including weathering, slightly rounded or chamfered angles and throating, finished plain fair faces, complete all as specified and as directed.
M&L for Providing precast cement concrete (RCC) 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in cover slabs for manholes / drains, chajjas, shelves, baffle wall and similar articles set in CM 1:4, finished plain fair faces, including necessary formwork etc., complete all as specified and as directed.
M&L for Reinforced cement concrete 1:2:4 type B0, using 12.5mm graded granite stone aggregate as in wall, basement slab of cable trenches and the like, complete all as specified and as directed.
M&L for Reinforced cement concrete of grade M-40 (Design mix using 20mm graded granite stone aggregate) using ready mix concrete including supply and mixing of admixtures, as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, pile caps, suspended floor beams & slabs, basement slabs, under-reamed piles etc. using Portland slag cement and handling, conveyance, errection with alignment in true position complete all as specified and as directed.
All as per item No.1.050 here-in-before but as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, duct slab and in shelves and the like complete.
All as per item No.1.050 here-in-before but as in columns, Pillars, piers, vertical bands, posts and struts etc complete.
All as per item No.1.050 here-in-before but as in floor beams, roof beams, cantilevers, bressumers, middle beams, lintels over 1.5m span and lintel bands etc complete.
All as per item No.1.050 here-in-before but as in stair.
All as per item No. 1.050 here-in-before but fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, wall and the like complete.
All as per item No. 1.050 here-in-before but as in chajjas and similar works not otherwise specified for, complete. Notes for item Nos. 1.050 to 1.056: (i) Minimum cement content shall be 400 Kg/Cu.m for Item No. 1.050 and 360 Kg/Cu.m for 1.051 to 1.056 items, using PSC cement with minimum slag content of 50% (fifty percent). (ii) Design mix shall be as per IS-456-2000. Maximum size of aggregate shall not exceed 20 mm and slump shall be 50mm to 100mm and maximum water cement ratio 0.4. (iii) Unit rate shall be deemed to include for interalia for preliminary design mix and works test cubes. (iv) Reinforcement shall be measured and paid for separately. (v) In case at the time of mix design cement content is increased beyond minimum content given above, no extra payment will be made. (vi) Standard manufactured cover blocks as per IS should be used, Site cast cover blocks shall not be used.
Chipping of laitance concrete in piles above cut off level upto a maximum of 1m from cut of level and disposal to distance of exc. 10.0Km but n. exc. 15Km and depositing where directed.
M&L for Brick work with fly ash bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work using fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 including supply and fix 2 Nos of 8mm dia bars at every fourth course of brick work, complete all as specified and as directed.
M&L for Use and waste steel formwork to sides of concrete foundations, pile caps, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed.
M&L for Use and waste steel formwork to sides, faces of vertical walls, water tanks, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter and the like for fair finished surfaces of concrete, complete all as specified and as directed by the Engineer-in-Charge
All as per item No.1.061 here-in-before but to fins, lowers, facia and similar articles, complete.
All as per item No.1.061 here-in-before but to soffits of suspended slabs such as roof slabs, floor slabs, waist slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) complete.
All as per item No.1.061 here-in-before but to sides and soffits of floor or roof beams, cantilevers, bressumers, lintel beams, RCC bands, girders etc complete.
All as per item No.1.061 here-in-before but to stair cases with slopping or stepped soffits including risers and stingers (excluding landing) flat etc complete.
All as per item No.1.061 here-in-before but to sides of pillars, posts, struts, columns and the like complete.
All as per item No.1.061 here-in-before but to sides and soffits of chajjas including supports overhangs etc. and splays between floor and beam, chullah hoods, RCC gutter, catwalks, etc., complete all as specified and as directed.
M&L for Use and waste steel form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs etc. exc. 10cm but n. exc. 20cm wide for fair finished surfaces of concrete complete all as specified and as directed.
S&F 200mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150mm long aluminium, anodised barrel tower bolts of extruded section complete all as specified and as directed.
S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section and fixed, complete all as specified and as directed.
S&F 125mm size butt hinges, extruded aluminium alloy with galvanised mild steel pin, anodized and fixed, type B-21 complete all as specified and as directed.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel pin, anodized and fixed, type B-21 complete all as specified and as directed.
S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F for 75mm long Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F for interlocking handles for aluminium sliding windows complete all as specified and directed.
S&F brass mortice locks, vertical type 100mm size 4 levers complete all as specified and as directed.
S&F floor door stopper with rubber shoe 150mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed complete all as specified and as directed.
M&L for Reinforcement in any situation using Corrosion resistant TMT steel bars of grade Fe-500D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips complete all as specified and as directed.
All as per item No. 1.079 here-in-before 6mm dia and upto 8mm dia bars complete.
All as per item No. 1.079 here-in-before but 5mm dia. and over upto and including 12mm dia. as in stirrups, spacers and binders complete.
S&F Factory made solid PVC door frame of size 50 mm x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply and fix in openings as per specification and drawing, complete all as specified and as directed.
S&F aluminium powder coated frame for doors, partitions, windows and ventilators with one or more rebates of extruded built up standard tubular and other section of approved make, according to IS 1868 (Thickness of powder coating not less than 50 micron) fixed with rawal plugs, aluminium anodised screws or fixing with clamps or with expansion hold fasteners including necessary filling up of gaps of junctions at top and bottom and sides with required PVC/neoprene felt etc., aluminium sections should be smooth, rust free, straight mitred and jointed mechanically wherever required including cleat angle, PVC/Neoprene gasket for glazing, paneling, aluminium anodised screws etc. complete all as specified and as directed.
S&F Powder coated aluminium door shutters, sections weight not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing and powder coated aluminium snap beading screws (thickness of powder coating not less than 50 micron) as per architectural drawings complete all as specified and as directed. Note:- Only aluminium shutter for the doors shall be measured in sqm. All the aluminium fittings/fixtures such as butt hinges, tower bolts, handles etc, Pre-laminated particle board and sheet glass shall be measured and paid separately under relevant items
S&F Powder coated aluminium sliding / side hung type window/ ventilator shutters without sash bars, section weighing not less than 0.55 Kg/RM with extruded built up standard tubular and other sections of approved make according to IS (thickness of powder coating not less than 50 micron) including necessary glazing clips weighing not less than 0.124 Kg/RM, for fixing sheet glass anodised aluminium fitting/fixture such as required number of rollers of suitable size, interlocking cleats/plates etc as required for fixing window shutters as per architectural drawings complete all as specified and as directed. Note:- Only aluminium shutter for the windows/ ventilators shall be measured in sqm. Sheet glass and hard ware such as butt hinges, tower bolts, handles etc, shall be measured and paid separately under relevant items
S&F aluminium powder coated Decorative grill for doors, windows and ventilator with one or more rebates including jointing cleats/beading 'U' or 'H' channel for fixing etc. complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F of Stainless Steel pipes or any other sections of grade 304, cut to size, shape, fixed in position as in railing etc., complete all as specified and as directed.
S&F 35mm thick factory made 2nd class hard wood plain, framed, panelled shutters (two panels) with lock rail and panel of 12 mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS - 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed, complete all as specified.
S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410-W (Gde E-250 quality A), complete all as specified and as directed.
M&L for Mild steel in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, channel, angle, CHS, SHS, sag rod, Sag Angle, Z purline, FL plate, Web plate and flat sections) including distance pieces, cleats etc., confirmings to Fe-410-W (Gde E-250 quality A) all as specified and as directed.
S&F Mild steel base plates of any thickness, for coloumn bases, shear key, stiffeners etc., cut to size and shape, conforming to Fe-410-W (Gde E-250 Quality B), complete all as specified and as directed.
M&L Steel rolling shutters, gear operated type with ball bearing with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple, 1.25 mm laths, guide channels and one shop coat of primer, including erected in position, complete all as specified and as directed.
M&L Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and as directed.
M&L for 75mm thick plain cement concrete 1:3:6 type C1 (using 20mm graded hard granite stone aggregate) as in plinth protection, finished even and fair without using extra cement including making construction joints in 3 mtres interval and joint filled with sealing compound complete all as specified and as directed.
M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in floor, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 25mm thick plain cement concrete 1:2:4, type B0 (using 12.50mm graded granite stone aggregate) as in base course for floor, complete all as specified and as directed.
S&F 12mm thick pre-laminated particle board, interior grade, pre-laminated on both sides with decorative choice lamination and fixed in aluminium partitions, doors shutters etc, with aluminium glazing clips complete all as specified and as directed.
M&L for APP water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terrace etc., consisting of following sequences of operations on RCC surfaces; a) Roof slab shall be cleaned thoroughly and apply cement slurry @3 kg/sqm b). applying a cement plaster of 10mm thickness in CM 1:4 mixed with water proofing compound finished smooth. c) Clean the surfaces thoroughly and apply a coat of hot blown bitumen of grade 85/25 @1.2 kg/sqm over bitumen primer @ 0.5 kg/ sqm. d) Polymeric water proofing (Actatic poly propelene) membrane 3 kg/ Sqm and minimum 3mm thick reinforced with polyester non woven fabric (non woven fabric wt. not less than 150 gms/sqm) shall be laid over the entire surfaces. e) A coat of hot blown bitumen of grade 85/25 @1.20 Kg /sqm shall be applied over water proofing membrane and finally it shall be finished with a coat of bituminous aluminium paint @ 0.1 kg/sqm complete all as specified and as directed. Note:- WPC will be measured and paid separately
M & L for 3mm thick aluminium dividing strip of 38mm wide inserted in position in floor/ ramp complete all as specified and as directed.
M&L for Rendering 10mm in CM 1:4 as on fair faces of brick wall or concrete surfaces of any type, finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for Rendering 5mm in CM 1:3 as in ceiling surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Concrete bed with PCC 1:3:6 type C2 (using 40mm graded stone aggregate) to 150mm dia drain pipe, including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed.
M&L for 150mm bore CI drain pipe, laid in trenches and jointed and testing, complete all as specified and as directed.
M&L for 15mm thick Rendering on fair faces of brick work or concrete surfaces in two layers as 10mm thick in cement mortar 1:6 followed by 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instructions and finish the surface even and smooth without using extra cement, complete all as specified and as directed. Note: Supply of WPC will be measured and paid separately.
Supply only Integral Water Proofing Compound.
M&L for preparation of surfaces and applying three coats of white wash on newly plastered surfaces of walls complete all as specified and as directed.
M&L for preparation of surfaces and applying three coats of white wash on newly plastered surfaces of ceilings, complete as specified and as directed.
M&L for applying two or more coats of cement based wall care putty and preparation for obtaining smooth surface and applying Two coats of plastic emulsion paint over a coat of primer on walls including preparation of newly plastered surfaces all as specified and as directed.
M&L for applying two or more coats of cement based wall care and preparation for obtaining smooth surface and applying Two coats of interior emulsion paint over a coat of primer on walls, including preparation of newly plastered surfaces, complete all as specified and as directed.
M&L for applying two coats of exterior emulsion weather proof paint with anti fungal properties over a coat of primer, including preparation of newly plastered surfaces, all as per manufacturer's instructions, complete all as specified and as directed.
Supply and fixing 5.0mm thick sheet glass of ordinary quality with solar control film 25 micron reflective type on one side of approved brand and shade fixed in position with and including PVC/Neoprene gasket for glazing, glazing clips in doors, windows, partitions in squares not exc 0.50 Sqm in each pane etc. complete all as specified and as directed.
All as per item No. 1.114 above but exc. 0.5 Sq.m. each pane.
M&L for preparation of new or previously untreated surfaces of wood or wood based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel or steel based surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for Coloured Glazed ceramic tiles of size 300X200X7mm thick, laid over and including 10mm thick backing coat in CM 1:3, set and jointed in neat cement slurry and pointed in coloured cement in vertical surfaces such as skirting/dado etc., complete all as specified and as directed.
M&L for Coloured Non skid ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exc. 0.06 Sq.m. but n. exc. 0.11 Sq.m, as in floors etc., laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified and directed.
M&L for 10mm thick dark shade coloured vitrified tiles (square/rectangular) polished, double charged, area of each tiles exc. 0.36 Sq.m. but n. exc. 1.0 Sq.m., in floors etc, laid over and including 15mm thick screed bed or bedding layer in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile surfaces, complete all as specified and as directed.
M&L for 10mm thick dark shade coloured vitrified tiles (square/rectangular) polished, double charged, area of each tiles exc. 0.36 Sq.m. but n. exc. 1.0 Sq.m., as in verticle surfaces such as skirting/dado, laid over and including 10mm thick backing coat in CM 1:3, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile surfaces, complete all as specified and as directed.
S&F Machine cut kota stone slab 18-20mm thick as in floors, laid over and including 20mm thick screed bed or bedding layer in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing, complete all as specifed and as directed.
S&F Machine cut kota stone slab 18-20mm thick, as in vertical surfaces such as skirting/dado, laid over and including 15mm thick backing coat in CM 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing, complete all as specifed and as directed.
M&L Machine cut granite slabs of 20mm thick of any type, table rubbed and polished, as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
M&L Machine cut granite slabs of 20mm thick of any type, table rubbed and polished, as in skirting / dado and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
S&F Hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound, jointed and pointed in CM 1:3, mixed with 5% crude oil by weight of cement, complete all as specified and as directed.
S&F Marble tiles [Makrana white] of size 300mmx200mm x 16-18mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing, laid over and including 20mm thick screed bed or bedding layer in CM (1:4) complete all as specifed and as directed.
M&L Machine cut granite urinal partition of size 320mmx700mm x 12mm thick of any type, table rubbed and polished on both sides, including 10mm grooving in wall and embeded in in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and as directed.
S&F Vitreous china Wash down water closet pan EWC (Pedestal pattern), white with 'P'or 'S' trap étc, (excluding flushing cistern and flush pipe) including plastic water closet seat, closed pattern with flat bottom cover, mild steel chromium plated or aluminised hinging device, fixing bolts, etc, complete all as specified and as directed.
S&F PVC valveless, syphonic action type low level flushing cistern, 10 ltrs capacity, white with inlet ball valve, float and handle soft touch type including brackets, PVC flush pipe etc complete fixed with CP brass screws complete all as specified and as directed.
S&F Vitreous China half stall type urinals, white with automatic flushing cistern, urinal spreader and flush pipe, including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including 32 mm dia PVC polythene waste pipe of suitable length from the urinal to trap of below, complete all as specified.
S&F Vitreous china wash hand basin, white, flat back, size 630x450mm, waste coupling and porcelain stopper including brackets including cutting for and pinning in ends of brackets, 40mm dia CP brass waste fittings, complete all as specified and as directed.
S&F PVC connection (high density) 15mm dia 450mm with PTMT nuts both ends with rubber washer, complete all as specified and directed.
S&F 15mm bore Bib tap, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule, complete all as specified and as directed.
S&F 15mm bore chromium plated pillar taps, fancy type, cast copper alloy with capstan heads, screwed down high pressure with or without lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F Stop valve, chromium plated, 15mm bore , fancy type, cast copper alloy, with long shank and cup (concealed), screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, complete all as specified and as directed.
S&F CP brass shower rose of 15mm inlet and 100mm outlet with swivel joint, CP shower arm and CP flange of approved make and quality, complete all as specified and as directed.
S&F 15mm bore Concussive push button tap, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule, complete all as specified.
S&F vitreous china Soap dish, any type, fixed to plugs with chromium plated brass screws, complete all as specified and as directed.
S&F 15mm dia, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed.
S&F 20mm dia, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed.
S&F 20mm dia, Brass ball valve with polethen float, high pressure screwed both ends for iron pipe, complete all as specified and as directed.
S&F CP towel ring of 150mm dia with CP screws with plastic cleats, complete all as specified and as directed.
S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms), complete all as specified and as directed.
S&F Chromium plated health faucet with angular stop cock and 1m length pipe, screwed for iron pipe of 15mm bore, complete all as specified and as directed.
S&F Toilet paper holder of vitreous china box type fixed to walls with chromium plated brass screws complete all as specified and as directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints laid in trenches and floors, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to wall with brackets, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to wall with brackets, complete all as specified and as directed.
S&F PVC (SWR) vent cowl suitable for 110mm bore pipes including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) vent cowl suitable for 75mm bore pipes including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) bend any radius, suitable for 75mm bore pipes, including jointing with solvent, complete all as specified and as directed.
S&F Bottle trap of PTMT suitable for 40mm mm bore pipes having minimum water seal of 25mm (Minimum weight 32mm-260gms/ 40mm-270 gms), complete all as specified.
S&F PVC (SWR) branch pieces, suitable for 110mm bore pipes, (single Y/T), equal or unequal, ordinary or inverted with oval access door including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) branch pieces, suitable for 75mm bore pipes,(single Y/T), equal or unequal, ordinary or inverted with oval access door including jointing with solvent complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/100mm setting and jointing with solvent, complete all as specified and as directed.
S&F PVC (SWR) Floor / Nahani trap 100x75mm, setting and jointing with solvent, complete all as specified and as directed.
S&F SGSW gully trap 150x150mm setting and jointing with solvent to waste pipe, complete all as specified and as directed.
S&F Galvanised steel water tubing 15mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing, complete all as specified and as directed.
S&F Galvanised steel water tubing 20mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors, complete all as specified and as directed.
S&F Galvanised steel water tubing 25mm bore, medium grade conforming to IS:1239 (Part I) including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors, complete all as specified and as directed.
Rolling and consolidation formation surfaces in cutting by using power roller 8 to 12 tonne capacity, complete all as specified and directed.
M&L for 300mm thick Soling with broken boulders or quarried stone interstices filled, surface formed and rolled and consoldated with 8 to 12 tonne power road roller to required gradient and camber, complete all as specified and as directed
M&L for 150 mm thick WBM (Compacted thickness) in two layers of 75mm thick each layer with coarse aggregate of granite stone of grading 2 (63 to 40 mm size), spread rolled and consolidated with power road roller 8 to 12 tonne capacity and rolled to gradient and camber required all as specified and as directed.( Note: Each layer shall be laid, spread and rolled seperately).
M&L for preparing unsurfaced WBM surface by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc., and applying paving bitumen evenly a priming/ tack coat with bituminous primer at 10 Kgs per 10 Sq mtrs, using paving bitumen of VG-30, complete all as specified and as directed.
M&L for Bituminous premixed asphaltic dense concrete 40mm average consolidated thickness with 6% binder content by weight of total mix of VG-30, rolled with 8 to 10 tonne power roller and compacted to required camber and gradient using mechanical paver and Hot mix plant, complete all as specified and directed. Note: Mix design shall be carried out through a government lab. In case if weight of bitumen content is more than the specified, no additional payment will be admissible. However, if bitumen content is less than specified, same shall be adjusted as per relevant SSR item as applicable.
M&L for Applying evenly a priming/tack coat with paving bitumen @ 5 kg per 10 sqm using paving bitumen of VG-30, laid over premixed macadam surfaces, complete all as specified and directed.
M&L for 60mm thick consolidated Premix dense bituminous macadam laid with 4% binder content by weight of total mix of VG-30, rolled with 8 to 10 tonne power roller and compacted to required camber and gradient using mechanical paver and Hot mix plant, complete all as specified and directed. Note: Mix design shall be carried out through a government lab. In case if weight of bitumen content is more than the specified, no additional payment will be admissible. However, if bitumen content is less than specified, same shall be adjusted as per relevant SSR item as applicable.
M&L for Hot applied thermo setting road marking paint 2mm thick, in any shape / size, including preparation of surface and glass beads retro reflective type, complete all as per ASTM standards, complete all as specified and as directed.
S & F 6mm thick Polycarbonate sheet of approved make with sheets of required shape and size with all accessories, fixing hooks, nuts & bolts washers, clips, MS base plate/supporting structure including providing and fixing silicon sealant, gaskets, complete all as specified and as directed.
S & F Turbo Ventilator of Stainless steel with Turbine dia – 760 mm, Neck/ Throat – 610 mm, Height – 460 mm, including Vanes (Blades), Base ring MOC (Mounting ring), bearings with self lubricating resin to ensure frictionless rotation even at lowest wind velocity, Centre Shaft, Inner arms, Outer arms, FRP base plate matching with roof sheet profile, rivets etc., complete all as per Manufacturer’s specification and instructions, complete all as specified and as directed. Make - Turbo Ventilators India/ Bangalore Build Tech Solutions/ Kirby Building systems or its equivalents,
S&F Pre-painted Galvalume sheeting 0.50mm base metal thickness, Cold Rolled steel of 550 Mpa yield strength conforming to IS 513 (1994) with hot dip metallic coating at minimum 150 gm/Sq.m. zinc- aluminium alloy coating mass (55% Aluminium, 43.5% zinc and 1.5% silicon)on both sides, as in roof covering fixed with SDS stitch self tapping screws and washers as shown on drawing, including sealing tape, complete all as per manufacturer's instructions and as directed.
S&F Mild Steel Anchor bolts - M20 (machine made) and connected items with grouting chemical, washers and nuts etc., fixed in position, complete all as specified and as directed.
S&F Mild Steel Anchor bolts - M24 (machine made) and connected items with grouting chemical, washers and nuts, fixed in position, complete all as specified and as directed.
S&F HSFG bolts -M12 (machine made) and connected items with grouting chemical, washers and nuts etc., fixed in position, complete all as specified and as directed.
S&F HSFG bolts -M16 (machine made) and connected items with grouting chemical, washers and nuts etc., fixed in position, complete all as specified and as directed.
S&F HSFG bolts -M20 (machine made) and connected items with grouting chemical, washers and nuts nut etc., fixed in position, complete all as specified and as directed.
M&L for Construction of Soak well, 150 users capacity, in any type of soil, foundation in PCC 1:2:3 well of honey combed and solid in M-25 concrete, RR masonery/ filling with brick bats, reinforced cover with angle iron frame vent shaft and sludge chambers etc complete os size 1.80m x 6.00m as per drawings and complete all as specified and as directed.
M&L for Construction of RCC Septic tank , 150 users capacity, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-40 Design Mix in walls, Base slab, Baffle walls and Roof slab including beams etc with vent shaft, manhole openings with cover connection, etc complete with effective depth of 1.50 meter and overall depth of 3 meter as per drawings and complete all as specified and as directed.
M&L for False ceiling with gypsum board of 12.5mm thick of each panel size 600x600mm fixed with GI frame work, GI perimeter channel size 20 x 30 x 27 x 0.55mm (having one flange of 20mm and another flange of 30mm and web 27mm) along perimeter of ceiling, screwed fixed to wall with help of nylon sleeves and screws at 600mm centre to centre, suspending GI channels of size 15 x 45 x 0.55mm thick ( two flanges of 15mm each and web 45mm) from the soffit at 1200mm centre to centre both ways with ceiling angle soffit cleat of size 25 x 25 x 0.55mm thick fixed to soffit with rawl plug, ceiling section of 65 x 65 x 8mm fixed to the inter mediate channels with the help of connecting clip 2.64mm dia and in direction perpendicular to the intermediate channel at 365 mm centre, fixing gypsum board with screws 230mm centre to centre, including jointing compound joint paper tape and drywall top coat, complete all as shown on drawing No. DGNP[V]/WD/2026-A, Sheet No. 20/23 dated 20-11-2019 and as per manufacturers instructions.
S&F Venation blinds 50mm/70mm cord, operated with 50/70mm slate for indoor use, with all fittings, complete all as specified and as directed.
S&F Special thread nozzle [for injection of grout] 12mm dia, length equal to half the depth of slab, placed in a grid pattern during concreting at a regular intervals not exc 1.50m c/c all over the raft along construction joint, complete all as specified and as directed.
M&L for Non-Shrink polymeric waterproofing grouting compound [ CICO or Equivalent] mixed with cement slurry to be injected through nozzle under pressure not exc 2kg/Sqm, and finally sealed with CICO SOPAPLA or Equivalent, complete all as specified and as directed.
M&L for Machine pressed pre-cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thick, M- 50 grade with grey cement and no pigment, laid over and including 50mm thick sand bed, complete all as specified and directed.
M&L for 150mm thick PCC 1:4:8 type D2 (using 40mm graded granite stone aggregate) as in sub base of floor / hardstanding, complete all as specified and as directed.
M&L for 100mm thick PCC 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in floor / hardstanding, complete all as specified and as directed.
M&L for PCC 1:2:4 type B0 (using 12.5mm graded granite stone aggregate) as in Kerb stones, with necessary form work, complete all as specified and as directed.
M&L for Structural / Curtain glazing with 5/6mm thick reflective toughended coloured glass, aluminium transom / frame work, SS bolts & screws, structural silicone seal, weather seal with backer rod, EPDM gasket, double adhesive tape with all fittings, curtain glazing and openable panel shutters with fittings, complete all as shown on Drwaing No. DGNP(V)/WD/2026-A sheet No. 11/23 dated 20-11-2019, complete all specified and as directed.
Cutting, Felling and Grubbing of tree of girth exceeding 300cm in girth, with and including cutting of trunk, branches, digging out roots, filling holes and leveling off ground, stacking of serviceable material and disposal of u/s material out side MD land and clearing site, complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - I
SCHEDULE "A" PART - II [AIR CONDITIONING]
Supply, fixing and installation of Invertor type split AC [Indoor and Out door units] of capacity 2.0 Ton with in-built ioniser and plasma filter for better indoor air quality, with R-410A and 5 star energy rating, fixed with and including out door stand, copper condenser tubes, drain pipe, including drilling holes and making good the disturbed surface, with cordless remote control unit and testing on completion, complete all as specified and as directed.
S&F Voltage stabilizer of capacity 5.0KVA for automatic operation, suitable for 2 Ton AC, single phase naturally air cooled indoor type and designed for input variation 160V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
S&F Voltage stabilizer of capacity 1.0KVA for automatic operation, suitable for water cooler, single phase naturally air cooled indoor type and designed for input variation 160V to 270V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
Supply, fixing and installation of water cooler of 80/40 Litters storage and cooling capacity per hour with 02 Nos faucet, fully stainless steel body, electric driven AC 230Volt, 50Hz, single phase, complete fittings and testing on completion, complete all as specified and as directed.
S&F Sheet metal clad SPN enclosure with a 3 pin and earth plug & socket type, with and including one single pole MCB 32/20Amp, 10kA, C series, 230Volt with connections, complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - II
SCHEDULE "A" PART - III [INTERNAL ELECTRIFICATION]
M&L for Flame proof [surface/recessed/concealed type] Point wiring with 2 run of 1.5 Sq.mm FRLS PVC insulated unsheathed copper conductor cable with single core multi stranded 1100 V grade confirming to IS 694: 1977, drawn in and including MS ERW conduit of 20mm bore, medium grade with conduit accessories, provision of junction boxes, tees including one run of 1.5 Sq.mm single core FRLS PVC unsheathed cable with multi stranded copper conductor as earth continuity conductor and connected to common earth dolly for one light/fan point controlled by switch, complete all as specified and as directed.
M&L for Flame proof sub main wiring with two runs of 4.0Sqmm PVC FRLS insulated unsheathed copper conductor cable, single core multi stranded 1100Volt along with one run of 4.0Sqmm PVC FRLS insulated unsheathed copper conductor cable with single core multi stranded as earth continuity conductor, drawn through and including 25mm bore MS ERW conduit with accessories, medium grade, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
S&F Flame proof / weather proof rotary type switch of 16Amp, single pole one way , 250 volt, with necessary connections, complete all as specified and as directed.
S&F Flame proof / weather proof switch socket & plug of 16Amp, 2 pole + earth, 250 volt, with necessary connections, complete all as specified and as directed.
S&F Flame proof fluorescent tube light fitting 2x 36 watts, FLP-WP type made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block and including tubes- 02 Nos, connecting with twin core copper conductor cable, complete all as specified and as directed.
S&F Flame proof Sheet metal enclosure for distribution board TPN, 4 way 415 volts, double door type, complete all as specified and as directed, with and including following :- (i) RCCB TPN, 63Amps, Sensitivity 100mA - 01 No (ii) RCCB SPN, 6-32Amps, 10kA - 01 No (iii) MCB SP, 6-32Amps, 10kA - 04 No
S&F Flame proof exhaust fan 450mm sweep 1440 RPM operates in 230 V, heavy duty , single phase with louvers with all accessories and necessary PCC work, complete all as specified and as directed.
S&F Multiple entry junction box of size 400x400x125mm in LM6 or cast iron, including fixing clamps, complete all as specified and as directed.
M&L for Point wiring with 1.5 Sq.mm FRLS PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with factory made MS boxes, modular cover plates with frame for mounting modular switches, including one run of 1.5 Sq.mm single core FRLS PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light/bell/fan point controlled by one way switch, complete all as specified and as directed.
Description all as per Serial Item No. 3.09 here in before but for 5 Amp socket on the same board.
Description all as per Serial Item No. 3.09 here in before but for light / fan point controlled by two way switches complete.
Description all as per Serial Item No 3.09 here-in-before but with 2.5 Sqmm copper conductor cable and 2.5 Sqmm cable as earth continuity conductor for 5Amp independent switch socket point complete.
Description all as per Serial Item No 3.09 here-in-before but with 4.0 Sqmm copper conductor cable and 4.0Sqmm cable as earth continuity conductor for 5/15Amp independent switch socket point complete.
S&F Modular switch, 1 module, single pole two way 5/6 Amp, 230Volt, complete all as specified and as directed.
S&F Modular switch, 1 module, single pole one way 5/6 Amp, 230Volt, complete all as specified and as directed.
S&F Modular switch socket combination, 3 module, 5/6Amp on independent board / same board, 230Volt, complete all as specified and as directed.
S&F Modular switch socket combination, 3 module, 15/16Amp on independent board, 230Volt, complete all as specified and as directed.
S&F Ceiling rose surface bakelite 65x50 mm having two to three terminals, complete all as specified and as directed.
S&F Modular Bell push 5/6Amp, 1 module, 230Volt, complete all as specified and as directed.
S&F Bell buzzer, electronic dingdong type, AC 230Volt, single pole, multipurpose type, complete all as specified and as directed.
S&F Fan regulator electronic, stepped type, modular type suitable for 230 Volt, AC, 50 Hz, complete all as specified and as directed.
S&F Ceiling fan 1200mm sweep of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable down rod, flexible cable suitable for 230 Volt, AC 50 Hz, complete all as specified and as directed.
S&F Exhaust fan 450mm sweep, 1440 RPM operates in 230Volt, heavy duty, single phase with louvers with all accessories and necessary PCC work, complete all as specified and as directed.
S&F Exhaust fan 300mm sweep, 900RPM operates in 230Volt, heavy duty, single phase with louvers with all accessories and necessary PCC work, complete all as specified and as directed.
S&F Air Circulator fan 450mm sweep of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable clamp, flexible cable suitable for 230 Volt, AC 50 Hz, complete all as specified and as directed.
S&F Energy saving environment friendly high bay LED light Luminaire of 140Watts, 230 volts with high Pressure Die Cast Housing and IP 66 protection complete with all accessories clams, nut&bolts etc., and internally pre wired and connecting up with three core twisted flexible copper conductor cable with suitable size, with and including 140Watt LED tube, complete all as specified and as directed. Make: Cat No. LHB11-140-CDL/60-M of CG or Equivalent in Bajaj/ Havel's/Phillips as approved.
S&F 20 Watt LED light fitting of compact structure surface/recess mounted Decorative type complete with all accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size, with and including 20Watt LED tube, complete all as specified and as directed. Make: Cat No. LDL-20-CDL of CG or Equivalent in Bajaj/ Havel's/Phillips as approved.
S&F 10Watt LED light fitting of compact structure surface / recess mounted Decorative type complete with all accessories internally pre wired and including connecting up with three core twisted flexible copper conductor cable with suitable size, with and including 10Watt LED tube, complete all as specified and as directed. Make: Cat No. LDL-10-CDL of CG or Equivalent in Bajaj/ Havel's/Phillips as approved.
M&L for Circuit / Sub main wiring with two runs of 2.50Sqmm PVC FRLS insulated unsheathed copper conductor cable, single core multi stranded 1100Volt along with one run of 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor cable with single core multi stranded as earth continuity conductor, drawn through and including rigid PVC conduit of suitable size, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
M&L for Circuit / Sub main wiring with two runs of 4.0Sqmm PVC FRLS insulated unsheathed copper conductor cable, single core multi stranded 1100Volt along with one run of 4.0Sqmm PVC FRLS insulated unsheathed copper conductor cable with single core multi stranded as earth continuity conductor, drawn through and including rigid PVC conduit of suitable size, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
M&L for Circuit / Sub main wiring with two runs of 6.0Sqmm PVC FRLS insulated unsheathed copper conductor cable, single core multi stranded 1100Volt along with one run of 6.0Sqmm PVC FRLS insulated unsheathed copper conductor cable with single core multi stranded as earth continuity conductor, drawn through and including rigid PVC conduit of suitable size, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
M&L for Circuit / Sub main wiring with Four runs of10.0Sqmm PVC FRLS insulated unsheathed copper conductor cable, single core multi stranded 1100Volt along with one run of 10.0Sqmm PVC FRLS insulated unsheathed copper conductor cable with single core multi stranded as earth continuity conductor, drawn through and including rigid PVC conduit of suitable size,, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, complete all as specified and as directed. Note: Four runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
S&F MCB DB, TPN 4 ways with IP 44 protection, double door, sheet steel phosphetised powder painted with 200 amps rated busbar 415Volt, complete all as specified and as directed.
S&F MCB DB, TPN 8 ways with IP 44 protection, double door, sheet steel phosphetised powder painted with 200 amps rated busbar 415Volt, complete all as specified and as directed.
S&F MCB DB, SPN 8 ways with IP 44 protection, double door, sheet steel phosphetised powder painted with 200 amps rated busbar 230Volt, complete all as specified and as directed.
S&F MCB DB, SPN 12 ways with IP 44 protection, double door, sheet steel phosphetised powder painted with 200 amps rated busbar 230Volt, complete all as specified and as directed.
S&F Vertical DB TPN with and including 100Amp MCCB 4Pole, 25kA as incomer, 8 ways with IP 44 protection, double door, sheet steel phosphetised powder painted with 200 amps rated busbar 415Volt, complete all as specified and as directed.
S&F MCB DP 6-32Amp, 10kA, 230Volt, C series with necessary connecting up in MCB DB, complete all as specified and as directed.
S&F MCB SPN 63Amp, 10kA, 230Volt, C series with necessary connecting up in MCB DB, complete all as specified and as directed.
S&F MCB SPN 32Amp, 10kA, 230Volt, C series with necessary connecting up in MCB DB, complete all as specified and as directed.
S&F MCB SP 6-32Amp, 10kA, 230Volt, C series with necessary connecting up in MCB DB, complete all as specified and as directed.
S&F MCB TPN 63Amp, 10kA, 415Volt, C series with necessary connecting up in MCB DB, complete all as specified and as directed.
M&L Rigid non-metallic PVC conduit 20mm bore, medium grade, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, etc., for telephone cable provision, complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 25mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
SUB TOTAL OF SCHEDULE "A" Part - III
SCHEDULE "A" PART - IV [LIGHTINING PROTECTION]
S&F Air termination, single pointed, copper rod 12 mm dia and 300 mm long, complete all as specified and as directed.
S&F Copper strip 20mm x 3.0mm complete with saddles and fixing screws etc for roof or on wall conductors and down conductors above/ under ground including porcelain insulators, complete all as specified and as directed.
M&L for Test point terminal block of size 75mm x 75mm x 25 mm, made of gun metal or phosphorus bronze, drilled and screwed with and including 3 nos 8 mm dia 25mm long hex head screw and terminal box of suitable size, complete all as specified and as directed.
M&L for Earthing complete with Copper earth plate electrode 600mm X 600mm X 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth lead 20mm x 3mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1, 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe light grade for copper earth strip 20mm x 3mm, including testing after completion, complete all as specified and directed. Note: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
SUB TOTAL OF SCHEDULE "A" Part - IV
SCHEDULE "A" PART - V [EXTERNAL ELECTRIFICATION]
Supply and spreading river sand in trenches as cushioning to under ground cable on top and bottom of cable and levelling & ramming, complete all as specified and as directed. Note:- Punned thickness will be measured.
Supply and laying un-reinforced precast concrete cable cover, class LV, type-I, flat, size 250mm x 150mm x 40mm laid in trenches for cable protection, complete all as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover, class HV, type-I flat, size 300mm x 180mm x 40mm laid in trenches for cable protection, complete all as specified and as directed.
Supply, laying, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable [ heavy duty] of size 3core x 300 Sqmm, with stranded aluminium conductor, 11000 volts grade, with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified and as directed.
Supply, laying, testing and commissioning of LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable [heavy duty] of size 3.50core x 500 Sqmm, with stranded aluminium conductor, 1100 volts grade, with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 3.50core x 400 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 3.50core x 240 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 3.50core x 120 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 3.50core x 95 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 3.50core x 50 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 4.0core x 25 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 4.0core x 16 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 2.0core x 16 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 3.50core x 70Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 4.0core x 10 Sqmm, complete all as specified and as directed.
Description all as per Serial Item No. 5.05 here in before but for LT cable of size 4.0core x 6 Sqmm, complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination, cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint, complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 Sqmm, complete all as specified and as directed.
S&F Danger notice plate for HT of size 250mmx200mmx 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, complete all as specified.
S&F 100mm dia GI pipe, light grade for cable protection laid in trenches or fixed to walls / poles including necessary MS clamps, bolts, nuts, fasteners as required, complete and directed.
S&F LED 90 Watts roadway luminaire new generation, energy saving versatile high Pressure Die Cast Housing and IP 66 protection, with suitable GI pipe bracket with clamps, all accessories and internally pre wired and connecting up with three core twisted flexible copper conductor cable with suitable size, complete all as specified and as directed. Make : Cat No. LSTP-90-CDL -M of CG or or Equivalent in Bajaj/ Havel's/Phillips as approved.
M&L for Steel tubular swaged pole 8.50m long, complete with cast iron base plate, finial taper and single swan neck, including fixing arrangement bolts, nuts & screws, for 410 SP-22 (8.50 mtr long ) pole, FRP Box with MCB of suitable capacity, complete all as specified and directed. Note: All Civil works i.e earth work and PCC will be measured and paid separetely under relavent items in Schedule "A"Part-I.
M&L for Chemical earthing complete with copper earth plate electrode 900mm X 600mm X 5mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth lead 32mm x 6mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I, including excavation/earth work in any strata, with supply of fast Electrode Earth Enhancement compound ( 2 Bags of 25 KG ) which is highly hygroscopic, non corrosive & good pH value certified by NABL approved lab, PCC chamber with RCC cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe medium grade for copper strip protection and 32mm x 6mm copper strip, including testing on completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
M&L Rigid non-metallic PVC conduit 25mm bore, medium grade, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, etc., complete all as specified and directed.
M&L for SYNTHETIC INSULATING MAT of size 2m x 1m x 25mm thick, of approved colour and design, complete all as specified.
Supply, install, testing and commissioning of Transformer of capacity 1000KVA, step-down, 11/0.433 KV, outdoor type oil cooled copper wounded level 2, complete with all standard accessories, 11 KV 3 Phase on HT side and 433 volts 3 Phase on LT side, suitable for continuous duty for operation on AC 3 phase 50 Hz with off load tap changer on HT side in 7 steps with +/- 2.5% distribution transformer, level 2 and transformer oil up to appropriate level all as per IS :1180 with latest amendments, with and including all jointing materials, connecting with electrical system, testing and commissioning, steel mounting fabrications, civil foundation as per IS & manufacturer recommendation, complete all as specified and as directed.
Supply, install, testing and commissioning of HT 11 KV 3 phase 50 cycles, outdoor type, 50 HZ totally enclosed metal clad switchgear, complete with and including Vacuum circuit breaker of rating 630Amps, having rupturing capacity upto 350 MVA, with overload and earth fault protection, ammeter, voltmeter, connecting with electrical system, testing and commissioning, steel mounting fabrications, civil foundation as per IS & manufacturer recommendation, complete all as specified and directed.
Supply, install, testing and commissioning of HT 11 KV 3 phase 50 cycles, indoor type, 50 HZ totally enclosed metal clad switchgear, complete with and including Vacuum circuit breaker of rating 630Amps, having rupturing capacity upto 350 MVA, with overload and earth fault protection, ammeter, voltmeter, connecting with electrical system, testing and commissioning, steel mounting fabrications, civil foundation as per IS & manufacturer recommendation, complete all as specified and directed.
M&L for Cable root indicator for cable root marker, made out of cast iron round shape of 100mm dia, with supporting length of GI flat 20mm wide and 6mm thick and 750mm long, duly marked with word such as LT Cable/ HT Cable as indicated or directed, duly painted with two coats of super enamel silver colour, including grouting in ground 300mm x 300mm x 300mm deep with and including cement concrete 1:2:4 (Type B1) using 20mm graded granite stone aggregate, complete all as specified and directed.
Taking down existing UG cable of any size by disconnecting the joints / cutting for diversion in any location including earth work excavation and making good the disturbed portion, complete all as specified and directed.
S&F GI strip 32 x 6.0mm complete with saddles and fixing screws etc for roof or on wall conductors and down conductors above/ under ground including porcelain insulators, complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 25 x 4mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 40mm bore GI pipe medium grade for GI strip protection and 25 x 4mm earth strip, including testing after completion, complete all as specified and directed. Note: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
SUB TOTAL OF SCHEDULE "A" Part - V
SCHEDULE "A" PART - VI [EXTERNAL WATER SUPPLY]
Taking down existing GI/CI/DI pipe line including all fittings, of size 40mm to 80mm, including dismantling joint / cutting as required, complete all as specified and as directed.
Taking down existing GI/CI/DI pipe line including all fittings, of size 100mm to 200mm, including dismantling joint / cutting as required, complete all as specified.
M&L for Cutting DI/CI pipe upto 200mm dia and reducing to required length before laying, including inserting new tees, bends, branche etc., complete all as specified.
Supply, laying, testing and commissioning of Ductile Iron pressure pipe of 100mm bore with spigot and socket ends and confirming to IS-8329:2000, class K-9, PN-10 rating, with pipe lining inside with cement mortar (CML) outside with bituminous coating all as per Annx `C' of IS-8329, laid in trenches / floor, complete all as specified and as directed. Note: 1. Necessary earth work will be measured and paid separately. 2. Necessary fittings will be measured and paid separately.
M&L for DI Specials such as Bends , tapers any type, Tee pieces, single branch, "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs for connecting up to 200mm bore DI Pipe all as per IS:9523, complete all as specified and as directed. Note: Fittings shall be of same grade and class as per main pipe.
Supply, laying, testing and commissioning of Stainless steel SS water tubing 100mm bore, SS 316 grade, Sch 10 pipe, ISI marked, including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
Supply, laying, testing and commissioning of Galvanised steel water tubing 80mm bore, medium grade conforming to IS:1239 (Part I), including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
All as per Serial Item No. 6.07 here in before but for 50mm bore.
S&F Gun-metal, globe or gate valves, suitable for 50mm bore with iron wheel head, screwed at both ends for iron pipe, complete all as specified and as directed.
S&F Cast Iron Non return Sluice valve suitable for 100mm bore, flanged of class PN 1.6, rubber lined, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F Cast Iron Air release valve suitable for 100mm bore, flanged of class PN 1.6, rubber lined, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
Supply, Install, testing and commissioning of Stainless Steel pumping set, electrically driven, centrifugally type conforming to IS with casing, impeller and stainless steel shaft mounted on heavy duty bearings, suitable for continuous operation with range of operation 0% to 150% of rated capacity for 440V, 3 phase, 50Hz, 40mtr head, 20Cum/Hr discharge, with and including DOL starter, SS butterfly valve with fittings, necessary MS frame and PCC foundation as per OEM Specification, complete all as specified and as directed.
Supply, Install, testing and commissioning of pumping set, electrically driven, centrifugally type conforming to IS with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings, suitable for continuous operation with range of operation 0% to 150% of rated capacity for 440V, 3 phase, 50Hz, 30mtr head, 450 LPM discharge, with and including DOL starter, necessary MS frame and PCC foundation as per OEM Specification, complete all as specified and as directed.
S&F Water Pressure gauge of standard dia 4"dial 0-40 kg / cm2 rating, fixed with stop cock of suitable size at delivery side of pump set, complete all as specified.
M&L for Valve chamber of size 1000mm x 1000mm x 1000mm internal dimensions, with and including excavation in any type of soil, spreading, levelling and refilling etc. PCC (1:4:8) type D2 for foundation, Fly ash brick work of one brick thick wall in CM (1:4) including internal plaster 15mm thick in CM (1:4) external plaster 15mm thick(1:4) and providing coping in PCC (1;2:4) type B1, angular iron frame of size 50x50x6mm with 6mm thick MS plate cover complete including locking arrangements and having FRP coating of 2mm thick on both inside and outside surfaces, complete all as specified and complete with all necessary fittings shown in drg No. DGNP/TD/157(R) Sht No. 1/1 dated 20-05-2005.
SUB TOTAL OF SCHEDULE "A" Part - VI
SCHEDULE "A" PART - VII [FIRE FIGHTING & SMOKE DETECTOR SYSTEM]
M&L for Cutting DI/CI pipe upto 300mm dia and reducing to required length before laying and inserting new tees, bends, branch etc., complete all as specified and as directed.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 150mm bore, as per IS:1239 (Part-I), medium grade with IS mark with and including two coats of approved enamel paint over a coat of primer on exposed portion, including all fittings of heavy grade as per IS:1239 (Part-II) and laid under trenches/floor /fixed to wall and clamping including testing, complete all as specified and as directed.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 100mm bore, as per IS:1239 (Part-I), medium grade with IS mark, including all fittings of heavy grade as per IS:1239 (Part-II) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 80mm bore, as per IS:1239 (Part-I), medium grade with IS mark, including all fittings of heavy grade as per IS:1239 (Part-II) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 50mm bore, as per IS:1239 (Part-I), medium grade with IS mark, including all fittings of meadium grade as per IS:1239 (Part-I) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 25mm bore, as per IS:1239 (Part-I), medium grade with IS mark, including all fittings of meadium grade as per IS:1239 (Part-I) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
S&F Cast Iron Non return Sluice valve suitable for 150mm bore, Wafer Type slim, flanged of class PN 1.6, rubber lined, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F Cast Iron Sluice valve suitable for 150mm bore, flanged of class PN 1.6, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F Cast Iron Sluice valve suitable for 100mm bore, flanged of class PN 1.6, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F Cast Iron Sluice valve suitable for 80mm bore, flanged of class PN 1.6, including brass spindle and necessary fixing arrangement like rubber gasket etc., complete all as specified and as directed.
S&F Cast Iron Butterfly valve suitable for 80mm bore, conform to BS:5155, MSS SP 67 & APT 609, including necessary fixing arrangement, complete all as specified and as directed.
S&F Cast Iron Foot valve suitable for 150mm bore, shall conform to IS:4038-1986, fitted with a Y strainer which will have cored holes / slotsand, including necessary fixing arrangement, complete all as specified and as directed.
S&F Brass ball valve suitable for 25mm bore with polethen float, high pressure type, and shall conform to IS 1703: 2000, screwed both ends for iron pipe, complete all as specified and as directed.
Supply, Install, testing and commissioning of Fire pump, diesel engine driven horizontal end suction, centrifugal type confirming to IS- 12469: 1988, with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440Volt , 3phase, 50 Hz AC supply 70m Head, 2280LPM discharge, with and including PCC foundation as per OEM Specification, complete all as specified and as directed.
Supply, Install, testing and commissioning of Fire pump electrically driven horizontal end Suction, centrifugal type confirming to IS- 12469:1988, with CI Casing, bronze impeller and Stainless steel shaft, mounted on heavy duty bearings suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440Volt , 3Phase, 50 Hz AC supply 70m Head, 2280 LPM discharge with and including PCC foundation as per OEM Specification, complete all as specified and as directed.
Supply, Install, testing and commissioning of Jockey pump horizontal end suction centrifugal type Confirming to IS- 12469: 1988, with CI casing , bronze impeller and stainless steel shaft, mounted on heavy duty bearings suitable for automatic operation with non-over loading type power characteristics for frequent start / stop operations for 440Volt , 3 phase, 50 Hz AC supply, 70m head, 180 LPM discharge, with and including PCC foundation as per OEM Specification, complete all as specified and as directed.
S&F Water Pressure gauge of standard dia 4"dial 0-100 kg / cm2 rating, fixed with stop cock of suitable size at delivery side of pump set, complete all as specified.
Supply, install, test and commissioning of electrical operated water pressure switch with necessary mounting / connection with control wiring with conductor and mechanical connection to operate at pressure range of 0 to 10Kg/Sq cm for automation, complete all as specified.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 40mm bore, as per IS:1239 (Part-I), medium grade with IS mark, including all fittings of meadium grade as per IS:1239 (Part-I) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
Supply, laying, testing and commissioning of Mild Steel ERW pipe of 32mm bore, as per IS:1239 (Part-I), medium grade with IS mark, including all fittings of meadium grade as per IS:1239 (Part-I) and laid under trenches / floor, fixed to wall etc., and clamping including testing, complete all as specified and as directed.
S&F Stainless Steel fire hydrant valve, type 'A' (single head outlet ) suitable for 63mm bore, confinming to IS-9250, complete all as specified and as directed.
S&F Fire hose of synthetic fiber 30mtrs, 63mm bore as per IS:636 with and including gunmetal coupling (male and female parts) with copper winding, confirming to IS:903, complete all as specified and as directed.
S&F Hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet, painted fire red out side and brilliant white inside yard for fixing 2 Nos of hose pipes of length 15 mtr each, complete all as specified and as directed.
S&F Fire hydrants stand post 80mm Dia GI / MS both flanged type, 1.5m Height with provision of single outlet, confirming to IS-908, complete all as specified and as directed.
S & F Branch pipe gun metal suitable for 63mm bore, instantaneous inlet, made threaded outlet, 15mm bore nozle short, complete all as specified and as directed.
M&L for angle iron frame work, bracings, supports, clamps and back plates fabricated from angle iron sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts and inclusive of one primer coat, one under coat and one finishing coat of paint, confirming to Fe-410-W (Gde E-250 quality A), complete all as specified and as directed.
S&F 150mm bore 3 way fire brigade, inlet with isolation valve with instantaneous SS coupling, 63mm dia with required fittings, complete all as specified and as directed.
S&F Terrace pump of 450 LPM discharge with 3.5 Kg/cm2 pressure along, with CI Casing, bronze impeller and Stainless steel shaft, mounted on heavy duty bearings, with and including Outdoor type electrical control panel and necessary cabling, control wiring for auto operation through pressure switch and civil foundation, complete all as specified and as directed.
M&L for Circuit / Sub main wiring with two runs of 1.50Sqmm PVC FRLS insulated unsheathed copper conductor cable, single core multi stranded 1100Volt along with one run of 1.50Sqmm PVC FRLS insulated unsheathed copper conductor cable with single core multi stranded as earth continuity conductor, drawn through and including rigid PVC conduit of suitable size, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, complete all as specified and as directed. Note: Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit.
S & F Microprocessor based analogue networking type clean agent release panel with 2 x 16 Alpha numeric LCD display as per IS : 2189/ NFPA 72, complete all as specified and as directed with following:- [a] Gas release module [b] Emergency release switch [c] Abort switch. Note: Gas release panel integration with fire alarm panel with central monitoring through LAN / GPRS.
Supply, Install, testing and commissioning of Vacuum pump with 3HP motor three phase, with auto DOL starter, wiring with suitable size copper conductor cable from LT panel to starter and to motor, civil foundation as per the manufacturers recommendation, complete all as specified and as directed.
S&F of 80 ltr cylinder with valve assembly, complete all as directed.
S&F of clean agent [filled in above cylinder], complete all as directed.
S&F of solenoid actuator assembly 24V DC, complete all as specified.
S&F of manual actuator complete all as specified.
S&F of discharge hose complete all as specified.
S&F of 80 ltr cylinder strap complete all as specified.
S&F of nozzles complete all as specified.
S&F of Pneumatic actuator assembly complete all as specified.
S&F of manifold with two check valves complete all as specified.
S&F of manifold with one check valves complete all as specified.
S&F of Pilot hose assembly complete all as specified.
S&F of master cylinder adopter - ENOT, complete all as specified.
Supply, Install, testing and commissioning of Fire fighting water / foam monitors complete all as specified and as directed with following:- [a] Size 63mm [b] Service pressure 6 - 12 Kg/cm2 [c] Flow range : 1500 - 3000 LPM [d] inlet Flange : 100 NB [e] Rotation : 360 degree, capable of rotating vertical & horizontal [f] Material Construction: MS seamless pipes to IS : 1239 [g] Swivel joints confirming to IS : 318LTB-II [h] Nozzle: Aluminium alloy Nozzle as per IS : 617 or SS as per IS : 3444 [j] Hydro tested to 23 Kg/cm2 [k] approximate performance (at 7 Kg/cm2) = Flow 1750 LPM and range of 53 Mtrs [l] capable of discharging water as well as foam [m] 100mm bore CI sluice valve with fittings, including civil foundation, fixed in position, complete all as specified and as directed.
S&F Multi sensor detector comprises optical smoke detector and thermister temperature sensor, complete all as specified and as directed.
S&F Resetting type Deluge valve model-A, for Vertical inlet to Horizontal outlet mounting, cast iron material flanged end to ANSI B16.1, Class 125, with trim, Size 100 NB, complete all as specified and as directed.
S&F 24Volt solenoid valve of 1/2" port complete all as specified.
S&F addressable dual action manual pull station, single action connected with back box, complete all as specified and as directed.
S&F Loop sounder visual indicator controlled by full core protocol with fire control panel programme accordingly, complete all as specified.
Supply, installation and commissioning of repeater alarm panel for fire detection and alarm system suitable for GSM/GPRS/ necessary SCADA software, complete all as specified and as directed.
Supply and fixing Atmospheric foam concentrate storage tank with expansion dome with UL listing:- Mounting : Vertical / Horizontal, Material : SS 304, Thickness : 4mm flat ends, FRP from inside thickness 1.5/3/4mm, Capacity : 1000 Liters, Epoxy painted from outside as per NFPA 16, complete all as specified and as directed.
Supply, installation and commissioning of Atmospheric Foam Concentrate Storage Tank of 1000 litres capacity, Vertical / Horizontal mounting, 4mm thick with stainless steel of grade SS304, 1.5/3/4mm thick walls, coated with FRP inside, Epoxy painted from outside as per NFPA16, with expansion dome and flat ends, complete all as specified and as directed.
S&F of inline Foam Inductor made out of Aluminium with CS flanges, size : 100 NB, foam concentrate induction rate 3 or 6%, complete all as specified and as directed.
S&F of water/foam sprinkler, in brass material 1/2" BSPT end connection, Pendent type with UL and C UL listed, FM, LPCB and NYC approved maximum working pressure 175psi, as per NFPA 13, complete all as specified and as directed.
S&F of Foam chamber model - FC with vapour seal chamber, inlet 80NB and outlet 150NB, flow - 650LPM @ 3 Kg / Cm2 pressure, Foam Deflector Model- FD for Foam Chamber, complete all as specified and as directed.
Supply of AFFF foam 3% concentrates, complete all as specified and as directed.
S&F AFFF type fire extinguishers - mechanical foam type 9 litres capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets, etc., complete all as specified.
S&F CO2 fire extinguishers - 4.5 Kg capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets etc confirming to IS : 15683 with ISI mark, complete all as specified.
S&F Dry Chemical Powder fire extinguishers - 6.0 Kg capacity, complete with initial charge, gun metal cap, discharge hose with nozzle, wall fixing brackets etc confirming to IS : 15683 with ISI mark, complete all as specified.
S&F Sand bucket with round bottom, complete all as specified.
S&F Water bucket with round bottom, complete all as specified.
Supply, installation and commissioning of addressable type open area smoke imaging fire detector comprising of 4 wire system with infrared emitter and receiver in a single housing and four reflector plates 5-100mtrs range equipped with built in automatic compensation -in -built laser light for easy alignment-option for remote indication - three sensitivity threshold of 18%, 30% and 50% to be installed at boiler area, complete all as specified and as directed.
S&F QBD 57 degree centigrade complete with following required fittings complete all as specified and as directed:- (a) Material of construction high tensile brass forging (b) Heat sensitive bulb : Quartzoid (Dia 8 mm) (c) Deflector : Brass to IS : 319 (d) Test Pressure : 30 kgs/cm2 (e) Working pressure : 12.4 kgs/cm2 max (f) Bulb temp range and colour : 57 deg C /135 deg F orange (g) Finish : Brass / Nickel & Chrome plated (h) Net weight : 0.800 kgs (j) QBD 57 degree centigrade
S&F Gun-metal, globe or gate valves, suitable for 40/50mm bore with iron wheel head, screwed at both ends for iron pipe, complete all as specified and as directed.
S&F Cast Iron Foot valve suitable for 100mm bore, shall conform to IS:4038-1986, fitted with a Y strainer which will have cored holes / slotsand, including necessary fixing arrangement, complete all as specified and as directed.
S&F 150mm bore 4way fire brigade, inlet with isolation valve with instantaneous SS coupling, 63mm dia with required fittings, complete all as specified and as directed.
S&F Y Strainer 100mm with required fittings, complete all as specified and as directed.
S&F Y Strainer 150mm with required fittings, complete all as specified and as directed.
S&F Emergency release push button stations, complete all as specified and as directed.
S&F Addressable type Manual Call Point, resettable type, complete all as specified and as directed.
S&F Warning Sign LED type, complete all as specified and as directed.
S&F Trim Kit net type compatible for deluge valve for auto / manual electrical operation, complete all as specified and as directed.
SUB TOTAL OF SCHEDULE "A" Part - VII
SCH "A" PART-VIII [LIFT]
SUB TOTAL OF SCHEDULE "A" Part - VIII
anjaliinfratech
RAJYALAKSHMI BUILDERS
S V S ENTERPRISES
K KUMAR RAJA PROJECTS P LIMITED
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
SVS PROJECTS
RKEC Projects Limited
jd constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid