| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.1 LAccepted-AOC D NO 58 13 74 10 GF 111 VASAVI PARADISE GOWRI NAGAR WARD NO 42 NAD POST VISAKHAPATNAM 530009 AP | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹5.8 L+₹67,392.18 (13.3%)Rejected-Finance D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹7.0 L+₹1.9 L (36.9%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹7.4 L+₹2.3 L (44.8%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹7.9 L+₹2.8 L (55.2%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹8.0 L
EMD Value
₹16,100
Closing Date
19 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) VARSHA
GE (P) Varsha Director General Naval Project Naval Base Post Visakhapatnam 530014
PROVISION OF 160 KVA OIL COOLED SERVO VOLTAGE STABILIZER AT NCN CENTRE AOB RAMBILLI, VISAKHAPATNAM.
2024_MES_647596_1
GE(P) VARSHA/ TOKEN/13 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Rambilli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
DGNP
₹16,100
Yes
7 Jun 2024
22 Mar 2024
22 Apr 2024
22 Mar 2024
19 Apr 2024
5 Apr 2024
Amount
Supply fixing, testing and commissioning of micro controller based servo Voltage stabilizer for automatic and mannual operation, three phase,single phase prevention, naturally oil cooled, indoor type & designed for input variation between 360 V to 460 V with output voltage stabilized at 3 Phase 415V, 50Hz with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 160 KVA with suitable input MCCB, output Contactor, bypass switch & spike suppresssor conforming to applicable IS standards including civil foundation as per OEM recommendation complete all as specified and directed by Engr-in-Charge. The following specifications are inclusive of quoted rates: (a) Working temperature - 0-55 Degree C, (b) Temperature- 0-60 Degree C,(c) Speed of correction - less than 10 milliseconds, (d) System operation - Auto/Manual, (e) Single phase prevention & (f) Phase reversal tip etc.
Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip or wire armoured electric power cable [heavy duty] of size 3.5core x 185.00Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches/wall/floor/roof/tray or ducts or through the pipe etc. complete all as specified and as directed.
Excavation in trenches n. exc. 1.5m width and n. exc. 1.5m in depth for foundation, trenches for laying cables and getting out in soft/loose soil.complete all as specified and as directed by Engineer in charge.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and as directed by Engineer in charge.
Removing excavated materials to a distance n exc. 50m and depositing where directed at a level n. exc 1.50m above the starting point complete all as specified and as directed by Engineer in charge.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed by Engineer in charge. (Note: Punned thickness only shall be measured)
Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250mmx150mmx40mm all as specified and directed by Engr-in-Chage.
M&L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanised iron strip of size 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised iron or steel, earth strip protected by and including GI pipe 40mm dia bore (light grade) and connected to main test point as directed including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:1½:3) type A-1 cover slab of size 54 x54 x 5 cm reinforced with 8mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, made out of 8mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20mm bore GI pipe (medium grade) for watering, charcoal and salt in alternate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR Part-I and testing incl taking down old complete all as specified and as directed. NOTE- The earth resistance should be less than 01 Ohm.If satisfactory resistance not obtained after testing , earthing shall be redone by the contractor at his own cost.
P VENKATA RAO
Jessica Engineering Works
K C ENTERPRISES
L-7 Primewave Communications
ANJANA ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .