Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹28.4 L+₹3.3 L (12.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹33.6 L+₹8.4 L (33.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹33.9 L+₹8.7 L (34.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
3 Nov 2020, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
AS PER BOQ AND TENDER DOCUMENTS
2020_MES_383892_1
8700/GE FORT KOCHI/E8
Open Tender
Civil Works
Item Rate
270 days
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹76,000
Yes
17 May 2021
6 Oct 2020
7 Nov 2020
7 Oct 2020
3 Nov 2020
20 Oct 2020
7 Oct 2020 - 14 Oct 2020
Amount
M&L opening the manhole of septic tank, remove night soil and sediments including liquid by mechanical pumping into tanker lorry, cleaning internal surface with water and re-fix the manhole covers, taken away night soil & sediments from the respective vicinities on covered conveyance and dispossed off outside MoD land complete all as directed. Note:- Volume of septic tank will be worked out based on the depth excluding free board or actual depth of sludge, whichever is less.
M&L opening the intercepting chambers of any size, remove night soil and sediments including liquid by mechanical pumping into tanker lorry, cleaning internal surface with water and taken away night soil & sediments from the respective vicinities on covered conveyance and dispossed off outside MoD land complete all as directed. Note:- Volume of intercepting chamber will be worked out based on the depth or actual depth of sludge, whichever is less.
M & L cleaning (mechanically) of sewage line/effluent drains of any dia complete all as directed.
M&L for opening manholes of any size, remove night soil and sediments including liquid mechanically, cleaning internal surface with water, taken away night soil & sediments from the respective vicinities on covered conveyence and disposed off outside MoD land complete all as directed. Note:- (i) Volume of manhole will be worked out based on the depth or actual depth of sludge, whichever is less. (ii) Water shall be procured by the contractor for cleaning purpose.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate, smooth finished and reforming benching as required complete for 150mm bore pipe all as specified and directed.
Cleaning the existing covered drains after removing the RCC covers of width exceeding 250mm and not exceeding 600mm by clearing all rubbish soil and vegetation (average depth 150mm) removing and depositing the debris to a distance not exceeding 150m and refixing the covers to its original position complete all as specified and directed.
Cleaning the existing drains of width exceeding 250mm and not exceeding 600mm by clearing all rubbish soil and vegetation (average depth 150mm) removing and depositing the debris to a distance not exceeding 150m and refixing the covers to its original position complete all as specified and directed.
M&L for destruction of growth of weed plants with root level on wall/ roof of building any height with weedicides such as 'Round up" manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possibe growth of weeds as per manufacturer instructions and making good the surface complete all as specified and as directed. Notes : (i) In case of plants that has tree like growth , the plants shall be cut very near the roof/wall and rest treated with chemical solution. (ii) Area after treatment shall be cleared of all debris, branches, dead plants etc.
M & L removing the chokes in drains of WC/bath room/kitchen & wash basin upto 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings complete all as directed.
M & L removing chokes in drains of WC/bath room/kitchen & wash basin other than ground floor complete all as directed.
Excavation in trenches not exec 1.5m wide and not exec 1.5m in depth for foundation etc or for shaft well, manhole, Sewage line etc not exec 10 sqm on plan and not exec 1.5m depth and getting out to soft/loose soil complete all as specified
All as per item No-11 above but depth exec 1.5m and n exec 3m
Demolition and breaking up drain pipes 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar.
All as per item No - 13 above but 200mm dia
S&f 150mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars
All as per item No - 15 above but 200mm bore.
M&l Concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C-2 complete all as specified
All as per item No - 17 above but 200mm dia drain pipes
Demolition of brick work/block masonry built in cement mortar.
M&l for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
Extra for forming fair finishing drain or channels 60 cm inner girth in cement concrete using extra cement including forms, moulds stopped ends etc.all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in CM 1:4 complete as directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L 15mm thick rendering in cm (1:4) and making surface even and smooth without using extra cement all as specified and directed.
M&L providing cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in coping, benching complete all as specified.
M&L TMT bars 8mm dia and over, cut to length bent to shape required including cranking, bending spirally for hoping for cover slabs , hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia quality all as specified and directed.
Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips.
Demolition of reinforced cement concrete as in drain/manhole cover slabs not exc 150mm thick.
M&L providing precast cement concrete for manhole cover slabs and similar work type B-1 (1:2:4) using 20mm graded aggregate set in cement mortar (1:4) all as specified.
Returning , filling in including spreading , levelling, watering and well ramming in layers not exec 25cm of soft/loose soil complete all as specified
Removing of excavated material/broken RCC pipe etc excedding 100 m and depositing where directed at a level not exec 1.5 m above the ground level.
Dismantling 100mm dia cast iron pipes or reinforced concrete drain pipes ,jointed in cement mortar fixed on walls including all fittings such as bands straps etc complete.
Dismantling 75mm dia cast iron pipes or reinforced concrete drain pipes ,jointed in cement mortar fixed on walls including all fittings such as bands straps etc complete.
S&F 100mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with lead joints, fixed to walls complete all as specified.
S&F 75mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with lead joints, fixed to walls complete all as specified.
Taking down PVC (SWR) pipes (any size or pattern), including all fittings.
S & F 110mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls/ laid in floors all as specified and directed.”
S & F 75mm bore PVC (SWR) pipes single socketed in any length with Stainless Steel step clamps of suitable size with nuts and bolts etc. as per the requirement at site and fixed to walls / laid in floors all as specified and directed.
S&F cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door suitable for 100mm bore CI pipes jointed with lead joint complete all as specified.
S&F cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door suitable for 75mm bore CI pipes jointed with lead joint complete all as specified.
S&F cast iron branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches with oval access door suitable for 100mm bore CI pipes jointed with lead joint complete all as specified.
S&F cast iron branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches with oval access door suitable for 75mm bore CI pipes jointed with lead joint complete all as specified.
S&F 75mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified.
S&F 110mm bore PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified.
S&F 75mm bore PVC (SWR) bends any radius complete all as specified.
S&F 110mm bore PVC (SWR) bends any radius complete all as specified.
S&F 75mm bore PVC (SWR) vent cowl complete all as aspecifed.
All as per item No- 47 above 110mm bore pipe
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: conforming to Fe-290 Gde-E-165 complete all as specified
Demolition of cement concrete unreinforced in ground floors and pavings n.exc 15 cm thickness (below or above ground level) & depositing at a place directed by Engr-in-Charge.
M&l for precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with using grey cement & pigment laid over and inluding 50mm thick 6.3mm graded stone chippings cushioning complete all as specified and directed.
M&L cement concrete type D-2 (1:4:8) using 40mm graded aggregate as in foundations filling and mass concrete
M&L for Hard core of gauge n exc 63mm, deposited, spread and levelled in layers nexc 15cm thick, watered and rammed to a true surface complete all as specified and directed
M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) in plinth protection, finished even and smooth w/o using extra cement complete all as specified and directed..
M&L chequered cement concrete tiles 20cm x 20cm x 25mm thick with white cement and pigments, set, jointed and pointed in neat cement slurry in floors including 20mm thick screed bed or bedding in CM 1:4 for laying floor finishes complete all as specified.
M&L for preparing newly plastered surfaces of wall & applying a coat of acrylic primer & two coats of antifungal exterior emulsion paint complete as specified and directed upto any height.
Dismantling posts or struts from natural ground (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground
Dismantling fencing wire mesh, any type.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance exc 100 m and making good surface in soft & loose soil complete all as specified and directed
S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting,welding etc., and similar work conforming to Fe- 290 Gde E-165
M&l for cement concrete 1:3:6, type C2 using 40mm graded stone aggregate as in foundations, filling, post holes and mass concrete
S&F of MS screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with two washers and one hexagonal or square nut n exc 5cm long having dia of neck exc 15mm.
S&F Mild Steel Flats 40 x 6 mm thick in wind ties for roof inclduding securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc conforming to Fe-290 Gde E-165.
Supply only chain link MS galvanisd fencing, of mesh 50 x 50mm minimum dia of wire 4.00mm complete all as specified all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails, straining bolts, etc, including provision of binding wire.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over red oxide or zinc chrome primer all as specified and as directed.
Vackachan Constructions
PS James
AB CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .