Tender Value
₹96.2 L
EMD Value
₹1.7 L
Closing Date
24 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
REPAIR AND MAINT OF BUS BAR TRUNKING SYSTEM AND ALLIED WORKS UNDER AGE EM-II OF GE DEHRADUN
2021_MES_497701_2
9661/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
GE Dehradun
₹1.7 L
Yes
19 Mar 2022
4 Feb 2022
26 Feb 2022
4 Feb 2022
24 Feb 2022
11 Feb 2022
60 days
Amount
M & L for replacement of burnt bus bar trucking system at LT Panel room at MH Dehradun with the following accessories complete all as specified and directed. (a) End connection interfaces TPN 1000A for connection of LT Panel of bus bar to be supplied for both feeder and receiving end of bus bars mono block to be supplied. - 02 Nos (b) Compact type bus bar trucking system suitable for 1000A, 415V, 50 Hz, TPN as per IEC 61439-6, reference temperature 40 degree centigrade, protection degree IP 55, thickness 1.5mm, No of conductor 3,4 or 5, painted RAL 7035, Halogen free. The insulation between bars is ensured by a double sheath made with polyester film class B (130oC), class F (155oC) thermal resistance available on request. all plastic components have a V1 self-extinguishing degree (as per UL94). They are fire retardant and comply with the glow-wire test according to standards. - 9 RM (c) Elbow vertical 1000A - 02 Nos (d) Elbow Horizontal 1000A - 02 Nos (e) The quoted rates include all the items which are essential for installation of bus bar i.e. threaded roof for hanging of BBT, support etc
M&L for servicing of indoor LT Panels/AMF/APFC Panel installed at LT Plant Room at MH Dehradun including the followings complete all as specified and directed. (a) Main LT Panel (b) Sub LT Panel (c) 1600A AMF Panel (d) 2000A AMF Panel (e) 500 KVR APFC Panel (f) 300 KVR APFC Panel.
Note for item No 2 & 3 :- (a) Operation of panels to be checked as per schematic diagram in Auto/Manual mode & Programming/operation of ACB to be checked. (b) Operation of Fan/Thermostate to be checked.(c) Dismantling cleaning and assembling of front Rear Door cover , push button, locking device, pullout system, racking mechanism chassis and function position indicators. (d) Dismantling, cleaning & Testing in LT Panel. (n) APFC Relay T+E71esting both Capacitor Panel.(o) Dismantling, cleaning and tightening of e, greasing testing and tightening of every point of Auxiliary and control unit connection Block, assembling of Tripping Coil/ Closing Coil, assembling of electrical Spring Charging Motor if required, all Part Cleaning of ACB with CRC Spray all Chamber of LT Panel.(e) Electrical & Mechanical Interlocking Checking and Tightness all Nut-Bolt of all Bus Bar Fish Plate, LT Panel and Capacitor Panel, Transformer Isolator Panel with ACB, DG Isolator Panel. (f) Setting of release as per the load. (g) Checking the healthiness of CTs. (h) Tripping Testing of ACB release for O/L, S/C and E/F by primary injection testing Kit. (j) Programming/ operation of MCCBs to be checked. (k) Proper cleaning of electrical contacts to be checked (l) Tightness for all electrical connections (Wires) to be checked (m) All Meter programing very point of Power Cable in LT Panel.(p) Dismantling, cleaning and tightening of every point of Power Cable in Capacitor Panel. (q) Dismantling, cleaning and tightening of every point of Power Cable in Transformer Isolator Panel. (r) Dismantling, cleaning and tightening of every point of Power Cable in DG Isolator Panel. (s) The servicing should be carried out with authorized dealer of manufacturer OEM of existing switch gear and a certificate should obtained from the service provider duly mentioned the above works has carried out and guarantee period should be quoted.
Supply, laying in replacement and testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 16 Sqmm 4 core complete all as specified and directed.
All as per item No 4 here-in-above but cable of size 10 Sqmm 4 core
Excavation in trenches soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out excavated soil/sand/unserviceable LT Cable for laying of cable and getting out complete all as specified and directed.
Sand cushioning and covering of UG cable using crushed metal sand in trenches for cable protection all as specified
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm in hard /loose soil complete all as specified and directed.
Removing excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for brick well burnt Class ‘B’ as cover to U/G cable laid dry flat over the cable with width equal to length of the cable and abutting each other with gap between adjacent slab not exceeding 10mm over under ground cable for cable protection in trenches all as specified and directed by Engineer-in-Charge.
Cutting existing road/hardstand of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
M&L for GI tubing 40mm dia, medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc complete all as specified and directed.
All as per item No 12 here in above but GI pipe of size 50mm dia
Taking down existing street light/flood light/high mast light carefully (any capacity, any type) from pole carrying out repair work at site including replacement of unserviceable/defective screw, nut and bolts, spares etc, re fixing the fittings in its original position, testing and commissioning, including removal of bushes, creepers and trimming of branches around the light fitting including taking out and re-fixing site complete all as specified and directed. Note: (i) If any major spare is required to replace, the same shall be replaced under respective item of sch 'A' (ii) Tools, ladder, vehicle required to carry out the work shall be provided by the contractor. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provide skilled ITI Electrician and produce the Certificate before the commencement of work. (v) Contractor shall ensure all the street lights are functional before leaving the station and rep of contractor shall take recess after all the street lights are switch ON after rendering completion to respective JEs/Engr-in Charge as day to day basis .
S&F in replacement Street light TIMER control panel, 110 Amps, 3 pole/230Volt, DIGITAL time switch pole/wall mounting made out of 3.15 mm CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements complete all as specified and directed.
M&L PVC insulated copper conductor 3 core 1.5 sqmm cable to be drawn inside the pole, including taking down of old unserviceable copper conductor one, complete all as specified and directed.
S&F junction box made of glass fiber reinforced and transparent poly carbonate of size 126x228x111mm, KV PC 8104 with IP 65 protection including MCB SP, 6 Amps 1 No and suitable size clamps fixing for pole/in PCC foundation etc, including taking down the old unserviceable junction box complete all as specified and directed.
S&F, GI brackets for street light fitting made out of 40 mm dia,1.5 m long, medium grade pipe, bend to 120 degree angle shape, drilled holes etc & fixed with clamps, nuts, bolts complete all as specified and directed.
M&L, for dismantling of old tubular poles duly removing all connection , dismantling PCC platform and taken out from the site and deposited to MES store yard complete all as specified and directed.
M&L for shifting of tubular pole carefully from the existing foundation without any damage, including two coats of black bituminous paint internally through out and externally for embedded and two coats of red oxide primer on exposed surface and relocate/install, including PCC foundation complete all as specified and directed.
S&F LED based Street light, housing made up of Pressure Die Cast Housing LM 6 Alloy/ Anti Dust Exposed Lens, sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of greater than 120 lumen/Watt and a minimum system lumen output of 8400 lumens and maximum system wattage of 70 Watts. The fixture shall have a CRI of minimum 70.
The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=08.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=4KV, PF >0.9 , and SDCM<5. The driver should be BIS approved, fully potted and encapsulated with 440V Stress Voltage protection for 8 Hrs. High Cut off : 325V(+/- 15V) and Auto Restart function should also be available within the fixture. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to Philips CAT No. - BRP062 LED84 CW PSU or equivalent, required to fix with existing bracket of min 40 mm dia complete with complete all as specified and directed. including taking down existing fitting complete. Note:- Test certificate shall be submitted by the contractor.
All as per item No 21 here-in- above but street light, efficacy of greater than 110 lumen/Watt, lumen output of 5900 lumens and of 60 Watts.
M&L for shifting of poles of post top lantern carefully from the existing foundation without any damage, and relocate/ install, including PCC foundation complete all as specified and directed.
M&L for shifting of Bollard light, by removing carefully from existing PCC foundation, and install at new places, including PCC foundation, nuts, bolts & washers complete all as specified and directed.
S&F fully cast aluminium body finished with polyurethane paint (with prior treatment) bollard of length 647 mm & circular base diameter of 139 mm and max diameter of leg of bollard 76mm surrounding with fully cast aluminium body finished with PU paint with frosted acrylic window cover. Total length of fitting 514 mm and max breadth of fitting is 247 mm with B22 brass holder provided with aluminium cover suitable for 12 to 18 Watt LED bulb including PCC foundation, nuts, bolts & washers complete all as specified and direted. Total length of bollard fitting with fitting 1162mm with as per IS 10322 part-5 section-1 latest 2017..
S&F post top lantern with fully cast aluminium extra heavy pole with surmounted with B22 brass holder provided with aluminium cover designer leg and broader designer base finished with polyurethane paint (with prior treatments) including PCC foundation, nuts, bolts & washers complete all as specified and directed. Dimensions are as under:- (a) Diameter of one leg is approx 88mm. (b) Outerdia for spigot entry is 75mm-03 Nos (c) Total length of the pole incl base and legs is 3000mm. (d) Total length of pole with fixture is 3585mm. As per IS 10322 part-5 section-1 latest 2017.
S&F in repair flood light fittings. 180 Watt Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP66 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces as 180 watt or higher size LED, glass cover complete all as specified and directed.
S&F LED flood light fittings die-cast aluminium housing 60 watt along with angle iron bracket and fixing accessories like nut, bolt, washers and clamps etc complete all as specified and directed.
S&F flood light fitting 50 Watt . RGB colour Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing IP66 flood light with high power LED's as light sources, suitable for high lighting architectural features or retail spaces, Glass cover, complete all as specified and directed. Note:- Test certificate shall be submitted by the contractor.
S&F Octagonal poles (6 Mtrs long) made out of hot dipped galvanized iron ASTM A123 with minimum average GI coating of 65μm which shall be tapered towards top with base plate continuously welded to pole, finial toper plug, J bolt, nuts and washers all as specified including earth work and foundation for fixing only LED Solar light fittings 24/30 watts complete all as specified and directed. Note: Solar Light fittings shall be issued under sch 'B’
M & L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of poles and stay etc including form work complete all as specified and directed.
M & L for PCC 1:3;6 type C-1 (using 20 mm crushed stone aggregate) as in coping of poles etc including form work complete all as specified.
S&F LED foundation Light 12 Watt Ground Burial Compact and robust design with die cast aluminum housing and stainless trim, IP68 water proof connectors along with its fixing accessories complete all as specified and directed.
S&F, in repair Power contactor, three pole, 80 Amp, MNX type, complete all as specified and directed.
All as per item No 34 her-in-above but , 50 Amp,
S&F LED Street light driver 45 Watt, complete all as specified and directed.
All as per item No 36 her-in-above but driver 75 Watt,
All as per item No 36 her-in-above but driver 100 Watt
S&F, in repair Timer switch digital type 1P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A, with 1 change over (1 CO), complete all as specified and directed.
Supply, fixing, connecting and testing of Screen display controller of 3 phase 440 Volt, 50 Hz 750 KVA DG Set as per site requirement complete with OEM at Military Hospital Dehradun complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of L.T Panel, thermoplastic Polycarbonate IP 65 Distribution Board in accordance with IEC 60 529 (Dust Proof, Water Proof & Weatherproof) Thermoplastic Polycarbonate DB of Shock proof, Rust Proof, Corrosion Free, Acid & Chemical Resistant, Fire Retardant & Self Extinguishing, UV Resistant, Silica and Halogen Free recyclable material. Type tasted as per IEC 61 439-1. Total Insulated with System Voltage 415V AC, 50Hz, and 5 wires. The board/panel should be UV resistance in accordance with IEC 61439-1, clause 10.2.4:The panel should be anti-acid & anti corrosive. Degree of protection against mechanical load should be IK08 ( 5 Joule) in accordance with IEC 62262.Outdoor Floor mounting
Incomer:-
-200 Amps 4P, 25 KA MCCB- 01 Nos.
- Multifunction Meter-01 Nos.
- RYB Indication Lamp -01 Nos.
Outgoing:-
- 100 Amp FP,25 KA MCCB- 02 Nos.
- 63 Amp FP,16 KA MCCB- 02 Nos.
All as per item No 41 here-in above but with the following switch gears
Incomer-
- 320 Amps 4P, 36 KA MCCB- 01 Nos.
- Multifunction Meter-01 Nos.
-RYB Indication Lamp -01 Nos.
Outgoing-
- 250 Amp FP,25 KA MCCB- 01 Nos.
- 160 Amp FP,25 KA MCCB- 02 Nos.
- 63 Amp FP,16 KA MCCB- 01 Nos.
All as per item No 41 here-in above but with the following switch gears .
Incomer -
400 Amps 4P, 50 KA MCCB- 01 Nos.
Multifunction Meter-01 Nos.
RYB Indication Lamp -01 Nos.
Outgoing-
250 Amp FP,36 KA MCCB- 01 Nos.
160 Amp FP,25 KA MCCB- 02 Nos.
125 Amp FP,25 KA MCCB- 01 Nos.
63 Amp FP,16 KA MCCB- 01 Nos
All as per item No 41 here-in above but with the following switch gears
Incomer-
- 500 Amps 4P, 50 KA MCCB- 01 Nos.
- Multifunction Meter-01 Nos.
- RYB Indication Lamp -01 Nos.
Outgoing-
- 250 Amp FP, 36 KA MCCB- 02 Nos.
- 160 Amp FP, 25 KA MCCB- 03 Nos.
All as per item No 41 here-in above but with the following switch gears
Incomer:-
- 630 Amps 4P, 50 KA MCCB- 01 Nos.
- Multifunction Meter-01 Nos.
-RYB Indication Lamp -01 Nos.
Outgoing-
- 250 Amp FP,36 KA MCCB- 03 Nos.
- 160 Amp FP,25 KA MCCB- 02 Nos.
- 125 Amp FP,25 KA MCCB- 01 Nos.
All as per item No 41 here-in above but with the following switch gears
Incomer :–
250A 4P On load Change over switch - 2 Nos
MCCB – 1No 250A 4P MCCB – 1Nos
RYB indication lamps – 1Set
Digital type multifunction meter – 1Set Copper Bus bar rated for 400A
Outgoings.
100 A 4P MCCBs – 3 Nos
63 A 4P MCCBs – 1 Nos
TIMER control panel, Timelite-63A 3Pole/230V-Digital Time Switch - 1 Nos
3 Phase KWH Meter measure up to 250 Amp - 1 Nos
Shifting of LT Panel/Bus Bar Chamber/Feeder Pillar from the foundation duly disconnecting existing incoming/out going connection carefully (any capacity ,any type) and re-installed where ever directed necessary connection and PCC foundation and earth work etc complete all as specified and directed.
Taking down/dismantling LT Panel/Bus Bar Chamber/Feeder Pillar from the foundation duly dis connecting existing incoming/out going connection carefully (any capacity, any type) for carryout complete all as specified and directed.
M&L for fabricating stand of angle iron 50x50 x6mm of height 50 cm, welded with existing panel complete all as specified and directed.
M&L for fabricating MS CRCA sheet of 3mm thick, the inner shell duly compartmented for each control gear, including Powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements welded with existing panel complete all as specified and directed.
M&L for fabricating and fixing alluminium bus bars of existing gauge/size and duly fixed with existing incoming /outgoing connections complete all as specified and directed.
S&F Cable glands of existing gauge/size and duly fixed with existing incoming/outgoing connections complete all as specified and directed.
M&L for painting of LT Panel/Bus Bar Chamber/Feeder Pillar box of any type & size, removing old paint with emery paper/wire brush, fill the cavities with metallic putty and made smooth surface, apply one coat of metallic primer and and applying one coat of alluminium paint over the metallic painted surface complete all as specified and directed.
S & F, in replacement MCCB 4Pole, 400 Amps, 36 KA, 415 V, with adjustable thermal & adjustable magnetic setting Ics=100% Icu complete all as specified and directed.
All as per item No 54 here in above but MCCB 4Pole, 320 Amps, 36 KA, 415 V.
All as per item No 54 here in above but, 250 Amps, 36 KA, 415 V.,
All as per item No 54 here in above but MCCB 4Pole, 200 Amps, 25 KA, 415 V.
All as per item No 54 here in above but MCCB 4Pole, 160 Amps, 25 KA, 415 V.
All as per item No 54 here in above but MCCB 4 Pole, 125 Amps, 25 KA, 415 V.
All as per item No 54 here in above but MCCB 4 Pole, 100 Amps, 25 KA, 415 V.
All as per item No 54 here in above but MCCB 4Pole, 63 Amps, 25 KA, 415 V.
M&L for repair high mast light motors of 1/2HP along with starter and wiring complete all as specified and directed.
Supply, Installation, commissioning and testing of LED based ceiling suspended double dome Operation Theatre(OT) light with provision only for suspended Camera to be fitted inside the dome as and when required at later stage in compliance with medical device electric standard IEC-60601 2-41, with each dome consisting of minimum 30 LED's and maximum 120 LED's housed in dome with diameter ranging between 500 mm to 700mm, suspended through a ceiling assembly with spring arm system to provide precise positioning of the OT light as required during surgery complete with UPS including sealed Maintenance free batteries to provide instantaneous backup in case of power failure for 30 minutes complete with all necessary wiring for hanging arrangements as per manufacturers guidelines with following specifications.
MAIN DOME SATELLITE DOME Intensity @ 1 meter distance (Lux) : 160000 + 10% 160000 + 10% Adjustable Field diameter (cm) : 14-38 14-38 Depth. of illumination L1+L2(cm) : >100 >100 Color Rendering Index (CRI) (Ra) : 95+3% 95+3% Color temperature (K) : 4500 + 10% 4500 + 10% Intensity control (%) : 25-100 25-100 Control : Dual control Manual and Remote Dual control Manual and Remote Type of field - focusing control : By sterilize able handle By sterilize able handle Type of Intensity control : By control panel on lamp head By control panel on lamp head ELECTRICAL AND MECHANICAL SPECIFICATIONS MAIN DOME SATELLITE DOME Power supply input voltage V 220-230 V 220-230 V Power consumption < 150 watts W < 150 watts W Frequency Htz 50/60 50/60 Dome Diameter 500mm- 700mm 500mm- 700mm LED service life Hrs 4500 + 10% 4500 + 10%
Supply installation testing and commissioning of integrated call bell station for 20 beds with the following accessories :-
Surface mounting box 1 module.
Modular plate of 01 Module.
6 Amp bell push of 1 Module.
Call register 1 Module.
Lables for call register 1 to 20.
Buzzer 1 Module.
24 module plate with metal frame.
Red indicator light 2 Module.
Surface mounting box 24 module.
S&F Water heater storage type electric driven, single phase of capacity 25 litre complete with fixing arrangement including grouting of nut bolt, washers 4 nos hold fasteners etc all as specified and directed. Old unserviceable water heater will be deposited to MES store yard)
S&F LED Bay Light 80 Watt on roof along with its fixing accessories complete all as specified and directed.
S&F in repair MCB SP, 6 to 32 Amp ,"C" curve, 240/415 volt AC, as per IS/IEC 60898 complete all as specified and directed.
Comprehensive/preventive maintenance of RO+UV purifier of 20 Ltrs/Hr by carrying out periodically maintenance of RO make - havells including cleaning of filters, tightening electrical connections, repair/change of UNSV parts such as sendimatin cartridge, silver impregnated taste enhancer, minerals cartridges, diaphram booster pump RO membrane SV Kit etc ensure serviceability throughout maintenance period complete and attending complaints all as specified and directed.
S&F surface mounting type LED "EXIT" light with multi LED which provides illumination on normal mains power supply and the same lamp continuous to provide illumination to during mains failure on self contained battery source ON consumption of mains supply, the lamp switches back to the mains automatically and simultaneously starts recharging the battery to the required level maintained models provided uninterrupted illumination complete all as specified and directed.
S&F Sequence Controller LMO 24 for boiler 60 Kgs/Hr as per OEM (Thermax Limited Model No RXA06/LH/DOM)) recommendation at Laundry Plant at MH DDN all as specified and directed.
S&F Photo Cell for boiler 60 Kgs/Hr as per OEM (Thermax Limited Model No RXA06/LH/DOM)) recommendation at Laundry Plant at MH DDN complete all as specified and directed.
S&F Hose Pipe 3/8 " x 40 Mtr as per OEM (Thermax Limited Model No RXA06/LH/DOM)) complete all as specified and directed.
S&F Hose Pipe 1" x 1.2 Mtr for boiler 60 Kgs/Hr as per OEM (Thermax Limited Model No RXA06/LH/DOM)) recommendation at Laundry Plant at MH DDN complete all as specified and directed.
S&F Electrode for boiler 60 Kgs/Hr as per OEM (Thermax Limited Model No RXA06/LH/DOM)) recommendation at Laundry Plant at MH DDN complete all as specified and directed.
S&F Electrode cap for boiler 60 Kgs/Hr as per OEM (Thermax Limited Model No RXA06/LH/DOM)) recommendation at Laundry Plant at MH DDN complete all as specified and directed.
Supply only following chemicals for regular use for boilers :-
Maxtreat 3006(HSN-38249900)
Economix (HSN-28429090) Per Bottle 1.4 Kg
Supply only chemicals (MAXCLEAN 05 (HSN-38249900) for cleaning purpose for boilers
M/s Kamal Traders
Supra Electrical
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .