Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹76.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹76.5 L+₹1,013.77 (0.01%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹76.5 L+₹1,742.48 (0.02%)Rejected-AOC C O LT MAAHANTA NARZARY W NO 5 TENGAPARA P O P S KOKRAJHAR DIST KOKRAJHAR BTC ASSAM PIN 783370 | KOKRAJHAR | KOKRAJHAR | ASSAM | 783370 | L3 | Rejected-AOC L3 |
Tender Value
₹76.5 L
EMD Value
₹1.5 L
Closing Date
7 Mar 2022, 3:00 pmClosed
The S.E, PWD, Kokrajhar, Bldg, Circle
O/o the S.E, PWD, Kokrajhar, Bldg, Circle, Kokrajhar
Construction of EAC Qtr. 2 Nos. including brick boundary wall, brick drain, RCC staging and garage etc. at Gossaigaon SDO (Civil) residential Complex, Gossaigaon in Kokrajhar District. Package No.504_1
2022_BoTC_24465_1
TECH- 05/SE(B)/E-Tender/2021-22/20
Open Tender
Civil Works - Building
Item Rate
180 days
Gossaigaon
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,300
The Principal Secretary, BTC, Kokrajhar
₹1.5 L
Yes
24 Mar 2022
23 Feb 2022
7 Mar 2022
23 Feb 2022
7 Mar 2022
23 Feb 2022
23 Feb 2022 - 7 Mar 2022
Amount
(A) Construction of EAC Quarter 2 (Two) Nos.: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal Steel/Shyam Steel/RINL (c) ISI approved Mild steel reinforcement bar (MS Bar)
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1. Columns, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate..... and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or prop.1:1.5:3
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate..... and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Super-Structure from plinth level upto 1st floor level i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. b) M20 grade concrete or prop.1:1.5:3
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary. (b) In proportion 1:5
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing and laying 25mm thick damp proof coarse with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc.complete as directed.
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S. Rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proportion 1:5
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrough, framed and fixed in position in contact with C.C or brick masonary wall including supplying fitting and fixing with M.S hold fast (40mm x 3mm x 250mm) as per design embedded in cement concrete block in proporation 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonary as directed and specified. a) With sal wood.
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (roof trusses and purlin etc. to be measured and paid separately) (b) 0.50mm thick
Providing galvd iron riding of TATA shaktee/SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed. (b) 0.50mm thick. (ii) 230mm lapping
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceilling which includes G.I perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceilling.... and two coats of drywall topcoat suitable for Gypboard complete aty all levels as specified and directed. (For light providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported to be measured and paid separately where necessary). ii) 9.5mm thick.
Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/opening with M.S flats at required spacing in frame all round, squre or round M.S bars with round headed bolts and nuts or screws. 1. Plain Grill (c) Fixed to Brickwork/P.C.C/R.C.C
Providing fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens.2.5mm to 3.5mm uniformaly thick cross bands, style & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hings,screws,bolts etc as specified and directed at all levels (Door fixtures and fittings to be measured ann paid seperately) (c) 40mm thick
Providing fitting and fixing anodised alluminium sliding windows and ventilators of standared sections of approved brand without horizantqal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangments, screws etc as required complete as specified and directed for all levels.. (a) 2 Track sliding bindow. (i) 6mm clear glass.
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On fair side (b) In cement mortar 1:4
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. (b) Using other ISI marked approved brand tube
Providing vitrified floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop 1:3 (1cement:3coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/ Sika/ Pedelite/ Rouf)/ White cement slurry mixed with approved pigment to match shade of tiles mixed with approved pigment to match the shade of the tiled,complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (a) Normal range (Somany/Orient/Nitco/Varmora/VITA/Marbito/Make) ii) Of size 600mmx600mm and above
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC (i) Normal range (Sizes 300 mm x 300mm and above) (a) Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.(Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). a) Normal range (Somany/ Orient/Nitco/Asian Make) i) Of size 200mmx300mm and above
Cement plaster skirting with cement mortar in prop. 1:3 ( cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (b) 20mm thick
Plain cement concrete floors base in prop 1:3:6 laid in alternate bays as specified with coarse agg.of size 13mm to 32mm including dewatering if necessary, and curing etc complete. (b) 50mm thick
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. i) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast R.C.C slab over drain, septic tank etc. in prop 1:2:4 reinforced with 10mm MS bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curring etc. complete including fixing in position as directed. b) 75mm thick slab
Providing barge board of size 200mm x 20mm with 1st class local Hollock/Bonsum timber including fitting and fixing with necessary wood screws etc complete.
Finishing old/new wall with water proofing weather coat smooth anti-fungal premium texterior exterior finish of sandex matt brand of snowcap india. LTD. of required shade aftere cleaning the surface etc. including scaffolding complete as directed at all levels (two coats)
f) Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
Applying priming coat over new wood and wood based surfaces over l00mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter, sand papering and knotting. (b). With ready mixed paint, wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian pain/ Berger pain/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of a1l dirt, dust and other foreign matter sand papering and stopping. (i) Surfaces over l00mm in width or girth. b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over l00m in width or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over l00mm in width or girth. b) High, gloss (Asian pain/ Berger paint/ICI paint/ J & N paint/ Nerolac)'
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction ofthe Department complete. a) with aqueous emulsion having concentration 1: 19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1 : l9 with chloropirophose solution (tricel or euivalent) and water, i.e. l% solution.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati City
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural mart & satin frrished) a) Sliding door bolts i) 300mm x 16mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural mart & satin frrished) b) Tower bolts ii) 250mmx 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural mart & satin frrished) c) Door handles ii) 100mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural mart & satin frrished) d) Gate shutter hook & eye iii) 150mm
Sanitary works: Vitreous water closet squatting pan (Indian type W.C. Orissa Pattem) of size 530 x 410 mm (a) White (a) Hindware make
Providing vitreous china wash basin with CI/MS brackets C.P. brass chain with plug, PVC waste pipe including painting of fittings and brackets cutting and making good the walls wherever required. (Pillar cock stop cocks waste coupling are to be paid separately). 1.13.2 Basin (Without pedestal) (A) Parryware make (a) White. (i) Star Basin 550 x 400 (Cat No.C0450)
Supplying fitting and fixing P.V.C Flushing cistern with all intemal fitting with CI brackets including fitting and fixing standard size CP flush pipe union clamps etc. complete as directed and specified (piles will be measured separately). (I) Parryware make. (a) White. (ii) Deluxe
Supplying, fitting and fixing PVC pipes of 6kglcm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directe and specified. (a) In exposed surfaced of in trenches. (ii) 1l0 mm dia
Supplying, fitting and fixing PVC pipes of 6kglcm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directe and specified. (a) In exposed surfaced of in trenches. (v) 63 mm dia
Supplying fitting and fixing 87.5 degree PVC of (Supreme/Prince) of other ISI approved including joining fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (a) In exposed surface or in trenches. (ii) 110mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 kg weight complete as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Labour for boring hole for inserting tube well pipes through Different soil/ rock media including hire charges of drill pipes, scaffolding tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Departrnent. (ii) Bore hole of l00mm diameter.
Supplying fitting fixing pipes plain/bevel ended for casing conforming to relevant I.S. code of practice including supplying and fitting of the well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (I) G.I.Pipe a) TATA/ SAIL (Medium) socket should be welded to the pipe (iv) 80 mm diameter
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complete as directed. (i) Maya popular.-6
Supplying fitting fixing pipes plain/bevel ended for casing conforming to relevant I.S. code of practice including supplying and fitting of the well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (i) G.I. Pipe a) TATA/ SAIL (Medium) socket should be welded to the pipe (i) 50 mm diameter
Supplying fitting fixing pipes plain/bevel ended for casing conforming to relevant I.S. code of practice including supplying and fitting of the well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. (II) PVC Pipe (Supreme/Prince/Fusion/SFMC Brand) (i) 50 mm diameter
Supplying fitting and fixing G.I. filter 2.00 metre long.
Supplying fitting fixing approved uPVC pipes of different sizes------etc. complete at all levels including below g.l.as directed and specified. A) In Exposed Surfaces or in trenches d) 25 mm
Supplying fitting fixing approved uPVC pipes of different sizes------etc. complete at all levels including below g.l.as directed and specified. A) In Exposed Surfaces or in trenches f) 15 mm
Supplying fitting and f,rxing C.P. bib cock 15mm dia of approved brand directed and specified (G.L & C.P. pipes will be measured specified). (I) Essco make (Delux/Sumthing spl/Tropical) (A) Bib cock Short body.
Supplying fitting and fixing chrome plated CP stop-cock of approved brand--- (i) Jaguar (a) 15 mm dia
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (I) Sona make (b) Heavy type.
Supplying, fitting, and fixing overhead adjustable Chrome plated (C'P.) spray shower 15mm dia of Sona make with wall flange as directed and specified. (pipes will be measured and paid separately) (a) Supreme shower with arm
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the staging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (D 1000 Lt. Capacity. (a) Sintex make.
Supplying and fitting gun metal country pit valve (Full way valve) I.S.I. Make as specified and directed. (e) 15 mm dia
Electrification for 2 Nos EAC Qtrs.: 1.1 :- Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C insulated singal core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR kabel or Equivalent make as approved by the Deptt. with flat l9 mm ISI market casing'n' capping (AKG precision/presto plast/polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type swith/bell push (Anchor penta/Gold medal / Kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet kany. Kom / Havells or equivalent make as approved by the Deptt.) etc. Complete as directed and specified by the Deptt. 1.1.1 Short point up to 3.00 mehe. Length
1.1 :- Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C insulated singal core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR kabel or Equivalent make as approved by the Deptt. with flat l9 mm ISI market casing'n' capping (AKG precision/presto plast/polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type swith/bell push (Anchor penta/Gold medal / Kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet kany. Kom / Havells or equivalent make as approved by the Deptt.) etc. Complete as directed and specified by the Deptt. 1.1.2 Medium point up to 6.00 metre. Length.
1.1 :- Wiring for light/ fan/ call bell point with 2x1.5 sq mm P.V.C insulated singal core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/ RR kabel or Equivalent make as approved by the Deptt. with flat l9 mm ISI market casing'n' capping (AKG precision/presto plast/polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type swith/bell push (Anchor penta/Gold medal / Kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet kany. Kom / Havells or equivalent make as approved by the Deptt.) etc. Complete as directed and specified by the Deptt. 1.13 Long point up to 10.00 mete. length
1.2 :- Wiring to 5 a pin 6Amps plug paint with 1.5 Sq. Mm P.V.C insulated single care unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade upto 11000 volts (Finolex/RR Kabel or Equivalent make as approved by the Deptt.) 1.2.2 Medium paint up to 6.00 metre. Length.
1.3 :- Wiring for 5/6 pin l6 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible brigh annealed electrolytic copper conductor for voltage grade up to 1 100 volts (Finolex/RR Kabel or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing ,n, capping (AKG/ precision presto plast/polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type swith (Anchor penta/ Gold medel/ kolor kany. Kom/Havells or equivalent make as approved by the Deptt.) GI/MS switch board (I.S.I. marked) with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete. 1.3.2 Medium point up to 6.00 metre. Length
1.11 Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C insulated single core unsheathes industrial (Multistrand) cble FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or equivalent make as approved by the Deptt.) including providing & fixing 5 pin 6 amp socket outlet (Anchor penta /Gold medal / Kolor kany. Kom/havells or equivalent make as approved by the Deptt.) and 6 amp flush switch.....of and fan.
2.7 :- Wiring for drawing sub- main line with P.V.C. insulated single core unsheathed industrial (Multistand) cable FR conforming to IS-694: 1990 with flexible bright annealed electolytic copper conductor for voltage grade up to I100 volts ( Finolex / RR kabel or Equivalent Make as approved by the Deptt.) PVC conduit. 2.7.1 with with 2 x 2.5 sq. Mm. + earth continuity 1 x 1.5 sq. Mm. In 20 mm. Dia.2mm thick/ heavy rigid PVC IS: 9537 part - III conduit.
2.7 :- Wiring for drawing sub- main line with P.V.C. insulated single core unsheathed industrial ( Multistand) cable FR conforming to 15-694: 1990 with flexible bright annealed electolytic copper conductor for voltage grade up to I100 volts ( Finolex / RR kabel or Equivalent Make as approved by the Deptt.) PVC conduit. 2,7.2 with 2 x 4 sq. Mm. + earth continuity with l x 2.5 sq. mm. cable in 20 mm. Dia. 2mm thick/ heavy rigid PVC IS: 9537 part - Itr conduit
2.7 :- Wiring for drawing sub- main line with P.V.C. insulated single core unsheathed industrial ( Multistand) cable FR conforming to 15-694: 1990 with flexible bright annealed electolytic copper conductor for voltage grade up to I100 volts ( Finolex / RR kabel or Equivalent Make as approved by the Deptt.) PVC conduit. 2.7.3 with 2 x 6 sq. Mm. + earth continuity with lx 4 sq. Mm. Cable in 25 mm. Dia. 2mm thick/ heavy, rigid PVC IS: 9537 part - III conduit.
ll.l2:- Supplying and fixing of polished brass bracket of l8 S.W.G, 25 cm long cast back plate and brass.
11.16 :- Supplying and fixing of bult head fitting suitable for CFL lamp complete with all accessories including connection as approved by the Deptt. as required. (Without lamp)
11.26 Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/ decorative bracked/bulk head fitting/ pendent holder etc. As specified and directed by the deptt.
11.31 :- Supplying and fixing of call bell (Buzzer) including 6 amp capacity button flush type bell push switch including connection as approved by the Deptt. as required.
15.2:- Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. Complete with making necessary connection as approved, specified and directed by the deptt. 15.2.1 (ABB, Schneider MG, lengrand, Hager, Crabtree xpro make) 15.2.12 6 way SPN double door
16.1 :- Supplying with fitting and fixing DP 10 KA 240 /415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.1.1 B series (Schneider mg, legrand, Hager, Crabtree Xpro make) 16.1.1.1 6 to32A
22.7 Supply, installation & testing of G.i earth station with perforated 40 mm dia and 4.50 Metre long heavy duty G.I pipe with necessary 40 mm dia. G.I Fittings such as Soket, Tee, elbow, nipple and 50mm x 40mm G.I reducing socket for funnel including locking arrangement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt.
22.12:- Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance group in location of high soil resistivity as and when required and specified by the deptt.
22.16 Supplying & laying of 8 SWG Copper Earth from Earth Electrode ( below G L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 :- Supplying including fitting and fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the department (without regulator) 27.1.3 premium model 1400 mm Sweep. (ORIENT PSPO make) / premium model 1400 mm Sweep SS-390 Deco.(Havells make)
27.2 :- Supplying including fitting and fxing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connections as approved by the Deptt. As required complete and as directed by the department. 27.2.1 Domestic. 27.2.1.2 Power Flow 225 mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceilling fan regulator including connection etc. complete as required. 27.6.2 Electronic Type.
39.2.2 1.5 HP single Phase jet monoblock two stage pump set G(Crompton Greaves/Aquatic/CRI/V-Guard/Calma make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L & T Siemens make).
39.2.4 1 HP single Phase jet monoblock two stage pump set (Crompton Greaves/ Aquatic/ CRI/V-Guard/ Calma make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L &T / Siemens make).
ECBC.3.28 Supplying, Installation, testing and commissioning of the following LED luminaries complete with all accessones such as driver etc. Directly on wall / ceiling including connection with 1.5 .Sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. ECBC.3.28.1 LED Lamp indoor application, operating voltage 90V - 250V, l2V DC I. Model GNI lJ -2 or equivalent, LED Lamp with mains input (Make Philips/Bajaj/Schneider/Havells)
ADD Annexurel/ Supplying with fitting and fixing of single phase Digital type energy meter load Security Supervision charge Iabour charge etc. including G.I nuts & bolts, socket bend etc as required complete.
(B) Extension of Brick Boundary Wall 44.00 R.M. : Earth work in excavation for foundation trenches of walls, retaining walls. footing of column, steps, and septic tank etc. including refilling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all leaf and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the sub grade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 8 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) TMT corrosion resistant steel (CRS) reinforcement bar.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) c) ISI approved M.S. Rod.
Providing fonn work of l2mm thick plywood Board so as to give a rough finish including centering, shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete aud plain coucrete work in :- 3.2.1.1 Columns, pillars, Posts & struts of squale/rectangular/Polygonal in plan or any shape like Tee/ L etc. having plane vertical face.
Providing fonn work of l2mm thick plywood Board so as to give a rough finish including centering, shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete aud plain coucrete work in :- 3.2.1.2 Sides and soffits of Beam, beam haunchings, catrtilever girders bressumers lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing & laying plain/reinforced cement concrete work cement sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) using mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,r etaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level a) M15 or Prop. 1:2:4
Providing & laying plain/reinforced cement concrete work cement sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) using mixture machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture plasticiser. a) M-15 grade concrete or prop.1:2:4
Brick work in cement morter with 1st class brick including racking out and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded store agg. Stone of 10mm down nominal size including providing approved damp proof admixture in proparation of recommended by the manufacturer including curing etc. complete as directed.
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) i) 112mm thick brick wall. (a) In cement mortar in proporation 1:4
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in curing finished even and smooth including curing complete as directed. (A) On rough side (b) In cement mortar 1:4
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm in curing finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
(Cement paint and primer) (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly brooming the surfaces to remove all dirt and remains of loops powered materials.
Iron Gate, 2 Nos: Earth work in excavation for foundation trenches of walls, retaining walls.footing of colums,steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/quality picked jhama brick, sand packed after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering where necessary shall be measured and paid separately.) (a) In prop 1 cement :4 sand : 8 coarse agg. by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). b) Other ISI approved TMT bars. (SAI/BISCON/THERMAX)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). c) ISI approved M.S. Rod
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M.
Providing & laying plain/reinforcement concrete works in prop 1:2:4 (1cement : 2 coars sand : 4 graded stone aggregated 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) I) Using mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, grade beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level.
Providing & laying plain/reinforcement concrete works in prop 1:2:4 (1cement : 2 coars sand : 4 graded stone aggregated 20mm down) including dewatering if necessary and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) I) Using mixture machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case including preparing the top surface & finishing of nosing.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary and curing complete as directed. (I) In Sub-structure up to plinth level.
15 mm thick Cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm in curing complete as directed. a) In cement mortar 1:4
(a) Clour washing with lime on wall surface (two coats) over and including a priming coat of white washing to givean even shade after thouroughly brooming the surface to remove all dirt, dust mortar drops and other foreign matter.
Supplying fitting double leaf heavy duty iron gate frame made from M.S. flat 50mm x 6mm iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top and 20mm dia M.S bars 200mm apart from bottom flat to middle flat including drilling welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary looking arrangement on both faces, arrangement for temporary closing the gate 2 nos. (minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified.
(C) Brick Campus Drain 163.00 R.M: Earth work in excavation for foundation trenches of walls, retaining walls.footing of colums,steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Brick flat soling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a). In prop. 1 cement: 3 sand : 6 coarse agg. by volume.
230mm thick brick wall in cement mortar with 1st class brick including racking out joints and curing complete as directed in structure. (i) In Sub-Structure upto plinth level including dewatering if necessary (b) In proporation 1:4
Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary and curing etc complete. (c) 100mm thick
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. (a) 15 mm thick
Providing precast RCC slab over drain septic tank etc. in prop 1:2:4 reinforced with 10mm MS bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering, curing etc. complete including fixing in position as directed. b) 75mm thick slab
(D) RCC Stagging, 2 Nos: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc complete. (upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel....... (ii) Super Ductile (SD) TMT reinforcement bars.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1. Columns, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face. (ii) Using 12mm thick ply.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.3. Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
3.2.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.2.1 & 3.2.3 (b)
Providing & laying plain/reinforced cement concrete work cement coarse sand & 20 with 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) using mixture machine (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,r etaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level N) Without using admixture, plasticiser. a) M-15 grade concrete or prop 1:2:4.
Providing & laying plain/reinforced cement concrete work cement coarse sand & 20 with 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) using mixture machine (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture plasticiser. a) M-15 grade concrete or prop.1:2:4
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed . (I) In sub-structure up to plinth level including dewatering if necessary (b) In proportion 1:4
Earth/Sand filling in plinth in layers not more than 150mm thick including necessary, carriage, watering, raming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (b) With river sand obtained by truck carriage loading and unloading and carriage to the site of work.
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S. Rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proportion 1:5
Supplying, fitting and fixing door frame made of M.S. equal angle of size 40mmx40mmx5mm fabricated, welded, mitred and joined as per relevant I.S. Codes including fitting 8 nos. of M.S. hold fast, providing closing/ holding device for 2 nos. tower bolts of door for each side and 1 no. for fitting and fixing Aldrop (for single leaf) to the frame for fixing the door to the frame, applying primer to all steel surfaces fixing the frame to the wall/ R.C.C. members by embedding the hold fast securely in C.C. block of M-15 grade complete at all levels as specified and directed. (Door hinges to be paid as per relevant item of the schedule of rates).
Providing fitting and fixng factory made sasntro flush door shutters having core & core bands fabricated from seasoned 1st class timber, 25mm core battens 2.5mm to 3.5mm ...................measured and paid separately. (a) 35 mm thick.
15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles not exceeding 80 mm girth and finished even and smooth including curing complete as directed. (A) On rough side. b) In cement mortar 1:4
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm down) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed.
f) Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
Supply fitting fixing M.S angles,M.S. flat ,M.S bolt and nuts including painting with red lead paint one coat complete as directed (a) M.S angle..
Supply fitting fixing M.S angles,M.S. flat ,M.S bolt and nuts including painting with red lead paint one coat complete as directed (b) M.S Flats..
Supply fitting fixing M.S angles,M.S. flat ,M.S bolt and nuts including painting with red lead paint one coat complete as directed (c) M.S Bolts and nuts....
Sanitary Works: Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (I) 2000 Lt capacity (a) Sintex make
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. (a) 2000 litre capacity.
Labour for boring hole for inserting tube well pipes through different soil/rockk media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. i) Bore hole of 75mm diameter
Supplying, fitting and fixing plain/bevel ended for casing, conforming to relevent IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign material in the annual space between the borehole and assembly pipes complete as directed by the Department. (i) G.I pipe a) TATA/SAIL (Medium) socket should be welded to the pipes. i) 50mm diameter
Supplying fitting and fixing GI filter 2.00 meter long.
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. (A) Exposed on walls a) 50 mm dia (Medium) i) Using tata make
Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified. f) 15 mm dia (Medium) i) Using tata make
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) (I) Jaquar (a) Continental / Clarion (i)15mm dia Male / Female
Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (Pipes will be measured and paid separately) A) CPCH a) Ligh type.
Supplying fitting and fixing Chrome plated (C.P.) sink cock of approved brand as directed and specified (G.I & C.P) pipes will be measured and paid separately) (I) Sona brand a) Sink cock upper/lower spout 15mm.
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. (A) 50 mm dia
(E) Construction of Garrage 2 Nos.: Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completion of work. breaking clods in return filling dressing. watering and ramming etc and removal of surplus earth with all lead & lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to a depth of 2.0 m below the existing G.L (a) In Ordinary Soil.
Providing brick soiling in foundation and under floor with stone/quality picked jhama brick, sand packed after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). b) ISI approved Super ductile TMT Bar. (i) TATA/SAIL
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (upto 1st floor level). C) ISI approved M.S rod
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.1. Columns, pillars, posts & strut of square/rectangular/polygonal in plan or any shape like Tee/L etc.having plane vertical face.
Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc. hight of propping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.2.1.2. Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate..... and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab, retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser b) M20 grade concrete or prop.1:1.5:3
Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate..... and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (b) In super structure from plinth level up to 1st floor level. (ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder.............and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or prop.1:1.5:3
Brick work in cement morter with 1st class brick including racking out and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:4
1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) i) 112mm thick brick wall. (a) In cement mortar in proporation 1:4
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming, etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (b) Using other ISI marked approved circular hollow section
Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc. (roof trusses and purlin etc. to be measured and paid separately) (e) 0.63mm thick
Plain cement concrete floors base in prop 1:3:6 laid in alternate bays as specified with coarse agg.of size 13mm to 32mm including dewatering if necessary, and curing etc complete. (c) 100mm thick
15mm thick cement plaster in single coat on single of half brick wall for interior plastering upto 1st floor level including arrises, internal rounded angles, not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. A) On rough side (b) In cement mortar 1:4
25 mm thick cement concrete topping 1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 12mm nominal size) finished with a floating coat of neat cement finish to be laid in panels including curing etc. complete as directed.
(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
(b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after thouroughly brooming the surfaces to remove all dirt and remains of loops powered materials.
Narayan Ch. Brahma
DHARAMSING NARZARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .