Loading…
Loading…
Tender ID
Tender Value
₹4.8 Cr
EMD Value
₹4.8 L
Closing Date
15 Apr 2026, 3:00 pmClosed
The Managing Director
Appointment of agency for SITC of Dynamic Lighting with Comprehensive 5 Years of DLP, O&M at Nadeshwari Mataji Temple, Nadabet, Gujarat
289488
2026
Open
Consultancy
Works
Gandhinagar
2 documents required · 2 mandatory
₹6,000
Tourism Corporation of Gujarat Limited
₹4.8 L
24 Mar 2026
24 Mar 2026
24 Mar 2026
15 Apr 2026
24 Mar 2026
Sr. No Description Unit Qty. Unit Rate Amount
Supply, Installation, Testing and Commissioning of LED ground burial light 18-24W or Higher having system output of minimum 600 lumens , CCT RGBW(W=3000K) , IP 67 protected aluminium housing. Luminaire shall
be capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of
the luminaire to ensure reliability. The controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow,
1 medium, wide or elliptical as per the site requirement. Operating voltage of luminare should be 24V DC. Luminaire should be provided with suitable separate non- integral power supply unit. Fixture shall be suitable to operate Nos. 16 33,446.00
at an ambient temperature range of -30°C to 50°C and complete luminaire shall be IP67 and IK10 rated. LED Life time shall be at least>50,000Hrs (Ta=35°C@L70).LED should be with of make OSRAM, CREE, NICHIA,
Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports and shall be complete with all necessary
accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of exterior RGBW(W=3000K) Linear Wall Washer light for facade lighting with extruded aluminium housing of 1000mm , powder-coated finish with tempered glass, optical
lens and grey finish fixture with total System wattage 15-18W or Higher with system lumen output 400lm with all LEDs on and minimum system lumen efficacy 35lm/w at RGBW(W=3000K) full output. Luminaire shall be
capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the
luminaire to ensure reliability .. the controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens made up of PC for each LED, offering beam angle of different types such as
narrow, medium, wide or elliptical as per the site requirement. The product should have separate Control and Power cable for higher reliaibility. DMX enabler circuit should be inside the Luminaire only. The rated voltage of
the Luminaire should be 24V DC. Fixture shall be suitable to operate at an ambient temperature range of -35°C to 45°C and complete luminaire shall be IP66 rated. LED Life time shall be >50,000Hrs (Ta=25°C@L70). LED
should be with of make OSRAM, CREE, NICHIA, Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs
Test Reports and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of 6M height decorative single arm pole Made in combination of mild steel pipe sections 76mm dia. & 60mm dia..Top Decorative Castore design bracket made in combination
of steel pipe sections 60mm dia.(vertical), 42mm dia.(vertical & gradually bent ) & Gradually Bent 14mm dia. MS rods. Ms rods are bent in such a way that it connects between two edges of 42mm dia. pipe, thus forming a
loop. Bracket has decorative middle flower of dia 140mm along with a casted rod- weight-2.65 kgs. Multiple cast iron components such as Large leaf 370 mm long - starting width 100mm and ending width 150mm & weight-
3.75kgs.,small leaf 190mm long , starting width 40 mm and ending width 140mm. - weight-1.2kgs. are provided at different places for aesthetics. Entire bracket shall be made to get 770mm horizonal arm length & provide
pleasing aesthetics. Decorative Base in Steel - Its design starting with dia 260mm for 170mm height, then tapers to 180mm, followed by a cylindrical section of 165mm dia., 365mm Height. It ends with a Top section consist of
a Ring of 205mm dia. and 40mm height followed by a taperinng section with Bottom dia. 175mm, Top dia 105mm and Height of 90mm. Total Height of the Base is 700mm. Decorative cast iron flower starting with a dia
mm increasing gradually to 160mm and then tapering to a dia 99mm.Total height of cast iron flower is 304 mm & weight is 6.3kgs. Decorative Ring (89mm/60mm-2.55kgs.) is made of cast iron. A Steel base plate of 300mm
x 300mm is welded at the bottom of the base. This base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. Top Ring-(weight- 3kgs.) are made of
cast iron. All cast iron parts weight mentioned are with +/- 5% tolerance. Entire pole including the decorative elements shall be made to provide pleasing aesthetics as approved by Architect/ Engineer in-charge. After
Fabrication, Entire Pole should be shot blasted for the effective adhesion of 3layer coating so as to avoid the corrosion. The pole should be provided with an inbuilt junction box with 1No. 32A Heavy Duty Stud type connector
and 1No. 6A SP MCB, at the bottom - the inbuilt box should have a flush door of suitable size. Wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole
strength. Pole & Cast iron parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint. Sample should be
submitted for approval from Architect/ engineer-incharge.
Supply, Installation, Testing and Commissioning of 50-60W, Power Module LED, 3000K, Suspended, Bell Shaped body completely made of aluminium. Auxiliary and optical compartment can be accessed by opening the
bottom plates. Drop shaped screen in polymethylmethacrylate (PMMA), transparent. Shock resistance IK06 made in single piece. Pure polyester powder coating in Customized Metallic Grey Colour. Silicone gasket between
the frames ensures IP Rating - IP 65minimum. Height – 405mm,Diameter - 347mm,Weight - 5Kgs., Power LED Module with Company /brand name printed on PCB with the metal core plate.LED Chips of
CREE/NICHIA/OSRAM/LUMILEDS make - same should be supported by LED manufacturer's tech sheet . Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short
Circuit, Over- Voltage & Over- Current, with in-built surge protection (an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens in PMMA/PC . LED Lifetime
>1,00,000hours. LM80 report from LED Manufacturer should be submitted. Sample should be submitted for approval from concerned engineer-in charge. The Light fixture shall be in compliance IS 10322-Supporting Test
Report from 3rd party NABL aboratory should be submitted along with BIS Certificate with manufacturer name same as brand proposed should be submitted.
Supply, Installation, Testing and Commissioning of Flexible Outdoor type LED Flex suitable for applications of Facade Lighting. Beam angles: 120deg with CCT 3000K. Standard Length of LED Strip should 10/15mtr to
minimise the Gap. The product should be built with internal optic mechanism for best effect. The rated voltage of the Luminaire should be 24VDC, Power consumption should be between 5W or Higher at steady state full
intensity for 1m. Luminaire should be provided with suitable separate non- integral power supply unit, mounting channels etc. the product should be have dimension of Ingress Protection should be IP 67 with warranty 5 year.
The product should be of size 12X12 with 10 % tollerance to the dimension. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. LED should be of make OSRAM, CREE, NICHIA,
Lumileds only. The products shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. the controller should be of the same
make as that of the product.
Supply, Installation, Testing and Commissioning of exterior RGBW(W=3000K) projector light for facade lighting with aluminium die-cast housing, powder-coated finish with tempered glass, optical lens and grey finish fixture
with total System wattage 20-24W or Higher with system lumen output 600lm with all LEDs on and minimum system lumen efficacy 35lm/w at RGBW(W=3000K) full output. Luminaire shall be capable of producing
dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the luminaire to ensure
reliability .. the controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens made up of PC for each LED, offering beam angle of different types such as narrow, medium,
wide or elliptical as per the site requirement. The product should have separate Control and Power cable for higher reliaibility. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire
should be 24V DC. Fixture shall be suitable to operate at an ambient temperature range of -35°C to 45°C and complete luminaire shall be IP66 rated. LED Life time shall be >50,000Hrs (Ta=25°C@L70). LED should be of
make OSRAM, CREE, NICHIA, Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports and
shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, installation, testing and commissioning of Backlit Cutout in ceiling 2000X900MM or as per site requirement with ACP routing channel box 3 mm, ACP routing box, ACP sheet white colour, ACP cutting on CNC,
Back site acrylic , 2.4 inch embossed channel box side wall white colour inside Led, Power supply for LED with required mounting accessories. IP65, impact resistance level should be suitable to site condition, The LED
6 system with control gear unit is suitable for operation on direct voltage supply grids. The luminaire should be provided with Electrical safety class I. 100 mm sides of Signage by bendable alum alloy Both back & side assemble Nos. 342 26,068.00
with by Argon welding. Top signage sheet fabricated of 5 mm thick, Opal Cast A grade PMA sheet ¾” ring made of 5 mm plexi. IP-65 High power chips LED modules 12V DC 1-1.4-watt beam angle 140/160 Input voltage
220V AC -Input frequency 47 Hz Max. Output power 300/200/100 W. The bidder must obtain the client's approval and offer multiple option for the content design.
Supply, installation, testing and commissioning of Backlit Cutout Surrounding Column 450X450X3000MM or as per site requirement with with required MS Structure, ACP routing channel box, ACP routing box, ACP sheet,
ACP cutting on CNC, Back site acrylic,Power supply for LED with required mounting accessories. IP65, impact resistance level should be suitable to site condition, The LED system with control gear unit is suitable for
7 operation on direct voltage supply grids. The luminaire should be provided with Electrical safety class I. 100 mm sides of Signage by bendable alum alloy Both back & side assemble with by Argon welding. Top signage sheet Nos. 16 68,530.00
fabricated of 5 mm thick, Opal Cast A grade PMA sheet ¾” ring made of 5 mm plexi. IP-65 High power chips LED modules 12V DC 1-1.4-watt beam angle 140/160 Input voltage 220V AC -Input frequency 47 Hz Max.
Output power 300/200/100 W. The bidder must obtain the client's approval and offer multiple option for the content design.
Supply, Installation, Testing and Commissioning of LED ground burial light 12W or Higher having system output of minimum 400 lumens , RGBW(W=3000K) , IP 67 protected aluminium housing. Luminaire shall be
capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the
luminaire to ensure reliability. The controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium,
8 wide or elliptical as per the site requirement. Operating voltage of luminare should be 24V DC. Luminaire should be provided with suitable separate non- integral power supply unit. Fixture shall be suitable to operate at an Nos. 86 22,540.00
ambient temperature range of -30°C to 50°C and complete luminaire shall be IP67 and IK10 rated. LED Life time shall be at least>50,000Hrs (Ta=35°C@L70 LED should be of make OSRAM, CREE, NICHIA,Lumileds
only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports and shall be complete with all necessary
accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of exterior RGBW(W=3000K) projector light for facade lighting with aluminium die-cast housing, powder-coated finish with tempered glass, optical lens and grey finish fixture
with total System wattage 40-48W or Higher with system lumen output 1200lm with all LEDs on and minimum system lumen efficacy 35lm/w at RGBW(W=3000K) full output. Luminaire shall be capable of producing
dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the luminaire to ensure
reliability .. the controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens made up of PC for each LED, offering beam angle of different types such as narrow, medium,
wide or elliptical as per the site requirement. The product should have separate Control and Power cable for higher reliaibility. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire
should be AC100-277V. Fixture shall be suitable to operate at an ambient temperature range of -35°C to 45°C and complete luminaire shall be IP66 rated. LED Life time shall be >50,000Hrs (Ta=25°C@L70). LED should be
of make OSRAM, CREE, NICHIA, Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports and
shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of exterior RGBW(W=3000K) projector light for facade lighting with aluminium die-cast housing, powder-coated finish with tempered glass, optical lens and grey finish fixture
with total System wattage 40-48W or Higher with system lumen output 1200lm with all LEDs on and minimum system lumen efficacy 35lm/w at RGBW(W=3000K) full output. Luminaire shall be capable of producing
dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the luminaire to ensure
reliability .. the controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens made up of PC for each LED, offering beam angle of different types such as narrow, medium,
wide or elliptical as per the site requirement. The product should have separate Control and Power cable for higher reliaibility. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire
should be AC100-277V. Fixture shall be suitable to operate at an ambient temperature range of -35°C to 45°C and complete luminaire shall be IP66 rated. LED Life time shall be >50,000Hrs (Ta=25°C@L70). LED should be
of make OSRAM, CREE, NICHIA, Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports and
shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of exterior RGBW(W=3000K) Linear Wall Washer light for facade lighting with extruded aluminium housing of 1000mm , powder-coated finish with tempered glass, optical
lens and grey finish fixture with total System wattage 36W or Higher with system lumen output 1200lm with all LEDs on and minimum system lumen efficacy 35lm/w at RGBW(W=3000K) full output. Luminaire shall be
capable of producing dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the
luminaire to ensure reliability .. the controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens made up of PC for each LED, offering beam angle of different types such as
narrow, medium, wide or elliptical as per the site requirement. The product should have separate Control and Power cable for higher reliaibility. DMX enabler circuit should be inside the Luminaire only. The rated voltage of
the Luminaire should be AC100-277V. Fixture shall be suitable to operate at an ambient temperature range of -35°C to 45°C and complete luminaire shall be IP66 rated. LED Life time shall be >50,000Hrs (Ta=25°C@L70).
LED should be of make OSRAM, CREE, NICHIA, Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs
Test Reports and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of RGBW(W=3000K) projector light for facade lighting with aluminium die-cast housing, powder-coated finish with tempered glass, optical lens and grey finish fixture with
total System wattage not exceeding 120-135W with system lumen output 4400lm with all LEDs on and minimum system lumen efficacy 35lm/w at RGBW(W=3000K) full output. Luminaire shall be capable of producing
dynamic color changing light with 16 million colors as the light fixture should be programmable using 8 bit control DMX512 protocol / Ethernet based control and should of the same make as that of the luminaire to ensure
reliability .. the controller should be of the same make as that of the product. Luminaire should be complete with dedicated Lens made up of PC for each LED, offering beam angle of different types such as narrow, medium,
wide or elliptical as per the site requirement. The product should have separate Control and Power cable for higher reliaibility. DMX enabler circuit should be inside the Luminaire only. The rated voltage of the Luminaire
should be AC100-277V. Fixture shall be suitable to operate at an ambient temperature range of -35°C to 45°C and complete luminaire shall be IP66 rated. LED Life time shall be >50,000Hrs (Ta=25°C@L70). LED should be
of make OSRAM, CREE, NICHIA, Lumileds only. The product should be BIS approved with R number mentioned on product label. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports and
shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.
Supply, Installation, Testing and Commissioning of Flexible Outdoor type LED Flex suitable for applications of Facade Lighting. Beam angles: 120deg with CCT 3000K. Standard Length of LED Strip should 10/15mtr to
minimise the Gap. The product should be built with internal optic mechanism for best effect. The rated voltage of the Luminaire should be 24VDC, Power consumption should be between 12-15W max at steady state full
intensity for 1m. Luminaire should be provided with suitable separate non- integral power supply unit, mounting channels etc. the product should be have dimension of Ingress Protection should be IP 67 with warranty 5 year.
The product should be of size 12X12 with 10 % tollerance to the dimension. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. LED should be of make OSRAM, CREE, NICHIA,
Lumileds only. The products shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. the controller should be of the same
make as that of the product.
Supply, Installation, Testing and Commissioning of 30 W LED uplighter for tree illumination shall be a high-efficiency outdoor luminaire designed for landscape and architectural lighting applications. The fitting shall operate
on a wide input voltage range of AC 85–265 V, 50/60 Hz and consume a maximum power of 30 W ±10%, with a power factor of not less than 0.90. It shall be equipped with an inbuilt constant-current electronic driver having
protections against short circuit, over-voltage, surge, and thermal overload. The light source shall consist of high-efficacy SMD or COB LEDs with a minimum luminous output of 2700–3000 lumens and an efficacy of not less
than 80 lm/W. The correlated colour temperature shall be available in 2700 K, 3000 K, 4000 K, or 5000 K options, with a colour rendering index (CRI) of minimum 80. The luminaire shall be provided with precision optics
and tempered glass cover, offering beam angles of 15°, 24°, 30°, 45°, or 60° to suit various tree heights and canopy spreads. The housing of the uplighter shall be manufactured from pressure die-cast aluminium with corrosion-
14 resistant powder-coated finish suitable for long-term outdoor use. It shall be provided with an adjustable mounting arrangement including ground spike and/or surface mounting bracket to allow vertical and angular positioning Nos 60 33,600.00
for proper uplighting of trunks and foliage. The luminaire shall have a minimum ingress protection rating of IP65 to ensure resistance against dust, rain, and water splashes, and an impact resistance rating of at least IK06 for
public and landscape areas. Efficient thermal management shall be ensured through an integrated heat-sink design to maintain optimum operating temperature and prolong LED life. The operating temperature range shall be
from –25 °C to +45 °C, suitable for Indian climatic conditions. The uplighter shall have a rated service life of not less than 40,000 to 50,000 hours at L70 and shall maintain stable light output throughout its operational life.
Optional dimming and control interfaces such as 0–10 V, DALI, or DMX may be provided where required for project integration. The luminaire shall comply with relevant IEC/IS safety standards and shall be certified for CE,
RoHS, and EMC compliance. Each unit shall be supplied with necessary mounting accessories, weatherproof cable entry, and installation hardware.
Supply, Installation, Testing and Commissioning of of IP Rated Laser Source Beam Moving Head : Max Power - 200W , Light Source - 100W Laser Source , Beam Angle - 0.5°-5°, Minimum Illuminance ≥ 200,000lx @20m,
0.7°, Luminous flux ≥3000lm, Lens diameter : 180mm , Pan/Tilt rotation : 540°/270° (8-16bit), Dimmer : 0-100% 24Bit, Cooling : Forced Convection, Static Gobo : 19 gobos+white,Rotating Gobo : 6 Gobos, Prism : One
prism +One 8 prism, bidirectional (Rotating speed can be adjusted), Colors : One color wheel (19 color+white, rainbow-floweffect), Colour Mixing Type - CMYk , CMY, Casting : Magnalium and Die-cast, Ambient Temp : -
20° - 45°, IP Rated : IP66 , BIS.
Supply, Installation, Testing and Commissioning of Main LED Controller. It is an intelligent controller, supports PC as well as SD card control, works with sub-controllers and capable to switch freely between PC control and
16 SD card control automatically, when needed. Shall be having LCD interface to display the current program information. Shall be having addressing feature to address the connected DMX devices in the loop without requiring Nos. 1 5,49,231.20
additional interface. Shall be having future expansion capability to get integrate with 3rd party devices. Input Power- 100 to 240 V AC @ 50 Hz. Power Consumption <10W. Maximum supported pixels:
Supply, Installation, Testing and Commissioning of Sub LED Controller, complete with unique data processing method for the display on complex architectural buiding facade. Shall be able to work with PC as well as Main
LED controller on ArtNet or Ethernet. In both the modes, it controls a variety of chips in LED fixtures. Unique Controller ID address can be set automatially as well as manually using its screen and buttons. Effects are fully
customizable and can be created using PC based software tool. Shall be having LED screen to display and set multiple parameters. Controller shall be having 8-ports, which can be configured for DMX/ RDM/ SPI/ TTL
protocols. Input Power- 100 to 240 V AC @ 50 Hz, Power Consumption <5W.
Supply, Installation, Testing and Commissioning of DMX Splitter/ Amplifier. Shall be having 4 independent output DMX ports to control upto 32 devices on each port. Each port shall be of XLR type connector. Shall be
capable to integrate on DMX. Input Power - 100 to 240 V AC @ 50Hz.
19 Supply, Installation, Testing and Commissioning of DC24V 350W Driver - AC100~200V input, DC24V output, 350W, constant voltage power supply IP Rating : IP67. Nos. 60 6,300.00
20 Supply, Installation, Testing and Commissioning of Pole with Brackets arrangement with Silver Powder coated for RGB Flood Lights for Mounting of RGB Flood Light. Job. 1 2,03,000.00
21 Supply, Installation, Testing and Commissioning of Brackets arrangement with Silver Powder coated for Spot Light and Wall Washers for Mounting of Spot Light and Wall Washers. Job. 1 2,52,000.00
22 SITC of Column loudspeaker 30W, metal, black Approved by Competent Authority Ea. 15 11,460.90
SITC of Power amplifier, 2x500W 2 ✕ 500 W class-D power amplifier (70/100 V output) Low power consumption in standby mode Excellent sound quality, high signal-to-noise ratio EN 54-16 and ISO 7240-16 system
SITC of Premium ultra-low noise, high headroom mixer, 10 state-of-the-art, phantom-powered Mic Preamps, 8 studio-grade compressors and control LED for professional vocal and instrumental sound, Ultra-high quality FX
processor with LCD display and storable user parameter settings, 4 aux sends per channel, 4 subgroups, 4 multi-functional stereo aux returns with flexible routing, Long-wearing 60-mm logarithmic-taper faders.
25 SITC of UHF Wireless Handheld microphone system.Frequency Response : 60 Hz to 16000 Hz.Dynamic Range 108 dB or higher.Operating range: 60 m.No. of Channel : 2x 4-frequencies. No 2 32,900.00
26 Buzz stop device. Device should be able solve humm and buzz problems in the system. No 1 31,920.00
Ultra-Flexible 8-Channel Splitter/Mixer Ultra-low noise 8 in / 2 out line mixer and 2 in / 8 out line splitter, Each channel can operate independently in mixer or splitter mode, Usable as 6 in / 6 out level matching amplifier or
line driver, Converts levels between -10 dBV and +4 dBu, Extremely wide bandwidth for highest signal integrity, 6 mono in, 6 mono out, 2 main inputs and 2 outputs, 8-segment input/output level meters for all channels.
28 SITC of AUDIO RACK : 24 AUDIO RACK AS PER REQIERD WITH ALL ACCESSORIES. 44,660.00
29 SITC of SPEAKER CABEL : 2.5 SQ.MM 2C WITH PVC JACKET. Mtr. 450 147.00
30 SITC of CABELS AND CONNECTORS : CUSTOMIZED AS PER REQIERMENT. 35,000.00
31 SITC of SPEAKER POLE AND MOUNTING : AS PER REQIERMENT FOR SITE SITUATION. 2,10,000.00
32 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. 3 core 2.5 Sq. mm Mtr. 7500 149.60
33 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. . 3 core 4 Sq. mm Mtr. 2000 205.70
34 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. 3 core 4 Sq. mm Mtr. 650 313.50
35 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. 3 core 10 Sq. mm Mtr. 650 544.50
36 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables. 3 core 16 Sq. mm Mtr. 650 792.00
37 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. 2 to 4 core 2.5 / 4 Sq. mm Ea. 60 36.30
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. 1.5/2.5 to 6 Sq.mm
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting mob & hinged doors as per
requirement having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box. 300mm x 200mm x 135mm [deep]
40 SITC of CAT6 UTP 23AWG Solid: Per Meter Ea. 3500 47.30
41 Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault all over the run and back filling the same and making the surface as normal ground. Mtr. 3500 60.50
42 Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for laying any size of cable or locating the fault all over the run and back filling the same and making the surface as normal ground. Mtr. 1300 81.40
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable.50 mm outer dia
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting, welding, grinding & finishing duly
painted with one coat of red oxide with erection on site as per direction of engineer in charge with necessary grouting, cementing, plastering & finishing complete.
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps
with following dia of pipes, in approved manner as directed. 25 mm
46 Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. 25 mm Mtr. 1360 23.10
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following
size of cables. 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following
size of cables. 4 core 6 Sq. mm
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia
of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications with chamber and heavy duty cover. (A)(approved make OEM has to submit test certificate including value of earth resistance of installation duly stamped and
signed by agency and officer Incharge has to ensure the value of earthing resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing
as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for long time Necessary test report must be
submitted by Agency.
For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil.
Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper
ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
52 Excavating hard rock or bituminous road (B.T.) by chiselling or using tool and tackles for preparing pit for poles or earth plates or for laying pipes & clearing the site by removing debris & making site good. Cu.Mtr 5 653.40
53 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. Kg. 170 84.70
Supplying & erecting IP 55 grade following size section pillar fabricated from joint less M.S. Sheet with angle iron legs made from jointless M.S. Angle with cable clamps to be buried in ground to have appropriate erection to
work uniform until erected with cement concrete foundation and 45 cm high bricks work finishing with plaster etc. hinged double door internally supported on both side,with internal and outside looking arrangement with look
and keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is welded and other with nut and bolt for erecting Bakelite sheet. Painting the Section Pillar inside and out side with three tank powder coated paint. 75 X
X 45 cm section pillar fabricated from 16 Gauge MS Sheet with angle iron legs 45 cm long made from 35 X 35 X 5 mm thick MS angle.
55 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity. 63 Amp. Ea. 14 803.00
56 Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity. 6 to 32 Amp Ea. 6 649.00
57 Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity. 6 to 32 Amp. Ea. 54 326.70
Providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component for following Max. rating erected as directed. 63 Amps. FP
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating
59 contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as Ea. 3 3,450.70
required with necessary connection erected as directed.
60 Supplying & erecting power contactor ,AC3 duty for time switch complete erected. 4 pole 440V 40 Amp. Ea. 3 3,030.50
61 Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, complete erected with necessary connections. Ea. 40 47.30
62 providing and erecting Miniature circuit breaker single pole 0.5A to 2A system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Ea. 15 294.80
Supplying and erecting approved make panel mounting type Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts range erected on existing panel board with all connection, wiring etc .with manufacturers
calibration certificate.
Supplying and erecting approved make panel mounting type Digital Ammeter having 3 digits LED display, external CT operated, calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC , erected on existing panel
board with all connection, wiring etc .with manufacturers calibration certificate.
65 Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with insulating materials connected to the meter Ea. 15 299.20
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. One wire 10.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. One wire 1.00 sq. mm
68 Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to be erected as directed of following size. 3 core 4 Sq. mm Mtr. 1150 205.70
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following
size of cables. 4 core 6 Sq. mm
70 Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. 2 to 4 core 6 Sq. mm Ea. 8 41.80
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release
71 suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. housing/Encloser of MCCB for (The Enclosures should be used of same Ea. 2 6,723.20
company of MCCBs to be used). ICS=100% of ICU only
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed thermal & magnetic release
72 suitable to work on A.C. supply 50 c/s. with all internal connections, spreader tinned copper & complete erected in existing 16 G.M.S. housing. housing/Encloser of MCCB for (The Enclosures should be used of same Ea. 3 5,832.20
company of MCCBs to be used). ICS=100% of ICU only
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
cables. 3 1/2 core 25 Sq. mm ( 10 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
cables. 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of
cables. 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
Providing and, fixing heavy duty flange type brass double compression type cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. 3 &
1/2 / 4 core 25 Sq. mm
Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. 25 Sq.mm.
78 Providing and erecting required size HOT deep Galvanised iron strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using proper clamp. Kg. 100 84.70
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable. 50mm outer dia
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable. 63mm outer dia
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated outdoor type double door cubical panel board necessary IP-54 and above protection as per approval from engineer incharge made from
14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats channel including cutting, bending, drilling, welding, riveting
with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection of supplied switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-aluminium strips,
81 rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber Sq.Mtr 10 19,554.70
gasket,heavy duty end terminal connection,danger notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with epoxy powder coating. (The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers with following size.(C) The
standard companies switch gear shall be used and only manufacturers at CPRI approved factory as per IEC 61439 for beneficial use. with 350mm depth
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm (Rated current / cross section area)
82 duly wrapped with colour insulating tape for phase sequence of following current carrying capacity, erected with necessary bus bar supports/insulators, main cable socket to each bar, erected in existing cubical panel with Rn.Mtr 24 3,488.10
necessary connections. Suitable for 200 Amp. capacity
Providing and erecting Approved make Earth fault Relay suitable to mount with inter connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB rating as following along with shunt trip
220V AC. with all internal connections & complete erected in existing M.S.housing.. 15 A -100 A , CT Ratio 1/100
84 Supplying & erecting approved make Four Pole 415V change over switch interior for panel mounting with operating mechanism A.C.23 duty confirming to IS. 100-125A Ea. 1 8,484.30
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size
(Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. One wire 16.00 sq. mm
86 Providing and erecting metallic vitrified danger notice board as per language suggested by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. Ea. 11 75.90
87 Supplying rubber matting of following thickness as per IS:15652/IEC 61111. 3mm Sq.Mtr 6 839.30
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections
as per site situation directed by Engineer In charge. 16 Amp. SP one way switch
Providing following type of Modular Type Accessories mounted with PVC / metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate , modules erected with necessary connections
as per site situation directed by Engineer In charge. 6/16 Amp. Universal Socket
Supplying and erecting approved make of tube fitting with One no T-5 tube 24/ 28 W with Electronic ballast with each tube separately THD less than 10 & built in adaptors, GI / PVC housing & mirror optic reflector,
suitable to work on 120V - 300V, A.C. supply with connector and adapter if required. [Make of fitting & tube may be differ& fitting shall be providing with tube]
Providing and erecting, heavy duty flood light integral luminaire comprises die cast aluminium body with heat resistant toughened front glass, silicon rubber gasket,anodised reflector hot deep powder coated cradle clamp
with suitable size of necessary built in control gear complete with lamp. with one no. 70 watt HPSV / Metal halide lamp
92 Marble Slab White adango as per the site requirment. Cutting as well New instllaation. It is also required new marble of different sizes as per the site requirements. Cost is all inclusive. Sq. Mtr. 500 889.83
Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with Solar Panels (ALMM approved): Frame Material : Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover
: High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and positive power tolerance Pmax: 0/+5, Module Efficiency should be approx. 19.5%-22%, Normal operating temperature 45'C, Junction Box
with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal or better than -0.45%/degree
C. Solar PV modules of minimum fill factor 75% to be used. Unit Production:- More than 4.5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power Warranty includes all mechanical
and electrical parameters of the Solar panel. Modules must be complied to the DCR(Domestic content requirements). The Ration of AC to DC is 5:6 for the Installation capacity which are given in AC KW.
Solar Inverter: MPPT Range: MPPT Range: 80-1000 V , Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -
25~60°C, Integrated protection of Inverter are Anti-islanding Protection, Input Reverse Polarity Protection, Insulation Resistor Detection, Ground fault protection, Residual Current Monitoring Unit, Output Over Current
Protection, Output Short Circuit Protection, Output Over Voltage Protection, PV array string fault Protection. Protection Degree: IP65, User Interface LCD & APP, Datalogger & Communication: GPRS / Wi-Fi.
Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over Current Protection Integrated, Output Short Circuit Protection
Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: The mounting (Rectangular pipe /
square pipe / circular pipe) with requisite cross bars, nuts and bolts, etc. shall be Hot deep galvanized with minimum 80micron coating. The Rectangular / square /circular hollow pipe section used for the structure should have
a minimum thickness of 2.0 mm. other than above, the material thickness should be minimum 2.5 mm. A certificate of a structural engineer certifying the strength and stability of the mounting structure to withstand the weight
and wind speed of 150 km/hour throughout the life span of 25 years of the system, shall be submitted by the vendors. Hot Dipped Galvanized steel coils. suitable arrangement for base plate for foundation , solar panel
mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture should be
(SS 304) quality.The ground clearance of the bottom most edge of solar panel shall not be less than 300 mm to 1200 mm or as per site’s technical/feasibility requirement.
a. Column –The minimum section (thickness) should be 60MM*40MM
b. Rafter - The minimum section (thickness) should be 60MM*40MM
c. Purlin - The minimum section (thickness) should be 40MM * 40MM Balane of System with necessary Swichgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing system as per the
CEIG drawing approval, lightining arrester system as per the CEIG drawing approval, all liasoning work with various gov. dipartment like state nodal agency,DISCOM & CEIG is included in agency scope
(Excluding All charges namely GEDA Application fees, Solar connectivity Charges, Meter connectivity Charges, Meter testing Charges and system stability/strenthning charges.). If soarea lar instllation will be installed in the
diffrent surrounding area of temple cost is inclusive of all the parts and inverter). Grid Tied Solar Power System: 26 - 50 kW (3 - phase)
Note: G.S.T should be extra as actual
Note: The above cost is inclusive of five (05) years of Operations and Maintenance and DLP
Estimated Amount as put to Tender Rs. 4,82,01,040.30/- + G.S.T.
Note 01: All works shall be carried out as per public work department hand book and other specifications if Division or as directed
Note 02: Rates quoted include clearance of site (Prior commencement of work and its close) in all respects and hold good for work under all conditions, site, moisture/ weather,etc.
Note 03: Rates quoted include clearance of site (Prior commencement of work and its close) in all respects and hold good for work under all conditions, site, moisture/ weather, etc
Note 04: The Contractor shall exhibit a board as per Government Circular No. BDG/ 3277/ 1657/ N Dated 26/1/1997 S(M.GUJ) with detailed specifications and details of work and amount involved at the site without any payment as directed by the Engineer-in-charge.
Note 05: All the columns in schedules should be filled in ink and the total of the entries in ink last column should be struck by the contractor under his signature.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ANNEXURE A SCOPE OF WORK_NADESHWARI MATA TEMPLE_NADABET.pdf
ANNEXURE B SCOPE OF WORK.pdf
ANNEXURE C PAYMENT TERMS AND CONDITIONS.pdf
ANNEXURE D ACCEPTANCE.pdf
ANNEXURE E GENERAL AND SPECIAL CONDITION OF THE BIDDER.pdf
ANNEXURE F TECHNICAL STAFF DETAILS_NADEHWARI MATA TEMPLE_NADABET.pdf
ANNEXURE G SPECIAL NOTES_NADESHWARI MATA TEMPLE_NADABET.pdf
Annexure-A TCGL_ELIGIBILITY CRITERIA.pdf
PRICE BID_NADESHWARI MATAJI TEMPLE_21.03.2026.pdf
TCGL_ELIGIBILITY CRITERIA_NADESHWARI.pdf
TENDER DOCUMENT.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .