Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.5 LQualified Make: Koel Green Electro
Model: KOEL GREEN KG1-250WS2 WITH PART NO. 318152-3212 1402 1402 CHIRANJIV TOWER 43 NEHRU PLACE NEW DELHI 110019 NEHRU PLACE NEW DELHI UTTAR PRADESH 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Koel Green Electro
Model: KOEL GREEN KG1-250WS2 WITH PART NO. 318152-3212 | ₹17.5 L | L1 | Qualified |
| 2 | Not yet disclosed by govt. Qualified Make: Koel Green Elmech
Model: KOEL GREEN KG1-250WS WITH PART NO. 318250-3004 NO 4 | Make: Koel Green Elmech
Model: KOEL GREEN KG1-250WS WITH PART NO. 318250-3004 NO 4 | - | - | Qualified |
| 3 | Not yet disclosed by govt. Qualified Make: MAHINDRA - GSP
Model: MM306250SOTTCI(COE)-C2 | Make: MAHINDRA - GSP
Model: MM306250SOTTCI(COE)-C2 | - | - | Qualified |
| 4 | Not yet disclosed by govt. Qualified Make: JAYCO POWER
Model: JAYCO POWER & JEC-250EA-SITC | Make: JAYCO POWER
Model: JAYCO POWER & JEC-250EA-SITC | - | - | Qualified |
| 5 | Not yet disclosed by govt. Qualified Make: Mahindra
Model: Mahindra Powerol Perfect | Make: Mahindra
Model: Mahindra Powerol Perfect | - | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 Sept 2018, 3:00 pmClosed
diesel generators- DG Sets Average Turn Over of Last 3 Years 50 Lakh (s) Experience with Gov. Required 3 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 250 250 (or higher) No of Phase - Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine true * Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Electronic Mechanical
Electronic (or higher) Class of governer A1 A0
A1
A2 (or higher) 1/5 Number of cylinders (nos) 6 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 24 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 250 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 92.7 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 (or higher) Thickness of Foam 47 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * 2/5 No of batteries 2 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nyavanandhi Anil Reddy 737116
107 RCC (GREF)
C/O 99 APO
PROJECT - SWASTIK LOCATION ; MANUL 1 60
634691
GEM/2018/B/90084
diesel generators- DG Sets
60 days
Sikkim; North District
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Average Turn Over of Last 3 Years 50 Lakh (s) Experience with Gov. Required 3 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 250 250 (or higher) No of Phase - Three Phase ENGINE Make of Engine - * Model Number of Engine - * Capacity of Engine (cc) - * Engine Power (kWm) - * ISI Marking to IS :10001 for engine true * Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Electronic Mechanical | - | - | - |
| Electronic (or higher) Class of governer A1 A0 | - | - | - |
| A1 | - | - | - |
| A2 (or higher) 1/5 Number of cylinders (nos) 6 * No of Strokes (nos) 4 * Rated RPM of Engine (RPM) - 1500 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 * Specific Fuel Consumption (gm/kWh) - * Starting voltage (volt) 24 * ALTERNATOR AC GENERATOR(ALTER NATOR) Make - * AC GENERATOR(ALTER NATOR) model Number - * Rating of AC Generator (KVA) 250 * Power Factor of AC generator 0.8 * Efficiency at rated Power factor at 75% of full Load 92.7 * Compliance of Alternator to IS:13364(part-1) Yes * Type of alternator Brushless * Voltage Regulation Grade VG 3 * Alternator IP Rating IP 23 * Class of Insulation H * CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 * ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 (or higher) Thickness of Foam 47 * Density of Foam for sound insulation 28 * Noise level at 1 meter (dB) 75 * BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance * Battery capacity (Ah) - * 2/5 No of batteries 2 * TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes * Test Report number and date(Engine) - * Name and address of laboratory(Engine) - * Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes * Test Report number and date(Alternator) - * Name and address of laboratory(Alternator) - * DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes * WARRANTY INSTALLATION & COMMISSIONING Warranty 2 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nyavanandhi Anil Reddy 737116 | - | - | - |
| 107 RCC (GREF) | - | - | - |
| C/O 99 APO | - | - | - |
| PROJECT - SWASTIK LOCATION ; MANUL 1 60 | - | - | - |
Exempted
26 Oct 2018
19 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_634691.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .