Loading…
Loading…
Tender Value
₹9.4 Cr
EMD Value
₹9.4 L
Closing Date
9 Sept 2026, 5:00 pm
ENC OFFICE
APMSIDC FLAT NO.9, SURVEY NO.49, IT PARK
Construction of First Floor over the existing Ground Floor of Government Naturopathy & Yoga College in VIMS premises at Visakhapatnam District
980712
2-9/APMSIDC/Technical/2026-27, Dated.18.08.2026
OPEN - NCB
Buildings
VISAKHAPATANAM, ANDHRA PRADESH
21 documents required · 21 mandatory
₹11,800
₹9.4 L
25 Aug 2026
25 Aug 2026
25 Aug 2026
Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete Brick Masonry
Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , overheads & contractor profit etc., complete Concrete
Earth work excavation for foundations (Mechanical Means) for buildings in ordinary soils and depositing on bank for all lifts and with an initial lead of 10m and up to 3m depth including all operational,incidental, labour charges such as shoring, sheeting, planking, strutting etc., and overheads & contractors profit complete for finished item of work excluding dewatering charges etc., as per SS 20 B(APSS 308)
Plain Cement Concrete (1:4:8) (cement: fine aggregate: Coarse aggregate) for foundations using coarse aggregate 40mm size hard , machine crushed granite from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site including all charges for machine mixing and hire charges of concrete mixer, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and overheads & contractors profit complete for finished item of work. (APSS No. 402)
Plain Cement Concrete (1:5:10) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site including all charges for machine mixing and hire charges of concrete mixer, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,and overheads & contractors profit complete for finished item of work. (APSS No. 402)
Filling with useful available excavated earth (excluding rock) with a lead of 50 m in trenches, sides of foundations and basement with initial lead in layers not exceeding 15cm thick, watering and ramming including cost and conveyance of water to work site and all operaitonal, incidental, labour charges, hire charges of T&P etc., and overheads & contractors profit complete for fnished item of work (APSS NO.309&310)
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Footing
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Pedestal
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., and overheads & contractors profit complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Plinth beam
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height of 3.66 m: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Columns : un supported height of 3.66 m: Third Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Lintels: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Lintels: Third Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) RCC wall 200mm thick: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Beams : un supported height of 3.66 m: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Beams : un supported height of 3.66 m: Third Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Slab-125mm thick : un supported height of 3.66 m: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Slab-125mm thick : un supported height of 3.66 m: Third Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Slab-150mm thick : un supported height of 3.66 m: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Slab-200mm thick : un supported height of 3.66 m: Second Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using casurina ballies, bamboos, wooden reapers, runners, wood posts, wall plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing , overheads & contractors profit etc., complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) Roof Slab-200mm thick : un supported height of 3.66 m: Third Floor
Supply and placing of the Design Mix Concrete M 30 grade corresponding to IS 456 with cement content of 400 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site, centering using casurina ballies , bamboos , wooden reapers , runners , wood posts , wall plates etc., for 60cm wide sun-shades 7.5cm thick at fixed end and 5cm thick at free end with an average thickness of 6.25cm including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, curing, overheads & contractors profit complete etc., but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402, 403 & 903) Second Floor
Plain Cement Concrete M 20 nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site including all charges centering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, centering charges, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for steps for finished item of work. (APSS No. 402) Second Floor
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).Second Floor
Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, overheads and contrctor profit etc., complete for finished item of work. (APSS No. 501 & 504).Third Floor
Reinforced Masonry for partition walls (100 mm thick) in CM (1:4) prop. (Cement : Sand) using fly ash cement / lime solid blocks of size 290mm x 100mm x 140mm having minimum compressive strength of 50 Kg/Sq.cmand placing 2 Nos. of 6mm M.S plain rods in every third layer with free ends of the reinforcement pegged into mortar joints of main brick walls where applicable including cost and conveyance of all materials like cement, steel, sand, fly ash cement / lime solid blocks, water etc., to site, all operational, incidental charges such as labour charges for mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., and overheads & contractors profit but excluding cost of steel and its fabrication charges complete for finished item of work. (APSS No. of 509) Second Floor
Plain Cement Concrete (1:3:6) nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site including all charges for machine mixing, hire charges of concrete mixer, centering charges, laying concrete in position, curing etc., & lift charges , and overheads & contractors profit for bed blocks & hold fasts for finished item of work. (APSS No. 402) Second Floor
Providing Thermo Mechanically Treated (TMT) (Fe 500 / Fe 500 D grade as per IS 1786-1979) of different diameters for RCC works including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126) First floor
Providing Thermo Mechanically Treated (TMT) (Fe 500 / Fe 500 D grade as per IS 1786-1979) of different diameters for RCC works including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126) Second Floor
Providing Thermo Mechanically Treated (TMT) (Fe 500 / Fe 500 D grade as per IS 1786-1979) of different diameters for RCC works including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126) Third Floor
Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., and overheads & contractors profit complete for finished item of work.( APSS No.126) Second Floor
Ornamental ceiling plastering 12mm thick single coat in CM (1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) Second Floor
Ornamental ceiling plastering 12mm thick single coat in CM (1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., and overheads & contractors profit complete for finished item of work.(SS 901,903 & 904) Third Floor
Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer - in - charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Second Floor – Internal Plastering
Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer - in - charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Third Floor – Internal Plastering
Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer - in - charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) First Floor – External Plastering
Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer - in - charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Second Floor – External Plastering
Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves as directed by Engineer - in - charge etc., and overheads & contractors profit complete for finished item of work. (SS 901,903 & 904) Third Floor – External Plastering
Providing impervious coat to exposed RCC roof slab surfaces to required slopes with CM (1:3) prop. using screened sand 20mm thick (average) mixed with integral cement water proofing admixture confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 100ml per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903) Third Floor
Providing impervious coat to exposed RCC roof slab surfaces of sump , sump side wall,sump bottom slab,in side of septic tank , in sunken slabs etc. to required slopes with CM (1:3) prop. using screened sand 12mm thick mixed with integral cement water proofing admixture confirming to IS: 2645-2003 manufactured by reputed manufacturers as approved by Engineer-in-charge at 100ml per one bag of cement, laid over roof slab when it is green, finished smooth with a floating coat of neat cement and thread lining at regular intervals of 45cmx45cm where ever necessary including cost and conveyance of all materials like cement, sand, water proofing compound, water etc., to site, operational, incidental, and labour charges for mixing mortar, laying, lift charges, rendering smooth and thread lining, curing including rounding off junctions of wall and slab etc., and overheads & contractors profit complete for finished item of work. (APSS No. 901 & 903) Second Floor
Flooring with non-skid red or white full body Ceramic floor tiles of size 300 mm x 300 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) Second Floor
Flooring with non-skid Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,and overheads & contractors profit complete for finished item of work. (APSS No.701 & 707) Second Floor
Providing 18 mm to 20 mm thick Anti-skid Granite (Black) up to 2.43M (Stair case) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, full rounding the edges of treads , providing 3 grooves of size 2mm x 1mm for the full length of treads , polishing charges, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special) Treads of 0.30m wide : Second Floor
Providing 18 mm to 20 mm thick Anti-skid Granite (Black) up to 2.43M (Stair case) with borders and design as per the pattern approved by the Engineer-in-Charge of length not less than 2.43 mts set over base coat of cement mortar (1:5) , 12mm thick using screened sand over CC bed already laid or RCC roof slab including neat grey cement slurry of honey like consistency spread @ 3.3 Kg per sqm and jointed neatly with white cement paste mixed with pigment of matching shade to full depth including cost and conveyance of all materials like cement , sand , water , granite slabs etc., to work site and all operational, incidental labour & lift charges, full rounding the edges of treads , providing 3 grooves of size 2mm x 1mm for the full length of treads , polishing charges, cost of base coat and overheads & contractors profit complete for finished item of work for treads and risers (S.S.701 & special) Risers of 0.15m height : Second Floor
Providing skirting 10 cm height with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of Size 600 x 600 mm and thickness between 8-10 mm of any colour and finish in all shades and designs, length equal to flooring tiles, flushed to wall surface to set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and overheads & contractors profit complete for finished item of work.(APSS No.701 &707) Second Floor
Providing dadooing with glazed red or white full body ceramic wall tiles of size 300 x 450 mm / 320 mm x 400 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge flushed to wall surface set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., and overheads & contractors profit complete for finished item of work. Second Floor
Providing and laying of precast concrete blocks for paving of M-40 grade and thickness not less than 80 mm for medium traffic areas conforming to IS 15658:2006 in all shapes and designs as per the manufacturer's specification including cost and conveyanace cost of all materilas like cement, sand water and Pavers etc., Complete per drawings and techinical specification clause 1504 MORD including cost and conveyance of all materials and all labour charges, overheads and contractor profit etc., complete for finished item of work.
Filling with well burnt cinder aggregate as per IS:2686-1977 in sunken slabs including cost and conveyance of cinder, labour charges for filling, ramming, overheads and contractor profit etc., complete for finished item of work Second Floor
Reinforced cement concrete (1:5:10) proportion (Cement: fine aggregates: coarse aggregate) using 40mm size (SS5) hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc., to site including centering using Casurina Ballies , Bamboos , Wooden Reapers , Runners , Wood Posts , Wall Plates etc., shuttering, machine mixing, laying concrete, lifting concrete manually , vibrating, curing, etc., and overheads & contractors profit complete as per drawings but excluding cost of steel and it's fabrication charges for finished item of work (APSS NO. 402 & 403) for dummy columns. Third Floor
Supplying and fixing of stainless steel (grade 304) hand railing as per approved drawing with top rail of 50mm dia pipe and 2mm thick medium class and vertical posts of 25mm dia and 1.6mm thick medium class 1 No for each step fixed with base plate of 25mm dia using bonding agent and anchor fastner and welding, drilling of 25mm dia holes with pneumatic compressor for fixing railing, buffing, polishing all members of the railing thouroughly , lacquer finishing to present seamless finish including cost and conveyance of all materials, electrodes, welding charges, cost of all consumables, labour charges , overheads & contractors profit etc., complete for finished item of work.
Providing 110 mm Dia ISI marked PVC down water take pipes with single socket , 2.5mm thick 4.0 kg/sq.cm pressure of ISI marked including cost of necessary PVC Bends, couplers, shoes, iron / PVC clamps and all other accessories and fixing in position including cost and conveyance of all materials, operational & incidental charges including all labour charges for fixing at site etc., and overheads & contractors profit complete for finished item of work. (APSS No. 1328)
Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides, fixing 1mm thick mat finish laminated sheet to full width and height of the flush shutter both sides including cost and conveyance to site of teak wood frame, flush shutter, laminate sheet including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. Rubber / Nylon door stop bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1200mm x 2600mm)
Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides fixing 1mm thick mat finish laminated sheet to full width and height of the flush shutter both sides including cost and conveyance to site of teak wood frame, flush shutter, laminate sheet including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long , 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 1 No. door stopper and 1 No. Rubber / Nylon door stop bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including overheads & contractors profit complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1000mm x 2600mm)
Providing and fixing 28 -30 MM thick solid Wood Polymer Composite(WPC) single extruded door shutter with 3MM top and bottom rigid layer with an overall density of 750kg/Cum. It will be fixed to the frame using 3 inch /4 inch hinges. A minimum of 4 hinges will be required for fixing the door with the frame etc., complete as per direction of Engineer – in-Charge, manufacture specification and drawing including ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250 mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208),1 No. Rubber / Nylon door stop bushes including labour charges for fixing the shutter to frame etc., including overheads & contractors profit complete for finished item of work for door of size 800mm x 2100mm
Providing and fixing factory made solid Wood Polymer Composite (WPC) single extruded Door Frame section of size with encapsulation of 8MM rigid layer on all the six surfaces. The door frame will have a rebat of 32MM. Door Frame section of 45x90 MM . The two Vertical members are to be joined together with the horizontal member using 8x60 MM long MS Star full thread screws to be used with reverse forward speed control hand drilling machine. The ready/assembled door frame is fixed to the wall using hold fast or bolt fasteners. A minimum of 4 No.s of screws to be provided for each vertical member & minimum 2no.s for horizontal member.
Providing and fixing 3 Track 3 Shutter Pre painted Steel sliding Window fabricated from roll formed sections made of Galvanized steel colour coated /powder coated (Base Steel as per IS 513 „D‟ quality galvanized as per IS 277 with Zinc of 120 Gms./ Sq.mtr) with total coated thickness of 0.58mm. Primer Coat with epoxy primer of 5-7 microns thick, finished paint with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick. The External Section for Three Track Three Sliding Shutter should be of 44 x 107mm with a provision for bottom track insert profile of 10x9 mm made of aluminium. Section for Window glass shutter should be of 35x49mm , Section for Window Euro groove should be of 25x24mm made of plastic to accommodate standard accessories, and section for window lap strip should be of 21x4mm made of plastic. Section for Mesh Shutter should be of 35x49mm. The Window to be panelled with 4mm thick pin headed glass. The gaskets are to be made of Ethyl Propylene Diamine Manomer [EPDM]. Corner Brackets for internal and external frame to be made of glass filled nylon. Touch lock to be provided for Window Shutter. Sections are to be cut to length, joined and assembled by means of corner brackets. The above frame to be fixed to Brick/Concrete masonry by using Nylon self expanding caps and driving MS electroplated 80mm screws into the caps through frames. The Grill for safety for windows to be made of 10mm thick square rod bars with 152mm pitch including cost and conveyance of all materials, labour charges for fixing, overheads and contractors profit etc., for complete for finished item of work in all floors.
Supplying and fixing of Top Hung Ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, The Ventilator to be panelled 4 mm pinhead glass with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch C2176
Suplying and fabricating, erecting and fixing in position tabular trusses of approved design with Structural Steel conforming to I.S specifications including roof frame work consisting of rafters, ties struts and purlins including cost of foundations bolts, cleats, bearings plates, etc., complete as per the approved drawing including cost and conveyance of all materials, labour charges for fabrication and fixing, hire charges of all tools and plants, all incidental charges, overheads and contractor profit etc., complete for finished item of work in all floors as directed by the Engineer-in-Charge
Painting two coats with synthetic enamel paint Grade-I VOC (Volatile Organic Compound) content less than 50 grams/litre to new iron work including cost and conveyance of all materials to site, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors. (SS No. 1201, 1212 & 1207).
White washing two coats with white cement to ceiling to give an even shade after thouroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials , labour charges and incidental such as scaffolding , lift charges etc., and overheads & contractors profit complete for finished item of work in all floors.
Providing and applying Wall putty of White Cement or Polymer or Cement based of average 1 to 2 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, Sand the surface, clean & wipe off loose dust, applying knifing paste filler by putty knife / muslin pad, air dry for 2 - 3 hrs, sand with 180 and 320 No., emery paper for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges, over heads and contractors profit etc., complete for finished item of work in all floors for internal walls
Supply & application of one coat water based cement primer of interior grade I and two coats of synthetic polymer luxury plastic emulsion paint of superior grade having VOC (Volatile Organic Compound) content less than 50 grams/litre for internal walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors.
Supply & application of one coat water based cement primer of exterior grade II and two coats of synthetic polymer luxury plastic emulsion paint of superior grade having VOC (Volatile Organic Compound) content less than 50 grams/litre for exterior walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc., and overheads & contractors profit complete for finished item of work in all floors.
Providing and applying exterior texture of average 2 to 3 mm thickness over plastered surface to prepare the surface even and smooth after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, applying emery paper, Sand the surface, clean & wipe off loose dust, applying putty/ texture paint filler by putty knife / muslin pad, air dry for 2 - 3 hrs for the surface preparation including cost and conveyance of all materials to work site and all operational, incidental, labour charges, scaffolding charges, overheads and contractors profit etc., complete for finished item of work in all floors for external walls
Painting to new wood work and flush shutters with lappam finish , over a primary coat and painting two coats of synthetic enamel paint Grade-I VOC (Volatile Organic Compound) content less than 50 grams/litre of approved shade including cost and conveyance of all materials to site cost of primer coat and all labour charges etc. complete including applying sand paper on lappam coats for neat finish and overheads & contractors profit complete in all floors (APSS No.1200, 1207 & 1211).
Supplying and fixing Gyp Board Suspended regular single layer false ceiling (GS-MFSC-4.1) using 12.5 mm thick Gyp Board conforming to IS 2095 - 1993 fixing to Gyp steel GI perimeter channels of size 20 mm x 27 mm x 30 mm(web) of 0.55 mm thick along the perimeter of ceiling screw fixed to brick work/ partition at 610 mm c/c and suspending the frame work using Intermediate channels (45 mm x 15mm x 15mm x 0.9 mm) from soffit at 1220 mm c/c with ceiling angle (25 mm x 10 mm x 0.55 mm) fixed with GI Cleat and steel expansion fasteners & connecting clip to the ceiling channels (with knurled web of 51.5 mm x 26 mm x 10.5 mm x 0.55 mm) fixed in direction perpendicular to the intermediate channel at 457 mm c/c and fixing the 12.5 mm tapered edge Gypboard with 25 mm drywall screws at 230 mm c/c & jointing and finishing using joint compound and paper tape to have a flush look including filling the tapered & square edges with jointing compound, two coats of drywall top coat including overheads and contractor profit etc., complete for finished item of work
Supplying and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with G.I ‘J’ bolts & nuts 8 mm dia with bitumen & G.I limpet washers filled with white lead & including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (up to a pitch of 600) etc., complete, excluding the cost of purlins, rafters, trusses including cost and conveyance of all materials , labour charges , overheads and contractors profit etc., complete for finished item of work in all floors.
Supplying and fixing of 4" (101.6mm) multi floor trap with jali - UPVC/SWR pipe fittings as per site requirements with standard practice for all floors including cost and conveyance of all materials to site, labour charges , overheads & contractors profit etc., complete for finished item of work.
Supplying and fixing European Water Closet of 1st quality conforming to IS:2556-Part-2-1973 of white glazed with 'S' trap,supplying and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996 and 10 litres capacity single flush PVC low level cistern with internal components and fixed using required size of nails and screws, angle stop cock 12.70mm dia. first quality Indian make heavy duty, 12mm PVC connections with brass union nuts CP coated including cost and conveyance of all materials to site, overheads & contractors profit etc., complete for finished item of work for all floors.
Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 31.75mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work
Supplying and fixing NP soap dish heavy type of approved make ISI quality with NP screws etc., complete including cost and conveyance of all materials, labour charges for fixing , overheads & contractors profit for finished item of work in all floors
Supplying and fixing TV shape mirror with plastic frame of size 609.6mm x 457.2mm , plywood back with NP screws 1st quality including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work in all floors.
Supplying and fixing NP bib taps of size 12.70mm dia of Indian make heavy duty (long body) as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , overheads & contractors profit complete for finished item of work in all floors.
Supplying and fixing NP bib taps of size 12.70mm dia of Indian make heavy duty (short body) as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , overheads & contractors profit complete for finished item of work in all floors.
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 75mm dia
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 90mm dia
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 110mm dia
Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, overheads & contractors profit complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) 160mm dia
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.15.90mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.22.20mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.28.60mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.34.90mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.41.30mm OD pipe
Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2") for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, overheads & contractors profit complete for finished item of work at all floor levels.54.00mm OD pipe
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work. 20mm Nominal bore
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.25mm Nominal bore
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.40mm Nominal bore
Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , overheads & contractors profit complete for finished item of work.50mm Nominal bore
Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 31.75 mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work for all floors.
Supplying and fixing of 16mm to 20 mm thick polished marble slab partitioins of size 4' 0" x 2' 0" for urinals including full rounding the edges , fixing in position, polishing, including cost and conveyance of all materials and labour charges , overheads & contractors profit complete for finished item of work for all floors.
Providing and placing on terrace (at all floor levels) polyetheylene water storage tank with double layer approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet and outlets and over flow pipes but without fittings and base support for tanks including cost and conveyance of all materials and labour charges , overheads & contractors profit complete for finished item of work.
Construction of brick masonry support for GI pipe of size 304.80mm x 228.60mm x 228.60 mm in CM (1:8) prop including plastering and finishing with 12mm thick in CM (1:5) including cost and conveyance of all materials and all labour charges, overheads & contractors profit complete for finished item of work for all floors.
Supply and fixing of ISI 25mm outer dia (2.00 to 2.20)mm thickness, heavy grade with IS:9537 part 3 FRLS rigid PVC pipe (ISI marked) concealed in Roof Slabs with all required MS deep junction boxes and all accessories including and labour charges etc., complete. Makes: Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/Anchor/ Polyline/ Orbit/AKG/Beljin/Vasavi/DEC
Supply and Fixing of 25mm outer dia (1.60 to 1.80)mm thicknes medium grade with IS:9537 part 3 FRLS rigid P.V.C. pipe (ISI marked) concealed in wall with all required MS junction boxes and all accessories including masonary work for light, bell, fan, and separate plug point with hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges etc., complete. Makes: Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/Anchor/ Polyline/ Orbit/AKG/Beljin/Vasavi/DEC
Supply and Fixing of 25mm outer dia (1.60 to 1.80)mm thicknes medium grade with IS:9537 part 3 FRLS rigid Surface P.V.C. pipe (ISI marked) on wall with all required PVC Junction Boxes confirms to IS : 3419 and all accessories fixing on chromium plated metallic base saddles for light, bell, fan, and separate plug point with18 SWG sheet steel switch boxes duly finished with two coats of zinchromate red oxide and enamel paint for switch box with earthing terminal including all labour charges etc., complete. including all labour charges etc., complete. Makes: Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/Anchor/ Polyline/ Orbit/AKG/Beljin/Vasavi/DEC
Supply and erecting MS Galvanished fan hook box with hook in RCC slab including all Labour charges etc., complete.
Wiring with 2 runs of 22/0.3mm ( 1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable (ISI marked) in existing pipe with 6A Modular switch (ISI marked) with cover plate, Ceiling rose/BH/ SBH, including all labour charges etc., complete for Light, Bell, Fan and Exhaust Fan points etc., complete. (for Non Residential Building). Makes: Finolex / RR kabel / Havells/Finecab/ KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Wiring with 2 runs of 22/0.3mm ( 1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable (ISI marked) in existing pipe with 6A Modular switch (ISI marked) with cover plate, Ceiling rose/BH/ SBH, including all labour charges etc., complete for 2-way light and fan points/stair case light points etc., complete. (for Non Residential Building) Makes of wires:- Finolex/RR kabel/ Havells/ KEI/Polycab/ Gloster/Vguard/ HPL/GM/ Million/Goldmedal/Anchor. Makes of switches:- Legrand Myrius / Crabtree verona/L&T/ HPL/ Schneider Livia/GM (Zicono/Four Five)/C&S/Goldmedal (Curve)/Million Mway/Logus Platina/ Panasonic Vision/ Salzer S90 series/Anchor-Roma.
Supply and Fixing of 6 Amps modular type (ISI marked) switch, and 6 A 3/2 pin Modular type socket with cover plate on a common switch board including giving all connections and all labour charges etc., complete. Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/Precision(Series7)/Honeywell(Blenzepro)
Supply and fixing of 2 No of 6A (ISI marked) modular type switches with 2 No of 6A, 3/2 pin modular type sockets with cover plate on suitable hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges, giving all connections etc., complete for LABs & Computer Use. Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/Precision(Series7)/Honeywell(Blenzepro)
Supply and fixing of 3 No of 6A (ISI marked) modular type switches with 3 No of 6A, 3/2 pin modular type sockets with cover plate on suitable hot dip galvanized 20/18 SWG MS modular metal switch box with earthing terminal including all labour charges, giving all connections etc., complete for LABs & Computer Use. Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/Precision(Series7)/Honeywell(Blenzepro)
Supply and fixing of 16A/6A, 2 in one, modular type socket with 16A switch (ISI marked) modular type with cover plate on existing modular metal switch box including all labour charges, giving all connections etc., complete. Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/Precision(Series7)/Honeywell(Blenzepro)
Supply and Fixing of of 16A/6A, 2 in one, modular type power socket outlet with 16A switch (ISI marked) modular type and 3 No of 6A modular type sockets with 6A modular type (ISI marked) switch control with front cover plate on existing modular metal switch box including all labour charges, giving all connections etc., complete with following configurations 1) 16A Socket - 1 No 2) 16A Switch - 1 No 3) 6A socket - 3 No. 4) 6A switch - 3 No Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/ Precision(Series7)/Honeywell(Blenzepro)
Supply and Fixing of of 16A/6A, 2 in one, modular type power socket outlet with 16A switch (ISI marked) modular type and 1 No of 6A modular type sockets with 6A modular type (ISI marked) switch control with front cover plate on existing slot/groove in metal/PVC/wooden type modular work station/ Laboratory Table including all labour charges, giving all connections including earthing etc., complete with following configurations 1) 16A Socket - 1 No 2) 16A Switch - 1 No 3) 6A socket - 1 No. 4) 6A switch - 1 No Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/Precision(Series7)/Honeywell(Blenzepro)
Supply and run of 1 of 22 /0.3mm (1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing pipe for earth continuity including all labour charges etc., complete. Makes: Finolex / RR kabel / Havells/Finecab/ KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply and run of 3 of 22 /0.3mm (1.5 Sq.mm) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing pipe for mains continuity including all labour charges etc., complete. Makes: Finolex / RR kabel / Havells/Finecab/ KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply and run of 3 of 2.5 sq.mm (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing MS conduit pipe for individual ligting circuits including labour charges etc., complete as required for switch boards. Makes: Finolex / RR kabel / Havells/Finecab/ KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply and 3 runs of 4.0 sq mm (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing conduit pipe for run of mains including labour charges etc., complete as required including labour charges for 16A sockets. Makes: Finolex / RR kabel / Havells/Finecab/ KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply & run of 3 of 6.0 Sqmm (84/0.3mm) (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing MS conduit pipe for run of mains including labour charges etc. complete for AC points & SDB's etc as required. Makes: Finolex / RR kabel / Havells/Finecab/KEI/Polycab/ Gloster/ Goldmedal/ GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply and run of 5 of 6 Sq mm (phases, neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing MS conduit pipe for circuits including labour charges etc. complete as required for run of mains from Lighting panel board to TPN DB'S with pin type lugs and connections. [for LDBs] Makes: Finolex / RR kabel / Havells/Finecab/ KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply & run of 5 of 10.0 Sqmm (phases, neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in the existing conduict pipe for run of mains from Power panel board to TPN DB"s with pin type lugs and connections etc., complete. [for PDBs] Makes: Finolex / RR kabel / Havells/Finecab/KEI/Polycab/Gloster/ Goldmedal/ GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi)
Supply and Fixing of single phase DB in sheet steel enclosure as per IS 8623; IS 13032; IEC 61439-3 with metalic plug and socket with 1 No. 20/32A,10KA 'c' curve SPMCB control including labour charges and giving connections etc., complete concealed in wall. Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Crabtree Xpro classique-II/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Supply and fixing of TPN 6 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+18 Module) with provision to accommodate the ELCB incomer and suitable for single pole outgoing MCB's in sheet steel enclosure with 40A,10 KA breaking capacity 'c' curve 4 pole MCB as incomer and 18 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. (LIGHTING DB). Makes: Legrand (Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Supply and fixing of TPN 4 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+12 Module) with provision to accommodate the ELCB incomer and suitable for single pole outgoing MCB's in sheet steel enclosure with 63A, 10 KA breaking capacity 'c' curve 4 pole MCB as incomer and 12 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. (LIGHTING DB). Makes: Legrand (Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Supply and fixing of TPN 6 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+18 Module) with provision to accommodate the ELCB incomer and suitable for single pole outgoing MCB's in sheet steel enclosure with 63A, 10 KA breaking capacity 'c' curve 4 pole MCB as incomer and 18 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. (LIGHTING DB). Makes: Legrand (Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Supply and fixing of SPN 12 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3 suitable for single pole outgoing MCB's in sheet steel enclosure with 40A, 10 KA breaking capacity 'c' curve DP MCB as incomer and 10 No of 6 to 32A single pole, 10 KA breaking capacity 'c' curve MCBs as outgoings including making connections etc., complete concealed in wall. Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Supply and Fixing of 40/63A, 10 KA breaking capacity 'c' curve four pole MCB in sheet steel FP enclosure with IP 20 Protection etc., complete as per IS 8623; IS 13032; IEC 61439-3 including making connections etc., complete on wall. [for UPS Input/Output control etc.,] Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx / Lauritz Knudsen (Formerly L&T)-AU/Indo Asian-Opti pro/ HPL (Techno)/Anchor (Uno Plus)
Supply and fixing of VTPN DB, 8 way vertical type MCCB distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, suitable to accommodate MCCB as incomer and single/three pole MCBs as outgoings with 125A, 4 Pole MCCB adjustable, confirms to IEC 60947-2 and IS 13947-Part 1&2 having Breaking Capacity 25 KA with thermal magnetic release as incomer with 8 No of 40/63A, 10 KA TP MCBs 'c' curve as outgoing including making connections and labour charges etc., complete concealed in wall. Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/ Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus)
Supply and fixing of Cable adopter/Cable end box with cover suitable for 4-way TPN, IP-43 protection DBs including, massanory work etc., complete for concealed mounting. Makes: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange
Supply and fixing of Cable adopter/Cable end box with cover suitable for 6-way TPN, IP-43 protection DBs including, massanory work etc., complete for concealed mounting. Makes: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange
Supply and fixing of Cable adopter/Cable end box with cover suitable for 4-way/8-way VTPN MCCB DBs with IP-43 protection including, massanory work etc., complete for concealed mounting. Makes: Legrand(Ekinox 3) / Schneider-Acti9/Hager -Novello+/ Seimens/L&T-Newrange
Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C.Chamber of 400m x 400m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)
Providing independent earthing for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 40mm dia G.I Pipe of 2.5 mtr length connected with reducer providing G.I funnel with wiremesh as per National Electric Code including C.C.Chamber of size 400m x 400m x 400mm covered with R.C.C. Slab filling with salt and charcoal giving earth connection from electrode with Copper strip of 25mm x 5mm x 200mm length to be bolted with nut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to Copper strip with all accessories and labour charges complete as per IS specification 732/1982 (Part II).
Providing independent earthling by excavating a trench to a depth of 2.5 M in all soils, as per size specified in the Data, using 100mm dia Heavy gauge Flange C.I (Cast iron) pipe of 2.5 Mtrs length with necessary accessories duly providing staggered holes including filling with equal proportion of Salt and Charcoal in layers and all labour charges etc., complete.
Supply and Run of No.8 SWG G.I wire including cost of all accessories and labour charges etc., complete.
Supply and Run of 25mm x 3mm G.I Strip including cost of all accessories and labour charges etc., complete.
Supply and Run of 25mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete.
Supply and Run of 50mm x 6mm G.I Strip including cost of all accessories and labour charges etc., complete
Supply and Run of 25mm x 3mm copper strip including cost of all accessories and labour charges etc., complete.
Supply and Fixing of 20-24W, not less than 1100mm length LED batten light with extruded alluminium / CRCA housing and polycarbonate cover, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV, THD<15%, with high power LEDs having efficacy of ≥ 120 lumens / watt with inbuilt and replacable driver with earth connection brought outside and frosted cover CCT: 3000K - 5700K, minimum CRI>70 etc., complete including fixing on wall / Ceiling with PVC/TW round blocks with all accessories including giving connections and all labour charges etc., complete with 5 years warranty. Make: a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/ Everlight
Supply and Fixing of heavy duty 18 W LED Down lighter, suitable for recessed/surface mounting made of diecast alluminium body with powder coating, acrylic diffuser with Driver as per IS: 15885 (Part 2/ Sec 13) : 2012 , operating voltage range of 150 to 265 Volts AC, P.F > 0.9, Surge protection: 2KV, THD<10% with high power LED's having efficacy of > 120 lumens / watt, CCT: 3000K - 5700K, minimum CRI > 70, luminaire performance complies to IS 10322 (Part 5 / Sec-3) etc., complete including fixing in the ceiling with recessed/surface mounting, cost of all accessories and giving connections etc., complete with 5 years warranty. Make: a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready/ FortuneArrt/ Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/Everligh
Supply, transportation and fixing of 36W Recessed/Surface mounting 2' x 2' (600x 600 mm) LED luminaire made of CRCA sheet housing with powder coated with acrylic diffuser, Constant current Driver as per IS: 15885 (Part 2/ Sec 13) : 2012 , With System lumen output ≥ 3200lm operating voltage range of 150 to 265 Volts AC, P.F > 0.9, Surge protection: 2KV, THD<10%, with high power LED's having efficacy of > 120 lumens / watt, CCT: 3000K - 5700K, minimum CRI>70 etc., complete including fixing in the ceiling with recessed/surface mounting, cost of all accessories and giving connections etc., complete with 5 years warranty. a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton / Wipro / Bajaj/ Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready / FortuneArrt// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/Everlight
Supply and Fixing of batten holder/angle holder on existing block with 5W LED Lamp with input voltage 90 to 300V, Colour temparature 3000k - 6500k, Beam angle 170 - 220 degrees, B22 base and all labour charges etc., complete. In lieu of ceiling rose. Makes:GMGHome/GoldMedalOlive/MillionZoom/GreatwhiteOmega/Koncept/Vimalopel/ Anchor/Vihan/CPL/ Havells Reo/Elleys
Supply and fixing of call bell on 6"x8" decolam block including giving connections, cost of all accessories and labour charges etc., complete. Makes:GMGHome/GoldMedalOlive/MillionZoom/GreatwhiteOmega/Koncept/Vimalopel/ Anchor/Vihan/CPL/ Havells Reo/Elleys
Supply and fixing of buzzer on 4"x4" decolam block including giving connections, cost of all accessories and labour charges etc., complete. Makes:GMGHome/GoldMedalOlive/MillionZoom/GreatwhiteOmega/Koncept/Vimalopel/ Anchor/Vihan/CPL/ Havells Reo/Elleys
Supply and Transportation of 48" (1200mm) Sweep 5 star rated Ceiling Fan , with double ball bearings, air delivery more than 200 cubic meter/min but without Regulator. Makes: Crompton (HS Plus/HS) / Havells (ES PLUS/SS390ES) /Orient Energy Star/ Halonix(Zephyr)/Polycab(Synergy 50 ISI) / G.M. (Air Wave Premium)/Bajaj-Edge/Arcline (Glacier)
Supply and fixing of Modular type 2- Module, Electronic fan regulator hum free step type socket size in the existing switch board. Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/ Precision(Series7)/ Honeywell(Blenzepro)
Labour charges for fixing of ceiling fan including transportation and giving connections with 23/0060 size, 3 core round flexible copper wire leads Makes: Finolex / Polycab / Havells / V-Guard / Gold Medal / GM / Million / Vimal /Airson/CRI/ Tamra/ ollvin/Avocab
Supply and erecting 19/20mm steel tube down rod of 0.6 mt length with bolts & nuts duly painted with matching colour of fan complete
Supply and erecting 19/20mm steel tube down rod of 0.75 mt length with bolts & nuts duly painted with matching colour of fan complete
Supply and Transportation of 12" (300mm) Light duty exhaust fan with metalic blades and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DSP / Orient hill air/Halonix /Polycab/G.M. (Xenix)/Goldmedal (Rapido-12)
Supply and Transportation of 12" (300mm) ISI, 900 RPM Heavy duty exhaust fan with metallic blades with Mark. Makes: Crompton / Almounard / Havells Ventil Air-DB
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete
Supply and fixing of louver shutter suitable for 12" Exhaust fan including all labour charges etc complete with connections and colouring matching to the wall with enamel paint.
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt 3.5 core, 35 Sq.mm
Supply and transportation of following XLPE insulated, 1100V grade armoured alluminium cable as per specification confirming to IS:7098 (Part-I)/1554-I Makes: Torent / Universal / Unicab / Havells / Finecab / KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt 3.5 core, 50 Sq.mm
Earth work excavation of Trench in hard ground soil, laying of U.G cables upto 50 Sq,mm on sand cushion covering the cable with bricks and back filling of Trench duly providing route indicator embedded in C.C including cost and conveyance of materials and labour charges etc., complete.
Labour charges for run of U.G cables upto 50 sq.mm on wall with necessary fixing arrangments such as saddles, clamps etc., as directed by department including cost and conveyance of all materials etc., complete.
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI 3.5 core, 35 Sq.mm
Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. Makes:Dowels/Comet/SMI 3.5 core, 50 Sq.mm
Supply,transporatation & installation of following sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/Wall with suspenders etc., complete 300mm X 50mm X 1.6mm size
Supply and laying of 2 pair telephone wire 0.5mm copper in the existing metallic/non metallic conduit pipe with connections etc.,complete for telephone wire. Makes: Finolex / Delton / Surabi / Polycab
Supply and laying of 10 pair telephone wire 0.5mm copper in the existing metallic/non metallic conduit pipe with connections etc.,completeTelephone wire Makes: Finolex / Delton / Surabi / Polycab
Supply and fixing of 2 Line telephone jack type socket modular type with front and back plate in MS box with screws and connections etc. Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/ Goldmedal(GIFA)/Million (M-VEE)/Anchor(RomaPLUS)/ Precision(Series7)/ Honeywell(Blenzepro)
Supply and Installation of 10 Pair Telephone distribution box with back mount frame, krone connector, powder coated metal body with lock and key arrangement. Makes: Krone or equivalent make.
Supply, laying, testing and commissioning of 4-pair, Cat-6 Solid (Third party ETL Intertek tested 600 MHZ above) to support 1Gbps with Cross (+) filler pair seperator & PVC sheath 23 AWG, UTP Cable , Meets or exceeds ANSI/TIA- 568-C.2 and UL Listed &RoHS Compliant in the existing raceways /pvc conduits including making connections to information outlets and patch panels with ferruling at both ends for identifiation with necessary tools for punching stripping crimping and testing required etc., complete Makes: Systimax /Panduit/ Siemond/ Legrand
Supply and Fixing installation testing and commisioning of1no of Cat-6 Tooless built-in crimping mechanism Information Outlet with Dust Cover Exceed ANSI/TIA-568-C.2 and ISO/IEC 11801 standards with 1module face plate for Category 6 component performance & Compatible to T568A,T568B wiring pattern and UL-940V0 Rated Plastic &RoHS Compliant. Makes: Systimax /Panduit/ Siemond/ Legrand
Supply and Fixing, Installation, Testing and Comissioning of Rack mounted 19", Cat 6 UTP,1.5-1.6 MM CRS Chasis, powder coated Modular Patch Panels (upgradable to intelligent panels with use of sensor strips) with collapsible shutters on jacks to support latest ammendments of TIA / EIA Cat 6 Specifications in Existing Communication Rack along with necessory connections of Cat 6 UTP Cables, With Rear Cable management trays and clamps. 1) 24 Ports Patch Panels Makes: Systimax /Panduit/ Siemond/ Legrand
Supply and Fixing, Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 1) 6 U(44 mm ) wall mounted Make: APW/HCL/Valrack/Netrack
Supply & Fixing of Cisco small business 24 port Gigabit POE Managed Switch , Makes: Cisco Model: CBS -350-28PP or equivalent in Juniper/Extreme
Supply, Transportation, Installation, Testing and Commissioning of the following Inverter model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation. 1.5 TR 5 star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5. Makes: Mitsubishi / O General /Toshiba (prevailing models in the market)
Supply, Transportation, Installation, Testing and Commissioning of the following Inverter model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation. 2.0/2.2 TR 5 star capable of delivering 24000 BTU/hr and above with operating on refrigerant R-410A / R-32. Makes: Mitsubishi /O General /Toshiba (prevailing models in the market
Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of split AC unit.
Providing 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for split/Casseete Air- Conditioner including foaming etc., complete. Make: Copper:Totaline /Nippon /Mandev/Nitrile Insulation: Kflex/ Totaline /Armafle 1/2" x 1/4"
Providing 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for split/Casseete Air- Conditioner including foaming etc., complete. Make: Copper:Totaline /Nippon /Mandev/Nitrile Insulation: Kflex/ Totaline /Armafle 3/4" x 3/8"
Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200V to 250V rated for 4 KVA maximum load and time delay model with 16A, 3-way connector/ socket for output and with 3 core flexible chord and 3 pin 6/16A plug top for input suitable for Air-conditioner for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete. Makes: V-Guard / Real Guard / Uni Stab / ITL.
Supply and erecting fully automatic line voltage stabilizer for operation on input voltage 200V to 250V rated for 5 KVA maximum load and time delay model with 16A, 3-way connector/ socket for output and with 3 core flexible chord and 3 pin 6/16A plug top for input suitable for Air-conditioner for continuous operation including cost and conveyance of all mateials and all labour charges etc., complete. Makes: V-Guard / Real Guard / Uni Stab / ITL.
Supply, Installation, Testing and Commissioning of Electric Traction Passenger Lift of Makes: Kone/Otis /Schindler /Mitsubishi /Johnson/ThyssenKrupp/Fujitec with • Rated capacity :- 13 Passenger/884Kg • Floors :- G+1 floor (2Stops/2 Landings) • Travel :- 3 to 4.2 mtrs. • Location of Lift Machine:-with Machine Room • Rated speed :- 1.0/1.25mps VS • Doors type :- COPO/TOPO Doors with frame having clear opening of 900/1000 mm wide x 2000 mm high made from SS 304 grade sheet of 1.5mm, thick in hairline finish for car and all landing doors with SS door architraves/ frames • Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audiovisual alarm, VAS in Telugu & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor • LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings • Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor /control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection classARD complete with necessary SMF VRLA batteries • Fireman controller having fireman switch at fire Landing, • Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work • Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. General: - Job includes entire procedure of obtaining all necessary erection permissions & “License to Work the Lift" from Electrical Inspector (Lifts) with submission to the Engineer in Charge. Warrantee: - Job covers two years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule.
Supply Installation Testing And commissioning of 58.5kVA at 0.8 pf 415V 50Hz 3-Ø CPCB IV+ DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled. Alternator 1. 1500 RPM, 1P or 3P, Brushless type, screen protected, revolving field, Self-excited alternator conforming to IS/IEC 60034-1 IP23, with standard Alternator Protection (over voltage, over speed & Under voltage) 2. A reliable long life with superior class 'H' insulation with temperature rise to Class H Diesel Engine: Engine: Engine should comprise of Silencer, Electronic governor from >25 KVA & above, suitable rating battery , Battery charging alternator, battery charger , Inbuilt Fuel tank with fuel pipe, AVM pads , Control panel with 3P MCCB of suitable rating with short circuit protections (25kA,36kA, 50kA) with microprocessor based controller indicating genset parameters ( i.e. volt, amps, KWH, KVAR, Hrs etc.), The diesel engine shall be capable of providing 10% overload for 1 Hr for every 11 Hrs of continuous running at full load. The DG set shall be supplied as per OEM specifications and shall be tested at site along with below. 1. CRDI Engine >25 KVA DG set 2. Water cooled Radiator coupled to engine 3. Dry type air cleaner with service indicator 4. First fill of lube oil, Coolant & first fill of Diesel 5. Electrical starter motor with soft start System 6. Battery charging alternator 7. Remote Monitor system >58.5 KVA & Above 8. 2 years / 5000 Hrs Warranty from commissioning or 30 month form supply. 9. Emission control system - EGR & (DOC, SCR for >75 KVA DG set) 10.10 Mtrs Exhaust pipe from Silencer Genset Controller: 1. Microprocessor based genset monitoring, metering and control system with full graphics LCD display for easy front panel access. 2. AMF relay, manual and remote start / stop modes for 1-ph & 3-ph gensets 3. Backlit and full graphics display with power saving feature 4. Engine parameter monitoring -Lube oil pressure, Engine coolant temperature, Fuel level, Battery voltage, Engine running hours 5. AC Alternator parameter monitoring -Voltage L-N & L_L, Current, kW, kVA (Phase & Total), Frequency, kWH, PF 6. Genset Protection: Engine: Low lube oil pressure, High coolant temperature, Battery High/Low Volts, Fail to Start, Sensor failure, Low fuel level, Overspeed AC Alternator: Over/Under Voltage, Over/Under, Frequency, Loss of AC sensing, Over frequency, Over Current, kW Overload, Unbalancing load 7. Maintenance notification based on Engine Run Hour & due date 8.Communication: USB port, RS485, CAN 9.30-50 Event logs Acoustic Enclosure: 1. Specially designed to meet stringent MOEF/CPCB IV+ norms 2. Weatherproof, powder coated Acoustic enclosure for DG set for sound attenuation fabricated from 1.2 mm / 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.2mm /1.6 mm CRCA sheet and filled with PU Foam/Rockwood for Fire retardant acoustic and for better safety 3. Designed to operate in extreme climatic conditions in temperatures ranging from -10 deg to 55 deg without any external aid 4. Fabricated base frame with AVM pads. 5. Noise level is less than 75 db (A) at a distance of 1 Mtrs as per CPCB norms, complete in all respect. following capacity 58.5kVA at 0.8 pf 415V 50Hz 3-Ø
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ Naturopathy and Yoga College VIMS VSP.xlsx
TENDER_DOCUMENT • 0.13 MB
TD-2-9-Naturopathy and Yoga College VIMS VSP.docx
TENDER_DOCUMENT • 0.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].