Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹4.4 Cr+₹27.0 L (6.58%)Rejected-AOC 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | ₹4.4 Cr+₹27.0 L (6.58%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹4.4 Cr+₹32.4 L (7.89%)Rejected-Finance | ₹4.4 Cr+₹32.4 L (7.89%) | L3 | Rejected-Finance Quoted Highest amount |
Tender Value
Refer Docs
EMD Value
₹9 L
Closing Date
14 Mar 2022, 2:00 pmClosed
SE,KHEC,PWD
SUPERINTENDING ENGINEER (P.W.D) Kolkata Health Electrical Circle KIT Annex Building, 5th FLOOR, KOLKATA 700073
Construction of Administrative cun Academic Building for West Bengal University of Health Science at Salt Lake (Electrical Works)---SITC of Sub Station and allied works.
2022_WBPWD_365291_1
WBPWD/SEKHEC/KNHED/NIQ05/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
West Bengal University Health Science Salt Lake
Please refer Tender documents.
6 documents required · 6 mandatory
₹9 L
Office of the SE,KHEC,PWD
8 Jun 2022
10 Feb 2022
16 Mar 2022
11 Feb 2022
14 Mar 2022
23 Feb 2022
17 Feb 2022
Amount
SUB-HEAD I : SITC OF VCB PANEL, TRANSFORMER & LT PANEL
Supply & Delivery of Indoor-type, floor mounted,metal clad,single tier, totally enclosed and fully interlocked,fully compartmentalized,free standing, 11 kV VCB Panel with 3 Nos 800 A VCBs (1 Incomer + 2 Outgoing) as per IS 13188, as ammended upto date and as per detail specification and approved make attached ( uploaded in the specification section) , suitable for use on 11 KV,3 Phase,50 Hz AC supply to energise 2 nos 1000 KVA Dry Type Transformers .
Installation, Testing & Commissioning of the above 11 kV VCB Panel with PT & all the accessories, incl. carriage, by placing in position, assembling, lining up, levelling and checking all instruments, relays, correctly set according to requirement.
Supply & Delivery 1000 KVA, 3 Phase , Cast Resin Dry Type Transfirmer suitable for operation in 11KV/415V, ,50Hz power supply, having cable end box in the HV & LV sides and all accessories and conforming to IS 11171-1985 & IS - 2026 with latest modification (if any) & CBIP Specification and as per detail specification and approved make attached ( uploaded in the specification section)
Installation, Testing & commissioning of above11 KV/ 415 volt, 1000 KVA distribution transformer incl. carriage to the substation building within a lead of 30mtr by placing in position and fixing after leveling fitting all components, connecting, checking & set of all instrument, relays according to requirement as instructed by the EIC incl. S&F base channels etc.
SITC of floor mounted Indoor type extensible cubical type LT Panel,fabricated by CPRI approved panel maker as per size, design & drawing to be approved by EIC and conforming to relevant IS with latest modification and as per detail specification and approve make attached ( uploaded in the specification section)[LT MAIN PANEL IN THE SUBSTATION]
Making testing arrangement and submitting the test report for high voltage testing of specified voltage incl. checking & testing of all HT / LT equipments by authorized firm of Directorate of Electricity & commissioning the installation after obtaining the Approval of Directorate of Electricity.The scope shall be also included the necessary approval from Authority also.
SUB HEAD II - HT/ LT CABLING IN SUBSTATION
Supplying and laying of 1 No. 11KV (E/UE) Grade XLPE Aluminium conductor, PVC sheathed, armoured cable confirming to IS 7098 with latest ammenment of following size in the existing Masonary Open Duct as required as per approved make uploaded herewith.[ From Supplier HT Gear to Consumer HT Gear and to Transformer].
a) 3 Core x 300 Sq.mm
b) 3 Core x 240 Sq.mm
Making heatshrinkable joints to the ends of the following XLPE HT cable at the transformer end as well as at the VCB ends supplying with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC
a) 3 Core x 300 Sq.mm
b) 3 Core x 240 Sq.mm
Supplying and Laying of following size PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing Masonary Open Duct. [ From TR & DG set to main panel].
a) 4 Core x 400 sq.mm
Supplying and making end termination with Brass compression gland and aluminium lugs for the following sizes of PVC insulated and PVC sheathed aluminium conductor cable of 1.1 KV Grade as required
a) 3.5 Core x 400 sq.mm.
Supply & Drawing 1.1 KV Grade 7 Core 1.5 sq.mm PVC Armoured Copper Cable from Transformer WT relay to VCB WT relay for Power & Control Supply as per direction of EIC
SUB HEAD III - EARTHING
Earthing with Copper plates per detail specification attached ( uploaded in the specification section) [ FOR TRANSFORMER NEUTRAL AND DG SET EARTHING ]
S& laying 240 sq. mm. single core multistrand PVC insulated flexible Cu wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to transformer point as required (for Transformer /Generator neutral earthing) including Socketing both sides by Cu Socket.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Insulating the 65 x 8 mm M.S. flat incl. S&F black heat shrink PVC sleeves etc. The PVC tube sleeve to be inserted on the GI flat and heat shrinked by heating apparatus by skilled technician carefully without damaging the PVC sleeve as per direction of the EIC (for transformer neutral earth bus bar).
Providing and fixing 25mm X 5mm copper strip in 40mm dia GI pipe from earth electrode including connection with brass nut, bolt, spring, washer, excavation and re-filling etc as reqd.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply & fixing 75x45 mm "C" channel having length of 2 mtr. each channel incl. nuts, bolts and washer etc.
S & F special type earth electrode clamp made of GI flat with nuts, bolts,, washer etc. suitable for 80 mm dia GI pipe earth.
SUB HEAD - IV - SAFETY EQUIPMENT
Providing & fixing danger plates made of mild steel at least 2mm thick & vitreous enameled white on both sides & with inscription in signal red colour on front side as required.
a) High Voltage - size 250mm x 200mm
b) Medium Voltage - size 200mm x 150mm
Providing and fixing carbon dioxide (CO2) type fire extinguishers conforming to IS 15222-2002 and cylinders fully charged of following capacity(4.5 Kg ) [Make - Fire Shield/ Ceasefire]
Supply and fixing of foam fire extinguishers conforming to IS 4989-2006, Portable type 9 lit capacity hanged on wall with bracket complete as required. [Make - Fire Shield/ Ceasefire]
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (approx. Front area 1.20 sq.mt.)
Providing of set of 4 nos. 9.5 litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and written with white paint 'FIRE' and mounted on MS angle iron frame with bracket and suitable base of appropriate size & capacity I/c filling sand etc.
Providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 13115-1991.
Supply and fixing shock treatment chart duly mounted on a wooden frame with 5mm thick glass as reqd. (approximate front area 1.20 sq.metre).
Providing of rubber mat 2 mtrs Length x 1 m. wide and 12mm thick to withstand 15 KV dielectric strength as per IS 15652-2006.
Providing of rubber mat 2 mtrs Length x 1 m. wide and 6mm thick to with stand 3.3 KV dielectric strength as per IS 15652-2006.
S&F 11kv grade Rubber Hand Gloves.
S/F of 860 mm wide and 8 mm thick M.S checker plate including painting for covering the trench.
SUB HEAD - V - SITC OF LC SYSTEM IN THE SUB-STATION BUILDING
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet / Roof / Wall with GI Saddles1100 mm apart incl. mending good the damages to building works
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart including mending good damages to building work
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:
(a) Length upto 0.5 Mtr
(b) Length above 0.5 Mtr
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS [ For Soft Soil ]
Earthing with 50 mm dia GI pipe ( Tata Medium ) 3.64 mm thick x 3.04 Mts long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt & charcoal or coke for plate / pipe electrode .
SUB-HEAD VI : EXECUTION OF MISCLENEOUS WORKS
Making masonary cable trench after cutting all sorts of soil. The inside mearsurment of trench 900 mm clear width x 900 mm clear depth by providing 250 mm thick brick work with 1st class brick cement mortorr (1:4) on both sides and bottom of the trench consisting with 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling 15mm thick (1:4) cement plaster to inside wall & 3mm thick neat cement finish.
Supply, fabrication and placing/fixing MS checkered plate made of 6mm thick incl 30mm x 30mm x 6mm MS angle iron structure welded by fixing insert plates at 4 sides in cable trench top with 2 nos 3/8" TMT handle rod incl gas cutting, grinding & drilling with one coat of red laid primer and one coats of synthetic enamel paint as per direction of EIC.
Core cutting of 125mm thick RCC slab by suitable core cutting machine for passing necessary vertical run of Electrical Bus duct/ cables/ cable tray/ protection pipes/ earthing strip etc including mending good the damages as per direction of the EIC.
Cutting floor/ brick wall by suitable tools for passing electrical cables/ cable tray/ protection pipes/ earthing strip etc including mending the damages as per direction of the EIC.
SUB-HEAD VII : SITC OF LT PANEL IN THE BUILDING
SITC of floor mounted indoor type expandable cubical MV Switchboard in suitable enclosure having Short Circuit withstand capacity of 31 MVA (i.e, 45 KA) for one second, fabricated by CPRI Approved panel builder as per enclosed specification.
SUB-HEAD VIII : SITC OF RISING MAIN
Supplying, installing on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains foruse on 3 phase 4 wire 415 volts, 50Hz A.C. supply withenclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required as per item no 3.8 of DSR 2018.
800 A Isc = 50kA for 1 second
Supplying, installing, testing and commissioning of following capacity tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with MCCB of following capacity incld. all accessories earthing etc. as required.
SITC of 800A, 50 KA, 4 P, Microprocessor Based MCCB with OL / SC Release with communicanle port of approved make.
SUB-HEAD IX : INTERNAL E.I. WORK OF SUB- STATION AND OTHERS :
Supplying and fixing double door 8 way Vertical TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING- Supplying and fixing 415 V, 160A Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection -1No.(Make:Legrand) OUTGOING- Supplying and fixing 240V 63A TP MCB of Breaking capacity 10kA & C characteristics on 1din rail of existing DBs and necessary connection-8 nos. .(Make: Legrand)
S & Drawing following sizes PVC insulated FRLS Cu.wire (Make - Finolex/Havells/RR Kabel) in 20 mm dia PVC rigid conduit pipe on wall complete with all accessories incl. making connections as to G.S. :-
2 x 6 sq.mm + 1 x 4 sq.mm. for PDB to BDB.
Finishing the end of following sizes copper wire end with dowells solderless socket by crimping method as per GS as follows:-
4 x 10 & 2 x 6 mm² copper wire
2 x 6 & 1 x 4 mm² copper wire
S/F Double Door 4-Way TPN MCB PDB in S.S. enclosure with IP-42/43 protection flushed in wall consisting with 1 No., 63A. 4-Pole Isolator 12 nos., 32 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necsy.earthing attachment. (Legrand, Cat No. 6077 15)
S/F Double Door 2+10 way (Make -LEGRAND, Cat No.6077 11) SPN MCB DB in S.S. enclosure with IP-42/43 protection flushed in wall consisting with 1 No., 40 A DP Isolator, 8 nos., 6/16 A. SP MCB as outgoing, complete with DIN Channel, Neutral Bar, Earth Bar and other accessories & connection with suitable size of Cu. wire with proper socketing incl. necy.earthing attachment.
Distribution wiring in 1.1 KV grade 3x1.5 sqmm single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Finolex/Havells/RR Kabel make) partly in 20mm size PVC rigid conduit 'FR' (Precision make) and in 19mm bore, 3mm thick polythene pipe to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board to be embedded & flushed in wall incl. mending good damages to original finish complete with 3 nos. “Ph, N & E” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. (PVC rigid conduit only for ceiling and horizontal run and Vertical run Concealed) [Av. Run 9 Mtrs.]
S/F 240V, 6A, 5-Pin Universal Key type Plug Base without Top and Piano Key type switch (both Anchor) on Board and Necy. Interconnections as per direction of EIC.
S/F Plug Board having 240V 6-pin 16A plug socket & 1 Nos. 16A piano key type switch and 3 nos. 240V, 6A, 5-Pin plug socket & 3 nos. 6A Piano Key switch and 1 no. Indicator (all Anchor make)
S & F 250V power plug board with 1 no. 3 pin 16 Amps plug socket with 16 Amps piano key type switch (Anchor make) on sheet steel metal box with bakelite top cover as to GS.
S/F Plug Board having 2 Nos. 240V, 5-pin 6A plug socket with 2 Nos. 6A piano key type switch (Anchor)
S & Drawing following sizes PVC insulated FRLS Cu.wire (Make - Finolex/Havells/RR Kabel/Gloster/Polycab) in 20 mm dia PVC rigid conduit pipe on wall complete with all accessories incl. making connections as to G.S. :-
3 x 1.5 mm² for separate plug boards
2 x 2.5 sq.mm.+ 1 x 1.5 sq.mm. for Power Plug.
2 x 4 & 1 x 2.5 mm² from TPN PBDB to AC points.
2 x 6 sq.mm + 1 x 4 sq.mm. for PDB to BDB.
4 x 10 mm² & 2 x 6 mm² for sub-main wiring from VTPN to TPN PDB.
Finishing the end of following sizes copper wire end with dowells solderless socket by crimping method as per GS as follows:-
4 x 10 & 2 x 6 mm² copper wire
2 x 6 & 1 x 4 mm² copper wire
2 x 4 & 1 x 2.5 mm² copper wire
2 x 2.5 & 1 x 1.5 mm² copper wire
Supply & Fixing 230 V., 18" (450mm) 4 (four) Blades Industrial type Air-Circulator Pedestal Fan complete with all accessories such as Regulator, Cord and 15 Amp. 3-pin Top (Make - E.P.C. Electrical Pvt. Ltd., Heavy Duty)
Supply & Fixing 230 V., 18" (450mm) 4 (four) Blades Industrial type Bracket Fan complete with all accessories with S&F sequential timer (Approved Make) to be grouted on wall inclu. Making necesy. Connection as per direction of the EIC (Make - E.P.C. Electrical Pvt. Ltd., Heavy Duty)
S & F 240 V A.C. Exhaust Fan (EPC Electrical Pvt. Ltd. - Heavy Duty) incl. Cutting hole on wall with Nuts, Bolts, washers etc. on wall and mending good the damages to original finish as per direction of the EIC for following sizes:-
300 mm (12") sweep 1420 RPM
225 mm (9") sweep 1370 RPM
S&F of "L" shape Cowl made of G.I sheet of size 300x300mm having length 600mm with 4 nos 20x3mm MS flat support and S&F of wire mess at the ends of the said cowl with nuts, bolts etc as reqd. for following sizes exhaust fans:-
300 mm (12") sweep
225 mm (9") sweep
S&F of 230V, 48" (1200 mm) Sweep, A.C. Ceiling Fan with minimum air delivery 210 cu.m/min, speed 370 rpm, power input 52 watts without Regulator, incl. 1.6-2.5 micro-farad burst-proof P2 capacitor, Down Rod, Canopy, Fan Blades with all complete accessories and engraving & Painting the Departmental Number upto 15 digit on Fan Body and electrical connection complete in all respect. ( Make: USHA Striker Plus / Crompton Greaves - HS+/HB+ / Orient Energy Star)
S/F 250V, 100 Watt Electronic step type Fan Regulator on existing sheet metal switch board after making housing for regulator by cutting bsakelite top cover incl. making necessary connections.( Make- Anchor)
S/F MS 2-piece type RC fan clamp as per GS.
S&F of 240V, LED tube light fittings suspended 25 cm. below the ceiling by 2 nos. 20mm. Dia. E.I. Conduit support with, MS 'L' clamp and necy. Electrical connection by 2 x1.5 mm² PVC insulated Cu. Wire & painting as follows:-
Single Fittings (Philips: TMC-501 P1XTLED or eqivalent of it in all respect of WIPRO/ Crompton:) with 1X 18/20 watt LED tube (Philips: Master LED 865 2100 lumen / P8 Cat No : 929012011787)
Twin Fittings (Philips: TMC-501 P2XTLEDor eqivalent of it in all respect of WIPRO/ Crompton ) with 2X 18/20 watt LED tube (Philips: Master LED 865 2100 lumen / P8 Cat No : 929012011787)
S&F of surface mounted 10W LED downlight luminaire. (Philips)
SUB-HEAD X : SITC OF CABLES FROM SUB-STATION TO BUILDING
Supplying & Delivery of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured) conforming to IS: 7098 / 1988 with its latest amendment of following size.
a. 4 Core 300 Sq. mm
b. 4 Core 240 Sq. Mm
c. 4 Core 35 Sq. Mm
d. 4 Core 25 Sq. Mm
Laying of 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable (Armoured) of following size in the existing Masonary trench as required and as per GS.
a. 4 Core 300 Sq. mm
b. 4 Core 240 Sq. Mm
Laying of 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable (Armoured) of following size in the wall /floor and mending the good damage as per required .
a) 4 Core 35 Sq. Mm
b) 4 Core 25 Sq. Mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
a. 4 Core 300 mm² Al cable
b. 4 Core 240 mm² Al cable
c. 4 Core 35 mm² Al cable
d. 4 Core 25 mm² Al cable
S&F compression type gland complete with Brass Gland, Rubber Rings for dust & moistureproof entry of cables incl. finishing the ends by crimping method incl. S & Fixing Dowells solderless socket, tapes and terminating materials as follows;-
a. 4 Core 300 mm² Al cable
b. 4 Core 240 mm² Al cable
c. 4 Core 35 mm² Al cable
d. 4 Core 25 mm² Al cable
S&F of MS Channel/ angle iron structure made of (80x80x80x6)mm MS C Channel / (50x50x6) mm MS angle 50mmx6mm MS flat, nut, bolt, washer etc to provide overhead supporting arrangement above different LT panels incl painting as to GS for following :
a. 80 mm x 40 mm x 40 mm x 6 mm thick MS channel
b. 50 mm x 50 mm x 6 mm MS angle
c. 50 mm x 6 mm MS flat
Supply & Installation of Electro Zinc Galvanised Hot Dip Galvanised (105 / 400 mm outdoor type) Wiremesh cable Tray in accordance with standard BSEN 12329-2000 with all mounting accessories. Fire test certification should be published in accordance with the E30/E90 standard. Electrical continuity across a coupling should be demonstrated by means of a published test method and result. [MAKE: LEGRAND CABLOFIL /OBO]
S&F of suitable angle support for holding the cable by horizontally run. The above clamp made of 50 x 50 x 6 mm. angle iron with half round type MS clamp for rigidly holding the cable. The above clamp made of 40 x 3mm. thick flat iron patty incl. nuts, bolts & washers etc. The length of angle support as required for 4 Core 400/300/240/185 mm² XLPE, Ar./Al. cable. The total iron strucutre will be hot-dip Galvanized .The structure will be fixied on wall by proper grouting inside the wall and mending good the damages as per direction of the EIC.
For 4 nos Cable run
For 3 nos Cable run
For 2 nos Cable run
S& laying 250 mm (10") NB (ISI Heavy) HDPE pipe for Cable protection with necy. fittings & jointing materials as required.
S& laying 150 mm (6") NB (ISI Heavy) HDPE pipe for Cable protection with necy. fittings & jointing materials as required.
SUB-HEAD XI : COMPOUND ILLUMINATION WORK :
Design, Manufacture, testing, supply and commissioning of Double door outdoor type Distribution Feeder Pillar box conforming to Indian Standard IS : 5039-1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable for short circuit fault of 31 MVA at 415 Volts, fabricated as per size, design & drawing to be approved by EIC as per detail specification and approved make attached ( uploaded in the specification section)
Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole ( Make : Bajaj, Philips, Valmont, CG, Transrail/Bansal / Utkarsha / Skeeper ).
9 Mtr Long
7 Mtr Long
Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth.
9 Mtr Long
7 Mtr Long
SITC of single dip galvanized steel overhang bracket ( Swan Neck Type ) at the top of the pole having 0.5 M / 1 Mtr length complete with all fixing arrangements as required including painting
Four Arm ( 1 Mtr )
Single Arm ( 0.5 Mtr )
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size.
4 Core10 Sq. mm
2 Core6 Sq. mm
Laying of one No. cable above in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
4 Core10 Sq. mm
2 Core6 Sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc.and making connection to switch, BDB and BBC etc.
4 Core10 Sq. mm
2 Core6 Sq. mm
S&F of 90 Watt LED street light ( IP 66 ), aerodynamically designed with better thermal management with separate lamp housing with heat resistant toughened glass & control gear housing and potted driver provided with surge protection suitable for mounting on 50 mm dia (OD) with Arm bracket [ Make - Philips, Type - BRP 410 LED 90CLW HE MR PC S2 PSU GR or equivalent of it in all respect for Crompton / Wipro ].
S&F of 120 Watt LED street light ( IP 66 ), aerodynamically designed with better thermal management with separate lamp housing with heat resistant toughened glass & control gear housing and potted driver provided with surge protection suitable for mounting on 50 mm dia (OD) existing Arm bracket [Make: Philips, Type - BRP 410 LED 110 CW HE MR FG S2 PSU GR or Equivalent in all respect for Crompton/ Wipro ]
S & L of 1.1 KV grade 3 X 1.5 Sq mm FR single core multi stranded copper wire for connection from loop box to fittings through 13 mm dia polythene pipe.
Finishing of the PVC insulated wire(3 X 1.5sqmm) ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
S & F of medium gauge G.I pipe (ISI medium) having the following diameter [32 mm Diameter] for protection of cable with necessary fitting and jointing materials as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI medium G.I pipe)
SUB HEAD XII : SITC OF LIGHT FITTINGS & FANS
S& Delivery of 250 V.24'' sweep A.C. Exaust fan (Heavy Duty , E.P.C./Orient make). ) incl.Fixing the exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection also S & F of louver shutter/coul on wall with necy. bolts & nuts (6 mm dia x 62 mm long) including Timer control switch as per G.S
S&Delivery of 250 V.12'' sweep A.C. Exaust fan (Heavy Duty , E.P.C./Orient make). ) incl.Fixing the exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection also S & F of louver shutter/coul on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per G.S
S & Delivery 230V 50Hz 400 mm sweep heavy duty full metal body /Decorative type wall bracket fan with all accessories on wall with necy. bolts & nuts. INCL Timer control switch .
Supply & delivery of 250 volt. 48" (1200 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Double Ball Bearing & Low Noise. [Make - Crompton HB+ or HS+/Orient Energy star/Usha Striker/Make of Similar specification As per Approved Make List]
Supply & delivery of 250 volt. 56" (1400 mm) sweep A.C. Ceiling fan having safety wire , P2 type capacitor incl. down rod, canopy & fan blades etc. complete with all accessories (without regulator) & having Double Ball Bearing & Low Noise. [Make: Crompton Aura, / Orient Gratia/Make of Similar specification as per Approved Make List]
S&D of 240V Single industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 1xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 1x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen PC Body/ Equivalent product of Crompton/Wipro having similar specification in all respect)
S&D of 240V Twin industrial box (thick ness of box should not be less than 22 SWG) type luminaire with CRCA body (Make :- Philips -TMC 501P 2xT-LED22W P3241/ Equivalent product of Crompton/Wipro having similar specification in all respect). incl S&D 2x 18 watts 4 ft LED tube lamp (Make:- Philips, Cat - Mas LED tube 1200 mm 18W865 T8 I 2100 Lumen )
S& D of 230V 36 watt LED recessed luminaries 2' x 2' recess type corresponding (make-Philips cat no-DN194BED15S-6500PSU WH S1 or equivalent of all respect for Wipro /Crompton) on fails cellig as per direction of EIC.
S& D of 230V 15watt LED recessed luminaries circular type corresponding (make-Philips cat no-DN194BED15S-6500PSU WH S1/Equavalent product of Crompton/Wipro having similar specification in all respect) for false cellig as per direction of EIC.
Supplying & D 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
S& Dof 230V LED Sleek Surface Downlight 700-2000 Lumen (make-Philips cat no-SM251C LED20S-6500 PSU WH or Equivalent product of Crompton/Wipro having similar specification in all respect)/Crompton) (8"x8") on surface ceiling as per direction of EIC.
SUB HEAD XIII : SITC OF LED SIGNAGE
Designing, Fabrication, Supply, Installation, Testing & Commissioning of Outdoor LED Signage as per detail specification and approved make attached ( uploaded in the specification section)
SUB-HEAD XIV : D G INSTALLATION WORK:
S&F MS angle iron structure made of (80x80x6)mm / (50x50x6)mm MS angle to support 350mm dia MS pipe Incl painting as per GS.
Supply and Installation of exhaust pipe line connection with MS black pipe 350mm (14”) dia ISI approved, necessary nuts, bolts, washer, gasket incl. electrical welding where necessary.
Supply and Installation of exhaust pipe line connection with MS black pipe 250mm (10”) dia ISI approved, necessary nuts, bolts, washer, gasket incl. electrical welding where necessary.
S&F 350mm dia MS heavy type long bend
S&F 250mm dia MS heavy type long bend
S&F 350mm dia MS heavy type 'T'
S&F250mmX 250mm X350mm MS heavy type reducing ''T''/ ''Y''
Painting the 350 dia MS black pipe by Aluminum paint of two coat over the RO primer. Approved make.
Painting the 250 dia MS black pipe by Aluminum paint of two coat over the RO primer. Approved make.
Wrapping the Exhaust pipe line (350mm dia) with Al. sheet high quality with necessary wire mesh & 50mm thick glass wool.as per direction of EIC.
Wrapping the Exhaust pipe line (250mm) with Al. sheet high quality with necessary wire mesh & 50mm thick glass wool.as per direction of EIC.
S&F rain protection canopy for 350mm Exhaust pipe.
S&F rain protection canopy for 250mm Exhaust pipe.
wrapping the residential type exhaust silencer.
Hire charges for scaffolding by bamboo required rope of square type arrangement for smooth working & carriage of MS black pipe by vertical run & dismantling at the end of work.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for treatment of soil by using salt and charcoal for earth electrod .
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supply & Laying of 16core 2.5Sqmm Copper Aurmoured control cable, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as 100mm and mending good the damages to original finish incl. removing the rubbish
Supply & Laying of 2core 6 Sqmm Copper Aurmoured cable, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as 100mm and mending good the damages to original finish incl. removing the rubbish
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
a. 16core 2.5Sqmm Copper Aurmoured cable
b. 2core 6Sqmm Copper Aurmoured cable
Finishing the end of following sizes armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) alongwith PVC adhesive tapes, anticorrosive paste & necessary jointing materials
a) 16core 2.5Sqmm Copper Aurmoured cable
b) 2core 6Sqmm Copper Aurmoured cable
Supply and delivery DIESEL for 1010 DG set .
Carrying cost for 2790 ltr Diesel from Pump Station to Site .
Supply and delivery 200 ltr capacity Oil Tank as per direction of EIC .
Supply and delivery electrical fuel transfer pump . ( electrical operation) as per direction of EIC .
Terms and condition
The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Defect Liability period 1 (One) Year
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)
RASH ELECTRICAL WORKS
JADOB ELECTRIC CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .