Tender Value
₹65.0 L
EMD Value
₹1.3 L
Closing Date
7 Aug 2026, 1:00 pm
Repairing and Painting of staff quarters at Sonpur under jurisdiction SSE/Works/SEE.
SEE26-27-81
SEE26-27-81
Open
Works - General
6 Months
Balrampur, Uttar Pradesh
₹0
₹1.3 L
15 Jul 2026
15 Jul 2026
24 Jul 2026
(Schedule -A), Annexure "A-1" attached, except steel reinforcement. under CPWD specification.
All Items of Wrok provided in the CPWD'DSR' - 2021 with upto date corrections as per (Schedule -A),
Annexure "A-1" attached, except steel reinforcement. under CPWD specification.
S No. Item No Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Earth work in excavation by mechanical means
(Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding 1.5
m in width or 10 sqm on plan), including dressing
of sides and ramming of bottoms, lift upto 1.5 m,
including getting out the excavated soil and
disposal of surplus excavated soil as directed,
within a lead of 50 m.
2.27 Supplying and filling in plinth with sand under cum 10 2161.2 21612
2 floors, including watering, ramming,
consolidating and dressing complete.
Surface dressing of the ground including
removing vegetation and in-equalities not
exceeding 15 cm deep and disposal of rubbish,
lead up to 50 m and lift up to 1.5 m.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement concrete
4.1 of specified grade excluding the cost of centering
and shuttering - All work up to plinth level :
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived cum 25 7365.15 184128.75
from natural sources : 4 graded stone aggregate
20 mm nominal size derived from natural
5.0 REINFORCED CEMENT CONCRETE
5.1S CAST IN SITU
Providing and laying in position specified grade
of reinforced cement concrete, excluding the cost
of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
derived from natural sources: 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
Reinforced cement concrete work in walls (any
thickness), including attached pilasters,
buttresses, plinth and string courses, fillets,
5.2 columns, pillars, piers, abutments, posts and
struts etc. above plinth level up to floor five level,
excluding cost of centering, shuttering, finishing
and reinforcement :
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.3 Suspended floors, roofs, landings, balconies and Sqm 25 766.55 19163.75
access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 30 608.35 18250.5
bressumers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 15 804.25 12063.75
5.12S PRE-CAST RCC
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
5.12 Providing, hoisting and fixing above plinth level cum 5 9673.5 48367.5
up to floor five level precast reinforced cement
concrete work in string courses, bands, copings,
bed plates, anchor blocks, plain window sills and
the like, including the cost of required centering,
shuttering but , excluding cost of reinforcement
with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)
derived from natural sources : 3 graded stone
aggregate 20 mm nominal size derived from
natural sources).
6.0 MASONRY WORK
Brick work with common burnt clay F.P.S. (non
6.1 modular) bricks of class designation 7.5 in
foundation and plinth in:
Brick work with common burnt clay F.P.S. (non
modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
level in all shapes and sizes in :
6.12S HALF BRICK MASONRY
Half brick masonry with common burnt clay F.P.S.
6.12 (non modular) bricks of class designation 7.5 in
foundations and plinth in :
Half brick masonry with common burnt clay F.P.S.
(non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V
8.0 CLADDING WORK
8.20S STONE WORK DRY CLADDING
8.31 Providing and fixing Ist quality ceramic glazed Sqm 1130 1063.45 1201698.5
wall tiles conforming to IS: 15622 (thickness to
be specified by the manufacturer), of approved
make, in all colours, shades except burgundy,
bottle green, black of any size as approved by
16 Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per
sqm, including pointing in white cement mixed
with pigment of matching shade complete.
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing wood work in frames of doors,
windows, clerestory windows and other frames,
wrought framed and fixed in position with hold
fast lugs or with dash fasteners of required dia &
length (hold fast lugs or dash fastener shall be
paid for separately).
9.1.3 Kiln seasoned and chemically treated hollock cum 1.5 74199.7 111299.55
Providing and fixing panelled or panelled and
glazed shutters for doors, windows and
clerestory windows, fixing with butt hinges of
required size with necessary screws, excluding
panelling which will be paid for separately, all
complete as per direction of Engineer-in-charge.
(Note:- Butt hinges and necessary screws shall be
paid separately)
Kiln seasoned and chemically treated hollock
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Providing and fixing panelling or panelling and
glazing in panelled or panelled and glazed
shutters for doors, windows and clerestory
9.7 windows (Area of opening for panel inserts
excluding portion inside grooves or rebates to be
measured). Panelling for panelled or panelled
and glazed shutters 25 mm to 40 mm thick :
9.7.2 Kiln seasoned and chemically treated hollock Sqm 25 2039.8 50995
9.7.3 Ply wood 5 ply, 9 mm thick
9.7.3.1 Decorative plywood both side decorative veneer Sqm 15 2366.35 35495.25
(Type - I) conforming to IS 1328 BWR type
9.7.7 Float glass panes
9.7.7.1 4 mm thick glass pane (weight not less than Sqm 10 1897.1 18971
Providing and fixing 25 mm thick shutters for cup
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I) non-
decorative type, core of block board construction
9.21 with frame of 1st class hard wood and well
matched commercial 3 ply veneering with
vertical grains or cross bands and face veneers
on both faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel Sqm 35 2015.75 70551.25
butt hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required pattern
in frames of windows etc. with M.S. flats, square
or round bars etc. including priming coat with
approved steel primer all complete.
9.48.2 Fixed to openings /wooden frames with rawl Kg 350 197.7 69195
plugs screws etc.
Providing and fixing fly proof galvanized M.S.
wire gauge to windows and clerestory windows
9.51 using wire gauge with average width of aperture
1.4 mm in both directions with wire of dia 0.63
mm all complete.
9.55S BRIGHT FINISHED M.S. FITTINGS
Providing and fixing ISI marked, IS : 1341, M.S.
9.56 heavy weight bright finishied butt hinges with
necessary screws etc. complete :
COPER OXIDISED MILD STEEL FITTINGS (COPPER
OXIDISED AS PER IS: 1378)
Providing and fixing ISI marked oxidised M.S.
9.62 sliding door bolts with nuts and screws etc.
complete : (copper oxidized as per IS: 1378)
Providing and fixing ISI marked oxidised M.S.
tower bolt black finish, (Barrel type) with
necessary screws etc. complete : (copper oxized
as per IS: 1378)
Providing and fixing ISI marked oxidised M.S.
handles conforming to IS:4992 with necessary
screws etc. complete : (copper oxized as per IS:
9.105S GYPSUM BOARD PARTITIONS
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
9.119 Providing and fixing factory made P.V.C. door Metre 150 408.25 61237.5
frame of size 50x47 mm with awall thickness of 5
mm, made out of extruded 5mm rigid PVC foam
sheet, mitred at corners and joined with 2 Nos of
150 mm long brackets of 15x15 mm M.S. square
tube, the vertical door frame profiles to be
29 reinforced with 19x19 mm M.S. square tube of 19
gauge, EPDM rubber gasket weather seal to be
provided through out the frame. The door frame
to be fixed to the wall using M.S. screws of
65/100 mm size, complete as per manufacturer's
specification and direction of Engineer- in-
Providing and fixing factory made panel PVC door
shutter consisting of frame made out of M.S.
tubes of 19 gauge thickness and size of 19 mm x
19 mm for styles and 15x15 mm for top &
bottom rails. M.S. frame shall have a coat of steel
primers of approved make and manufacture.
M.S. frame covered with 5 mm thick heat
moulded PVC 'C' channel of size 30 mm
thickness, 70 mm width out of which 50 mm shall
be flat and 20 mm shall be tapered in 45 degree
angle on both side forming styles and 5 mm
thick, 95 mm wide PVC sheet out of which 75mm
shall be flat and 20 mm shall be tapered in 45
degree on the inner side to form top and bottom
rail and 115 mm wide PVC sheet out of which 75
9.120 mm shall be flat and 20 mm shall be tapered on
both sides to form lock rail. Top, bottom and lock
rails shall be provided both side of the panel. 10
mm (5 mm x 2 ) thick, 20 mm wide cross PVC
sheet be provided as gap insert for top rail &
bottom rail, paneling of 5 mm thick both side PVC
sheet to be fitted in the M.S. frame welded/
sealed to the styles & rails with 7 mm (5 mm+2
mm) thick x 15 mm wide PVC sheet beading on
inner side, and joined together with solvent
cement adhesive. An additional 5 mm thick PVC
strip of 20 mm width is to be stuck on the interior
side of the 'C' Channel using PVC solvent
adhesive etc. complete as per direction of
Engineer-in-charge, manufacturer's specification
10.0 STEEL WORK
10.2 Structural steel work riveted, bolted or welded in Kg 1195 111.95 133780.25
built up sections, trusses and framed work,
31 including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer
10.4 Providing and fixing 1 mm thick M.S. sheet Sqm 12 5374.35 64492.2
sliding-shutters, with frame and diagonal braces
of 40x40x6 mm angle iron, 3 mm M.S. gusset
32 plates at the junctions and corners, 25 mm dia
pulley, 40x40x6 mm angle and T- iron guide at
the top and bottom respectively, including
applying a priming coat of approved steel primer
Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc.,
including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer,
including welding and bolted with special shaped
washers etc. complete.
11.0 FLOORING
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
11.2 Dry brick on edge flooring in required pattern Sqm 50 733.3 36665
with bricks of class designation 7.5 on a bed of
34 12 mm mud mortar, including filling joints with
local sand, with common burnt clay non modular
Cement concrete flooring 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate) finished
11.3 with a floating coat of neat cement, including
cement slurry, but excluding the cost of nosing of
steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone Sqm 750 545 408750
11.37S CERAMIC GLAZED TILES
11.37 Providing and laying Ceramic glazed floor tiles of Sqm 200 935.6 187120
size 300x300 mm (thickness to be specified by
the manufacturer) of 1st quality conforming to IS
: 15622 of approved make in colours such as
White, Ivory, Grey, Fume Red Brown, laid on 20
mm thick cement mortar 1:4 (1 Cement : 4
Coarse sand), Jointing with grey cement slurry @
3.3 kg/sqm including pointing the joints with
white cement and matching pigment etc.,
11.41S VITRIFIED FLOOR TILES
Providing and laying Polished Granite stone
flooring in required design and patterns, in linear
as well as curvilinear portions of the building all
complete as per the architectural drawings with
18 mm thick stone slab over 20 mm (average)
thick base of cement mortar 1:4 (1 cement : 4
coarse sand) laid and jointed with cement slurry
and pointing with white cement slurry admixed
with pigment of matching shade including
rubbing , curing and polishing etc. all complete
as specified and as directed by the Engineer-in-
11.56.1 Polished Granite stone slab colour of Black, Sqm 40 3908.8 156352
Cherry/Ruby Red or equivalent
12.0 ROOFING
Providing, fixing and embedding sand cast iron
accessories for rain water pipes in the masonry
12.40 surrounded with 12 mm thick cement mortar of
the same mix, as that of masonry (lead caulking
will be paid for separately):
Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes conforming to IS :
12.41 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised -
PVC moulded fittings/ accessories for
unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including
jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.5 Bend 87.5 degrees
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Providing and fixing false ceiling at all height
including providing and fixing of frame work
made of special sections, power pressed from
M.S. sheets and galvanized with zinc coating of
120 gms/sqm (both side inclusive) as per IS : 277
and consisting of angle cleats of size 25 mm wide
x 1.6 mm thick with flanges of 27 mm and
37mm, at 1200 mm centre to centre, one flange
fixed to the ceiling with dash fastener 12.5 mm
dia x 50mm long with 6mm dia bolts, other
flange of cleat fixed to the angle hangers of
25x10x0.50 mm of required length with nuts &
bolts of required size and other end of angle
hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200
mm centre to centre, to which the ceiling section
0.5 mm thick bottom wedge of 80 mm with
tapered flanges of 26 mm each having lips of
10.5 mm, at 450 mm centre to centre, shall be
fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made
out of 2.64 mm dia x 230 mm long G.I. wire at
every junction, including fixing perimeter
channels 0.5 mm thick 27 mm high having
flanges of 20 mm and 30 mm long, the perimeter
of ceiling fixed to wall/partition with the help of
rawl plugs at 450 mm centre, with 25mm long
dry wall screws @ 230 mm interval, including
fixing of gypsum board to ceiling section and
perimeter channel with the help of dry wall
screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of
tapered and square edges of the board with
recommended jointing compound , jointing tapes
, finishing with jointing compound in 3 layers
covering upto 150 mm on both sides of joint and
two coats of primer suitable for board, all as per
manufacturer's specification and also including
the cost of making openings for light fittings,
grills, diffusers, cutouts made with frame of
perimeter channels suitably fixed, all complete
as per drawings, specification and direction of
the Engineer in Charge but excluding the cost of
painting with :
12.45.3 12.5 mm thick tapered edge gypsum moisture Sqm 100 1300.5 130050
resistant board
12.50 Providing and fixing precoated galvanised iron Sqm 10 671.55 6715.5
profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-charge)
0.50 mm (+ 0.05 %) total coated thickness with
zinc coating 120 grams per sqm as per IS: 277, in
240 mpa steel grade, 5-7 microns epoxy primer
on both side of the sheet and polyester top coat
15-18 microns. Sheet should have protective
guard film of 25 microns minimum to avoid
scratches during transportation and should be
supplied in single length upto 12 metre or as
desired by Engineer-in-charge. The sheet shall be
fixed using self drilling /self tapping screws of
size (5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
13.0 FINISHING
13.4S CEMENT PLASTER (IN COARSE SAND)
13.4 12 mm cement plaster of mix :
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
CEMENT PLASTER WITH A FLOATING COAT OF
15 mm cement plaster on rough side of single or
13.8 half brick wall finished with a floating coat of
neat cement of mix :
13.16S 6MM CEMENT PLASTER
Distempering with oil bound washable distemper
13.41 of approved brand and manufacture to give an
13.41.1 New work (two or more coats) over and including Sqm 550 162.55 89402.5
water thinnable priming coat with cement primer
13.44S EXTERIOR FINISHING
Finishing walls with water proofing cement paint
of required shade :
13.44.1 New work (Two or more coats applied @ 3.84 Sqm 450 97.6 43920
Finishing with Deluxe Multi surface paint system
13.48 for interiors and exteriors using Primer as per
manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 ltr/10 Sqm 50 158.95 7947.5
48 sqm over and including one coat of Special
primer applied @ 0.75 ltr /10 sqm
Painting with synthetic enamel paint of approved
brand and manufacture to give an even shade :
Lettering with black Japan paint of approved letter
brand and manufacture per cm
13.80 Providing and applying white cement based putty Sqm 550 123.85 68117.5
of average thickness 1 mm, of approved brand
51 and manufacturer, over the plastered wall
surface to prepare the surface even and smooth
Applying priming coats with primer of approved
13.85 brand and manufacture, having low VOC (Volatile
Organic Compound ) content.
13.88 Removing white or colour wash by scrapping and Sqm 2000 16.35 32700
sand papering and preparing the surface smooth
including necessary repairs to scratches etc.
Distempering with 1st quality acrylic distember
(Ready mix) having VOC content less than 50
grams/ litre of approved brand and manufacture
to give an even shade :
Painting with synthetic enamel paint of approved
13.99 brand and manufacture of required colour to give
an even shade :
Finishing walls with water proofing cement paint
of required shade :
14.0 REPAIRS TO BUILDING
Repairs to plaster of thickness 12 mm to 20 mm
in patches of area 2.5 sq.meters and under,
including cutting the patch in proper shape,
14.1 raking out joints and preparing and plastering the
surface of the walls complete, including disposal
of rubbish to the dumping ground, all complete
as per direction of Engineer-in-Charge.
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
14.1.2 With cement mortar 1:4 (1cement: 4 coarse Sqm 150 478 71700
Fixing chowkhats in existing opening including
embedding chowkhats in floors or walls cutting
masonry for holdfasts, embedding hold fasts in
cement concrete blocks of size 15 x 10 x 10 cm
with cement concrete 1:3:6 (1 cement : 3 coarse
sand : 6 graded stone aggregate 20 mm nominal
size), painting two coats of approved wood
preservative to sides of chowkhats and making
good the damages to walls and floors as required
complete, including disposal of rubbish to the
dumping ground, all complete as per direction of
Engineer-in-Charge.
Renewing glass panes, with putty and nails
14.5 wherever necessary including racking out the old
14.5.1 Float glass panes of nominal thickness 4 mm Sqm 15 941.95 14129.25
(weight not less than 10kg/sqm)
Renewing wooden beams in roofs including
making good the holes in walls and painting with
oil type wood preservative of approved brand
and manufacture complete, including removal of
rubbish to the dumping ground, all complete as
per direction of Engineer-in-Charge.
14.17 Raking out joints in lime or cement mortar and Sqm 50 59.75 2987.5
preparing the surface for re-pointing or
60 replastering, including disposal of rubbish to the
dumping ground, all complete as per direction of
Engineer-in-Charge.
15.0 DISMANTLING AND DEMOLISHING
Demolishing cement concrete manually/ by
mechanical means including disposal of material
within 50 metres lead as per direction of
Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c cum 12 2007.1 24085.2
equivalent design mix)
15.3 Demolishing R.C.C. work manually/ by cum 1.2 2928.1 3513.72
mechanical means including stacking of steel
62 bars and disposal of unserviceable material
within 50 metres lead as per direction of
Engineer - in- charge.
Demolishing brick work manually/ by mechanical
means including stacking of serviceable material
15.7 and disposal of unserviceable material within 50
metres lead as per direction of Engineer-in-
Taking out doors, windows and clerestory window
15.13 shutters (steel or wood) including stacking within
50 metres lead :
15.19 Dismantling steel work manually/ by mechanical Kg 150 3.2 480
means in built up sections without dismembering
and stacking within 50 metres lead as per
direction of Engineer-in-charge.
Dismantling tile work in floors and roofs laid in
15.23 cement mortar including stacking material within
50 metres lead.
Dismantling roofing including ridges, hips, valleys
15.28 and gutters etc., and stacking the material within
50 metres lead of:
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Dismantling G.I. pipes (external work) including
excavation and refilling trenches after taking out
15.44 the pipes, manually/ by mechanical means
including stacking of pipes within 50 metres lead
as per direction of Engineer-in-charge :
16.0 ROAD WORK
16.42S CONCRETE PAVEMENTS
16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand cum 25 7399.2 184980
: 4 graded stone aggregate 40 mm nominal size)
69 in pavements, laid to required slope and camber
in panels as required including consolidation
finishing and tamping complete.
17.0 SANITARY INSTALLATIONS
Providing and fixing water closet squatting pan
(Indian type W.C. pan ) with 100 mm sand cast
Iron P or S trap, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with
manually controlled device (handle lever)
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of Each 20 5781.35 115627
size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china
pedestal type water closet (European type W.C.
pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with
manually controlled device (handle lever),
conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making
good the walls and floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat Each 10 5540.55 55405.5
Providing and fixing wash basin with C.I.
brackets, 15 mm C.P. brass pillar taps, 32 mm
17.7 C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and
making good the walls wherever require:
17.7.4 White Vitreous China Flat back wash basin size Each 20 1679.6 33592
72 550x 400 mm with single 15 mm C.P. brass pillar
Providing and fixing Stainless Steel A ISI 304
(18/8) kitchen sink as per IS:13983 with C.I.
brackets and stainless steel plug 40 mm,
including painting of fittings and brackets,
cutting and making good the walls wherever
17.10.2 Kitchen sink without drain board
Providing and fixing white vitreous china water
closet squatting pan (Indian type) :
Providing and fixing P.V.C. low level flushing
cistern with manually controlled device (handle
lever) conforming to IS : 7231, with all fittings
and fixtures complete.
Providing and fixing P.V.C. waste pipe for sink or
17.28 wash basin including P.V.C. waste fittings
17.28.2 Flexible pipe
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
17.31 Providing and fixing 600x450 mm beveled edge Each 25 1411.15 35278.75
mirror of superior glass (of approved quality)
78 complete with 6 mm thick hard board ground
fixed to wooden cleats with C.P. brass screws and
washers complete.
18.0 WATER SUPPLY
18.7S C.P.V.C. PIPES
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing
18.7 the pipe with clamps at 1.00 m spacing. This
includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints
complete as per direction of Engineer in Charge.-
Internal work - Exposed on wall
Providing and fixing Chlorinated Polyvinyl
Chloride (CPVC) pipes, having thermal stability
for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe
with clamps at 1.00 m spacing. This includes
18.8 jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases
and making good the same including testing of
joints complete as per direction of Engineer in
Charge, Concealed work, including cutting
chases and making good the wall etc.
Providing and fixing G.I. pipes complete with G.I.
18.10 fittings and clamps, i/c cutting and making good
the walls etc.-Internal work - Exposed on wall
18.15S BRASS FITTINGS
Providing and fixing ball valve (brass) of
18.18 approved quality, High or low pressure, with
plastic floats complete :
Providing and fixing uplasticised PVC connection
pipe with brass unions :
18.21.2 45 cm length
Providing and fixing C.P. brass shower rose with
15 or 20 mm inlet :
18.31S C.I. SLUICE VALVES/ FIRE HYDRANTS & FIXTURES
18.48 Providing and placing on terrace (at all floor Litre 10000 9.7 97000
levels) polyethylene water storage tank, IS :
12701 marked, with cover and suitable locking
arrangement and making necessary holes for
inlet, outlet and overflow pipes but without
fittings and the base support for tank.
18.49S C.P. BRASS FITTINGS
Providing and fixing C.P. brass bib cock of
approved quality conforming to IS:8931 :
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
Providing and fixing C.P. brass stop cock
18.52 (concealed) of standard design and of approved
make conforming to IS:8931.
Providing and fixing C.P. brass angle valve for
18.53 basin mixer and geyser points of approved
quality conforming to IS:8931
18.54S PTMT FITTINGS
Providing and fixing PTMT bib cock of approved
quality and colour.
18.54.3 15 mm nominal bore, 165 mm long, weighing not Each 100 156.65 15665
less than 110 gms
Providing and fixing PTMT stop cock of approved
quality and colour.
18.55.3 Concealed stop cock, 15 mm nominal bore, 108 Each 10 183.4 1834
mm long, weighing not less than 108 gms
21.0 ALUMINIUM WORK
Providing and fixing aluminium work for doors,
windows, ventilators and partitions with extruded
built up standard tubular sections/ appropriate Z
sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with
dash fasteners of required dia and size, including
necessary filling up the gaps at junctions, i.e. at
top, bottom and sides with required EPDM
21.1 rubber/ neoprene gasket etc. Aluminium sections
shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing /
paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the
directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of Kg 57.6 466.3 26858.88
powder coating 50 micron)
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots and
making provision for fixing of fittings wherever
required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall be paid
for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of Kg 30 564.8 16944
powder coating 50 micron)
Schedule Schedule A 3-Items of steel reinforcement under DSR-2021
Item- 01 Items of steel reinforcement under DSR-2021
S No. Item No Description of Item Unit Qty Rate Amount
5.0 REINFORCED CEMENT CONCRETE
5.22S STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Fe- Kg 800 89.65 71720
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above plinth
SONPUR DIVISION-ENGINEERING/EAST CENTRAL RLY
5.22A.6 Thermo-Mechanically Treated bars of grade Fe- Kg 1200 89.65 107580
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument-81.pdf
ATTACHMENT
B.Gsubmissionguideline_.pdf
ATTACHMENT
PolicyRBCE6dt.17.05.2004.pdf RB POLICY
ATTACHMENT
TelecomCircular9-2023.pdf
ATTACHMENT
PolicyRBCE6dt.17.05.2004.pdf
ATTACHMENT
Download all tender documents and submit your bid