| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.3 LAccepted-AOC 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹32.7 L+₹11.4 L (53.4%)Rejected-Finance | L-2 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
14 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
CERTAIN EandM MINOR WORKS AT AF STATION, BAREILLY.
2021_MES_472137_2
8602 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
BAREILLY
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer (AF), Bareilly
₹41,000
Yes
23 Oct 2021
30 Sept 2021
16 Oct 2021
30 Sept 2021
14 Oct 2021
30 Sept 2021
60 days
Amount
M&L for Point wiring complete as specified with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including rigid non-metallic PVC conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one 3 pin 16 Amps socket out let on independent board. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F switch piano, flush type, SP, one way, 15/ 16 Amps, 250 V, ISI marked.
M&L for sub main wiring concealed complete with two runs of single core 4 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. including provision of earth continuity wire with same cable as for wiring but in green colour all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F Heavy duty (Fully Metal construction) wall mount Air Circulator fan 450mm sweep, 1440 rpm, 4 speed control with regulator, single phase, 230 volts AC, 50 Hz consisting of powerful circulator motor with spiral guard design ensures high air thrust, high torque gear box with safety clutch, broad blade profile for low noise, resettable thermal overloaded protector, oscillating mechanism including making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete all as specified and directed. [Make: Almonard/ Khaitan/ Usha].
S&F MCB SPN, 240 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
S&F MCB SP, 5 to 32 Amps, 230 V, C curve, 10 KA all as specified and as directed.
M&L for Point wiring complete as specified with 1100 volt grade 1.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including rigid non-metallic PVC conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one fan/ light point controlled by on 5 Amp switch. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F switch piano, flush type, SP, one way, 5/ 6 Amps, 250 V, ISI marked.
S&F socket outlet 2 in 1, 5 pin 5/6 Amps, flush type, 250 V, ISI marked.
S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 6 Amps and 16 Amp, flush type, 250 V, ISI marked.
S&F ceiling fan 1200mm sweep complete with down rod, down rods, and other accessories working on 230 V AC minimum air delivery of 210 cfm with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
S&F step type electronic fan regulator, 120 Watt complete all as specified.
S&F ceiling rose PVC/ Poly carbonate isolated body, three terminal complete all as specified.
S&F suspended/ surface type High bay luminaire 80 Watt, environmental friendly, energy saving long life corrosion resistant vertical surface mounting pressure die-cast aluminium housing and control gear with high power LED with all mounting accessories for fixing to truss of hangar/ MT garage etc complete prewired with flexible 3 core 1.50sq.mm size stranded copper conductor cable from light fitting to ceiling rose complete all as specified and as directed. [Model: SAUCERGENXPROHBP80WLED 757 P90 DBOLTG of make: Havells or BY515P LED100S 5700 NB PSU GR of make Philips or LH17-132-060-50-XX of make: Wipro]
M&L for sub main wiring concealed complete with 4 runs of single core 10 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 32mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. including provision of 2 runs of earth continuity wire with same cable as for wiring but in green colour all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F sheet steel powder coated distribution board TPN 4 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F MCB TPN, 415 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
M&L for flame proof wiring with single core PVC insulated and unsheathed 1100 Volts grade (ZHFR) Zero Halogen Flame Retardant Smoke Free Non-Toxic Non-Corrosive Electric Cable with multi stranded copper conductor of size 1.5 Sq.mm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia surface type including all flame proof conduit fittings and accessories such as tees, junction boxes, bends, duly tested by CMRI Dhanbad suitable for one light/ fan point controlled by one flame proof rotary switch SP one way, duly earthed with same cable as for wiring above but green in colour as continuous earthing wire connected to earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F LED tube light fitting 1x 16 Watt Flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with driver, holders, connector etc. complete with all accessories prewired and including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified and as directed. [Make :- Sudhir/ Crompton/ Shyam/ Baliga]
S&F Flame Proof Exhaust Fan 305mm (12") sweep, 1440 RPM speed, 23 volts, single phase, 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor mounted on 02 ball bearings alongwith louvers with and including making suitable size hole on wall and making good the same as per existing finishes and necessary fixing arrangement on wall and connecting electrically with 3 Core 1.00 Sq.mm size PVC insulated FRLS flexible copper conductor cable overall sheathed drawn through flame proof flexible conduit all as required at site with connected accessories complete all as specified and as directed. [Make :- Sudhir Cat Part No EF/140 or equivalent in Crompton/ Shyam/ Baliga]
S&F Flame proof weather proof direct entry type rotary switch single pole ON and OFF rotary motion switch in cast aluminium alloy LM-6 enclosure epoxy powder coated single pole 230 Volt 10 Amp AC ON/OFF switch operated externally by knob having two nos of M-20 cable entries, earthing terminal suitable for mounting on wall/ steel structure etc duly tested and certified by CMRI Dhanbad complete all as specified and directed. [Make:- Sudhir/ Baliga/ Shyam]
Supply, laying, testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 2 core x 6 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
Returning, filling in including spreading leveling watering and well ramming in layers not exc. 25cm in any type of soil.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point.
Supply and spread river sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
M&L for well burnt Sub class 'B', modular bricks laid dry, flat, over the cable abutting each other, complete all as specified and directed.
M&L for digging of bore well of 5" dia up to 60 metre depth below ground level in any type of soil strata for placing pipe suitable for submersible pump motor of 2 HP capacity complete all as specified and directed.
Supply and lowering of 110 mm nominal bore PVC casing pipe with minimum 3mm wall thickness in bore well complete all as specified and directed.
Supply and lowering of 110 mm nominal bore PVC strainer pipe with minimum 3mm wall thickness in bore well complete all as specified and directed.
M&L for set of strainer cloths, cotton cloth, solvent, nylon rope, PVC caps and clamps etc. complete all as specified and directed.
Supply, installation, commissioning and testing of submersible pump set single phase, of capacity suitable for a discharge of 12000 LPH at a head of 30 metres complete all as specified and directed. [Make: Kirloskar/ KSB/ CG]
S&F 2.50 sq.mm size three core flat type copper conductor submersible cable complete with water proof connections all as specified and directed.
S&F starter panel suitable for operating of submersible pump set of 2 HP capacity, single phase including all connecting accessories as required complete all as specified and directed. [Make: L&T/ Standard/ Havells/ BCH]
S&F 5mm dia multi-stranded steel rope suitable for pump motor protection and the like complete all as specified and directed.
S&F of 25 mm bore steel water tubing medium grade galvanized with and including all GI fittings as required at site, laid in trenches, in surface, under floor or fixed to wall complete all as specified and directed.
S&F of 50 mm bore steel water tubing medium grade galvanized with and including all GI fittings as required at site, laid in trenches, in surface, under floor or fixed to wall complete all as specified and directed.
S&F 25mm bore gun metal globe or gate valve with iron wheel heads Class-II, screwed both ends for iron pipe all as specified.
S&F 50mm bore gun metal globe or gate valve with iron wheel heads Class-II, screwed both ends for iron pipe all as specified.
S&F 32mm bore heavy duty PVC column pipe 12.5 kg/cm² pressure rating with threaded ends complete including lowering to bore well all as specified and directed.
Supply, laying, testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 2 core x 10 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
S&F three core PVC insulated flexible cable cord 1.50 Sq.mm multi-stranded copper conductor cable 1100 volts grade drawn into and including rigid PVC conduit not less than 15 mm dia with all necessary fixing arrangements such as PVC clamp, nut-bolts etc. as required at site as per direction of Engineer-in-charge for protection from wear/tear including thimbles as required for making connection from pole box to flood light fitting complete all as specified and as directed.
Supply and fix die cast aluminium LED Flood light not less than 60W IP 66 with high power LEDs, integral flood light with driver inside a PDC housing including all fittings, clamps, angle frame etc for fixing on wall/ pole etc complete all as specified and as directed. [Make: Cat Part No. JETA PROFL70WLED757LT G of make Havells or LF19-711-060-57-XX of make: Wipro or BVP192 LED82 CW HO NB FG GR PSU of make: Philips].
M&L for Chemical Earthing with copper earth plate electrode 900 x 600 x 5 mm thick buried directly in ground, earth pit not less than 4.70 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.60 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnesium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 32 x 6 mm (up to 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65mm bore light grade GI pipe from electrode and up to the earth test point, 15 mm bore light grade GI watering pipe, GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt, charcoal dust and Magnesium sulphate filling in each alternate layers up to 1.80 m height including excavation, removal surplus soil to a distance not exc. 50 m, PCC pit in PCC (1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. NOTE:- Additional Chemical compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
Supply and fixing of 32 X6 mm size copper strip as in earth continuity conductor or main earthing lead buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed.
Supply, install, testing & commissioning of isolation transformer of capacity 10 KVA, 3 Phase, 415 Volts, 50 Hz, ONAN type cooled oil immersed copper wound indoor type complete with first fill of filtered & dehydrated transformer oil conforming to IS-335, electrostatic shield between primary 415V in Delta connected & secondary 415 Star connected complete with other standard fittings/ accessories with Vector group Dyn-11, cable box for incoming & outgoing with cable glands complete all as specified and as directed. [Make: Volina/ ITE Gurgaon/ Servomax]
Supply, laying, testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade, ISI marked as per IS-7098-I, of size 4 core x 25 sq.mm. (laid in trenches, ducts, pole, wall etc.) etc. all as specified.
M&L for earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of copper all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 100 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Supply and fixing of 20 X3 mm size copper strip as in earth continuity conductor or main earthing lead buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs complete all as specified and directed.
Supply, installation, testing and commissioning factory made LT feeder pillar box, outdoor type, platform mounted of size 1000x900x450mm suitable for 415 Volts 3 phase 4 wire system, 50 Hz supply with aluminium bus bar of rating 200 Amps for phases & neutral installed on porcelain/ epoxy insulators; control wiring with PVC insulated multi-stranded copper conductor cable 1100 V grade; the panel shall be dust proof, vermin proof (IP-54) duly powder coated, made out of 3.15mm thick CRCA sheet mounted on ISA 50x50x6mm frame, front & rear openable with double shutters and locking arrangement including grouting the panel with PCC type B1 complete all as specified including housing the following accessories: Incoming: (i) MCCB 63 Amps, 4 pole, 16 KA - 01 No (ii) Voltmeter 0-500 Volts, square flush pattern, digital type - 01 No (iii) Ammeter 0-400 Amps, square flush pattern, digital type - 01 No (iv) LED type indicating lamps RYB- 01 set (v) Alarm system to indicate the commercial power failure Outgoing: (i) MCCB 40 Amps, 4 pole, 16 KA, 415 Volts - 02 Nos
S&F of 40 mm bore steel tubing medium grade galvanized with and including all GI fittings as required at site, laid in trenches, in surface, under floor or fixed to wall complete all as specified and directed.
S&F single pointed air termination copper rod 12mm dia, 300mm long with all connected accessories and PCC block in type B1 of suitable size complete all as specified and as directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screws for holding the bronze plate including fastening/ bolting the roof down conductor and earth electrode over the bronze plate with copper bolts & nuts of suitable size, providing 10mm thick fibre sheet of size 15x15cm below the test point to avoid direct contact with wall including enclosing the test point with 1.6mm thick MS sheet front openable box duly painted complete all as directed by Engineer -in-Charge.
M/s Agarwal Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .