| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.8 L+₹1.1 L (23.6%)Rejected-Finance | L2 | Rejected-Finance 580620.00 | |
| 3 | L3₹5.9 L+₹1.2 L (25.2%)Rejected-Finance | L3 | Rejected-Finance 588160.00 |
Tender Value
Refer Docs
EMD Value
₹10,761
Closing Date
21 Sept 2022, 3:00 pmClosed
Executive Engineer PWD Bidhannagar Electrical Divi
Executive Engineer PWD Bidhannagar Electrical Division
Supply and installation of 10 nos new Split AC machines in place of old damaged AC at Annexe building at Netaji Subhas Administrative Training Institute Salt Lake Kolkata
2022_WBPWD_398745_1
WBPWD/EE/BED/e-NIQ-30/2022_23
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
NSATI
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,761
Yes
Room No 108, Purta Bhavan, Salt Lake, Kol-91
25 Nov 2022
26 Aug 2022
23 Sept 2022
31 Aug 2022
21 Sept 2022
6 Sept 2022
2 Sept 2022
Amount
Dismantling the existing split type AC machines(indoor & outdoor, copper line, drain pipe, insulation, iron bracket, electrical wire etc.) as per direction of EIC
Supply, installation, testing and commissioning of Split type AC machine having Cooling capacity range(5.2 KW-5.3 KW) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating-3(ERR range 3.5 to 3.99), air flow range CFM(680-720), both condenser and cooling coils made of copper tube connecting cord with plug top including MS bracket confirming to IS 1391(Part-I & Part-II) with all amendments (Make-Mitsubishi Electric/O General/Daikin/Carrier/Blue star)(NS)
Supply, installation, testing and commissioning of Split type AC machine having Cooling capacity range(6.6 KW-7.0 KW) with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating-3(ERR range 3.5 to 3.99), air flow range CFM(780-850), both condenser and cooling coils made of copper tube connecting cord with plug top including MS bracket confirming to IS 1391(Part-I & Part-II) with all amendments (Make-Mitsubishi Electric/Daikin/O General/Carrier/Blue star)(NS)
SITC including vaccumiazation and nitrogen of testing of following nominal size of soft/hard drawn copper refrigerant piping for RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XLPE class O tubular insulation/with class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required(NS) 5/8"(15.88 mm) dia(soft drawn) cu. Pipes(As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation
1/4"(6.4 mm) dia(soft drawn) cu. Pipes(As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation
Supply & laying PVC drain pipe 25 mm dia with 6 mm thick nitrile rubber insulation(Supreme/Oriplast)(NS)
(Note :- Rate should be quoted inclusive of all taxes and duties including G.S.T.)
GITANJALI ELECTRONICS AND ELECTRICALS
INDIAN SERVICE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .