ANNUAL OPERATION AND MAINTENANCE OF HVAC SYSTEM AND INTEGRATED BMS
2020_DBTEC_586292_1
CIAB/7(73)/2018-Works
Open Tender
Electrical Works
Works
365 days
CIAB, Sector-81 (Knowledge City), PO Manauli
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
Yes
CIAB
₹43,425
Yes
28 Oct 2020
24 Sept 2020
16 Oct 2020
25 Sept 2020
15 Oct 2020
25 Sept 2020
Annual Operation & Maintenance cost of HVAC system of CIAB as per the scope of work defined in Schedule-A of Volume-1 of tender document
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 500mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 450mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 300mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 250mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 150mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 125mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 80mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 65mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 40mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 32mm dia
Leakage finding, Leakage repairing and leakage testing of Chilled water/Hot water/Condenser water line along with required insulation on water line as in original state complete as per the site requirement for the following sizes of MS pipes 20mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) Pipes, cables etc, not exceeding 80 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All kinds of soil) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre)
Supertech Engineers
greenoz ventilation system
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .