Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.1 LQualified Make: Skylark Thermal Energy Systems
Model: Skylark Solar 28 172 SHANIWAR PETH TRIMBAKESHWAR SOCIETY OFF SHANIWAR WADA PUNE 411030 PUNE CITY MAHARASHTRA 411030 INDIA | PUNE | MAHARASHTRA | 411030 | Make: Skylark Thermal Energy Systems
Model: Skylark Solar 28 | L1 | Qualified | |
| 2 | Disqualified Make: RASHMI
Model: RASHMI RI-500 WO HE HONGASANDRA BANGALORE CITY KARNATAKA 560068 INDIA | BENGALURU URBAN | KARNATAKA | 560068 | Make: RASHMI
Model: RASHMI RI-500 WO HE | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
21 May 2018, 3:00 pmClosed
solar water heating system Average Turn Over of Last 3 Years 25 Lakh (s) Experience with Gov. Required 2 Year (s) Solar Water Heating System ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment N/A BIS Approved Yes Yes
No If Yes
Mention CM/L No. otherwise write NA 6130815 N/A Model Number of Solar Water Heater System 500LPD FPC N/A Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with out Heat Exchanger Solar water Heating System with Heat Exchanger
Solar water Heating System with out Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C N/A Rated Capacity in Litres per Day (LPD) 500 500
1000 Warranty (Years) 5 Years 1 Year
2 Years
3 1/6 Years
4 Years
5 Years
6 Years
7 Years
8 Years CONSTRUCTIONAL Aperture area of collector
Sq. Meteres (Sq Meter) 2.0 1.8
2.0
3.6
4.0
5.4
6.0
9.0
10.0
18.0
20.0 Electrical Heater ( Back up ) Capacity (kw) 6 2
3
4
6
9 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) NA 5.0
NA Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes N/A Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum
Toughened Glass and Anticorrosive Solar Glass with minimum thickness 3.2 mm Solar Transmittance for cover plate at normal Incidence (%) 92 N/A Material for Collector Box Aluminium Aluminium
CRCA Numbers of collectors 4 N/A Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based N/A Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based N/A Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based N/A Thickness of Sheet for entire body >/= 1.0 mm for aluminium based N/A CRCA Material Thickness 0 for Aluminium material N/A Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa N/A 2/6 Number of absorber sheets per collector 9 N/A Numbers of Header Tubes 1 N/A Numbers of Riser Tubes 1 N/A Diameter of Header Tube (mm) >/= 24.5 mm N/A Diameter of riser tube (in mm) >/= 11.5 mm N/A Thickness of Header Tube (mm) >/=0.71 N/A Thickness of Riser Tube (mm) >/= 0.56 mm N/A Material of Riser Header for Absorber Copper Only N/A Distanace Between Risers from center to center (mm) >/= 120 (mm) N/A Material of sheet for absorber Aluminium Copper
Aluminium Collector Box Insulation Back and sides N/A Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km N/A Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km N/A Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes N/A Material for Hot water storage Tank SS304 SS304
SS 316
Cold Rolled Steel (other material as per MNRE Notification year2011)
Mild Steel
any other Material with anticorrosive coating for hard water with chlroine components Name the Material if choose others NA N/A Non Pressure Type Hot water Storage Tank Yes N/A Position of Hot water tank Horizontal N/A 3/6 Thickness of sheet of Hot water tank (mm) 1.2 N/A Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 N/A Hot water Welding TIG N/A Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint N/A Thickness of Coating (micron) 40 N/A Tank stand Material Mild Steel N/A Size of Tank Stand (L x W x H ) Must be Greater Than 38 x 38 x 4 (mm3) Yes N/A Type of Heat Exchanger cage Type N/A Material for Heat Exchanger Stainless steel Copper
Stainless steel Thickness of tube of heat Exchanger
Minimum 22 SWG Yes N/A Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity N/A Numbers of Electrical Heaters ( Back Up Type ) provided 2 2
5 Collector Stand Material Mild steel N/A Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes N/A System Interconnecting Pipes material G.I Pipes as per IS: 1239 N/A if other mention the Material for interconnecting pipes NA N/A Size of interconnecting Pipes (mm) 25.4 N/A Tank test Pressure (bar) 4 N/A 4/6 System Working Pressure (Bar) 2 N/A Inlet and Outlet Valve Yes N/A Temp Gauge( for Hot Water ) Yes N/A Gun Metal Strainer ( for Cold Water ) Yes N/A Water Meter Yes N/A Gasket for Flanges 3 mm thick gasket of neoprene N/A Electrical Back up Control panel Yes N/A Make of Control Panel Others N/A if others
mention the make of Control Panel ANU N/A Weight of solar water heater system (kg) 300 N/A CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools
Part 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes N/A Test Report No. MKU/RTC/18/002 N/A Test Report Date 13/03/2018 N/A Name of the Lab REGIONAL TEST CENTRE N/A Address of the Lab School of energy environment and natural resource Madurai Kamaraj University Madurai-625021 N/A Availability of Schematic Drawing Yes N/A Instruction Manual for installation
Repair and maintanance Yes N/A test teat1 true N/A * Bold specifications are the golden parameters. 5/6 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sivaraj Selvaraj 620015
Indian Institute of Management Tiruchirappalli. Trichy-Puddukottai highway
Chinna sooriyur
Tiruchirappalli – 620 024. 4 15 EMD Required No ePBG Required No
57842
GEM/2018/B/8248
solar water heating system
15 days
Tamil Nadu; Tiruchirappalli
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| solar water heating system Average Turn Over of Last 3 Years 25 Lakh (s) Experience with Gov. Required 2 Year (s) Solar Water Heating System ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment N/A BIS Approved Yes Yes | - | - | - |
| No If Yes | - | - | - |
| Mention CM/L No. otherwise write NA 6130815 N/A Model Number of Solar Water Heater System 500LPD FPC N/A Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with out Heat Exchanger Solar water Heating System with Heat Exchanger | - | - | - |
| Solar water Heating System with out Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C N/A Rated Capacity in Litres per Day (LPD) 500 500 | - | - | - |
| 1000 Warranty (Years) 5 Years 1 Year | - | - | - |
| 2 Years | - | - | - |
| 3 1/6 Years | - | - | - |
| 4 Years | - | - | - |
| 5 Years | - | - | - |
| 6 Years | - | - | - |
| 7 Years | - | - | - |
| 8 Years CONSTRUCTIONAL Aperture area of collector | - | - | - |
| Sq. Meteres (Sq Meter) 2.0 1.8 | - | - | - |
| 2.0 | - | - | - |
| 3.6 | - | - | - |
| 4.0 | - | - | - |
| 5.4 | - | - | - |
| 6.0 | - | - | - |
| 9.0 | - | - | - |
| 10.0 | - | - | - |
| 18.0 | - | - | - |
| 20.0 Electrical Heater ( Back up ) Capacity (kw) 6 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) NA 5.0 | - | - | - |
| NA Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes N/A Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum | - | - | - |
| Toughened Glass and Anticorrosive Solar Glass with minimum thickness 3.2 mm Solar Transmittance for cover plate at normal Incidence (%) 92 N/A Material for Collector Box Aluminium Aluminium | - | - | - |
| CRCA Numbers of collectors 4 N/A Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based N/A Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based N/A Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based N/A Thickness of Sheet for entire body >/= 1.0 mm for aluminium based N/A CRCA Material Thickness 0 for Aluminium material N/A Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa N/A 2/6 Number of absorber sheets per collector 9 N/A Numbers of Header Tubes 1 N/A Numbers of Riser Tubes 1 N/A Diameter of Header Tube (mm) >/= 24.5 mm N/A Diameter of riser tube (in mm) >/= 11.5 mm N/A Thickness of Header Tube (mm) >/=0.71 N/A Thickness of Riser Tube (mm) >/= 0.56 mm N/A Material of Riser Header for Absorber Copper Only N/A Distanace Between Risers from center to center (mm) >/= 120 (mm) N/A Material of sheet for absorber Aluminium Copper | - | - | - |
| Aluminium Collector Box Insulation Back and sides N/A Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km N/A Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km N/A Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes N/A Material for Hot water storage Tank SS304 SS304 | - | - | - |
| SS 316 | - | - | - |
| Cold Rolled Steel (other material as per MNRE Notification year2011) | - | - | - |
| Mild Steel | - | - | - |
| any other Material with anticorrosive coating for hard water with chlroine components Name the Material if choose others NA N/A Non Pressure Type Hot water Storage Tank Yes N/A Position of Hot water tank Horizontal N/A 3/6 Thickness of sheet of Hot water tank (mm) 1.2 N/A Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 N/A Hot water Welding TIG N/A Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint N/A Thickness of Coating (micron) 40 N/A Tank stand Material Mild Steel N/A Size of Tank Stand (L x W x H ) Must be Greater Than 38 x 38 x 4 (mm3) Yes N/A Type of Heat Exchanger cage Type N/A Material for Heat Exchanger Stainless steel Copper | - | - | - |
| Stainless steel Thickness of tube of heat Exchanger | - | - | - |
| Minimum 22 SWG Yes N/A Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity N/A Numbers of Electrical Heaters ( Back Up Type ) provided 2 2 | - | - | - |
| 5 Collector Stand Material Mild steel N/A Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes N/A System Interconnecting Pipes material G.I Pipes as per IS: 1239 N/A if other mention the Material for interconnecting pipes NA N/A Size of interconnecting Pipes (mm) 25.4 N/A Tank test Pressure (bar) 4 N/A 4/6 System Working Pressure (Bar) 2 N/A Inlet and Outlet Valve Yes N/A Temp Gauge( for Hot Water ) Yes N/A Gun Metal Strainer ( for Cold Water ) Yes N/A Water Meter Yes N/A Gasket for Flanges 3 mm thick gasket of neoprene N/A Electrical Back up Control panel Yes N/A Make of Control Panel Others N/A if others | - | - | - |
| mention the make of Control Panel ANU N/A Weight of solar water heater system (kg) 300 N/A CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools | - | - | - |
| Part 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes N/A Test Report No. MKU/RTC/18/002 N/A Test Report Date 13/03/2018 N/A Name of the Lab REGIONAL TEST CENTRE N/A Address of the Lab School of energy environment and natural resource Madurai Kamaraj University Madurai-625021 N/A Availability of Schematic Drawing Yes N/A Instruction Manual for installation | - | - | - |
| Repair and maintanance Yes N/A test teat1 true N/A * Bold specifications are the golden parameters. 5/6 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sivaraj Selvaraj 620015 | - | - | - |
| Indian Institute of Management Tiruchirappalli. Trichy-Puddukottai highway | - | - | - |
| Chinna sooriyur | - | - | - |
| Tiruchirappalli – 620 024. 4 15 EMD Required No ePBG Required No | - | - | - |
Exempted
22 May 2018
4 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_57842.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .