Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-Finance | L1 | Accepted-Finance qualified | |
| 2 | Rejected-Technical | - | Rejected-Technical Shortfall in documents submitted |
Tender Value
Refer Docs
EMD Value
₹16,500
Closing Date
16 Jun 2025, 5:15 pmClosed
Managing Director
KTDC Corporate Office Mascot Square Thiruvananthapuram
Supply installation testing and commissioning of Cassette AC/Split AC units in various sections at KTDC Corporate Offce Thiruvananthapuram
2025_KTDC_766132_1
AE(E)I/KTDC/EW/393/HO-AC/2025
Open Tender
Electrical Works
Item Rate
30 days
KTDC Corporate Office Thiruvananthapuram
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,652
Yes
₹16,500
5 Jul 2025
5 Jun 2025
18 Jun 2025
5 Jun 2025
16 Jun 2025
5 Jun 2025
Amount
PART A
SITC of inverter type Split AC units
Supply, Installation, testing and commissioning of the following capacity inverter type Hi wall mounted Split Air Conditioner unit with cordless remote, suitable rating plug top including fixing of Indoor & outdoor units, initial gas charging as per manufacturer standards, giving power connection to nearest Power plug point MCS, connecting indoor and outdoor units using hard drawn copper refrigerant pipe insulated with nitrile rubber or equivalent material of minimum 3 mtrs, PVC insulated flexible copper cable of minimum 3 meters as per original manufacturers standards, necessary drain water line using 20mm PVC pipe minimum 3 mtrs.Necessary opening on wall shall be made for drawing refrigerant power / drain lines and shall be restored to normal using cement plastering. (Drain pipe line shall be properly fixed and clamped to line and level as per the direction of site engineer in charge). Make: BlueStar/ Daikin/ Panasonic/ O General/Carrier/Hitachi) 1.0 TR Capacity inverter type 5 star rated working on single Phase 240 V, 50 Hz +/-1% AC supply with 16A plug top, connecting cord etc. including all accessories required etc. complete.
Supply, Installation, testing and commissioning of following capacity split type inverter High wall mounted Air Conditioner unit with cordless remote including fixing of Indoor & outdoor units, initial gas charging as per manufacturer standards, giving power connection to nearest Power plug point / MCS, connecting indoor and outdoor units using hard drawn copper refrigerant pipes insulated with nitrile rubber or equivalent material of minimum 3 mtrs, PVC insulated flexible copper cable of minimum 3 meters as per original manufacturers standards, necessary drain water line using 20mm PVC pipe minimum 3 mtrs. Necessary opening on wall shall be made for drawing refrigerant / power / drain lines and shall be restored to normal using cement plastering. (Drain pipe line shall be properly fixed and clamped to line and level as per the direction of site engineer in charge). Make: BlueStar/ Daikin/ Panasonic/O General/Carrier/Hitachi 1.5TR Capacity inverter type 5 star or above rated working on single Phase 240 V, 50 Hz +/-1% AC supply with 20A plug top
Supply, installation, testing and commissioning of following capacity Split type High wall mounted Cordless remote 4 star or above rated Air Conditioner unit with 20A plug top, cord wire and all fixing accessories including fixing of Indoor & outdoor units, initial gas charging as per manufacturer standards, giving power connection to nearest Power plug point / MCS, connecting indoor and outdoor units using hard drawn copper refrigerant pipes insulated with nitrile rubber or equivalent material of approximately 3 mtrs, PVC insulated flexible copper cable of approximately 3 meters as per original manufacturer standards, necessary drain water line using 20mm PVC pipe approximately 3 mtrs. Necessary opening on wall shall be made for drawing refrigerant / power / drain lines and shall be restored to normal using cement plastering. (Drain pipe line shall be properly fixed and clamped to line and level as per the direction of site engineer in charge).Make: Blue Star/LG/Lloyd/Panasonic /Daikin/Hitachi or quivalent. 2.2 TR or nearest higher capacity inverter type split AC unit working on single phase supply.
Supply & fixing supporting stand / clamp for fixing the outdoor unit using suitable support bars /anchor bolts and safety hook up etc. including all accessories etc. complete (for 1 TR and 1.5TR)
Supply & fixing supporting stand / clamp for fixing the outdoor unit using suitable support bars /anchor bolts and safety hook up etc. including all accessories etc.complete (For 2.2 TR Capacity)
Supply & providing wall mounting type 4 kVA or Higher required capacity Voltage Stabilizer designed for Air conditioning load working on 240V, 50Hz Single Phase AC supply to feed output voltage at +/- 10% tolerance with automatic low voltage & high voltage cutoff, built in thermal overload protection, powder coated enclosure etc. complete good quality and approved make and giving connection. (Approved make: V guard or equivalent reputed brand)
Supply & providing wall mounting type 5 kVA or Higher required capacity Voltage Stabilizer designed for Air conditioning load working on 240V, 50Hz Single Phase AC supply to feed output voltage at +/- 10% tolerance with automatic low voltage & high voltage cutoff, built in thermal overload protection, powder coated enclosure etc. complete good quality and approved make and giving connection. (Approved make: Vguard or equivalent reputed brand)
Supply & drawing additional control cabling of required size as per manufacturer specification between indoor and outdoor units 4C x 1.5 Sq mm Flexible copper Wire
Supply & drawing additional control cabling of required size as per manufacturer specification between indoor and outdoor units 4C x 2.5 Sq mm flexible coppe Wire (For 2.2 TR Capacity)
Supply & laying additional CPVC drain pipe of good quality and suitable size to extend water drain connection till nearest silt terminal as required at site.(For 2.2 TR Capacity)
Supply & providing additional refrigerant lines (both suction and Discharge) using hard drawn copper pipe of the sizes recommended by the manufacturer including suitable thickness nitrile rubber thermal insulation of good quality to extend the refrigerant gas connection till outdoor unit as required at site.(For 1TR & 1.5TR)
Supply & providing additional refrigerant lines (both suction and Discharge) using hard drawn copper pipe of the sizes recommended by the manufacturer including suitable thickness nitrile rubber thermal insulation of good quality to extend the refrigerant gas connection till outdoor unit as required at site.(For 2.2 TR Capacity)
PART B
SITC of Cassette AC units in Personnal and Administration Section
Supply, transportation, leading, lifting to site of 4.0 TR capacity inverter type ceiling mounted 4 star or higher rated 4way Cassette Split Air conditioner working on three phase 415V or single phase 230V 50 Hz AC supply with anti-corrosive copper condenser unit and full charge of refrigerant gas as per OEM .(Make: BlueStar/ Daikin/ Panasonic/ LG/Carrier/Hitachi) standards, wireless remotes, necessary ribbed rubber pads etc. complete as required at site .
Installation, Testing and Commissioning of above said Cassette type AC units (Both indoor and outdoor) including fixing, full charge of refrigerant gas, leak testing/ pressure testing, giving all power/control/refrigerant connections etc. and all required works as per prevailing code of standard.
Supply & laying refrigerant lines (Both suction and discharge) using hard drawn copper pipe of the adequate size recommended by the manufacturer for above 4.0 TR AC unit including duly insulated with 19mm XLP nitrile rubber thermal insulation of recommended capacity and all other materials required as per prevailing standards, clamping to wall, supports required etc. complete as required at site.
Supply & fixing supporting stand / clamp for fixing the outdoor unit using suitable support bars/anchor bolts and safety hook up etc. including all accessories etc.complete
Supply and Laying 25mm PVC pipe in position for condensate drain water from indoor unit drain to the floor trap piping with 19mm thick nitrile rubber insulation and with necessary fittings like elbows, tees and reducers, clamping in proper interval etc. complete with required wall openings and making as good as same
Supply & drawing 4C x 2.5 Sq.mm control cable of recommended by the manufacturer between indoor and outdoor unit
Buy back of existing 1.5 TR split AC unit installed in Server room at Computer Section (Not working)
Buy back of existing windowAC unit installed in DMP Cabin at P&A Section in working condition
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .