Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹9.1 Cr
EMD Value
₹9.1 L
Closing Date
22 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer, Kheda R. & B. Division, at Nadiad
Construction of New I.T.I. Building at Kathlal (District Kheda)
351233
NIT-20 of 2026-27
Open
Civil Works - Buildings
Works
Nadiad
15 documents required · 15 mandatory
₹12,000
Executive Engineer Kheda R&B Division at Nadiad
₹9.1 L
1 Oct 2026
1 Oct 2026
1 Oct 2026
22 Oct 2026
1 Oct 2026
Name of Work :: Construction of NEW ITI Building At Kathlal Dist: Kheda
Bill of Quantities (BOQ)
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[1] Excavation for foundation upto 1.5 m depth including sorting out 3150.80 Cum 117.08
and stacking of useful materials and disposing off the excavated
stuff upto 50 Meter lead.(A) Loose or soft soil
[2] Excavation for foundation for depth from 1.5 m to 3.0 m including 1774.00 Cum 162.38
sorting out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(B) Dense or Hard soil
[3] Filling available excavated earth (excluding rock) in trenches. 3209.00 Cum 130.39
plinth, sides of foundations etc. in layers not exceeding 20 cm. in
depth consolidating each disposited layer by ramming and
[4] Filling in foundation and plinth with murrum or selected soil in 816.00 Cum 282.02
layers of 20cm. thickness including watering, ramming and
consolidating etc. complete.
[5] Filling in plinth with sand under floors including watering ramming, 474.00 Cum 460.18
consolidating and dressing complete
[6] Applying general insecticide pest control treatment to floors, 2145.00 Sqm 89.28
cupboards etc including labour materials etc. complete. Using
Imidacloprid 30.5 SCas Per IS 6313 part -II( (0.075% concentration
by mass) is recommended 10.5ml chemical diluted with 5 liters of
water application 0.5 litre chemical /Sqm of surface is
recommended as per I.S.
[7] Providing and laying cement concrete 1:3:6 ( 1 cement: 3 coarse 545.16 Cum 3172.05
sand: 6 crushed stone aggregate 40 mm nominal size ) and curing
complete excluding cost of form work & including all in foundation
[8] Providing and laying controlled cement concrete M.150 for curing 498.00 Cum 3860.16
complete excluding cost of formwork and reinforcement for
reinforced concrete work in (A) Foundations, footings,Base of
columns and Mass concrete
[9] Providing and laying controlled C.C.M.250 & curing complete 847.00 Cum 4502.04
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in foundation,
footing bases of columns and the like and mass concrete
[10] Providing and laying controlled C.C. M.250 & curing complete 82.00 Cum 7604.02
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work including all .in
Columns upto Plinth
[11] Providing and laying controlled cement concrete M-250 and curing 341.00 Cum 5800.73
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Plinth BEAMS
[12] Providing and laying controlled C.C. M.200 & curing complete 106.00 Cum 7549.79
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Columns for
[13] Providing and laying controlled C.C. M.200 & curing complete 61.00 Cum 7589.58
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Columns for FIRST
[14] Providing and laying controlled C.C. M.200 & curing complete 22.00 Cum 7629.38
including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in Columns for
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[15] Providing and laying controlled cement concrete M.200 and curing 208.00 Cum 6073.26
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in Beams
[16] Providing and laying controlled cement concrete M.200 and curing 204.00 Cum 6113.05
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in Beams First
[17] Providing and laying controlled cement concrete M.200 and curing 7.00 Cum 6152.84
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in Beams
[18] Providing and laying controlled cement concrete M.200 and curing 20.41 Cum 7446.85
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in Lintel /
Coping Ground Floor
[19] Providing and laying controlled cement concrete M.200 and curing 19.00 Cum 7486.64
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in Lintel First
[20] Providing and laying controlled cement concrete M.200 and curing 1.00 Cum 7526.43
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in Lintel
[21] Providing and laying controlled cement concrete M.200 and curing 27.00 Cum 8069.37
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in CHHAJJA
including finishing coat CM (1:3) for chhajja plaster Ground Floor
[22] Providing and laying controlled cement concrete M.200 and curing 11.00 Cum 8109.16
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in CHHAJJA
including finishing coat CM (1:3) for chhajja plaster First Floor
[23] Providing and laying controlled cement concrete M.200 and curing 1.00 Cum 8148.96
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in CHHAJJA
including finishing coat CM (1:3) for chhajja plaster Second Floor
[24] Providing and laying controlled cement concrete M.200 and curing 267.35 Cum 6128.46
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in SLAB Ground
[25] Providing and laying controlled cement concrete M.200 and curing 254.00 Cum 6168.26
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in SLAB First
[26] Providing and laying controlled cement concrete M.200 and curing 7.00 Cum 6208.05
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in SLAB Second
[27] Providing and laying controlled cement concrete M.200 and curing 5.00 Cum 6651.55
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in Staircase Ground
[28] Providing and laying controlled cement concrete M.200 and curing 5.00 Cum 6691.34
complete including the cost of formwork but excluding the cost of
reinforcement for reinforced concrete work in Staircase First Floor
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[29] Providing and laying controlled cement concrete M.200 and curing 28.00 Cum 8738.84
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in RCC Wall -
[30] Providing and laying controlled cement concrete M.200 and curing 1.00 Cum 8778.63
complete including the cost of formwork and but excluding the
cost of reinforcement for reinforced concrete work in RCC Wall -
[31] Providing TMT Bar FE 500D reinforcement for R.C.C. work including 223850.00 Kg 76.21
bending, binding and placing in position complete upto Ground
[32] Providing TMT Bar FE 500D reinforcement for R.C.C. work including 71420.00 Kg 77.21
bending, binding and placing in position complete upto First Floor
[33] Providing TMT Bar FE 500D reinforcement for R.C.C. work including 8350.00 Kg 78.21
bending, binding and placing in position complete upto Second
[34] Providing and applying a uniform coat of residual petroleum 3436.00 Sqm 161.60
bitumen of approved quality at the rate of 1.7 kg per square metre
on the damp proof course (DPC) surface, including thorough
cleaning of the surface with brushes and final wiping with a piece
of cloth lightly soaked in kerosene oil to remove dust, dirt, and
loose particles, complete as directed by the Engineer-in-Charge.
[35] Brick work using common burnt clay building bricks having 224.15 Cum 4021.02
crushing strength not less than 35 kg./Sq.Cm. in foundation and
plinth in Cement Mortar 1:6 (1- Cement : 6 -fine sand)(B)
[36] Brick work using common burnt clay building bricks having 497.00 Cum 4289.32
crushing strength not less than 35 kg./Sq.Cm. in Super Structure
superstructure above plinth level in Cement Mortar 1:6 (1-
Cement : 6 -fine sand) (B) Conventional for Ground Floor
[37] Brick work using common burnt clay building bricks having 250.00 Cum 4329.51
crushing strength not less than 35 kg./Sq.Cm. in Super Structure
superstructure above plinth level in Cement Mortar 1:6 (1-
Cement : 6 -fine sand) (B) Conventional for First Floor
[38] Brick work using common burnt clay building bricks having 85.00 Cum 4369.70
crushing strength not less than 35 kg./Sq.Cm. in Super Structure
superstructure above plinth level in Cement Mortar 1:6 (1-
Cement : 6 -fine sand) (B) Conventional for Second Floor
[39] Half brick masonry in common brunt clay building bricks having 434.00 Sqm 641.16
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:5
(1- Cement : 5 -coarse sand ) in superstructure above plinth level
(B) Conventional for Ground Floor
[40] Half brick masonry in common brunt clay building bricks having 646.00 Sqm 647.16
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:5
(1- Cement : 5 -coarse sand ) in superstructure above plinth level
(B) Conventional for First Floor
[41] Providing and laying cement concrete 1:4:8 (1- Cement : 4- Coarse 59.00 Cum 2658.40
sand : 8- Graded Brick bats aggregate 40mm normal size) and
curing complete excluding cost of formwork in Sunk Filling
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[42] Providing and fixing G.I. hexagonal chickenmesh of size 20mm x 779.00 Sqm 178.45
20mm of 24 gauge at junction of concrete and brick work or
between different materials after making "V" grove between two
different material surface and filled with rich cement mortar and
@ 100mm on each side of surfaces including necessary "U" nails /
screws / washers with cleats for fixing, overlaps, scaffolding at all
floors / all levels / all heights / all shapes etc. complete as per
drawing / specifications and direction of Engineer-in-charge.
[43] Providing and fixing in position collapsible steel shutters with 7.00 Qtl. 5825.33
vertical channels 20 x 10 x 2 mm braced with flat iron diagonals
x 5 mm size with top and bottom rails of T_rin 40x 40 x 6 mm with
38mm dia, steel pulleys complete with bolts, nuts, locking
arrangements, stoppers handles including applying a priming coat
of red lead paint.
[44] Providing and fixing door having side hung double shutter having 44.00 Sqm 3477.84
factory fabricated std. Extruded aluminium colour anodized hollow
section (Section 63.50 x 38 mm x 2.50 mm thick ) for door frame,
hollow portion of door frame shall be filled with non teak wood
wood, with factory made 35 mm. Thick flush door both side pre
laminated with Special Type Alluminum Beading around shutter.
SS Aldrop, SS Handle size 15 Cm Long, Tower Bolt size 20 cm etc, as
per detail colour & pattern approved by this office including
necessary anodized alluminum fixtures and fastenings.
[45] Providing and fixing door having side hung single shutter having 63.00 Sqm 3299.40
factory fabricated std. Extruded aluminium colour anodized hollow
section (Section 63.50 x 38 mm x 2.50 mm thick ) for door frame,
hollow portion of door frame shall be filled with non teak wood
wood, with factory made 35 mm. Thick flush door both side pre
laminated with Special Type Alluminum Beading around shutter &
6 Lever Mortice lock (Godrej or Equivalent), SS Aldrop, SS Handle
size 15 Cm Long, Tower Bolt size 20 cm etc. as per detail colour &
pattern approved by this office including necessary anodized
alluminum fixtures and fastenings.
[46] Providing and fixing FRP frame size 100x50 mm and 28mm thick 22.00 Sqm 2615.53
FRP depress panel having double shutter having extra
reinforcement on sides & edges in Gel coat finish. The core of the
shutter & frame is to be filed up with injected fire retardant grade
polyurethene foam done in situ alongwith embedded wooden
pieces for stiffening & also taking hinges & fintures. The whole FRP
frame & shutter is to be water proof weather proof, termite proof
& resistance to mild acid/alkali. Rates are to be inclusive of S.S
hinges with necessary screws & alluminium fixtures & fastenings &
fastener sleeve.
[47] Providing and fixing FRP frame size 100x50 mm and 28mm thick 23.70 Sqm 2377.76
FRP depress panel shutter having extra reinforcement on sides &
edges in Gel coat finish. The core of the shutter & frame is to be
filed up with injected fire retardant grade polyurethene foam done
in situ alongwith embedded wooden pieces for stiffening & also
taking hinges & fintures. The whole FRP frame & shutter is to be
water proof weather proof, termite proof & resistance to mild
acid/alkali. Rates are to be inclusive of S.S hinges with necessary
screws & alluminium fixtures & fastenings & fastener sleeve.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[48] Providing and fixing window having extruded aluminum Colour 300.00 Sqm 1583.95
anodized section frame main outer size 95mm x 24mm x 1.17mm
@ wt.of 0.738 Kg/mt , horizontal Three track member size 92mm x
31.75mm x 1.30mm,@ Wt.1.07 Kg/mt , vertical member of size
92mm x 31.75mm x 1.50mm @ Wt. 1.06 Kg/mt with sliding
shutters of horizontal member size 40 mmx18mm x1.29mm @
wt.of 0.456 Kg/mt, vertical member of size 40mm x 18mm x
mm @ wt.of 0.456Kg/mt/ with 5 mm thick transparent bronze
colour tinted float glasswith powder coated aluminum fittings and
transparent silicon sealant glass fixing to frame as per details etc
[49] Providing and fixing window having extruded aluminum Colour 22.10 Sqm 1713.69
anodized section frame main outer size 63.50 x 38.10 x 1.95 mm,@
Wt 1.094 Kg / Rmt, horizontal two track member size 61.85 mm x
31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt, vertical member of size
61.85 mm x31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding
shutters of horizontal member size 40mm x 18mm x 1.29mm @
wt.of 0.456Kg/mt, vertical member of size 40mm x 18mm x
1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm thick
transparent bronze colourtinted float glass with powder coated
aluminum fittings and fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for window.
[50] Providing and fixing colour anodised Aluminium section fixed glass 11.30 Sqm 1829.94
windows using section 63.50 x 38.10 ( W0.758 Kg/Rmt for One size
groove and 0.761 Kg /Rmt. Both side Groove Fully glazed 5 mm
thick transparent glass & 0.8mm th.alluminium glazing clips and
rubber bedding and including anodized aluminum fixtures and
fastenings and hold fasting with coach bolts etc complete. (Colour
as directed by Engineer in charge except black)
[51] Providing and fixing colour anodised Aluminium sectional 16.60 Sqm 2193.66
ventilators using section 50.80 x 25.40 (Section Wt 0.791 Kg /Rmt.)
5 mm thick transparent glass louvers fixed in alluminum channel
and including anodized aluminum fixture and fastenings and hold
fasting with coach bolts etc complete. (Colour as directed by
Engineer in charge except black )
[52] Providing and fixing Safety grill with Rat Mesh Using M.S. Pipes 75 235.80 Sqm 3131.17
x 25 x 1.5 mm thick at required spacing as per design and hold
fasting with coach bolts including one coat of primer and two coats
of matt finish oil painting etc complete.
[53] Providing and fixing approved quality Precast Concrete Jali of 235.80 Sqm 212.10
specified size, pattern and thickness, manufactured from cement
concrete of approved grade, including casting, curing,
transportation, handling, hoisting, placing in position, fixing with
cement mortar as required, finishing, and all materials, labour,
tools, plants, scaffolding and incidental charges necessary to
complete the work in all respects as per approved drawings and
the directions of the Engineer-in-Charge.
[54] Providing and fixing M.S. grills of required pattern to wooden / 8572.00 Kg 107.36
stone frames of windows etc. with M.S. flats at required spacings
and frame alround, square or round bars with round headed bolts
and nuts or by screws including one coat of primer and two coats
of matt finished oil painting etc complete.
[55] Providing and fixing Mirror polished GRANITE stone slab 18 mm 578.78 Sqm 3150.36
thick (selected colour and shade) for For Doors / WIndows cill &
Jambs Clading as per design incl. full moulded round both edge on
10 mm thick cement mortar 1:3 (1 -cement : 3 coarse sand )
jointed with grey cement slurry including rubbing and polishing
etc. complete as per instruction of Engineer In Charge.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[56] Providing and laying polished GRANITE stone slab 18 mm thick 111.70 Sqm 2279.37
with moulded edge (selected colour and shade) slab flooring over
20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-
coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid
over and jointed with grey cement slurry mixed with pigment to
match the shade of slab including rubbing and polishing etc.
[57] Providing & Laying 600 X 600 X 10 MM THICK GLAZED VITRIFIED 647.51 Sqm 1248.74
TILES FLOORING ( colour & shade/details as approved by architect
, approx. 10% dark colour tiles for pattern of the same material)
over 20 mm (average) base of cement mortar 1:6 ( 1 cement:
coarse sand) on new surface or fixing on existing flooring by
adhesive material including dismentaling of existing flooring and
jointed with color cement slurry including finised with flush
pointing & cleaning the surface etc. complete
[58] Providing and laying 600 X 600 X 10 MM THICK GLAZED VITRIFIED 51.32 Sqm 1141.45
TILES FLOORING ( colour & shade/details as approved by architect
, approx. 10% dark colour tiles for pattern of the same material) in
skrting risers of steps and dedo on 10mm thick cement plaster 1:3
(1-cement : 3-coarse sand) and jointed with white cement slurry
etc. complete as per instruction of Engineer In Charge.
[59] Providing & Laying 600 X 600 X 10 MM THICK SOLUBLE SALT 1024.00 Sqm 1498.49
VITRIFIED TILES FLOORING ( colour & shade/details as approved by
architect , approx. 10% dark colour tiles for pattern of the same
material) over 20 mm (average) base of cement mortar 1:6 (
cement: 6 coarse sand) on new surface or fixing on existing
flooring by adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including finised with
flush pointing & cleaning the surface etc. complete
[60] Providing and laying 600 X 600 X 10 MM THICK SOLUBLE SALT 47.00 Sqm 1369.74
VITRIFIED TILES FLOORING ( colour & shade/details as approved by
architect , approx. 10% dark colour tiles for pattern of the same
material) in skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white
cement slurry etc. complete as per instruction of Engineer In
[61] Providing and laying 200 mm thick Ironite flooring in cc (M-200) 711.00 Sqm 907.97
laid in Ist layer of 188 mm thick 2nd layer of Ironite material
kg/m of 12mm thick mixing with ratio of 1:4 with dry cement
finished with 3 phase Trimax floater disc incl. material, labour and
as per following method in expansion joint at 30 mt. c/c as per
instruction Method of Ironite mixing: Mix well Ironite & cement in
dry condition & take one part by volume of the above mixel
material and two volume of grit 6mm to 2mm size & mix well in
dry condition the grit should be of hard stone clean & without
dust. Add water 80 litres to 90 liter (Ratio 0.4 to 0.45) water should
be clean portable & non Acidic. Method of before laying:Surface of
the granolithic layer must be rough and without water on the
surface. At the time of laying Initial setting i.e. if ceases the thumb
impression control of quantity of water take care to see the Ironite
is mixed properly and evenly in the mix. After layingSee that it is
properly leveled after formal setting of flooring keep the are of the
flooring under water for 8 to 10 days before use and necessary
instructions by Architect. Machine mixed and floater Dish finished
Ironite. (200 mm thick concrete mixture machine and vibrator is
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[62] Providing and laying Hand dressed polished blue Kota stone slab 559.00 Sqm 1090.44
flooring over 20mm (Average) thick base of cement mortar 1:6 (1-
cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse
sand) laid over and jointed with grey cement slurry mixed with
pigment to match the shade of slab including rubbing and
polishing etc. complete. (A) 25mm thick
[63] Providing and laying 300X300 MM & 10 MM THICK MATT FINISHED 131.00 Sqm 908.32
CERAMIC TILES in flooring treads of steps and landing laid on a
bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand )
finishing with flush pointing in white cement.
[64] Providing and laying 600X300 MM & 10 MM THICK GLAZED TILES 371.00 Sqm 1417.36
DADO in skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white
[65] Providing 20 mm THICK DOUBLE COAT MALA PLASTER WITH 3355.00 Sqm 270.42
10MM GROOVES AT JUNCTION OF STRUCTURAL MEMBERS on
interior brick / concrete work for plastering comprising of base
coat of 12 mm thick cement plaster in cement mortar (1 Cement :
4 coarse sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel
including scaffolding curing etc. complete.
for Ground Floor level
[66] Providing 20 mm THICK DOUBLE COAT MALA PLASTER WITH 3783.00 Sqm 296.36
10MM GROOVES AT JUNCTION OF STRUCTURAL MEMBERS on
interior brick / concrete work for plastering comprising of base
coat of 12 mm thick cement plaster in cement mortar (1 Cement :
4 coarse sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel
including scaffolding curing etc. complete.
for First Floor level
[67] Providing 20 mm THICK DOUBLE COAT MALA PLASTER WITH 555.00 Sqm 322.30
10MM GROOVES AT JUNCTION OF STRUCTURAL MEMBERS on
interior brick / concrete work for plastering comprising of base
coat of 12 mm thick cement plaster in cement mortar (1 Cement :
4 coarse sand) in rough finishing and 8 mm thick top coat of
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel
including scaffolding curing etc. complete.
for Second Floor level
[68] Providing 10mm thick cement plaster in single coat on 1827.45 Sqm 169.25
brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-
sand) for plastering on ceilings and sofits of stairs Ground Floor
[69] Providing 10mm thick cement plaster in single coat on 1673.00 Sqm 192.01
brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-
sand) for plastering on ceilings and sofits of stairs First Floor Level
[70] Providing 10mm thick cement plaster in single coat on 80.00 Sqm 214.76
brick/concrete walls for interior plastering upto floor two level and
finished even and smooth in (i)Cement mortar 1:3 (1-cement:3-
sand) for plastering on ceilings and sofits of stairs Second Floor
[71] 20mm THICK DOUBLE COAT SAND FACED CEMENT PLASTER WITH 4085.40 Sqm 335.65
GUTKA FINISH WITH 18MM WIDE & 10MM DEEP GROOVES AS PER
ELEVATIONS ( SAMPLES TO BE APPROVED BY ARCHITECTS ) on
walls upto height 10 metres above ground level consisting of
12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm
thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
Ground + Fisrt + Second Floor level
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[72] Applying two coats of putty & two coats of water based primer of 11438.92 Sqm 40.59
approved brand and manufacture on new wall surface to give an
even shade including thoroughly brushing the surface free from
mortar dropping and other foreign matter and sand papered
[73] Wall painting (three coats) with plastic emulsion paint (shade and 7835.00 Sqm 119.42
colour to approved by chief architect office,gandhinagar )of
approved brand and manufacture on undecorated wall surface to
give an even shade including throughly brushing the surface free
from mortar droppings and other foreign matter and sand
papered smooth.
[74] Wall painting (three coats) with plastic emulsion paint (shade and 3603.92 Sqm 124.68
colour to approved by chief architect office,gandhinagar )of
approved brand and manufacture on undecorated wall surface to
give an even shade including throughly brushing the surface free
from mortar droppings and other foreign matter and sand
papered smooth. for painting on ceilings and sloping roofs.
[75] Applying one coat of Exterior Primer of approved brand and 5206.40 Sqm 67.84
manufacture on new wall surface to give an even shade including
thoroughly brushing the surface free from mortar dropping and
other foreign matter and sand papered smooth.
[76] Finishing wall with TWO COATS OF 100% WEATHER PROOF 5206.40 Sqm 114.53
ACRYLIC EMULSION WATER REPELLANT PAINT (shade and colour
to approved by chief architect office,gandhinagar ) on wall surface
(two coats) to give an required shape even shade after thoroughly
brushing the surface to remove all dirt, and remains of loose
powdered materials.etc complete
[77] Providing and laying water proofing treatment with china mosaic 1745.00 Sqm 1125.04
tiles flooring over avg. 50 mm thick C.C. 1:2:4 {1 Cement : 2 sand :
4 Kapachi / Gritt 6 to 12 mm size} bedding for maintaining slope
for plain and curve surface & 12 mm to 20 mm of broken piece of
seramic / glazed tiles ( one for more color as directed ) to be laid
over cement mortar bedding of C M 1:3 (1 cement : 3 sand )
containg one Kg of water proofing materials per bag of O P C at
plain or / and slops and to be tempered to bring mortar ceramic
up to surface with using white cement and colour pigment
including rounding of junctions and extending them up to 15 cm
along the wall and curing with bends any pattens or design as per
drawing and cleaning by using oxalic acid etc complete.
[78] Providing and fixing M.S. Railing for top of stair railing made from 40.00 Rmt 546.96
50 mm dia 2.90 mm thick M.S. Round pipe with 35 mm Square
pipe for support as per detailed drawings including matt finish oil
painting etc. complete
[79] Providing and fixing concealed center point to wall ceiling & floor 50.00 Rmt 166.86
CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal bore tube fittings
and clamps including making good the wall, ceiling and floor etc.
complete.[A] 15 mm.
[80] Providing and fixing concealed center point to wall ceiling & floor 80.00 Rmt 249.72
CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF)
seal for potable water of following dia. nominal bore tube fittings
and clamps including making good the wall, ceiling and floor etc.
complete. [C] 25 mm.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[81] Providing laying and jointing in true line and level 15mm dia. 100.00 Rmt 72.65
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
[82] Providing laying and jointing in true line and level 25mm dia. 190.00 Rmt 91.84
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
[83] Providing laying and jointing in true line and level 40mm dia. 190.00 Rmt 148.12
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
[84] Providing laying and jointing in true line and level 50mm dia. 410.00 Rmt 195.67
U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as
approved by Engineer In Charge. Pipe shall be fixed on the wall
with the help of clamp at every two metre C/C or shall be
concealed as directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
[85] Providing, laying and jointing in true line and level 110 diametre 340.00 Rmt 835.15
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size 110 mm
diametre x 149 mm length x 145 mm heigh at every 2000 mm
center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement
including cost of all materials.
[86] Providing and fixing to wall ceiling and floor 10.0 Kg. F/Cm2 50.00 Rmt 277.43
working pressure polythene pipes of the following outside Dia.
Low densidy, complete with special falnge compression type
fittings, wall clipsetc. including making good the wall ceiling and
[87] Providing laying (to level or slopes) and jointing reinforced 220.00 Rmt 240.20
concrete Light duty non-pressure pipes I.S. class NP2 of the
following internal diameter with collars and butt ends prepared for
collar joints including testing of joints complete.(B) 150mm
[88] Constructing brick masonry chamber for underground C.I. 30.00 Each 2932.93
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm intenal dimensions total weight of
cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.)
and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement
:2- coarse sand :4-graded stone ggregate 20mm size) foundation
concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on walls and
bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm
and 450mm deep for single pipe line.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[89] Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 28.00 Each 558.36
mm diameter with jali of the following nominal diameter of self
cleansing design with C.I scread down or hinged grating including
the cost of cutting and making good the walls.
[90] Providing and fixing screw down bib taps of following size.(B) Brass 14.00 No 186.83
chromium plated screws down Bib Tap. (i) 15mm dia.
[91] Providing and Fixing C.P. Pillar cock 15 mm Ø Heavy duty swan 17.00 Each 799.45
neck including fixing with CP brass nipple including all labour &
material etc. complete as per instruction of Engineer In Charge.
[92] Providing and Fixing C.P. Angle stop cock 15 mm Heavy duty with 14.00 Each 558.92
cap including all labour & material etc. complete as per instruction
of Engineer In Charge.
[93] Providing and fixing wash basin with single hole for pillar tap with 14.00 Each 1653.67
C.I. or M.S. brackets painted white including sutting holes and
making good the same with brass union and CP brass wall
discharge pipe with flanges and cap of best quality brand , Waste
Pipe for Wash basin C.P. 32 mm dia with fittings up to floor trap,
32mm dia CP brass waste coupline with CP chain and rubber plug,
washer and CP brass cap complete in all respects including cutting
and making good the walls RCC work as directed and making good
the same etc. complete.
A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size.
(i) In white colour.
[94] Providing and fixing WALL HUNG EWC WITH CROFT SOFT CLOSE 18.00 Each 8727.86
SEAT COVER & SNOW WHITE COLOUR-535 X 360 X 335 MM with
integral "P" and "S" trap including jointing the tra best quality
brand including providing and fixing plastic seat cover for wash
down WC with CP brass hinges and rubber buffers back plastic seat
and including providing 12.50 Litres low level flushing cisten with a
"P" air of CI or MS bracket with complete fitting such as lead valve
Sipron 15mm dia brass ball valve with polythene float CP brass
handle, unions and couplings for connection with inlet outlet and
overflow pipes 40mm dia porcelain enamelled flush bend,
including jet spray operated with necessary valve of best quality
brand including cutting holes in walls and making good the same
connecting the flush bend with cistern and closet vitreous china
[95] Providing and fixing Concealed cock 15 mm Ø Heavy duty with cap 14.00 No 675.38
[96] Providing and fixing S.W. gully trap with C.I. grating brick masonry 15.00 Each 1292.19
chamber and water tight C.I. cover with frame of 300mm x 300mm
size (inside) with standard weight.(i) Square mouth traps. (A)
100mm x 100mm size P type.
[97] Providing erecting and fixing double coated ISI water tank of 20000.00 litre 3.95
required capacity each with all necessary fittings and connection
etc. complete on terrace
[98] Providing and fixing in position cowel went to pipes.(C) 100mm dia 2.00 No 501.87
[99] Providing and fixing Urinal or approved quality including conecting 6.00 Each 1036.27
the Urinal with waste pipe , tap etc. complete.(A) White
earthenware flat back or corner type size 430mm x 260mm x
[100] Providing and laying Both side mirror polished Granite marble 7.00 Sqm 2107.11
stone slab 18 mm (Average) thick of approved quality incl. Full
moulded round front edge fixed in wall for partition and jointed
with grey cement slurry including rubbing and polishing
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[101] Providing and Fixing 18 mm thick in polished granite shelves / 220.00 Sqm 2008.65
Counter with extra outer edge 50 mm x 19 mm strip as per
drawing with full round moulded edge resting on wall fix and
jointed with white cement slurry including rubbing, polishing,
labour charges, finishing etc. complete as directed.
[102] Providing and fixing 600mm x 450mm bevelled edge mirrror of 12.00 No 833.73
superior glass mounted on 6mm thick A.C. sheet or plywood sheet
and fixing to wooden pluge with C.P. brass screws and washers.
[103] Providing and fixing C.P. brass towel rail comlete with C.P. brass 4.00 No 603.19
brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x
[104] Providing and fixing C.P. Towel Ring Square or round shape of 4.00 No 1352.74
Good Quality Brand as directed by Engineer in charge including
fixing as and where directed etc. complete.
[105] Constructing Sandwitch Platform of 18 mm thick Polished Black 10.70 Sqm 6512.34
Granite at top & both end side vertical polished black granite of
height 4 - 5 ft, Front edge of 4" wide 18 mm thick Polished Black
Granite Edge, Wall side of 4" wide 18 mm thick Polished Black
Granite Edge and 30 mm thick Kota stone slab flooring fitting at
bottom with cementing Materials / adhsives including macking
necessary grooves in walls with Vertical Kotastone 30 mm x 2 No
sandwitch thick every 60 cm centre to centre including all labour
material of approved quality incl. full moulded round front edge of
granite & fixed in wall for partition and jointed with grey cement
slurry including rubbing and polishing etc. complete
[106] Providing and fixing SS Sink Glosy ASIS 304 Grade x 1mm thick with 2.00 No 2643.47
over all size 610 x 460 mm & bowl size 560 x 410 x 200 with single
hole for pillar tap Fixing in sandwich platform including cutting
holes and making goods the same, necessary fixtures, connections
and waste pipes etc complete
[107] Providing and fixing Heavy Handle valve of aprroved brand & 12.00 Each 440.16
follwing internal dia of Brass including fixing in pipe lines
etc.complete (A) 15 mm Dia
[108] Providing and fixing Heavy Handle valve of aprroved brand & 12.00 Each 510.86
follwing internal dia of Brass including fixing in pipe lines
etc.complete (A) 25 mm Dia
[109] Providing and fixing Heavy Handle valve of aprroved brand & 12.00 Each 682.56
follwing internal dia of Brass including fixing in pipe lines
etc.complete (A) 40 mm Dia
[110] Providing and fixing Butterfly valve of aprroved brand & follwing 8.00 Each 970.41
internal dia of Brass including fixing in pipe lines etc.complete (A)
[111] Providing and fixing Butterfly valve of aprroved brand & follwing 4.00 Each 1186.90
internal dia of Brass including fixing in pipe lines etc.complete (A)
[112] Provding P.V.C. 100 mm diameter water spouts including 6.00 Each 159.37
necessary iron gratings as per drawings.
[113] Providing and fixing rolling shutters of approved make made of 80 123.00 Sqm 3503.41
mm wide M.S. laths inter-locked together through their entire
length and jointed together at the ends by end locks mounted on
specially designed pipe shaft with bracket plates, guide channels
arragements for inside and outside locking with push-pull
operation including the cost of hood cover and spring etc.
complete.(A) Shutters having width below 3.5 M.
[114] Providing and laying and fixing 50 mm thick expansion joint by 119.00 Sqm 1491.03
hydro cell semi rigid UV resistance with high performance
laminated closed cell polythene foam joint filler in sheet foam as
directed, etc. complete.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[115] Providing and filling the expansion joint by polymer confirm to BS 29.00 Sqm 515.39
4254-1983 as per required shade and specifi-cation by making
groove of 50 mm x 12.5 mm lather by cutting or by repairing
groove and removing mortar drop or any other foreign materials
applying primer and filling required size (oversize of joint PU foam
[116] Providing and fixing 25 cm Wide & 3mm thick exterior composite 62.00 Sqm 1054.34
panel on existing expansion joint horizontally & vertically with all
material, hardware, acessories & fittings etc completed.
[117] Providing and fixing copper strip and holdfasts for to cover 39.00 Rmt 10293.88
expansion joint Copper sheet of 1.25 mm. thick and of 1250 mm.
width with the 'U' shape in the middle, Copper strip shall have
holdfast of 3 mm. diameter copper rod fixed to the plate soldered
on strip at intervals of about 30 cm. etc complete.
[118] Providing throating or plaster drip and moulding to R.C.C. Chhajja. 521.00 Rmt 41.00
[119] Providing 12 mm wide groove / notch in plaster including finishing 1905.00 Rmt 17.17
the same etc. complete for all height.
[120] Providing and fixing in position 300 mm high. 150 mm wide English 40.00 No 813.05
letters made from 1.0 mm thick stainless steel sheet as directed by
Engineer-in-charge with all necessary tools & plants etc. complete
[121] Providing and fixing in position 150 mm high, English letters made 100.00 No 464.60
from 1.0 mm thick stainless steel sheet as directed by Engineer-in-
charge with all necessary tools & plants etc. complete
[122] Providing and fixing acrylic/ PU foam signages of various sizes 45.00 Sqm 1045.35
including using of reflective letter etc complete by engineer
[123] Providing and fixing railing of M.S. square pipe as per pattem 24.00 Sqm 1925.83
121200 suggested by Engineer In Charge including providing out
vertical top and middle square pipes of 40 m and intermediat
horizontal and vertical square pipe of 20 mm size including cutting,
welding, Jointing and fixing on site including painting two coats
[124] Providing and fixing steel cupboard having frame of 40 mm x 40 63.00 Sqm 2851.00
mm x 5 mm M.S. angle double door shutter of CRC plate of
gauge (1.219 mm thickness) with 30 mm x 30mm x 3 mm angle
framing at top and bottom edge of shutter 10 mm x 10 mm square
M.S. bars 2 No. vertical and 40 mm x 3 mm M.S. flat at one edge of
each shutter and for lock along with one coat of red oxide and two
coats of spray oil painting of approved brand and colour shade and
locking arrangement etc complete as directed by Engineer in
[125] Providing, Fabricating & Fixing wall signage using 304 grade 10.00 No 1141.92
Stainless steel brushed steel finish plate of 1.5 mm thick fixed on a
wall using s.s studs including punched (laser cut) lettering carried
out on s.s plate of required size and text as directed by Engineer
over the S.S plate etc.complete. Size: 18" x 6"
[126] Providing, Fabricating & Fixing 304 grade Stainless steel 1.5 mm 60.00 No 747.92
thick brushed steel finish plate fixed on a door using s.s studs and
with punched(laser cut) lettering carried out on s. plato of
required size and text as directed by Engineer autocomplete Size:
[127] Providing 15mm thick cement plaster in single coat on Rough 1317.47 Sqm 194.07
(Similar)side of single or half brick walls for interior plastering upto
floor two level and finished even and smooth in (i) Cement mortar
1:3 (1-cement:3-sand)
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[128] Providing and fixing M.S. grills / Gates of required pattern to brick 594.00 Kg 145.05
walls / Columns prepared with M.S. flats, angles, Square / round
bars, square pipes, at required spacings with necessary hold fasts
as per detailed drawingand fixing brick wall / coping / columns etc.
complete including painting two coat & applying primer coat. (A)
Ornamental Grill
[129] Constructing cattle trap made from ISMC 100 border and G.I. pipe 11.00 Sqm 3871.50
50 mm dia HEAVY DUTY at 12 cm spacing by welding and
necessary support of I.S.M.B. 100 x 75 x 6 section Fixing in prepard
chamber as per drawing by necessary arrangement etc. complete .
[130] Providing and fixing 0.90 m high fencing with M.S. angle posts of 379.00 Rmt 353.50
size 40 mm × 40 mm × 6 mm, fixed at 2.50 m centre-to-centre,
including three coats of oil painting. The fencing shall consist of
three horizontal lines and two diagonal lines of galvanised steel
barbed wire weighing 9.38 kg per 100 m, along with razor wire of
0.5 mm blade thickness and 2.5 mm core wire, with coil diameters
ranging from 300 mm to 1500 mm. The barbed wire and razor wire
shall be properly strained and fixed to the posts using G.I. staples,
including fixing the posts on the compound wall, complete in all
[131] Providing 20 mm thick cement plaster in single coat on brick / 84.00 Sqm 259.87
concrete wall for interior plastering up to floor two level finished
even and smooth (ii) Cement mortar 1:3 ( 1-cement ,3 - sand ) and
mixing waterproofing materials in cement mortar in proportion
recommended by the manufacturer for All Floor.s etc. all complete
as directed by engineer in charge.
[132] Providing cement vata (10cm. x 10 cm. size) quarter round in 32.00 Rmt 23.68
cement mortar 1:1 including neat cement finishing, watering etc.
[133] Providing and laying 300X450 MM & 10 MM THK GLAZED TILES 60.00 Sqm 1484.60
DADO in skrting risers of steps and dedo on 10mm thick cement
plaster 1:3 (1-cement : 3-coarse sand) and jointed with white
[134] Steel work, welded in built up sections framed work including 3.60 Qtl. 9725.85
cutting, hoisting, fixing in position and applying a priming coat of
red lead paint. (D) In trussses and trussed purlins, upto 25 M. span
and 15 M. ovarall height.
[135] Clearing and grubbing road land including uprooting rank 1.12 Hect 28393.04
vegetation grass bushes, shrubs, sapling and trees girth up to
mm removal of stumps of trees cut earlier and disposal of
unserviceable materials (C) By mechanical means in area of light
[136] Earthwork for embankment including breaking clods, dressing with 6451.12 Cum 161.22
all lead and lift (excluding watering and consolidation)(E) From
Borrow area within 3.0 Km. lead
[137] Rolling & watering of earthwork in layers with Power roller 6451.12 Cum 22.48
including filling in depressions which occurs during the process &
watering of earthwork as directed
[138] Box cutting the road surface to proper slope and camber for 584.00 Cum 104.20
making a base for road work including removing the excavated
stuff and depositing on the road side slope as directed upto
[139] Supplying and stacking of graded stone aggregate of following size 366.00 Cum 1158.20
(for W. B. M. ) including Spreading the stone aggregate for rolling
including filling the interstices to required camber and gradient
Machine crushed stone aggregate 45 mm to 63 mm size
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[140] Supplying and stacking of Soft murrum / Binding materials 92.00 Cum 676.55
including spreading road crust filling the gaps in metal and leveling
to camber and gradient as directed.
[141] Rolling and consolidating water bound macadam (except laterite 2434.00 Sqm 21.00
and Kankar) including watering not exceeding 150mm thickness
(Main layer including binding materials ) including filling in
depressions which occur during the process.(A) With power roller
exceeding 8 tonne and not exceeding 12 tonne.
[142] Providing and laying controlled C.C.M.250 road pavement & curing 334.00 Cum 5068.64
complete including the cost of form work but excluding the cost of
reinforcement for reinforced concrete work in RCC road including
Compaction and finishing of cement concrete road by trimix
process providing extra labour charges for the trimix vacum
dewatering service process on cement concrete road surface by
using vacum dewatering pump floater surface vibrator including
making grooves , filling grooves and rough finish to surface as per
in including levelling the complete etc. complete as per instruction
of Engineer In Charge.
[143] Supplying promoulded bituminous joint filler.(i) 12mm thick 5.00 Cum 553.79
[144] Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement 6.00 Each 19330.46
:2-coarse sand : 4-graded stone aggregate 20mm nominal size)
foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick
bats 40 + 50mm size) inside plastering 15mm thick with Cement
Mortar 1:3 (1-Cement : 3-coarse sand) finished with a floating coat
of neat cement and making channels in cement concrete 1:2:4 mix
(1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size)
finished smooth complete including curing and festing (i) Inside
size 900mm x 1200mm and 1.5M. deep including C.I. cover with
frame size 560mm diameter total weight of cover and frame to be
not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame
Kg.)(A) With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar
1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre for
150mm diameter sewer.
[145] Steel work welded in built up sections, framed work including 96.80 Qtl. 10077.08
cutting, hoisting, fixing in position and applying a priming coat of
red lead paint and two coats of matte finish oil painting etc
complete. (B) In trusses and trussed purlins upto 25 m. span and
15 m. overall height
[146] Providing corrugated PPGL Sheets roofing fixed with 801.00 484.00 Sqm 883.14
Galvanized iron 'U' or 'l' hooks bolts and nuts 8 m. diameter with
bitumen and G.I.Limpet washers filled with white lead complete
including ridges, gutters etc. excluding the cost of purlins, rafters
(1) 0.60 mm. Thick sheet
[147] Providing and fixing pre-cast Rubber Dye / steel Dye inter locking 768.00 Sqm 686.90
concrete Designer Paver block (Similar to VYARA) 60mm thick with
grade of concrete M300 pnumatic compressed / vibrated
mechanically and as per approved design Confirming to IS 15658 :
2006 including 35 mm Sand layer for levelling and filling the joint
with sand in proper line and level as per guidlines of IRC : SP 63-
2018 etc. Complete.
[148] Providing and fixing pre-cast concrete kerb stone of gray cement 673.00 Rmt 384.96
based concrete block 30cm length,30cm height and 15cm thick of
M200 grade concret as per approved design and including
excavation for fixing in proper line and level,filling the joint with
C:M 1:3 (1cement:3fine sand) etc complete.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[149] Providing Rain Water Harvesting 2 m. x 2 m x 4 m Pit for water 1.00 No 60612.70
logging with excavation in any strata up to 4 m depth, filling the pit
with brick bats in 0.6 m depth, 0.30 m depth with 10 mm To
mm Kapchi, 0.30 m depth with 6 to 10 mm grit and 2.00 m depth
with coarse sand in layers including making P.V.C. Pipes 10 kgf /
Sq.cm. 110 mm dia. line for water inlet etc. as directed, 300 mm
dia bore up to 50 Mtr. depth and 160 mm dia perforated PVC pipe
casing - 48 Mtr. length and making connections etc. complete as
directed for recharge well for rain water harvesting.
[150] Providing, laying and jointing in true line and level 160 diametre 140.00 Rmt 831.22
U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain
and other end socketed with rubber ring, & fittings conforming to
ISI 14735-1999 of approved make for drainage system pipe line,
pipe shall be jointed with each other with rubber lubricant, pipe
shall be fixed on wall using of PVC clamp of the size 160 mm
diametre x 210 mm length x 196 mm heigh at every 2000 mm
center to center or shall be concealed in walls as directed including
necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement
including cost of all materials.
[151] Providing and constructing a Filter Chamber of size 3.06 x 2.21 x 1.00 No 56283.44
1.20 mt. as including connecting of rain water pipes as per detail
drawing and as directed by Engineer-in-charge.
[152] Providing and plantation of Ornamental plants like areca palm, 50.00 No 681.75
bottle palm,adenium or equivalent etc. by digging of pit size 2x2x2
ft including DAP, Pestisides, plantation and saplings and making
proper Tree basin and putting proper support like bottle
palm,Areca Palm, Adenium or equivalent etc of 2ft to 6ft height
well growth or as directed by engineer in charge and maintaining
till well established etc. complete. (about 90 days)
[153] Providing and plantation of plants like Kadam, ,English Rose or 20.00 No 303.00
equivalent etc by digging of pit size 2x2x2 ft including DAP,
Pestisides, plantation and saplings and making proper Tree basin
and putting proper support of 2ft to 4ft height well growth or as
directed by engineer in charge and maintaining till well
established etc. complete. (about 90 days)
[154] Providing and plantation of Cycus by digging of pit size 2x2x2 ft 15.00 No 4040.00
including DAP, Pestisides, plantation and saplings and making
proper Tree basin and putting proper support like cycus plant of
3ft to 6ft height well growth or as directed by engineer in charge
and maintaining till well established etc. complete. (about 90 days)
[155] Providing and plantation of Decorative Plants with good quality 60.00 No 75.75
manure & Soil plant likes Canna,Mogra, Allamanda, Jasmine,Desi
Gulab,Parijaat,Ratrani etc or equivalent of well growth or as
directed by engineer in charge and maintaining till well established
etc. complete. (about 90 days)
[156] Providing tree plants having minimum 1.00 mt. height and healthy 40.00 No 252.50
growth of various kinds as like Platform gulmahore Kananj Ambla,
Ranitree, Saptaparni, Cherry, Cryjeliya, Spethodia, Paras Pipala,
Gromalo, Nem, Borsalli,Buch, Chompo, Asopalav and as suggested
etc. complete.as directed by engineer in charge and maintaining
till well established etc. complete. (about 90 days)
[157] Maintanance of Planted tree upto Two Year inclUDING Watering, 185.00 No 282.80
digging pits,trimmimg applying Fertilizer insecticides . pesticides
and Pesticides and replacing plants if necessary etc complete for
raising of Plants weeding or soil working.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[158] Lawn Grass:- Supplying & Filling the area upto the depth of 30 cm. 6563.00 Sqm 222.20
with good quality of field fertile soil, preparing soil for planting by
supplying and mixing Farm yard Manure at the rate of 5 Cum per
100 Sq. Mtr. Area , providing and planting suckers of pure dharo
(doob) grass roughly at 10 cm X 10 cm distance and maintaining till
well established etc. complete. (about 90 days)
[159] Providing and fixing single shutter FRP frame size 100x50 mm and 1.89 Sqm 3212.31
35mm thick FRP depress panel shutter having extra reinforcement
on sides & edges in Gel coat finish. The core of the shutter & frame
is to be filed up with injected fire retardant grade polyurethene
foam done in situ alongwith embedded wooden pieces for
stiffening & also taking hinges & fintures. The whole FRP frame &
shutter is to be water proof weather proof, termite proof &
resistance to mild acid/alkali. Rates are to be inclusive of S.S hinges
with necessary screws & alluminium fixtures & fastenings &
fastener sleeve.
[160] Providing and laying broken chine mosaic flooring for terrace using 9.00 Sqm 1046.35
12 mm to 20 mm broken pieces of glazed tiles to be laid over avg.
40 mm thick cement concrete flooring 1:2:4 (1- cement : 2-coarse
sand : 4-graded stone aggregate 20mm nominal size ) over cement
mortar 1:3 to plain or slope and to be tempered to bring mortar
creme out upto surface using white cement including rounding off
junctions and extending them upto 15 cm along the wall,clearing
with water and oxalic acid etc. as directed.
[161] Fire Fighting Fire Pump Room & Accessories Supplying, Installation, 1.00 No 263105.00
Testing and commissioning of Electric driven Main Fire Hydrant
pump suitable for automatic operation and consisting of following:
Horizontal type, centrifugal End Suction pump of cast iron body &
bronze impeller , mechanical seal to ensure a minimum pressure
of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of
137m3/Hour@ 70M. head with M.S.fabricated common base
plate, coupling, coupling guard, foundation bolts etc. as required
[162] Supplying, Installation, Testing and commissioning of Jockey Pump 1.00 No 106151.00
10.8M3/hour @70M Head.Horizontal Centrifugal End Suction. with
M.S.fabricated common base plate, coupling, coupling guard,
foundation bolts etc. as required
[163] Supplying, Installation, Testing and commissioning of cubical type 1.00 No 131906.00
floor mounted power cum Fire Pump control panel complete with
suitable switch gear, bus bars, relays, contractors, indicating
lamps, fuses, instruments manual isolator & auxillary switch
including connections complete as required.(Contractor should
submit GA Drawing for approval before deliver the Panel at Site)
[164] Providing, fixing, testing and commissioning below Caballing work 20.00 Rmt 292.90
for Fire Pumps (Only from Panel to Pumps) 3 C X 35 Sqmm
Alluminium Armoured
[165] Providing, fixing, testing and commissioning below Caballing work 20.00 Rmt 181.80
for Fire Pumps (Only from Panel to Pumps) 3 C X 16 Sqmm
Alluminium Armoured
[166] Providing, fixing, testing and commissioning below Caballing work 70.00 Rmt 113.12
for Fire Pumps (Only from Panel to Pumps) 2 C X 1.5 Sqmm Copper
[167] Providing, fixing, testing and commissioning below Caballing work 10.00 Rmt 353.50
for Fire Pumps (Only from Panel to Pumps) Perforated G.I.sheet
cable tray Cable Tray . 300X300X50mm .
[168] Providing, fixing, testing and commissioning below Caballing work 10.00 Rmt 252.50
for Fire Pumps (Only from Panel to Pumps) Perforated G.I.sheet
cable tray Cable Tray . 150X150X50mm .
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[169] Cutting hole by Mechanical Means of upto 200 mm dia in 10.00 Rmt 2020.00
slab/beam throughout the thickness
[170] Providing, fixing, testing & commissioning of Glicerin Filled dial 3.00 No 1358.45
type Pressure Gauge and range of 0-15 Kg/cm2
[171] Providing, fixing, testing & commissioning of Pressure Switches for 2.00 No 1010.00
automation of fire pumps. Pressure switches shall be double pole
single throw type suitable for 3 phase supply with diaphragm.
Aluminum Enclosure with IP 66 protection as required..
[172] Supplying, Installation, Testing and commissioning of C.I.Butterfly 5.00 No 5181.30
valve conforming to I.S:13095 class PN 16 rating with Fittings,
Flanges, Nutbolts, Washers, Gaskets etc.of size: 150mm dia.
[173] Supplying, Installation, Testing and commissioning of C.I.Butterfly 1.00 No 3817.80
valve conforming to I.S:13095 class PN 16 rating with Fittings,
Flanges, Nutbolts, Washers, Gaskets etc.of size: 100mm dia
[174] Supplying, Installation, Testing and commissioning of C.I.Butterfly 1.00 No 3181.50
valve conforming to I.S:13095 class PN 16 rating with Fittings,
Flanges, Nutbolts, Washers, Gaskets etc.of size: 80mm dia.
[175] Supplying, Installation, Testing and commissioning of C.I.Butterfly 2.00 No 2716.90
valve conforming to I.S:13095 class PN 16 rating with Fittings,
Flanges, Nutbolts, Washers, Gaskets etc.of size: 50mm dia.
[176] Providing, fixing, testing and commissioning of C.I. Dual plate type 3.00 No 7383.10
Non-Return Valve class PN 16 rating with fittings, flanges, nutbolts,
washers, gaskets etc.of sizes: 150mm dia
[177] Providing, fixing, testing and commissioning of C.I. Dual plate type 2.00 No 4332.90
Non-Return Valve class PN 16 rating with fittings, flanges, nutbolts,
washers, gaskets etc.of sizes: 80mm dia
[178] Providing, fixing, testing and commissioning of C.I. Dual plate type 2.00 No 2979.50
Non-Return Valve class PN 16 rating with fittings, flanges, nutbolts,
washers, gaskets etc.of sizes: 50mm dia
[179] Supply, Installation, Testing and Commissioning of S.S. Ball Valves 3.00 No 1272.60
with all fittings required. 25mm dia.
[180] Supply, Installation, Testing and Commissioning of S.S. Ball Valves 5.00 No 1191.80
with all fittings required. 15mm dia.
[181] Providing, fixing, testing and commissioning of Above Ground MS. 126.00 Rmt 2121.00
ERW Black C Class Heavyduty pipes as per IS: 1239 (upto 150 mm
dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting,
screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one
coat of primer and 2 or more coats of synthetic enamel paint of
approved make / shade complete as per specification. 150mm dia
[182] Providing, fixing, testing and commissioning of Above Ground MS. 18.00 Rmt 1424.10
ERW Black C Class Heavyduty pipes as per IS: 1239 (upto 150 mm
dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting,
screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one
coat of primer and 2 or more coats of synthetic enamel paint of
approved make / shade complete as per specification. 100mm dia
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[183] Providing, fixing, testing and commissioning of Above Ground MS. 12.00 Rmt 1010.00
ERW Black C Class Heavyduty pipes as per IS: 1239 (upto 150 mm
dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting,
screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one
coat of primer and 2 or more coats of synthetic enamel paint of
approved make / shade complete as per specification. 80mm dia
[184] Providing, fixing, testing and commissioning of Above Ground MS. 6.00 Rmt 656.50
ERW Black C Class Heavyduty pipes as per IS: 1239 (upto 150 mm
dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting,
screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one
coat of primer and 2 or more coats of synthetic enamel paint of
approved make / shade complete as per specification. 50mm dia
[185] Providing, fixing, testing and commissioning of Above Ground MS. 6.00 Rmt 303.00
ERW Black C Class Heavyduty pipes as per IS: 1239 (upto 150 mm
dia.) and IS: 3589 (upto 200 mm dia. And above) including cutting,
screwing, welding etc. and providing all fittings like flanges, bends,
tees, elbows, reducers, clamps, hangers etc. with painting of one
coat of primer and 2 or more coats of synthetic enamel paint of
approved make / shade complete as per specification. 25mm dia.
[186] Supplying, installing and commissioning of Foot Valve with,suitable 1.00 No 15705.50
flanges, nuts, bolts, gaskets etc. complete. 150mm dia
[187] Supplying, installing and commissioning of Foot Valve with,suitable 1.00 No 10524.20
flanges, nuts, bolts, gaskets etc. complete. 80mm dia
[188] Fire Fighting Equipement Providing, fixing, testing and 3.00 No 5262.10
commissioning of SS Single Headed Oblique Pattern Hydrant
Landing Valves as per IS: 5290 with 80 mm dia flanged inlet &
mm dia female outlet complete with cap and chain etc.
[189] Providing, fixing, testing and commissioning of SS Branch Pipe with 3.00 No 1696.80
nozzle of 25 mm nominal bore outlet suitable to fit with standard
instanteneous type 63 mm dia coupling. As per IS:903
[190] Providing, fixing, testing and commissioning of 63 mm dia 15m 6.00 No 3989.50
long RRL Hose Pipe with 63 mm dia.Type A Male and female
Stainless Steel couplings duly binded with GI wire, rivets etc.
conforming to IS 636 as required.
[191] Providing, fixing, testing and commissioning of weather proof 3.00 No 3646.10
standard fire Hose Cabinet wall mounting type 18 Guage. (750 x
600 x 250) having Double Opening with M.S. fabricated stand,
necessary locking arrangement by allan key.
[192] Providing, fixing, testing and commissioning of Wall mounting Fix 2.00 No 5948.90
type First aid Fire Hose Reel with drum, hanging bracket, 36 M x
mm dia high pressure hose reel tubing as per IS:884 with shut
nozzle and ball valve and all required accessories.
[193] Providing, fixing, testing and commissioning of CI Four way Fire 1.00 No 12311.90
Brigade Inlet as per IS: 904 having 63 mm dia inlet with 150 mm
dia Butterfly valve blank cap and chain with necessary fittings,
flanges, nutbolts etc.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[194] Providing, fixing, testing and commissioning of Two Way Fire 1.00 No 11463.50
Brigade Inlet for Draw Out Connection with 100mm dia Foot Valve.
blank cap and chain with necessary fittings, flanges, nutbolts etc.
(Make: Shah Bhogilal/Safex/Winco)
[195] Providing, fixing, testing and commissioning of 25 mm dia Air 2.00 No 1363.50
Release Valve and Ball Valve assembly on top of each riser for Air
release system.
[196] Supplying, Installation, Testing and commissioning of ABC type 6 20.00 No 1696.80
Kg Fire Extinguisher Mono Ammonium Phosphate Powder
Stored Pressure Type, Pressure Gauge, Controllable discharge
mechanism Class A, Rating 3A & Class B rating 21B as per IS
ISI MARK (ABC Dry Chemical Powder - MAP 50%).
[197] Providing & fixing of CO2 type Fire Extinguisher of capacity 4.5 kg 20.00 No 3989.50
filled with Co2 Gas as per IS 15222 with controll discharge
mechanis, fitted with Hose & Horn applicable on Class B fire rating
21B confirms to IS 15683 bearing ISI mark. Co2 cylinder as per IS
[198] On - Off Pump Trigger System. Providing, fixing, testing and 3.00 No 424.20
commissioning of On -Off Switch.
[199] Providing, fixing, testing and commissioning of 3 Core X 1.5 Sqmm 50.00 Rmt 85.85
flexible Cable with PVC Condiut.
[200] Providing, fixing, testing and commissioning of below Auto Glow 35.00 No 171.70
Signages. Emergency Exit 4” X 12”
[201] Providing, fixing, testing and commissioning of below Auto Glow 10.00 No 339.36
Signages. Fire Fighting Equipements .8” X 12”
[202] Providing, fixing, testing and commissioning of below Auto Glow 3.00 No 323.20
Signages. In Case of Fire do not use Lift ,Use Staircase 8"x 8"
[203] Providing and fixing of convention Below Ceiling smoke detector 85.00 No 3232.00
complete with mounting base as required.
[204] Providing, Installing & Commissioning the Manual call point zone 6.00 No 3817.80
convention type of best standard quality brand including labour,
material, loading, unloading, transportation ,taxes , tools
accessories etc complete as per direction of Engineer In Charge.
[205] Providing , Installing & Commissioning the Hooter 24 v Zone 6.00 No 3817.80
Convention Type of best standard quality brand including labour,
material, loading, unloading, transportation ,taxes , tools
accessories etc complete as per direction of Engineer In Charge.
[206] SITC Of Addressable Fire Alarm Panel 1.00 No 106100.50
[207] Providing and fixing of 2x1.5 sqmm fire alarm armoured cable, 800.00 Rmt 103.02
600/1000V rated with annealed copper conductor having XLPE
insulation, steel wire armouring &FRLS outer sheath complete as
[208] APPROVAL FIRE SYSTEM FROM LOCAL FIRE AUTHORITY Getting of 1.00 Job 303000.00
Fire Fighting System Approval from local fire authority with all
other charges and documentations for getting No Objection
[209] Drilling of Tubewell by direct rotary rig in alluvial starta 120.00 Rmt 756.49
Drilling of Pilot bore hole in Alluvial strata by direct Rotary rig.of
size 250 mm diameter.
Alluvial area complete upto 300 m (kheda District)
[210] Reaming of 250/300 mm dia. pilot bore hole including assembling, 120.00 Rmt 465.61
lowering housing casing ,strainer pipes, gravel packing, clay
packing etc. 550 mm dia
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[211] Providing and supplying in standard length ISI mark rigid 140.00 Rmt 920.11
unplasticised PVC pipes suitable for potable water with ring fit
joint including cost of rings, as per IS specification no. 4985/1988
including all local and central taxes, transportation, freight
charges, octroi, inspection charges, loading, unloading,
conveyance to the departmental stores and including cost of
jointing meterial etc. complete.(3.1/B) Test Pressure 6 Kg/cm2 (9)
[212] Lowering and removing of 100 mm dia dropline and 32 mm dia 120.00 Rmt 149.48
airline for development of each water bearing Zones come across
up to full depth of Deep tubewell of size 200 mm/250 mm/300 mm
dia for the tubewell having depth upto depth 186 Meter depth
through suitable air compressor. The job is for complete period of
development of tubewell.( where water is very deep and 2/3rd
submersion is not achived.) All the required accessories,
machineries etc for above job will have to be provoded by
[213] Providing and lowering of 200 mm dia PVC Test Pressure 6 Kg/cm2 30.00 Rmt 404.00
slotted pipe etc complete as per instruction of Engineer In Charge.
[214] Clamp made from M.S. plate with 3 holes on either side with nuts 2.00 Pair 1643.98
& bolts of Std. Make and suitable size.
(g)750 mm X 75 mm X 16 mm flat to 200 mm dia.Pipe.
[215] Bore plug of 100 mm height made from MS plate with 3 holes at 1.00 No 782.56
equal distance on circumference for nut-bolts type, locking
arrangement with nutsbolts & lock nuts of standard make etc.
(B) From 5 thick M.S. Plate (For Top also)
(ii) Suitable for 200 mm dia pipe.
[216] Bail plug of length 0.45 meter made from MS medium class pipe as 1.00 No 851.03
per IS suitable for
(B) 200 mm dia pipe.
[217] Steel bent plate suitable to ERW pipe as detailed below ERW Pipe 1.00 No 67.25
Size in mm.(b) 200 mm dia. 150 X 150 X 6 mm
[218] Supply of best quality well sorted Sevaliya gravel of size ranging 15.00 Cum 2049.29
from 4 mm to 6mm.
[219] Electrologger charges (With carting) (B) For other dept. 1.00 Job 18180.00
[220] Air Compressor 1.00 LS 27603.30
Charges of air compressor for test of tube well by air compressor
of 900 CFM / 200 PSI capacity Upto clear water discharge
[221] Geophysical & geohydrological ground water investigation for 1.00 No 14428.86
finalisation of one pin point including vehicle charges.
[222] Manufacture, supply and delivery of 65 mm size CI pipe adaptor 1.00 Set 745.69
and pump adaptor for UPVC column pipes.
[223] Manufacture, supply and delivery of following ISI marked HDPE 120.00 Rmt 84.84
pipes (IS:4984/1985 with latest amendment) having material
Grade PE-80 in approximate 100 meter coil length or as per
GWSSB requirement with SS- 316 nipple at both ends having 11 TPI
threads as per specifications, press fitted and bolted having
nominal diameter as under as per detailed technical specifications.
iii)DN 50 PN-10
[224] Supply of nut bolt rubber packing and required materials and 1.00 LS 3030.00
dilevery connection for new bore.
[225] Excavation for foundation for depth from 3.0 m to 5.0 m including 31.00 Cum 308.38
sorting out and stacking of useful materials and disposing off the
excavated stuff upto 50 Meter lead.(D) Soft rock not requiring
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[226] Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 353.00 Pt. 491.87
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC
/ Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder with
adaptor/ceiling rose / H.D.Connector as directed.(j) in existing pipe
erected concealed in wall/ceiling complete.Cat.III
[227] Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm 163.00 Pt. 667.61
(Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected with 6A Modular type switch and hum free EME
step type electronic fan regulator mounted and accessories with
earth continuity of following type erected on PVC /
Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.(j) in existing pipe erected concealed in
wall/ceiling complete.Cat.III
[228] Point wiring for Individual Plug with & earth wire of 1.5 sq.mm 5.00 Pt. 511.06
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories.[I] For 6A Plug and 6 a
switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb
db board.(j) in existing pipe erected concealed in wall/ceiling
complete.Cat.III
[229] Point wiring for Individual Plug with & earth wire of 1.5 sq.mm 22.00 Pt. 681.75
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug
erected on PVC / Metallic/Wooden box covered with appropriate
front plate modules erected on / in wall / ceiling as per pipe
erected with following type of accessories.(j) in existing pipe
erected concealed in wall/ceiling complete.[II] For 16A Plug and
16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db
[230] Point wiring for on board Looped Plug with 6A Modular type 114.00 Pt. 309.06
switch & 5 pin socket erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured / metallic/white
front plate modules erected on / in wall / ceiling with following
type accessories.Cat.III
[231] Providing following type of Modular Type Accessories mounted 23.00 Ea. 160.59
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge.(3) Two Pin/RJ-11 Telephone Socket.[A] For
One Gang. Cat.III
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[232] Providing following type of Modular Type Accessories mounted 115.00 Ea. 25.25
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge.(7) Blank Plate Single cat-III
[233] Providing following type of Modular Type Accessories mounted 86.00 Ea. 160.59
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge.(8) Computer RJ-45 socket.Cat.III
[234] Providing following type of Modular Type Accessories mounted 9.00 Ea. 199.98
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge.(10) 6/16Amp. Universal socket cat-III
[235] Providing following type of Modular Type Accessories mounted 5.00 Ea. 410.06
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge.(14) 6A/ 10A/ 16A/ 20A/ 25A/ 32A Double
Pole Modular MCB Switch.Cat.III
[236] Providing and erecting ISI mark Medium class RIGID PVC PIPES of 7764.00 Mtr. 24.24
following size complete to be erected on/in wall or ceiling erected
with necessary PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in approved manner
as directed (a)20 mm
[237] Providing and erecting ISI mark Medium class RIGID PVC PIPES of 800.00 Mtr. 33.33
following size complete to be erected on/in wall or ceiling erected
with necessary PVC fittings & Junction boxes fixed with adhesive
solution & Clamps with following dia of pipes, in approved manner
as directed(b) 25 mm
[238] Providing & erecting PVC Corrugated Flexible Conduit with 100.00 Mtr. 21.21
required nos. of coupling, PVC bushes, Check-nuts etc. complete of
following sizes.(2) 25 mm.
[239] Supplying under floor pregalvanised corrosion proof rectangular 216.00 Mtr. 458.54
sheet steel cable trunking of 1.6 mm thick having with stand point
load up to 1.33 Ton & free from seepage of concrete of screed
water with all accessories,Junction Box,Joints as required and
demanded by engineer-incharge and laying/erecting as per OEM
guidelines and as per instruction of engineer incharge having
following size of dimensions and No of compartments (W x D x T)
Cat-III.[3] 100mm x 25mm x 1.6 mm with one compartment.
[240] [6] 300mm x 25mm x 1.6 mm with Three Compartments. 160.00 Mtr. 1224.12
[241] Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 3195.00 Mtr. 78.78
ISI marked stranded Copper conductor wire in following type of
pipe to be erected concealed in /flushed on wall/ceiling, with
sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size.(E) in existing
pipe.(b) 2 wire 2.5 sq. mm
[242] providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 80.00 Mtr. 109.08
ISI marked stranded Copper conductor wire in following type of
pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size.(E) in existing pipe.(a) 2 wire 4 sq.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[243] providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 80.00 Mtr. 184.83
ISI marked stranded Copper conductor wire in following type of
pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size.(A) with medium class Rigid PVC
pipe and accessories.(b) 2 wire 6 sq. mm.
[244] providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 945.00 Mtr. 226.24
ISI marked stranded Copper conductor wire in following type of
pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size.(A) with medium class Rigid PVC
pipe and accessories.(g) 4 wire 4 sq. mm.
[245] providing and erecting Mains with 1.1 KV grade FRLS PVC insulated 540.00 Mtr. 326.23
ISI marked stranded Copper conductor wire in following type of
pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for
earth continuity of following size.(A) with medium class Rigid PVC
pipe and accessories.(h) 4 wire 6 sq. mm
[246] providing and erecting Mains with ISI marked, 1.5KV grade 64.00 Mtr. 70.70
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.(e) One wire 6.00 sq.
[247] providing and erecting Mains with ISI marked, 1.5KV grade 864.00 Mtr. 115.14
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.(f) One wire
[248] providing and erecting Mains with ISI marked, 1.5KV grade 104.00 Mtr. 376.73
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.(i) One wire
[249] providing and erecting Mains with ISI marked, 1.5KV grade 16.00 Mtr. 588.83
electrolyte multi stranded, annealed copper conductor with heat
resistant PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control panel, relays,
power switchgears, motor starters & control wiring) with required
size of copper lugs, nuts and bolts if required.(j) One wire
[250] Supplying and erecting Flexible PVC insulated multistrand 50.00 Mtr. 28.28
multicore 1.1 kv grade ISI marked copper wires of following size to
be erected as directed.(c) 1.00 Sq.mm 2 core round/ flat PVC
[251] Supplying and erecting Flexible PVC insulated multistrand 100.00 Mtr. 58.58
multicore 1.1 kv grade ISI marked copper wires of following size to
be erected as directed. e) 1.50 Sq.mm 3 core round PVC sheathed
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[252] Supplying & erecting approved make Telephone Cable electrolytic 585.00 Mtr. 20.20
copper conductor PE insulation twisted in two pairs, & wrapped
with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring & confirming to C-DOT erected
in existing pipe. of following size of conductors & nos.of pairs.
With necessary connections.[A] Conductor Size 0.5 mm .(a)
Unarmoured.(2) Two Pairs.
[253] Supplying & erecting approved make Telephone Cable electrolytic 20.00 Mtr. 199.98
copper conductor PE insulation twisted in two pairs, & wrapped
with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring & confirming to C-DOT erected
in existing pipe. of following size of conductors & nos.of pairs.
With necessary connections.[A] Conductor Size 0.5 mm .(b)
Armoured [Jelly Filled].(2) Twenty Pairs.
[254] Supplying & erecting approved make Telephone Cable electrolytic 200.00 Mtr. 467.63
copper conductor PE insulation twisted in two pairs, & wrapped
with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer
Jacket suitable for telephone wiring & confirming to C-DOT erected
in existing pipe. of following size of conductors & nos.of pairs.
With necessary connections.[A] Conductor Size 0.5 mm .(b)
Armoured [Jelly Filled].(3) Fifty Pairs.
[255] Supplying & erecting approved make LAN cable of following size in 3165.00 Mtr. 76.76
existing pipe as per direction.[D] CAT - 6 e.
[256] Providing & erecting main Distribution (MDF) indoor type, back 2.00 Ea. 1368.55
mounted frame as per DoT standard approved with krone
strips.(b) Suitable for 20 pair.
[257] (c) Suitable for 50 pair 3.00 Ea. 1747.30
[258] Providing & Erecting 3mm thick acrylic Sheet with grooving as 2000.00 Sq. Inch. 3.03
[259] Providing & erecting Switch board for Computer or electric 86.00 Ea. 1133.22
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed.1
no. 6A/16A universal plug-switch combined.
3 nos. 6A Switch.3 nos. 6A 5 pin Plug.For Modular Type
Accessories.Cat.III
[260] Decorative call bell Ting-tong box type 250 volts complete erected 21.00 Ea. 71.71
[261] Supplying & erecting Electronic Type Cordless Call Bell erected on 5.00 Ea. 250.48
PVC/Metal board having portable bell push working on D.C. & bell
on 230V A.C. supply with cells / battery
[262] Supply of Fibreglass Step (A Type) Ladder - 10 FT having following 2.00 Ea. 22342.21
specifications :It should have nonconductive Structural moulded
top, with Slots to keep tools close at hand, inside Spreader Braces,
Aluminium Feet with thick rubber tread, nonconductive Full
channel Fibreglass, two pairs of gusset support at the bottom step
and All gussets are heavy duty steel.Capacity : 300 lbs. Step Size :
3”.Width : 29” Approx. Spread : 66”Approx. Wt. : 19 Kg Approx.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[263] Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 10.00 Ea. 238.36
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name
160V to 270V, Power Factor more than 0.95, THD < 15%,CCT
K to 6500K,Luminaire efficacy> 85 lumens/watt,LED driver
efficiency > 85 %,(fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)(A) Tube Light
with integral driver.(ii) 12-14 Watts, Surge-2 KV, IP-20,
conventional 4 feet.Cat.III
[264] Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 202.00 Ea. 373.70
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name
160V to 270V, Power Factor more than 0.95, THD < 15%,CCT
K to 6500K,Luminaire efficacy> 85 lumens/watt,LED driver
efficiency > 85 %,(fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)(A) Tube Light
with integral driver.(iv) 22-24 Watts, Surge - 2KV,IP-20,
conventional 4 feet.Cat.III
[265] Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 18.00 Ea. 427.23
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high
U.V. & corrosion resistance with diffuser housed in aluminium
casted body with company mark/name 160V to 270V,Power Factor
more than 0.95, THD < 15 %,CCT 3000 K to 6500K,Luminaire
efficacy> 85 lumens/watt ,LED driver efficiency > 85 %,( fitting
required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the
ranges shown.)(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring loaded mounting clips
complete.IP20.(ii) 11-15 watts, Surge-2 KV.Cat.III
[266] Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 71.00 Ea. 758.51
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high
U.V. & corrosion resistance with diffuser housed in aluminium
casted body with company mark/name 160V to 270V,Power Factor
more than 0.95, THD < 15 %,CCT 3000 K to 6500K,Luminaire
efficacy> 85 lumens/watt ,LED driver efficiency > 85 %,( fitting
required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the
ranges shown.)(A) Square/ Circular shaped Surface/Recessed
Mount Downlight with provision for spring loaded mounting clips
complete.IP20.(iv) 22-24 watts, Surge-2 KV.Cat.III
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[267] Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 9.00 Ea. 1794.77
Watt to 0.5 Watt assembled on single MCPCB, with housing used
as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high
U.V. & corrosion resistance with diffuser housed in aluminium
casted body with company mark/name 160V to 270V,Power Factor
more than 0.95, THD < 15 %,CCT 3000 K to 6500K,Luminaire
efficacy> 85 lumens/watt ,LED driver efficiency > 85 %,( fitting
required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the
ranges shown.)(B) LED Panel Light with provision for Plane front
frame with translucent cover fixed to housing complete.IP20.(vi)
36 watts, 24" x 24", Surge- 2KV.Cat.III
[268] Supplying and erecting LED street light / Flood light fittings with 18.00 Ea. 4248.06
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt
. LED driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)(A) Street Light
(IP-65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection.(i) 48 watts.Cat.III
[269] (B) Flood Light (IP-65), Surge protection -4KV integral and ,Light 10.00 Ea. 6177.16
must have 440VAC line supply with over-voltage protection.(iv)
[270] Providing and erecting Approved make Four pole moulded case 21.00 Ea. 6790.23
circuit breaker having breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply 50 Hz.
with all internal connections, spreader tinned copper & complete
erected in existing 16 G.M.S. housing.ICS=100% of ICU only. Cat III
[271] Providing and erecting Approved make Four pole moulded case 1.00 Ea. 8861.74
circuit breaker having breaking capacity ICU of 35 KA. at 415 V.
having normal current rating 125A. with Fixed thermal & magnetic
release suitable to work on A.C.supply 50 c/s. with all internal
connections, spreader tinned copper & complete erected with
enclouser 16 G.M.S. housing.ICS=100% of ICU only.Cat III
[272] Providing and erecting Approved make Four pole moulded case 11.00 Ea. 17843.67
circuit breaker having breaking capacity ICU of 35 KA. at 415 V.
having Normal current rating 200A.with variable Thermal &
magnetic release suitable to work on A.C.supply 50 Hz. with all
internal connections, spreader tinned copper & complete erected
in existing 16 G.M.S.housing.ICS=100% of ICU only.Cat III
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[273] Providing and erecting Approved make Four pole moulded case 1.00 Ea. 27751.77
circuit breaker having breaking capacity ICU of 50 KA and above at
415 V having Normal current rating 400A. with variable Thermal
& magnetic release suitable to work on A.C.supply 50 Hz. With all
internal connections, spreader tinned copper & complete erected
in existing 16 G.M.S. housing.ICS=100% of ICU only.Cat III
[274] providing and erecting Approved make Earth fault Relay suitable 9.00 Ea. 5156.05
to mount with inter connection suitable to following size of
moulded case circuit breaker having CT ratio & MCCB rating as
following along with shunt trip 220V AC. with all internal
connections & complete erected in existing M.S.housing.(1) 15 A -
100 A , CT Ratio 1/100.
[275] providing and erecting Approved make Earth fault Relay suitable 5.00 Ea. 5482.28
to mount with inter connection suitable to following size of
moulded case circuit breaker having CT ratio & MCCB rating as
following along with shunt trip 220V AC. with all internal
connections & complete erected in existing M.S.housing.(2) 125 A -
200 A , CT Ratio 1/200.
[276] providing and erecting Approved make Earth fault Relay suitable 1.00 Ea. 5956.98
to mount with inter connection suitable to following size of
moulded case circuit breaker having CT ratio & MCCB rating as
following along with shunt trip 220V AC. with all internal
connections & complete erected in existing M.S.housing.(3) 250 A -
400 A , CT Ratio 1/400.
[277] Supplying & erecting approved make Four Pole 415V change over 1.00 Ea. 22255.35
switch interior for panel mounting with operating mechanism
A.C.23 duty confirming to IS for (F)400A.Cat.III
[278] Supplying and erecting triple pole & neutral 440V / 500V panel 18.00 Rn.Mtr. 3202.71
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with necessary
connections.(B) Suitable for 200 Amp. capacity.
[279] Supplying and erecting triple pole & neutral 440V / 500V panel 1.00 Rn.Mtr. 7319.47
mounting Copper Busbars with four equal Nos. of electrolyte bus
having current density not more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly wrapped with colour insulating
tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable
socket to each bar, erected in existing cubical panel with necessary
connections.(D) Suitable for 400 Amp.capacity.
[280] providing and erecting Miniature circuit breaker single pole 0.5A to 28.00 Ea. 297.95
2A system and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.Cat.III
[281] Providing and Erecting Miniature circuit breaker single pole 6A to 220.00 Ea. 123.22
25A suitable to operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to IS
8828/1996 with ISI Mark cat-III
[282] Providing & erecting 240 V MCB double pole switch for motor & 16.00 Ea. 362.59
inductive load (C Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity.(B)
[283] Providing & erecting 415 V MCB Four Pole for Motor & Inductive 63.00 Ea. 655.49
Load (C Curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity.(A) 32 Amp.Cat.III
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[284] Providing & erecting 415 V MCB Four Pole for Motor & Inductive 42.00 Ea. 811.03
Load (C Curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity.(C) 63 Amp.Cat.III
[285] Providing & erecting 415 V MCB Four Pole for Motor & Inductive 83.00 Ea. 736.29
Load (C Curve) having 10KA breaking capacity & confirms to IS
:8828 in existing box having following capacity.(B) 40 Amp.Cat.III
[286] Providing and erecting Two way Centre off Four pole MCB Change 1.00 Ea. 1478.64
Over Switch (IS 13947-3 / IEC 60947-3) in existing box.(b) for
[287] Sheets steel powder coated enclosure suitable for incorporating 4.00 Ea. 176.75
One/Two nos. MCB.
[288] Providing and erecting Sheet Steel powder coated MCB 4.00 Ea. 1791.34
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable
for.(A) single phase incoming and horizontal single phase
outgoing(b) sheet steel double door (IP-43)(iv) 12 way.(Concealed)
[289] Providing and erecting Sheet Steel powder coated MCB 63.00 Ea. 355.52
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable
for.(A) single phase incoming and horizontal single phase
outgoing.(a) single door (IP-30).(i)4 way. (Open)
[290] Providing and erecting Sheet Steel powder coated MCB 15.00 Ea. 2806.99
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The
DBs should be used of same company of MCB to be used) suitable
for.(B) three phase incoming and single phase horizontal type
outgoing Per phase isolation type (PPI).(b) sheet steel double
door.(i) 4 way.(Concealed)
[291] providing and erecting Approved make RCCBs conforming to IS: 45.00 Ea. 2458.34
12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component.
for following Max. rating erected as directed.(ii) 40 Amps.
[292] providing and erecting Approved make RCCBs conforming to IS: 8.00 Ea. 2166.45
12640 and having sensitivity of 30 mA and Short Circuit withstand
capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all
advance feature & do not incorporate any electronic component.
for following Max. rating erected as directed.(i) 25 Amps.
[293] Providing and erecting required size Copper strip for earthing of 38.00 Kg. 794.87
H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[294] Supplying & erecting earth pit of minimum bore dia.150mm size 19.00 Ea. 4591.46
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make OEM has to
submit test certificate including value of earth resistance of
installation duly stamped and signed by agency and officer
Incharge has to ensure the value of earthing resistane mentioned
in test Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter testing as
per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency. (a) For
Electrical Installation up to 440V in normal soil,Length of pipe -
Mtr,Back filling compound - 1 Nos Bag of 15 Kg..
[295] Providing & erecting weather proof, dust & vermin proof, floor 19.90 Sq.Mtr. 14902.55
mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet for
outer body & doors, 16 SWG thick CRC M.S.sheet for internal
partitions with necessary accesories , supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting with
internal partitions & cable alley as per requirements & instruction
of engineer-in-charge with erection of supplied switch gears,
BUSBARS, suitable size of inter connecting PVC copper wire /
copper-aluminium strips, rubber grommets, rib, bakelite control
fuses/MCB for measuring instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates, sufficient nos. of hinged
doors, handles with locking arrangement and rubber gasket,heavy
duty end terminal connection,danger notice board,necessary
ventilation,earthing strip complete. The Panel shall be painted
with epoxy powder coating.(The rates excludes the cost of
switchgears, bus bars, inter connecting mains & Copper Aluminium
strips, meters, Fuses etc. The dimension shall be measured
excluding base beams) The panel shall be supplied with following
approved manufacturers with following size.(B) The standard
companies switch gear shall be used and only manufacturers at
CPRI approved factory .(i) with 350mm depth .
[296] Providing , erecting , fabricating the M.S. structure as per 375.00 Kg. 77.77
requirement on site incorporating proper size of M.S.
angles,square,round, flats, bars, channels, sections complete with
cutting, welding, grinding & finishing duly painted with one coat of
red oxide with erection on site as per direction of engineer in
charge with necessary grouting, cementing, plastering & finishing
[297] Supplying & erecting FRLS-XLPE(IS:7098)(I)-88 ISI unarmoured 20.00 Mtr. 362.59
copper cable 1.1 KV grade to be erected as directed of following
size. (D) 8 core 2.5 sq.mm.
[298] Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable 1000.00 Mtr. 648.42
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size
of cables (F) 3 1/2 core 120 Sq. mm ( 70 Sq.1/2 mm core).
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[299] Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable 100.00 Mtr. 1401.88
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size
of cables.(I) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core).
[300] Providing and erecting FRLS-XLPE(IS:7098)(I)-88 ISI armoured cable 610.00 Mtr. 454.50
multistrand Aluminium conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe of following size
of cables.(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core).
[301] Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI armoured 800.00 Mtr. 151.50
cable multistrand / Solid Aluminium conductor for 1.1 KV. to be
laid on wall with necessary clamps or in existing trench / pipe of
following size of cables (b) 4 core 6 Sq. mm
[302] Making trench in soft soil of suitable width of 90 cm deep for 910.00 Mtr. 55.55
laying cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
[303] Supplying following size of Light duty “A” Class G.I . Pipe & 25.00 Mtr. 300.98
erecting as directed by Engineer-in-charge. (B) 50 mm dia
[305] Providing & laying approved make Double walled corrugated 36.00 Mtr. 62.62
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cable.(A)50 mm outer dia.
[306] Providing & laying approved make ISI marked HDPE 6Kg / cm2 370.00 Mtr. 163.62
(Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing
on or floor as directed for laying of cable. The pipes as following
size of dia & weight per 6 mtr.(B) 50 mm inner Dia.
[307] Providing & laying approved make ISI marked HDPE 6Kg / cm2 900.00 Mtr. 491.87
(Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing
on or floor as directed for laying of cable. The pipes as following
size of dia & weight per 6 mtr.(E) 90 mm inner Dia.
[308] Providing & laying approved make ISI marked HDPE 6Kg / cm2 50.00 Mtr. 732.25
(Class-3) as per IS:4984:1995 PE-80 to be erected at road crossing
on or floor as directed for laying of cable. The pipes as following
size of dia & weight per 6 mtr.(F) 110 mm inner Dia.
[309] Providing and, fixing heavy duty flange type brass cable gland with 22.00 Ea. 38.38
rubber ring for PVC insulated armoured cable complete with out
going tails, insulating tape etc for following size of cables.(B) 2 to
[310] Providing and, fixing heavy duty flange type brass double 30.00 Ea. 103.02
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables.(C) 3 & 1/2 core 70 Sq. mm.
[311] Providing and, fixing heavy duty flange type brass double 20.00 Ea. 140.39
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables.((E) 3 & 1/2 core 120 Sq. mm
[312] Providing and, fixing heavy duty flange type brass double 7.00 Ea. 247.45
compression type cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc
for following size of cables.((H) 3 & 1/2 core 240 Sq. mm
[313] Solderless crimping type Aluminium lugs conforming to IS suitable 224.00 Ea. 6.06
for cable of following size evenly crimped with high pressure tool
& connected to switchgear terminals with brass/cadmium plated
nut bolts in an approved manner. (A) 1.5/ 2.5/4/6 Sq.mm
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[318] Providing & erecting Approved make Power Saving 50 Watt Ceiling 163.00 Ea. 1948.29
Fan with double ball bearing ISI mark with Condenser 230 volt A.C.
50 Hz 1200 mm sweep complete having 3blades with aluminium
blades with , canopy & 30 cm. down rod erected with earthing.
(Make shall be approved by Engineer in Charge))
[319] Supplying and erecting 19 / 20 mm. nominal bore Medium Class 163.00 Mtr. 108.07
M.S. Pipe down rod erected duly painted for fan complete with
proper insulation without leakage and earthing.
[320] Supplying & erecting fan hook box of 10 mm M.S. round bar 163.00 Ea. 108.07
bounded to the RCC bars up to 50mm length each side and pierced
through a 16 Gauge M.S. box / Heavy Duty PVC box complete
erected concealed in Ceiling with necessary finishing.
[321] Providing 2.5mm.thick laminated acrylic sheet to cover the fan 163.00 Ea. 18.18
hook or Fan box.
[322] Supplying & erecting approved make low noise decorative exhaust 22.00 Ea. 1703.87
fan having square frame ABS body with inbuilt lowers & square
frame.250mm with 1350 RPM Cat.II
[323] Supplying and erecting approved make oscillating type bracket fan 4.00 Ea. 2534.09
A.C. 23OV. 50cy/s 400/450 mm sweep wall mounted with height
adjustment and rotary tilting device complete with guard, flexible
Core plug top complete erected with lead wires as directed.Cat.II
[324] Supplying and erecting approved make Octagonal pole made from 18.00 Ea. 7561.87
HR sheet steel. The pole should be made as per IS. and shall be
coated with hot dip galvanizing as per IS 2629/2633/4759, suitable
suspend local wind speed with integral Junction box consist of
terminal plate of min 6mm Hylam sheet, standard profile
35mmX7.5mm Din-Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With Suitable
foundation (Included) as per details given by manufacturer
considering site requirement.(C) 5 Mtr. Long 70 mm Top X
mm bottom dia, 3 mm thickness with 200mmX200mmX12mm
base plate, 4-M16 Bolts and 600mm long with necessary G.I. J
Bolts .Approx Pole weight 46 kg.
[325] Supplying & erecting approved make SMC press moulded 10.00 Ea. 898.90
composite FRP. loop-in, loop-out approx. 2mm thick box complete
with Bakelite connector strip 5way(3P+N+E),DIN rail for mounting
mob & hinged doors as per requirement having locking
arrangements with mounting clamp with nuts, bolts & washers
suitable for erection on pole with cable clamps& earth bolt of
following size of box.(A) 300mm x 200mm x 100mm [deep].
[326] Providing and erecting street light pole bracket comprising main B 18.00 Ea. 561.56
Class MS pipe of 4.2 cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of approx. 45cms.length and
suitable for 76.5 mm / 80mm. / require size pole top having
sufficient fasteners for fixing the brackets and having spread of
mtr. length with suitable rise as per site condition & suitable
welded stiffener reducer and nipple with check nut complete
painted with one coat of Red oxide / PU base primer and two coats
of Aluminium / PU paint. paint with following nos of arms.[A]
Single Arm bracket 1 Mtr
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[327] Supplying & erecting approved make Digital time switch having 2.00 Ea. 3168.37
lithium cell 6 years operative and operate battery backup
channel day clock with 14 memory programme, suitable to
operate on 240V + 5%, 16A with, floating contacts Minimum
switching setup time 1 minimum & LCD display. Also comprised
permanent ON/OFF switching. Programming switches & housed in
fire proof thermoplastic enclosure & transparent cover erected as
required with necessary connection erected as directed.
[328] Supplying & erecting power contactor ,AC3 duty for time switch 2.00 Ea. 2782.55
complete erected as per direction. [D] 4 pole 440V 40 Amp. Cat III
[329] Providing and erecting Inverter based approved make split air- 2.00 Ea. 60709.08
conditioning unit consisting of condensing unit with variable speed
fan motor, inverter type hermetically sealed rotary compressor
with accessories etc. duly connected separately erected
evaporating unit and blower motor with its accessories by means
of extra supplied proper insulated copper tubing,drain PVC pipes
suitable for ( cost includes Eco Friendly green gas charging and 15A
plug top & Remote Control & MS Stand) with necessary core
cutting.(2)For ISEER Range (KWH/KWH)(4.0 to 4.49)(B) for 1.5 ton
capacity - Premium Cat.
[330] Supplying and erecting insulated pair of soft copper tubing open or 14.00 Rmtr. 1158.47
concealed including power and control cable,necessary PVC drain
pipes for Split AC machine up to 4 TR capacity
[331] Providing & erecting water cooler having storage capacity 150 Ltr. 4.00 Ea. 61482.74
& cooling capacity 150 Ltr.per hour @ an ambient temp of 45˚ C.
The outlet temp. of the water should drop by 15˚C within a hour,
The water cooler should be comprising of hermetically sealed
compressor, fan motor, condensing unit, water tank surrounded
by evaporating, coil, thermostats, relay etc.complete with
necessary inlet & outlet connection. The body of water cooler will
be made from Stainless Steel. and ISI Certified.
[332] Supplying & erecting 5 stage single reverse osmosis water 4.00 Ea. 29187.99
purification system with M.S. powder coated frame, prefilter
housing with 'O' ring presediment filter GAC filter, carbon filter
suitable buster DC pump capacity 80 psi, mention with 40 psi inline
type post carbon filter auto low & high pressure switches with
following size of storage tank & LPH capacity & erected as
directed.[C] 50 Ltr / Hr with 150 psi 2 nos booster pump
[333] Supply and Erecting of Static Stabilizer suitable for following 2.00 Ea. 3030.00
capacity of A.C Machine the Stabilizer Must have Minimum
Technical Specification are Input working Single Phase Voltage
Range Up to 150V-280V.50Hz, Output Voltage Range Up to 200V-
240V,50Hz,Autoreset Facility,LED Display for Indicating
Voltage,Spike/Surge Protection,Time Delay Facility,Proper Wall
Mount Facility with Required Accessries & on site 3 year
Replacement/Repairing Warranty.(1) For 1.5Ton Thermal Overload
Protection 12 Amp.
[334] Supplying and erecting approved make panel mounting type 15.00 Ea. 1275.63
Digital Voltmeter having 3 digits LED display, 0 to 750 AC Volts
range erected on existing panel board with all connection, wiring
etc .with manufacturers calibration certificate.
[335] Supplying and erecting approved make panel mounting type 15.00 Ea. 1558.43
Digital Ammeter having 3 digits LED display, external CT operated,
calibrated for 0 to 1000 Amps suitable to operate on 500 Volt AC
erected on existing panel board with all connection, wiring etc
.with manufacturers calibration certificate.
[336] Supplying and erecting Ammeter / Voltmeter selector switch for 3 30.00 Ea. 317.14
phase AC Supply 500 V on existing panel board with necessary
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[337] Providing & erecting L.T. Current Transformer with bar primary 45.00 Ea. 274.72
50/5 to 1000/5 ratio 15 VA burden erected in existing CRCA box
duly secured with insulating materials connected to the meter
[338] Supplying and erecting approved make suitable panel indicator 45.00 Ea. 43.43
LED type lamp, lens cover, complete erected with necessary
[339] Providing & erecting open well horizontal mono block pump set 2.00 Ea. 20621.17
with cast iron body, complete for three phase submersible motor
having.[D] For 5 HP 3 phase open well horizontal mono block
pump set suitable for 1350 LPM to 310 LPM @ 10 to 42 Mtr head
suitable for 50/65 mm dia delivery pipe.Cat.II
[340] Supplying & erecting approved make motor control cubical panel 2.00 Ea. 7722.46
(Direct - on - line) made from 16 G. CRCA sheet duly epoxy powder
painted inside and outside with hinged doors and locking,
arrangement consisting of suitable size of ON- OFF isolator (AC -
3/23duty) main fuses, single phasing preventer, indicating lamps
for R- Y - B phases, overload relay, Automatic water level
controller, Ammeter, Voltmeter each with two way selector
switch incoming, wires duly socket crimped, main contactor &
overload relay, start - stop push buttons, to be erected on angle
iron frame grouted on wall as directed. The isolator, overload relay
& contactors will be of L & T, Siemens or BCH make only. (A) DOL
[341] Supplying & erecting approved make 3 phase motor control 1.00 Ea. 13605.71
cubical panel ( Star - Delta) made from16 G. CRCA sheet duly
painted with epoxy powder painted inside and outside with hinged
doors and locking arrangement, consisting of suitable size of ON-
OFF isolator (AC - 3/23 duty) main fuses, single phasing preventer
cum water level. Guard (Complete unit), Toggle switch to by pass
Single phase preventer cum WLG, indicating lamps for R- Y- B
phases, over load relay, Automatic water level controller,
Ammeter & Voltmeter each with two way selector switch incoming
wires duly socket Crimped, Panel to be erected on angle iron
frame grouted on wall as directed. Star Delta & main contactor,
overload relay, thermal / Electronic Star delta cutoff timer, start -
stop push buttons. The isolator overload relay & contactors of L&
T, Siemens or Cuttler Hamer make only. Panel to be erected on
angle iron frame ground on wall.(B) S/D up to 10 H.P.
[342] S.I.T.C. submersible pump set suitable for bore of 150 mm dia or 1.00 Ea. 43625.94
more having 3 phase motor capacity not less than 10 HP with
following capacity. Lifting and Lowering taken extra.[A] 10 stage
575 to 480 LPM discharge at 60 to 70 mtr head for 65 mm dia
delivery pipe.Cat.III
[343] Lowering of submersible motor pump set at the depth of following 2.00 Job. 856.48
,complete with required. Nos. and size of casing pipes erected by
means of proper chain pulley block & pipe wrenches after
checking of threads of each pipe with coupling to take the load of
the pump set and pipe assembly filled up with water.(d)For Open
well Horizontal submersible pump set for sump well. (i) 1 HP to
[344] Lowering of submersible motor pump set at the depth of following 1.00 Job. 2568.43
,complete with required. Nos. and size of casing pipes erected by
means of proper chain pulley block & pipe wrenches after
checking of threads of each pipe with coupling to take the load of
the pump set and pipe assembly filled up with water.(B)Above
mtrs. and Up to 120 mtrs. .
[345] Providing and erecting ISI marked PVC insulated PVC Sheathed 30.00 Mtr. 146.45
Flat flexible Submersible copper cable approved make of
following Size.(C) 3 Core x 4 Sq. mm.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[346] Providing and erecting ISI marked PVC insulated PVC Sheathed 100.00 Mtr. 295.93
Flat flexible Submersible copper cable approved make of
following Size.(E) 3 Core x 10 Sq. mm.
[347] Providing Water proof straight Joint in PVC insulated flat flexible 4.00 Ea. 189.88
copper cable by using insulating material, water proofing material,
& making the joint complete. (A) Up to 10Sq. mm
[348] Supplying of following size of HEAVY UPVC column pipe with 80.00 Mtr. 493.89
coupler and wire lock.[C] 65 mm dia.
[349] Supply of following size of TOP & BOTTOM accessories i.e. Adaptor 1.00 Per set 1900.82
set (CI) long, pump guard set, starter pipe Rubber ring for
submersible pump & UPVC column pipe as directed by Engineer -
in - charge with necessary plumbing as desired.[E] 65 mm dia
[350] Supply, Installation, Testing and Commissioning (SITC) of Silent 1.00 Ea. 2462248.70
Type Diesel Generating (DG) Set(s) of prime power rating (kVA) as
specified, complete as a packaged system, conforming to CPCB IV+
(or better) emission norms, and complying with all applicable
statutory requirements, codes and standards including (but not
limited to) IS 4722:1968, IS 13364 (Part 2) and BS 5514 (latest
editions/amendments). The DG set shall be suitable for 415 V
±10%, 50 Hz ±5%, 3-phase, 4-wire operation at 0.8 lagging power
factor, 1500 RPM, for tropical conditions, and shall be capable of
delivering 10% overload for one (1) hour after twelve (12) hours of
continuous operation (ISO 8528), unless otherwise stated by the
OEM. The scope shall include complete accessories,
interconnections, foundations/anti-vibration arrangements,
exhaust system, acoustic enclosure, earthing (as required),
consumables for first commissioning, and all works necessary to
render the installation fully functional and compliant, as directed
by the Engineer-in-Charge (EIC). Factory testing shall be carried out
with fuel and load bank at 0.8 power factor and the DG set shall be
offered for inspection prior to dispatch. The DG set shall be
provided with a durable QR code/label fixed on the
enclosure/control panel, linking to a document repository
containing (as a minimum) approved GA drawings, wiring
diagrams, foundation and installation details, OEM catalogues,
operating & maintenance manuals, factory test reports, type test
certificates (where applicable), warranty certificate,
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
geo-tag of manufacturing location, and rating plate data as per
relevant IS/BS/ISO requirements. The OEM/Contractor shall
provide a Remote Monitoring System (RMS) with minimum one (1)
year connectivity (SIM/data plan/server access as applicable),
including dashboard access, user ID/password, and data download
facility. RMS shall, at minimum, capture and report: DG status
(Auto/Manual/Off), start/stop events, kW/kVA/kVAR, V/I/Hz, PF,
run hours, fuel level, battery voltage, alarms/trips with time
stamp, and GPS/location (where supported). All
licences/subscriptions required for the stated period shall be
included in the quoted price.
(A) Diesel Engine:Turbocharged, 4-stroke, water-cooled, multi-
cylinder diesel engine, suitably rated for the specified DG set prime
rating at site conditions, complete with dynamically balanced
flywheel, heavy-duty engine mounting, and electric starting
arrangement. The engine governing shall be electronic
(isochronous/droop as per OEM standard) and shall comply with
ISO 8528/BS 5514 requirements for steady-state speed regulation.
Engine shall be complete with dry type air cleaner with restriction
indicator, lube oil cooler (if required), radiator/cooling package (as
applicable), and all sensors/switches required for protections and
annunciation. The engine shall be capable of 10% overload for one
(1) hour after twelve (12) hours continuous operation and shall be
suitable for continuous duty under tropical ambient conditions.
The offered engine model shall be CPCB IV+ compliant and shall be
supplied with complete emission control/after-treatment system
(including DEF/urea dosing where applicable) along with all
accessories, tanks, pumps, heaters and controls required for
compliant operation. The supply shall include first fill of lubricating
oil, coolant and consumables required for initial commissioning
and testing. All fasteners, couplings, guards, hoses and
standard/recommended accessories required for safe and reliable
operation shall be included and shall be subject to
inspection/approval by the EIC.(B) Engine-Mounted
Instrumentation/Control Panel:Engine-mounted
instrument/control panel shall be microprocessor based, with
LCD/LED display, event log and alarm/trip annunciation, complete
with all wiring, harnesses and terminations.
Indications/protections shall include (minimum) the following and
any additional protections recommended by the OEM: (i)
Start/Stop key switch and/or push buttons with emergency stop;
(ii) Output breaker: suitably rated 4-pole ACB/MCCB/MCB as
applicable, with minimum 25 kA rupturing capacity (or as per fault
level at site, whichever is higher), with shunt trip where required;
(iii) Jacket water/coolant temperature – indication and high
temperature alarm/trip; (iv) Lube oil pressure – indication and low
pressure alarm/trip; (v) Lube oil temperature (where provided) –
indication/alarm; (vi) Battery charging indication, battery voltage
indication and charging failure alarm;
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
(vii) Engine speed (RPM) indication and overspeed trip; (viii)
Engine running hours meter (non-resettable); (ix) Fuel level
indication and low fuel alarm; (x) Fail-to-start / crank fail alarm; (xi)
Under/over frequency and under/over voltage protection
(alternator side) as applicable; (xii) Common alarm and common
trip indication with potential-free contacts for BMS/remote
annunciation. All meters/indications shall be of proven industrial
quality and the panel shall be wired, ferruled and labelled. The
contractor shall submit wiring diagrams, protection settings and
datasheets for approval prior to dispatch/installation.(C)
Alternator:Synchronous, brushless alternator of appropriate kVA
rating, 415 V, 3-phase, 50 Hz, 1500 RPM, 0.8 lagging PF, continuous
duty, dynamically balanced rotor, self-cooled, self-excited and AVR
regulated. Enclosure shall be SPDP, minimum IP23. Insulation shall
be Class H with suitable tropicalization; temperature rise shall be
within limits of the applicable standard. The alternator shall
comply with IS 13364 (Part 2), IS 4722 and/or BS 2613 (latest), as
applicable. Voltage regulation with AVR shall be within ±1.0%
(steady state) or OEM standard whichever is better. The alternator
shall be capable of 10% overload for one (1) hour after twelve (12)
hours of continuous operation. Harmonic distortion shall be
suitable for non-linear loads; alternator shall be equipped with
appropriate AVR features (e.g., soft start, UFRO) and shall be
suitable for motor starting duties typical to the installation.
Terminals shall be brought out to a terminal box with
adequate space for termination and shall include earthing
terminals. All routine/type test certificates (as applicable) shall be
submitted for acceptance.(D) Base Frame & Foundation: Engine
and alternator shall be mounted on a suitably designed, fabricated
MS channel base frame with stiffeners, lifting arrangement and
coupling guard, duly painted/treated for corrosion protection. The
set shall be installed on an adequately designed cement concrete
foundation/pedestal with anchor bolts, pockets, grouting and anti-
vibration mounts (AVMs) / spring isolators as per OEM
recommendations and site conditions. Vibration levels shall be
within OEM permissible limits. The contractor shall be responsible
for alignment, levelling, tightening torque and re-check after load
trial, complete in all respects.(E) Fuel Tank: In-built/base fuel tank
fabricated from minimum 3 mm thick MS sheet, duly leak-tested,
complete with filling arrangement, vent, drain, cleaning opening,
level indication and isolation valve(s). The capacity shall be
adequate for minimum eight (8) hours continuous operation at full
load. Fuel piping between tank and engine shall be MS ‘C’ class
pipes of suitable diameter with compatible flexible connections
(where required), complete with all valves, clamps, supports,
unions and fittings. Any additional safety provisions required by
local fire authority/UGVCL/competent authority (such as double
wall/bunding, flame arrestor, etc.) shall be provided within the
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
(F) Exhaust System: Heavy-duty residential type exhaust silencer
suitable for CPCB IV+ installation (with DEF/after-treatment system
wherever applicable) along with exhaust piping of required length,
bends, supports and flexible bellow, complete with rain cap, drain
arrangement and all accessories. Exhaust piping shall be thermally
insulated/lagged and cladded where required to ensure personnel
safety and to limit heat radiation inside the DG room/enclosure.
The complete exhaust arrangement shall be designed such that
engine exhaust back pressure remains within OEM permissible
limits and shall comply with applicable statutory and safety
(G) Starting System:12 V / 24 V DC electric starting system (as per
OEM design) comprising starter motor(s), battery
charger/alternator charging arrangement, relays, cabling and
terminals, complete with maintenance-free batteries of suitable
Ah capacity to ensure minimum three (3) consecutive cranking
attempts. System shall include battery isolator and indication of
charging healthy/failure. All battery interconnections shall be with
crimped lugs, insulated sleeves and proper supports, complete in
all respects.(H) Acoustic and Weatherproof Enclosure: Acoustic
enclosure shall be factory-fabricated, weatherproof and corrosion
protected, suitable for outdoor installation, with minimum IP65
protection (or better) for the enclosure body. Enclosure design
shall provide adequate fresh air intake and hot air discharge for
engine radiator and alternator cooling such that the internal
temperature rise remains within
OEM limits at full load. Provision shall be made for safe
access/maintenance including lockable doors, viewing window
(where provided), emergency stop access, and cable entry glands.
Noise level of the complete DG set with enclosure shall not exceed
75 dB(A) measured at 1.0 m distance in free field conditions, in
accordance with applicable CPCB requirements. The enclosure
shall comply with CPCB IV+ (or better) requirements and other
applicable local rules/regulations. All louvers, acoustic
infill/insulation, fasteners and sealing arrangements shall be of fire-
retardant/industrial grade as per OEM standard. Any deviation
from the specified noise/IP requirements shall be treated as non-
compliance unless explicitly approved by the EIC in writing.
Erection, testing, commissioning and satisfactory performance
demonstration shall be carried out as per site requirements and as
directed by the Engineer-in-Charge. The scope shall include pre-
commissioning checks, insulation resistance tests, no-load and
load trials, safety/protection checks, and performance test on load
bank (where directed) with submission of test records. The
contractor shall provide initial consumables including first fill of
diesel fuel (minimum up to 80% of fuel tank capacity), lubricating
oil, coolant, etc. required for commissioning and the specified
tests. The bidder/OEM shall provide comprehensive
warranty/guarantee for the complete DG system (engine,
alternator, control panels, RMS, enclosure and all accessories) for
a minimum period of two
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
(2) years from the date of commissioning/handing over, whichever
is later, covering defects in materials and workmanship. During
warranty, all spares/repairs/replacements and visits required to
maintain the DG set in serviceable condition shall be carried out at
no additional cost. All necessary statutory approvals, inspections,
testing and certification from the Electrical Inspector/competent
authority (including provision, testing and sealing of energy
meter(s) wherever applicable) shall be arranged and obtained by
the contractor within the quoted scope and time, at no extra cost.
Required O&M manuals, as-built drawings, warranty certificates
and training to operating staff shall be provided prior to handing
over.Note: The DG set specifications shall comply with the latest
CPCB guidelines/notifications and all applicable local
rules/regulations prevailing as on the last date of tender
submission applicable local rules/regulations prevailing as on the
last date of tender submission,(R) Continuous rating of 250 KVA
,BHP not less than 309 BHP.
[351] AMF Panel:Free standing floor mounted IP 42 automatic mains 1.00 Ea. 222714.09
failure control panel including auto by-pass, suitable for KVA as
below for silent type DG set complete with relays, timers, set of
CTs for metering & protection and energy analyser to indicate
currents, phase and line voltages, frequency, power factor,
KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase &
Total), KW (MFM) & provision for overload, short circuit,
restricted earth fault, under frequency, all complete and
inter locking and communication/ Ethernet /RS485/SNMP
port open protocol for BMS integration including suitable
software, the panel shall be of DG Set. as per approved by
Engineering in charge and including the following: 1. Suitable
numbers and appropriate capacity 4 ACB/ MCCB with electronic
release for O/C & E/F and shunt trip. (Icu=100%Ics) (Not below
25KA Breaking Capacity at 415Volts), (Total Three Breakers).2.
Auto/Manual/Test/Off selector switch.3. Protection for under
and over voltage phase reversal (2 nos Over voltage relay,
Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets
of current transformers 15 P 10 accuracy for protection and 15 VA
class-I for metering.5. Energy analyser unit to indicate current,
Voltage( L- N & L_L), kW, kVA (Phase & Total), Frequency, KWH,
PF.6. LED Indicating lamps for load on mains and load on set.7.
Fuse/ MCB for instruments.8. Battery charger, complete with
transformer/ rectifier, D.C. voltmeter and ammeter, selector
switch for trickle, off and boost and current adjustment.
9. Control/Signal/Multi core/Communication Cables between DG
Set and AMF Panel upto 20 Mtr.10. Main supply failure
monitor.11. Supply failure timer.12. Restoration timer.13. Control
unit with three impulse automatic engine start/stop and failure
to start lockout.14. Impulse counter with locking and reset
facility.15. ON/OFF/Control circuit switch with indicator.16.
Audio/Video annunciation for (i) High water temperature.(ii) Low
lubricating oil pressure.(iii) Engine over speed.(iv) Engine fails to
start.(v) Full load/maximum load warning.16. Protection for
over/under Frequency, Loss of AC sensing, Over Current,
Unbalancing load with suitable number of relays and
accessories.17. Maintenance notification based on Engine Run
Hour & due date.18. Load Management through PLC to achieve
auto opening and closing of incomer breakers, bus coupler
switching of essential panel , interlocking providing signal to
AMF Panel for load status and AMF shall give command to
DG Set to auto start / auto stop depending upon load status
and requirement etc. and necessary hardware and software
required to perform the operation shall be provided by the
contractor including all control wiring.(D) AMF Control Panel
for200 kVA/250 KVA3 phase DG Set.
Rate (Exclusive
Item Description of Item (with brief specification and reference GST)
Quantity Unit Amount
No. to book of specifications)
[352] Design, Supplying, installing, testing of factory fabricated ready 1.00 Ea. 288878.18
made Three phase APFC Panel Cubical Panel fabrication should be
type tested as per IEC 61921, 61439:1&2 Capacitor Duty Contactor
for switching as per following Steps Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault
protection Incomer Switch of MCCB type Icu=Ics=50KA at 400/440
Volts, with OC, SC, internal earth fault protection,Copper tinned
insulated Busbar,Cubical panel should be indoor type with IP
and IK 10,Metalized polypropylene film tye3-phase 550Volt
Capacitor,De tuning Reactor for each capacitor,Panel having Short
Circuit and Overload protection,Each step Capacitor having
suitable MCB with Sc, OL, internal earth fault relay,Each stage
having Stage Contactor (Capacitor load rating),PF regulator master
controller having suitable steps with LCD display, Rs
Communication port, Indication LED Lamps for main incomer and
ON-OFF for each capacitor bank,MS Chanel for Floor mounting,
Cable entry as per site situation,Cooling fans for panel.(C)
Nine Crore Thirteen Lakh Thirty Thousand Three Hundred Seven Rupees and Fifty Nine Paisa Only
I/We am/are willing to carry out the work at…………………………………………….% above/below percent (Should be written in figures and words)
of the estimated rate mentioned above. Amount of my / our tender works out as under.
Estimated amount put to tender Estimated amount put to tender
Deduct…………………………% below Add…………………………% Above
In Worlds In Worlds
(* Please strike out whichever is not applicable).
1. The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which
no extra payment shall be made.
2. The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3. GST and Income tax TDS will be deducted at a source while making payments of bills
4. In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement
Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items where there is a change as per actual mix design
the cost of difference of cement consumption have been deducted from the rate of original item at the rate of input rate
mentioned in all the tender.
5. Credit of dismantled materials of amount of Rs. 0.00/- must be recovered from contractor's 1st R.A. bill.
6. All duties, taxes, and other levies except GST payable by the contractor under the contract, or for any other cause shall be included
in the rates, prices and total Bid Price submitted by the Bidder. (GST will be paid extra)
Dated Signature of Dy. Executive Engineer Executive Engineer
the Contractor. R & B Sub Division R & B Division
Kapadwanj Kheda
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1_ SBD Tender Documents.pdf
2_ PQ Criterias.pdf
3_ BOQ Price-Bids.pdf
4_ Index Specification.pdf
5_ Technical Specification.pdf
6_ Govt Circulars.pdf
7_ Building Specification.pdf
8_ Electrical Specification.pdf
9_ Electrical MOU.pdf
10_ Electrical Makelists.pdf
11_ Drawings.pdf
12_ Testing Schedule.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .