| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 CrAccepted-AOC | ₹6.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹7.2 Cr+₹25.1 L (3.62%)Rejected-Finance | ₹7.2 Cr+₹25.1 L (3.62%) | L2 | Rejected-Finance L2 |
| 3 | L3₹7.6 Cr+₹66.8 L (9.65%)Rejected-Finance 302 3 FLOOR DLF TOWER B JASOLA NEW DELHI 110025 | ₹7.6 Cr+₹66.8 L (9.65%) | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical S4018 NO 5 KATHIRESAN STREET GNANAMURTHY NAGAR AMBATTUR CHENNAI 600 053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | - | - | Rejected-Technical Technically Disqualified |
Tender Value
₹7.7 Cr
EMD Value
₹2 L
Closing Date
15 Nov 2021, 5:00 pmClosed
MANAGING DIRECTOR
STEEL INDUSTRIALS KERALA LTD. ATHANI P.O THRISSUR- 680 581
Supply, Installation, Testing ,Commissioning including 3 years AMC for the Facade Illumination of Public Landmark Buildings in Thiruvananthapuram City Travancore Heritage Project Zone D
2021_SILK_447641_1
SILK/PEED/S-3634/2021-22/620
Open Tender
Miscellaneous Works
Item Rate
240 days
Thiruvananthapuram
As per tender documents
5 documents required · 5 mandatory
₹11,800
₹2 L
16 Mar 2022
23 Oct 2021
16 Nov 2021
23 Oct 2021
15 Nov 2021
23 Oct 2021
23 Oct 2021 - 15 Nov 2021
Amount
Supply, Installation, testing & commissioning of compartmentalized type THERMOPLASTIC OUTDOOR (IP66) TYPE Lighting / Power Distribution boards (maximum load 2KW). The unit rate shall include loading/unloading, shifting from site store to the place of installation, assembling the Panel including mounting & wiring of loose parts by contractor. Cable entry and outgoing are only with suitable sizes of screw less glands, including with all accessories copper bus bar, din rails, earth links, neutral links, glands, locks, connectors, RYB indicator, Digital VAF meter, under-over voltage protection, SPD, 2 Channel din rail mounted astronomical timer with suitable contactor configuration for operation complete with all respects. Distribution board should have the space of 24 modules for MCBs.
Supply, Installation, testing & commissioning of compartmentalized type THERMOPLASTIC OUTDOOR (IP66) TYPE Lighting / Power Distribution boards (maximum load 6KW). The unit rate shall include loading/unloading, shifting from site store to the place of installation, assembling the Panel including mounting & wiring of loose parts by contractor. Cable entry and outgoing are only with suitable sizes of screw less glands, including with all accessories copper bus bar, din rails, earth links, neutral links, glands, locks, connectors, RYB indicator, Digital VAF meter, under-over voltage protection, SPD, 2 Channel din rail mounted astronomical timer with suitable contactor configuration for operation complete with all respects. Distribution board should have the space of 24 modules for MCBs.
Supply, Installation, testing & commissioning of compartmentalized type THERMOPLASTIC OUTDOOR (IP66) TYPE Lighting / Power Distribution boards (maximum load 10KW). The unit rate shall include loading/unloading, shifting from site store to the place of installation, assembling the Panel including mounting & wiring of loose parts by contractor. Cable entry and outgoing are only with suitable sizes of screw less glands, including with all accessories copper bus bar, din rails, earth links, neutral links, glands, locks, connectors, RYB indicator, Digital VAF meter, under-over voltage protection, SPD, 2 Channel din rail mounted astronomical timer with suitable contactor configuration for operation complete with all respects. Distribution board should have the space of 24 modules for MCBs.
Supply, Installation, testing & commissioning of compartmentalized type THERMOPLASTIC OUTDOOR (IP66) TYPE Lighting / Power Distribution boards (maximum load 20KW). The unit rate shall include loading/unloading, shifting from site store to the place of installation, assembling the Panel including mounting & wiring of loose parts by contractor. Cable entry and outgoing are only with suitable sizes of screw less glands, including with all accessories copper bus bar, din rails, earth links, neutral links, glands, locks, connectors, RYB indicator, Digital VAF meter, under-over voltage protection, SPD, 2 Channel din rail mounted astronomical timer with suitable contactor configuration for operation complete with all respects. Distribution board should have the space of 24 modules for MCBs.
Supply,installation, testing and commissioning of 20KVA Servo voltage stablizer (IP65), 3-phase, Copper winding, 50HZ Frequency, Unbalanced input voltage and unbalanced load, Volt/ampere meter CT's, input voltage range- 360V-480V, output voltage range- 410-420V adjustable
Supply,installation, testing and commissioning of 10KVA Servo voltage stablizer (IP65), 3-phase, Copper winding, 50HZ Frequency, Unbalanced input voltage and unbalanced load, Volt/ampere meter CT's, input voltage range- 360V-480V, output voltage range- 410-420V adjustable
Supply, installation, testing and commissioning of 12 Module Distribution box (IP65) with terminal block, earth link, neutral link, glands and complete with all required accessories and hardware to complete the job in all resepcts.Location of Distribution box will be as per site and purpose is to distribute electrical supply to termination boxes.
Supply, installation, testing and commissioning of 18 Module Distribution box (IP65) with terminal block, earth link, neutral link, glands and complete with all required accessories and hardware to complete the job in all resepcts.Location of Distribution box will be as per site and purpose is to distribute electrical supply to termination boxes.
Supply, installation, testing and commissioning of 24 Module Distribution box (IP65) with terminal block, earth link, neutral link, glands and complete with all required accessories and hardware to complete the job in all resepcts.Location of Distribution box will be as per site and purpose is to distribute electrical supply to termination boxes.
Supply, installation, testing and commissioning of the Termination junction box (IP65) with terminal block, glands complete with all required accessories and hardware to complete the job in all resepcts : Incoming - 1 no. 5 core 4.0/2.5 sq mm copper armoured cable Outgoing - 8 nos. 3 core 2.5/1.5 sq mm copper armoured cable .Termination boxes are being used to distribute electrical supply to Luminaires and LED drivers.
Supply, installation, testing and commissioning of the Termination junction box (IP65) with terminal block, glands complete with all required accessories and hardware to complete the job in all resepcts : Incoming - 1 no. 5 core 4.0/2.5 sq mm copper armoured cable Outgoing - 4 nos. 3 core 2.5/1.5 sq mm copper armoured cable .Termination boxes are being used to distribute electrical supply to Luminaires and LED drivers.
Supply, installation, testing and commissioning of Empty box (IP65) with mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. built in dimensions W 170 x H 220 x D 96 (Tolerance ± 10%).Empty boxes are to keep the LED drivers remotely.
Supply, installation, testing and commissioning of Empty box (IP65) with mounting plate, glands and complete with all required accessories and hardware to complete the job in all resepcts. built-in dimensions W 215 x H 320 x D 106 mm (Tolerance ± 10%)Empty boxes are to keep the LED drivers remotely.
Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 4 sq.mm.XLPE Cables can also be used.
Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 6 sq. mm.XLPE Cables can also be used.
Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 10 sq mm.XLPE Cables can also be used.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp.XLPE Cables can also be used.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp.XLPE Cables can also be used.
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp.XLPE Cables can also be used.
Supply of 1.5 sqmm 2 core PVC / XLPE insulated armoured control cables with<br>copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE 2 core 1.5 sq.mm
Supply of 1.5 sqmm 3 core PVC / XLPE insulated armoured control cables with<br>copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE 3 core 1.5 sq.mm
Supply of 2.5 sqmm 3 core PVC / XLPE insulated armoured control cables with<br>copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE 3 core 2.5 sq.mm
Supply of 2.5 sqmm 2 core PVC / XLPE insulated armoured control cables with<br>copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE 2 core 2.5 sq.mm
Supply of 2.5 sqmm 4 core PVC / XLPE insulated armoured control cables with<br>copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE 4 core 2.5 sq.mm
Supply of 2.5 sqmm 5 core PVC / XLPE insulated armoured control cables with<br>copper conductors for working votages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE 5 core 2.5 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade offollowing size direct in ground including excavation and refilling the trench etc as required, butexcluding sand cushioning and protective covering.Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recessincluding painting in case of surface conduit, or cutting the wall and making good the same incase of recessed conduit as required.25 mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
LUMINAIRES
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant) Luminaire Dimensions (mm) (Tolerance ± 10%) 1000 x 30 x 30 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 30x60 Max Power Consumption (W) 9 CCT (Kelvin) 2700 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant) Luminaire Dimensions (mm) (Tolerance ± 10%) 1000 x 30 x 30 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 10x30 Max Power Consumption (W) 9 CCT (Kelvin) 2700 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 1000 x 30 x 30 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1000 Optics (Degree) (Tolerance ± 10%) 10x30 Max Power Consumption (W) 18 CCT (Kelvin) 2200 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x 35 x 45 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 10x30 Max Power Consumption (W) 10 CCT (Kelvin) 2700 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x35 x 45 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 10x30 Max Power Consumption (W) 9 CCT (Kelvin) 3000 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x50 x 50 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1000 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 17 CCT (Kelvin) 3000 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x50 x 70 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1500 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 25 CCT (Kelvin) 3000 Driver Non Integral
Supply of exterior rated architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be remote non dimmable with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x35 x 45 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 10x50 Max Power Consumption (W) 9 CCT (Kelvin) 2200 Driver Non Integral
Supply of exterior rated dynamic color changeable architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be non integral with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 1000 x 35 x 45 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) Diffused Max Power Consumption (W) 17 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non Integral
Supply of exterior rated dynamic color changeable architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be non integral with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 X 50 X50 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 30 X 40 Max Power Consumption (W) 14 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Integral
Supply of exterior rated dynamic color changeable architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be non integral with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x 50 x 70 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1000 Optics (Degree) (Tolerance ± 10%) 5 x 30 Max Power Consumption (W) 33 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non Integral
Supply of exterior rated dynamic color changeable architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be non integral with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 500 x 50 x 70 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1000 Optics (Degree) (Tolerance ± 10%) 5x30 Max Power Consumption (W) 33 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non Integral
Supply of exterior rated dynamic color changeable architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be integral with PF>0.9 & THD<20%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x 50 x 50 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 10x30 Max Power Consumption (W) 14 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Integral
Supply of exterior rated dynamic color changeable architectural linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be non Integral with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 300 x 50 x 70 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 17 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non-Integral
Supply of exterior rated architectural dynamic color changeable linear light complete with visor and adjustable mounting brackets/ clamps (as per application) . The housing material should be extruded aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be non Integral with PF>0.9 & THD<20%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) 500 x 50 x 70 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1000 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 33 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non-Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø250 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 5000 Optics (Degree) (Tolerance ± 10%) 10 X 30 Max Power Consumption (W) 83 CCT (Kelvin) 3000 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø175 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) 30 Max Power Consumption (W) 9 CCT (Kelvin) 3000 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø200 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1500 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 25 CCT (Kelvin) 3000 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø175 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1200 Optics (Degree) (Tolerance ± 10%) 26 Max Power Consumption (W) 20 CCT (Kelvin) 3000 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø175 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 600 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 11 CCT (Kelvin) 2200 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø175 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 1000 Optics (Degree) (Tolerance ± 10%) 26 Max Power Consumption (W) 18 CCT (Kelvin) 2200 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø175 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 600 Optics (Degree) (Tolerance ± 10%) 26 Max Power Consumption (W) 11 CCT (Kelvin) 2200 Driver Integral
Supply of exterior rated architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø250 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 3000 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 55 CCT (Kelvin) 2200 Driver Integral
Supply, installation, testing & commissioning of exterior rated dynamic color changeable architectural round Flood light complete with snoot and adjustable mounting brackets/ clamps (as per application) . The housing material should be Die cast Aluminium, powder-coated black finishwith anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral non dimmable with PF>0.9 & THD<15%. Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test.To confirm the anti-corrosion ability of material and material coating self declaration is mandatory.This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) ø175 IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 700 Optics (Degree) (Tolerance ± 10%) 10 Max Power Consumption (W) 20 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Integral
Supply, installation, testing & commissioning of exterior rated dynamic color changeable architectural customized light complete and mounting brackets/ clamps (as per application) . The housing material should be silicon. It should have CRI>80 , SDCM≤4. The driver should be non Integral and DMX dimmable with PF>0.9 & THD<15%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. Dimension should not be greter than 8 mm (Width) * 15 mm Height. Length will be in running meters. Lumen should be 500 lm (Having tolerance of five percent). Wattage should not be greater than 17W. Fixture should have side view optics. The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) Side Emitting Strip IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) Diffused Max Power Consumption (W) 17 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non -Integral
Supply, installation, testing & commissioning of exterior rated dynamic color changeable architectural customized light complete and mounting brackets/ clamps (as per application) . The housing material should be Die cast aluminum, powder-coated finish, luminaire body color should be similar to the facade color surface where luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses, Clear tempered glass cover. It should have CRI>80 , SDCM≤4. The driver should be Integral and dimmable with PF>0.9 & THD<15%. IP65 driver boxes, leader cables, jumper cables, IP66 connectorer are inclusive.Operating temperature should be of -20°C to 50°C range. Lifetime of luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self declaration of ASTM B117 for 500 hours of salt spray test. This includes all the required hardware, equiepment/controller, software etc. for successful operation of the color changing luminaire. Dimension should not be greter than 120mm*110mm*70mm. Lumen shoul be 500 lm (Having tolerance of five percent). Wattage should not be greater than 17W. Fixture should have wall washer optics of 360 degree with RGBW (W-3000 Kelvin). The luminaire should be BIS certified & self declaration of CE certification,Manufacturer should take responsibility for the compliance of all LED fixtures with all applicable health, safety, performance and environmental requirements. Hence self declaration of CE certifiation is mandatory Restriction of hazardous substances- Compliant with (RoHS),2011/65/EU : EN50581:2012 ; EN 60598-1: 2015+ A1:2018; Electromagnetic compatibility Directive (EMC) 2014/30/EU EN 55015:2013/A1:2015 EN 61000-3-2:2014 EN 61000-3-3:2013 Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015 (All the technical parameters of luminaire need approval from lighting consultant); Luminaire Dimensions (mm) (Tolerance ± 10%) Customized IP Rating 66 IK Rating IK06 Lumen (Tolerance ± 10%) 500 Optics (Degree) (Tolerance ± 10%) Washer Optics Max Power Consumption (W) 17 CCT (Kelvin) RGBW (W-3000 Kelvin) Driver Non -Integral See Attached Reference Image.
Supply & installation of Cast Iron Decorative Lighting Pole of 5200mm Cast Irion embellishments. The Pole shalll have a tapered construction with the aesthetically fluted design and with embellishments at appropriate points throughout the pole which runs the inner pipe of Ø114.3mm, Ø76.1mm and Ø60.3mm from the base plate. The base plate of the of the pole shall beMS 250 mm x 250mm, 12mm thick with MS Pipe and shall be facilitated with elongated slots to suit the 500mm, J-type, M16 bolts that shall be provided with suitable nuts and plain washers. The cable entry provided at the base plate shall be Ø70mm. A base compartment with a door 432mm L x 102mm W iscontoured to the poles's shape housing the gear tray, prewired with MCB, terminal connectors for LILO arrangement. All pole sections are welded using special v groove technique by certified welders using high end MIG welding process. The surface finish of the pole shall be epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Luminaire Dimensions (mm) (Tolerance ± 10%) 5 mtr Decorative Pole See Attached Reference Image.
Supply and installation of 8 mtr. high mild Steel galvanized tubular pole. Dia 114mm & 4mm thick. pole should have a service window and fixed base plate at bottom profile. Pole is primer coated and PU painted. Same colour as of fixture. Luminaire Dimensions (mm) (Tolerance ± 10%) 8 mtr Pole See Attached Reference Image.
Supply & installation of Cast Iron Decorative Lighting Pole of 2910mm with Cast Irion embellishments. The Pole shalll have a tapered construction with the aesthetically fluted design and with embellishments at appropriate points throughout the pole which runs the inner pipe of Ø76.1mm and Ø60.3mm from the base plate. The base plate of the of the pole shall be of MS 200 mm x 200mm, 12mm thick with and shall be facilitated with elongated slots to suit the 300mm, J-type, M16 bolts that shall be provided with suitable nuts and plain washers. The cable entry provided at the base plate shall be Ø70mm. All pole sections are welded using special v groove technique by certified welders using high end MIG welding process. The surface finish of the pole shall be epoxy zinc phosphate primer followed by the environmentally stable Polyurethane based paint. Luminaire Dimensions (mm) (Tolerance ± 10%) 2.9 mtr Decorative Pole See Attached Reference Image.
Single piece with circular shaped plant made of die cast aluminum using pressure die-casting process,with a decorative pineapple which is also made of die cast aluminum using pressure die-casting process, fixed on the top.Auxiliary and optical compartment can be accessed by tilting the top frame.Bottom frame in single piece, made of die cast aluminum using pressure die-casting process witha three curved uprights decorated which is also made of die cast aluminum using pressure die-casting process, fixed at the bottom with a hole (28 mm) for fixing to support.Frosted Screen made of polymethylmethacrylate (PMMA)molded in a single piece using Injection molding process. Screen's Impact resistance: IK06. Pure polyester powder coating in the same color as of the pole/as per the lighting consultant.Optical Compartment IP Rating - IP 66.Height – 700mm,Dia. - 470mm, Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 4kv(an additional surge protection device of 10kV also provided in-built the fixture). Modular (2 X 2) refractive lens in PMMA with Type-II/III/IV photometric distribution options. protection screen in extra-clear tempered glass with impact resistance IK 08.LM80 Luminaire Dimensions (mm) (Tolerance ± 10%) Postop IP Rating 66 IK Rating IK06 & 08 Lumen (Tolerance ± 10%) 5000 Optics (Degree) (Tolerance ± 10%) Symmetrical Max Power Consumption (W) 71 CCT (Kelvin) 3000 Driver Integral See Attached Reference Image.
Single piece with circular shaped plant made of die cast aluminum using pressure die-casting process,with a decorative pineapple which is also made of die cast aluminum using pressure die-casting process, fixed on the top.Auxiliary and optical compartment can be accessed by tilting the top frame.Bottom frame in single piece, made of die cast aluminum using pressure die-casting process witha three curved uprights decorated which is also made of die cast aluminum using pressure die-casting process, fixed at the bottom with a hole (28 mm) for fixing to support.Frosted Screen made of polymethylmethacrylate (PMMA)molded in a single piece using Injection molding process. Screen's Impact resistance: IK06. Pure polyester powder coating in the same color as of the pole/as per the lighting consultant.Optical Compartment IP Rating - IP 66.Height – 700mm,Dia. - 470mm, Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 4kv(an additional surge protection device of 10kV also provided in-built the fixture). Modular (2 X 2) refractive lens in PMMA with Type-II/III/IV photometric distribution options. protection screen in extra-clear tempered glass with impact resistance IK 08.LM80 Luminaire Dimensions (mm) (Tolerance ± 10%) Postop IP Rating 66 IK Rating IK06 & 08 Lumen (Tolerance ± 10%) 2000 Optics (Degree) (Tolerance ± 10%) Symmetrical Max Power Consumption (W) 29 CCT (Kelvin) 3000 Driver Integral See Attached Reference Image.
The job includes supply and installation of 4 nos laser LED projectors with the following specifications : Supply, Installation, testing, commissioning and Programing of DLP laser Projector for outdoor application as per following specfication:- Light output:- 17000 lumens, resolution:- WUXGA (1920X1200), Native Aspect Ratio 16:10, Contrast Ratio 500000:1. light source:- laser phosphor, illumination life:- 20000 hours minimum, horizontal - vertical lens adjustments:- motorized , inputs:- HDMI/DVI, HDBaset 1x RJ45 Controls:- 1x RS232, ethernet ,Accessories with complete with mounting and long throw lens. Item to include all material and labour complete as per specifications and to the entire satisfaction of Project Manager. AND all peripheral hardware equiepement and software required for outdoor installation, running media of choice (atleast 7 sets of content of minutes each) the same shall be created by the contractor and gotten approved from the consultant and the department before final installation. The projectors shall be installed in suitable outdoor canopies (the installation scheme shall have to be approved by the consultant and the enginner incharge). The server and other media equiepemnt shall be supplied and installed at the space alotted. This job includes supply, installation, testing, commissioning & successfull O&M for 3 years complete in all respects. Luminaire Dimensions (mm) (Tolerance ± 10%) Projection Mapping IP Rating Martyrs Column IK Rating Martyrs Column Lumen (Tolerance ± 10%) Martyrs Column Optics (Degree) (Tolerance ± 10%) Martyrs Column Max Power Consumption (W) Martyrs Column CCT (Kelvin) Martyrs Column Driver Martyrs Column
Amountof AMC for a periode of 3 years after completion of 3 years of defect liability period or performance guarantee period including cost of all materials labour charges etc. complete to make the façade illumination system functional in all respects.
a) For the first Year
b) For the Second Year
c) For the Third Year
Lighting Technologies India Private Limited
Swadeshi Civil Infrastructure Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .