Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹6.8 L+₹72,283 (11.8%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹7.8 L+₹1.7 L (28.0%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
28 Apr 2022, 6:00 pmClosed
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
REPAIR/MAINTENANCE OF TRANSFORMERS AND ROUTINE MAINTENANCE OF DG SETS AND LT PANELS AT VARIOUS LOCATIONS AT 1 AFSB DEHRADUN UNDER GE (AF) SARSAWA
2022_MES_512772_2
8121/SAR-70/E8 REPAIR/MAINTENANCE OF TRANSFORMERS
Open Tender
Civil Works
Item Rate
183 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹16,000
Yes
31 May 2022
13 Apr 2022
30 Apr 2022
13 Apr 2022
28 Apr 2022
14 Apr 2022
13 Apr 2022 - 14 Apr 2022
Amount
M&L for Excavation in trenches in soft/loose soil n.exc 1.5mtr deep and n excl 1.5 mtr wide for laying of cables, pole, etc and gettting out including of dressing / trimming sides and levelling, grading and ramming of bottom excavation complete all as specified and as directed.
Returning filling in including spreading, leveling watering and well ramming in layers not exc 25 cm thick each layer in soft/loose soil complete all as specified and as directed.
Removing excavated materials (soils) not exc. 50 m and depositing where directed at a level not exc.1.5 mtr above the starting point complete all as specified and as directed.
M & L for fine dry sand cushioning for underground cable by providing a layers of sand 8 cm deep before laying and 15 cm deep after laying the cable including streching the cable complete al as specified and as directed.
M & L forlaying of bricks sub class 'B' old size laid flat perpendicular to the direction of cables for protection complete all as specified and as directed.
Supply, laying in repair UG cable XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm, 2.0 core stranded conductor and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply, laying in repair UG cable XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm, 2.0 core stranded conductor and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply, laying in repair UG cable XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 sqmm, 3.5 core stranded conductor and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply, laying in repair UG cable XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 70 sqmm, 3.5 core stranded conductor and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Supply, laying in repair UG cable XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 95 sqmm, 3.5 core stranded conductor and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
Taking down old unsesrviceable digital timer of any make and capacity from existing panel and supply and fix new digital time switch programmable evry 1 minute, with backup of 6 years, 28 memory locations, current carrying capacity up to 16 Amps, weekly programmable with 1 change over complete all as specified and directed
M & L spray for painting and numbering of electric poles including street light brackets, cross arms, GOD system, four pole structure,two pole structure, LT panels from out side with two coats of aluminium duco paint after cleaning and preparing the surface of poles of any size complete all as specified and as directed by Eng-in-chaarge.
M&L for carrying out the servicing of DG set of capacity 15 KVA to 200 KVA, Make - Kirloskar at 1 AFSB by taking down old/UNSV spare parts, drain out burnt engine oil and cleaning the oil chamber by cleaning solution, Cleaning and servicing of radiator from inside and outside thoroughly with cleaning solution K-Clean, including replacement of ,spare parts checking/rectify all the electrical connection and tightening of loose nut & bolts including carrying out minor addition/alternation for fixing the parts for smooth functioning of DG Sets complete up to entire satisfaction of Engr-in-charge. Note : Servicing of DG set shall be carried out by authorised service dealer of Kirloskar and supply of spare parts shall be measured and paid separately under relevent items.
-ditto- as above item No 13 but Supply only spin on filter for lubricating oil cat part no. 06.436.01.0.00
-ditto- as above item No 13 but Supply only primary element cat part no. 3H.132.01.0.00
-ditto- as above item No 13 but Supply only secondary element cat part no. 3H.132.02.0.00
-ditto- as above item No 13 but Supply only V fan belt for alternator of capacity 15 to 200 KVA DG Set
-ditto- as above item No 13 but Supply only of primary and secondary air filter suitable for 15 to 200 KVA DG Set.
-ditto- as above item No 13 but Supply and replacement of primary fuel filter of generatior 15 KVA to 200 KVA
-ditto- as above item No 13 but Supply and replacment of oil filter of generator 15 KVA to 200 KVA
Supply and fixing indication lamp R,Y,B complete set,complete all as specefied and as directed..
S&F oil sump gasket set suitable for 15 to 200 kva DG Set complete all as specefied and as directed.
Supply and fix in repair radiator hose set with clips complete all as specified and directed.
Taking down old unsericeable water pump assembly and supply, install and testing new water pump assembly for DG set of capacity upto 200 KVA complete all as specified and directed.
Materila and labour for taking down old unserviceable/wornout flywheel and supply and fix in repair new flywheel of DG set of cpacity upto 200 KVA complete all as specified and directed.
S & F contact element NO cat pt RB2-BE-101 Make - C&S/ L&T / Seimens
Supply only K oil super 15 W 40 suitable for kirloskar DG Set.
Supply only K cool Super plus 50-50 premix cat part no.82.020.35.1.25
Taking down old unserviceable AVR unit from DG set of various capacity and Supply, installation, testing and commissioning in replcement of AVR unit suitable for 3 phase 50 Hz alternator of capacity upto 200 KVA DG set completer all as specified and directed.
Taking down old unserviceable voltage surge protector relay from existing AMF panel of capacity upto 200 KVA DG set and supply and fix new voltage surge preotection relay complete all as specified and diected.
Taking down old unsserviceable single phase preventer of any make and capacity and supply and fix in replacement single pahaase prevventer complete all as specified and directed.
Material and labour for servicing and winding of alternator 12/24 Volts including replacement of minor parts and testing of DG set of any capacity complete all as specified and directed.
Mateial and labour for taking down unserviceable turbo charger from DG set of any capacity carrrying out necesaray repairs and replacing requird minor/major parts and fixing in its original position and testing on completition complete all as specified and diercted.
Disconecting HT/LT cable and Earthing connections of burnt/defective transformers of capacity upto 315 KVA , 11 kv/433 volts 3 phase from pole/floor mounted, taking down from site of installation carefully with the help of crane and transportation of the same to workshop for repairs, draining out the transformer oil, dismantling complete and taking out the core assembly and removing brunt out windings, dehydrating the core assembly, reassembling transformer after repair, filtred/ dehydrated, topping up new with new oil, carrying out routine tests, including transportation back to site, testing full load after making cable and earthing connections complete all as specified & as directed. (Note :- New transformer oil, Dehydration of transformer oil shall be measured and paid separately.)
Supply and fixing in replacement 433 volt procelain bushing insulators for LT side of out door/ indoor type transformer of capacity capacity upto 315 KVA complete all as specified and as directed
Supply and fixing in replacement 11 KV procelain bushing insulators for HT side of out door/ indoor type transformer of capacity capacity upto 315 KVA complete all as specified and as directed
Supply and fixing in replacement of worn out LT bush assembly made out of brass with heavy duty brass complete with brass spindle, nuts, bolts, washers etc without bushing insulators all as per existing size, shape and length, suitable for capacity upto 315 KVA capacity transformers complete all as specified and as directed
Supply and fixing in replacement of worn out HT bush assembly made out of brass with heavy duty brass complete with brass spindle, nuts, bolts, washers etc without bushing insulators all as per existing size, shape and length, suitable for capacity upto 315 KVA capacity transformers complete all as specified and as directed
Supply and fixing cork sheet gasket, 6 mm thick, superior quality, on top cover plate of the transformer 50 to 630 KVA after taking down/out gasket as existing at site complete all as specified and as directed.
M&L for rewinding of LT winding with copper strip of suitable size/gauge, fixing the coil in the position in core assembly and making connection as per original pattern including providing insulation, complete all as specified and as directed.
M&L for rewinding of HT side coil with super enameled copper wire of suitable size/gauge, fixing the coil in the position in core assembly and making connection as per original pattern including providing insulation, complete all as specified and as directed.
Supply and fixing in replacement Tap changer switch suitable for suitable for Transformer upto capacity 315 KVA complete all as specified and as directed.
Supply and filling of transformer oil for transformers installed at various site for topping up after dehydration to achieve the dielectric strength 60 KV at 4 mm gap complete as per IS 335-1993 complete all as specified and directed.Make :Power link, Svita Power Oil (Oil be brought in company sealed drum at site).
Disconnecting and taking out the voltage stabilizer of following capacity upto 250 KVA any description and of any make, dismantling / opening of the voltage stabilizer of following capacity, three phase, AC 415 Volts, for Maintenance and servicing mechanically and electrically,including draining out existing transformer oil, and cleaning, oiling /greasing, removing & replacement of defective / unserviceable parts with new parts, as required at site and manufacturer's instructions and checking electronic circuits to make it functional , reassembling the parts of voltage stabilizer after overhauling / servicing at position ensuring proper out put connecting to existing system and applying one coat of synthetic enameled paint (heat resistant type) by spray machine after preparation including writing MES No/ SM No in capital letters of suitable size on body of stabilizer and making voltage stabilizer perfectly operational and testing at site on existing connected load to the entire satisfaction of the Engineer-in-Charge complete all as specified and directed. (including mentioned in Note here in below) Notes :-(i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch ‘A’ as supply only but fixing charges of the parts replaced/repaired is deemed to be included in these item. (ii) Oil shall be drained out and collected in contractors own containers and reuse after heating and filtration through filtration plant to achieve the suitable dielectric strength/insulation value. Refilling, heating and filteration shall be included in the rate quoted by the contractor for above items. (iii) Fresh oil required for top up shall be measured as “supply only” but its heating and filling shall be included in the rate quoted by the contractor for above items. (iv) The quoted rate shall be deemed to include replacement of small/ minor parts i.e. washers,nut bolts, packing, screws,lamp etc. "
Servo motor 10 Kg-cm capacity.
Complete control wiring for each phase.
RC Net Work 10 Kg-cm (Resistor- Capacitor network)
Volt meter 0-440 volts, as existing type
VARIAC Coil 150 KVA capacity per Phase
Taking down old burnt/unserviceable PCB/PLB card from voltage stabilizer upto capacity 200 KVA and supply,fix, testing and commission new PCBPLB compitable as existing complete all as specified and directed.
M & L for Cleaning of fuel tank of DG sets any capacity by collecting the fuel in cleaned barrels and removing sludge deposited/accumulated inside the tank of and disposal of sludge at a distance not exceeding 100 metre and cleaning the tank with kerosene oil , replacement of fuel tank strainer and unserviceable fuel gauge with new PVC fuel level indicator fixed with clips to the tank and marking levels for every 10 litre by marking and numbering on the side of fuel tank with synthetic enameled paint and refilling the collected fuel after filtration complete all as specified and directed.
Supply and fix air termination, single pointed copper rod 12mm dia 300mm long on 40 mm dia GI pipe (medium grade) 1.05 mtrs lenth duly fixed/secured with PCC or with GI wire support, commplete all as specified and directed.(Note: Maetrilas required for PCC or GI wire support deemed to be inclusive in the quoted rate.)
Supply and fix in lrepair Aluminium strip 25x3.15 mm on procelain base insulator of suitable size with saddles and fixing screws etc for roof conductors or down conductors above ground complete all as specified and directed.
Taking down old unserviceable motor from voltage stabilizer upto capacity 200 KVA and suppply and fix new single phase,50 Hz single phase motor compitable with existing system complete all as specified and directed.
Supply, installation, commissioning and testing of Advance Manitenance Free environment friendly ring earthing system. Each set consisting of 3 Nos of 6 feet length, 17 mm dia earth electrode made of high tensile low carbon steel circular rods, molecularly bonded cooper on outer surface ( minimum copper bonding thickness - 250 microns) with terminals to connect incoming strip with 3 bags (25 Kg each ) of environment friendly backfill compound as per manufacturing instructions with ROHs test certificate for each 150 x 25 x 6 mm Copper Bar with 4 hole shall be exothermically welded ontop to copper bonded rod to make terminal laid in minimum 80 mm dia bore. Manufacturer name shall be embossed on rod. 25 x 3 mm copper shall be used to interconnected the earths and to make the ring. The earth pit cover polypropeline (300 mm x 300 mm) shall be included in the scope of work. Make: OBO/JEF ECO SAFE/ENNOV Note: (i) Earthing shall be tested after completion of work by contractor in presence of Engr-in-Charge and proper record shall be maintained duly signed by all concerned. On testing if the desired earth resistance of less than 1.0 Ohm is not obtained the earthing will be redone at no extra cost to Govt. (ii) The cooper strip from test point to euipment or entire earting system to Eqpt/bldg only shall be measured and paid under relevant item.
M/s Subhash Chand Saraswat
M/S PRABHUKESHVAM (OPC) PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .