| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.4 LAccepted-AOC KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.6 L+₹19,926.40 (0.68%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹29.8 L+₹31,193.40 (1.06%)Rejected-AOC CHATHANATTU HOUSE XXIII 362B 1 AYYANKALI ROAD EDAKOCHI KOCHI 682 010 | KOCHI | ERNAKULAM | KERALA | 682010 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹32.5 L+₹3.1 L (10.4%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹34.0 L+₹4.6 L (15.5%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
14 Jan 2023, 6:00 pmClosed
DC SHARMA IDSE
CWE (NW) KOCHI
PROVISION OF INTERLOCKING TILES IN CERTAIN HOUSES OF 500 AND 300 SERIES AT KATARIBAGH AND ADDN/ALTN TO COMMAND IW OFFICE (3rd FLOOR), ASHOKA BUILDING AT NAVAL BASE, KOCHI
2022_MES_569643_1
CWE(NW)/KOCHI/81333
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (NW) KOCHI
₹66,000
Yes
28 Jan 2023
16 Dec 2022
16 Jan 2023
16 Dec 2022
14 Jan 2023
31 Dec 2022
Amount
Surface dressing n.exc 15 cm deep in soft/losse soil including removal of materials obtained outside MD land complete all as specified and as directed .
100mm loose thick hard core of gauge n exc 63mm,deposited,spread and levelled in layers n exc.15 cm thick,watered and rolled/rammed to a true surface complete all as specified and as directed .
M&L for 75mm thick cement concrete type D2, 1:4:8 (40 mm graded aggregate) as in sub base complete all as specified and as directed .
M&L Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm Spreading and levelling and ramming as specified complete all as specified and as directed .
M/L Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, with grey cement and pigment complete all as specified and as directed .
M&L for PCC type B-0, 1:2:4 (12.5 mm graded aggregate) as in mass concrete around the Machine pressed precast conctete paver block or chamfered on edges all as specified and as directed .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts,wells,cesspits,manholes,pier holes,etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft soil complete all as specified and as directed.
Returning/filling in layers and ramming in layers around pile cap,plinth beam etc using excavated soil incl sprading,levelling,well ramming in layers not less than 25cm thick complete all as specified and as directed.
Removing excavated material exc 1.5Km n.exc 5Km and depositing where directed at a level n.exc 1.5m above starting point complete all as specifed and as directed.
M&L PCC 1:4:8 type 'D-2' (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specifed and as directed.
M& L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, Type C1, 1:3:6 (using 20mm graded stone aggregate), complete all as specified and as directed .
Material and labour for plain cement concrete C1 mix 1:3:6 using 20mm graded aggregate in coping bed block etc including weathering slightly rounded of chamfered angles and throating complete all as specifed and as directed.
Material and labour for rendering 10 mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specifed and as directed.
M & L preparation of new plastered surfaces and applying two coat of cement base paint over a coat of primer on wall complete all as specifed and as directed.
Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards/slabs/blankets any thickness including framework cover fillets etc complete all as specifed and as directed.
Supply and fixing suspended false ceiling consiting of 12mm thick gypsum seamless board suspended on GI frame work with staggered joints,GI frame work to consist GI perimeter channel 25mmx20mm of 22 gauge along perimeter of false ceiling.Channel section of 50x25mm of 22 gauge and at 300mmc/c throughout one way fixed with screw/nut boltand other direction 40X15mmx22 gauge channel provided for interlocking with GI cleat and expansion fastners including hangers 6mm dia GI fixed to roof truss boards are to be joined and finished so as to have a flush look which included finishing the tapered and square edges of the gypsum board with joining compound paper tape and two coat of oil bound distemper over one coat of primer& one layer 1.5mm thick putty suitable for gypsum board including necessary scaffolding and shuttering complete all as specified and as directed.
Taking down carefully copper /aluminium point wiring (light/fan/socket) complete (fittings such as switches.socket outlet etc to be measured seperately) removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls,floors etc complete all as specified and as directed.
M&L for concealed point wiring with 1.5 Sqmm PVC insulated un sheathed multistranded single core copper conductor FRLS ISI marked cable through rigid non metallic ISI marked PVC concealed conduit with including all accesories,suitable white cover plate with frame & modular metal flush box and 1.5 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS ISI marked cable as earth continuity conductor including cutting and making good, the disturbed surface complete all as specified and as directed. (a) One light point controlled by one switch Notes:- (i) Rate quoted shall be deemed to be inclusive of providing modular boxes,modular plates suitable for fixing sockets and switches. (ii) Switch, socket and regulator shall be measured and paid seperately.
All as per item No. 18 above but for One fan point controlled by one switch complete all as specifed and as directed.
All as per item No.18 above but for One 5 pin 5 Amps socket point controlled by one switch on independent board complete all as specifed and as directed.
All as per item No. 18 above but with 2.5 Sqmm copper conductor including 2.5 Sqmm copper cable as earth wire for one 6 Pin 16 Amps Socket outlet on independent board complete all as specifed and as directed.
S&F modular switch 1 way 6 Amps, I module complete all as specified and as directed.
S&F ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and as directed.
S&F Modular socket 6 Amps and 2/3 pin 2 module complete all as specified and as directed.
S&F Modular socket 6 A/ 16 A - 2/3 pin 2 module complete all as specified and as directed.
S&F switch 15 A one way SP modular type complete all as specified and as directed.
Supply and fix LED flat panel with high brightness with glare free recessed 2 feet by 2 feet 36 Watt 4000k luminaire efficiency 120Lumen/Watt fitting including all connection all as specified and directed. Make Philips Cat Part No. RC380BLED36S-6500G4L60W60PSUOD or equivalent make in list of manufactures.
S&F sheet metal enclosure Vertical TPN for DBs's when MCB's to be used 4 way with 200 amps bus bar double door IP 43 glazed door complete all as specified and directed. Make L&T Cat Part No. DBVTL004GD or equivalent make in list of manufactures.
S&F MCB 'B' curve 63 Amps, 4 pole, 415 volts,10KA complete all as specified and as directed. Make L&T Cat Part No. BB40630B or equivalent make in list of manufactures.
S&F SPN sheet metal enclosure for DB 8 ways double door complete all as specified and as directed.
S&F MCB 'B' Curve 6-32 Amps SPN, 240 Volts,10KA complete all as specified and as directed. Make : L&T Cat Part No. BB20060B to BB20320B or equivalent make in list of manufactures.
S&F MCB 'B' curve SP 6 to 32 Amps, 240 Volts,10KA complete all as specified and as directed. Make : L&T Cat Part No. BB10060B to BB10320B or equivalent make in list of manufactures.
S&F energy efficient ceiling fan of 1200 mm sweep (5 star rated) 230 volt, 50 Hz, including all electrical connection all as specified and as directed. Make : Havells Cat Part No. ES-40 or Crompton Cat Part No. Maximus (5 star rated) or equivalent make in list of manufactures. Note : Old ceiling fans to be deposited with MES store yard.
Taking down unserviceable sub main wiring of any size complete all as specified and as directed.
M&L submain wiring with 4 single core 16 Sqmm PVC insulated unsheathed multistranded copper conductor cable1100 volt grafe drawn through and including suitable PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete excpet beam and RCC roof and one run of 16 Sqmm PVC insulated unsheathed single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed. Note : 4 runs of 16 Sqmm size PVC cable, 1 runs of 16 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for earthing complete with galvanised steel earth plate elctrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.point 3 including earthing pit PCC (1:3:6) type C1 RCC precast (1:2:4) type B1 cover slab of 100mm thick using 8mm dia TMT bars @100mm c/c as reinforcement 40mm dia GI protection pipe and 20mm dia GI pipe of medium grade for watering pipe ,wire mesh,funnel and providing charcoal or coke and salt in alternative layers connected to earthing test point all as specified or indicated including testing on completion.
Taking down old unserviceable earthing of any size complete all as specified and as directed.
M&L for galvanised iron strip of size 25X4mm as earth continuity or main earthing lead fixed to wall on battern/recess/chases/buries in ground or drawn in conduit/pipe/fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and as directed.
Supply,installation testing and commissioning of split air conditioning unit 1.5TR capacity inverter type complete with cordless remote control latest model minimum 5 star labelled eco friendly refrigerent gas 45000Kcal/Hr,50Hz,240V air cooled copper condenser with all accessories varied speed including fixing the outdoor unit with suitable stand as site requirement and fixing of room (high wall) unit on wall with necessary wall cutting/making holes to pass the refrigerent pipes (core cutting),drain pipes cables etc and making good to match with existing finishing complete providing and making interconnection including suction and discharge copper pipes with refrigerent including with nitrile rubber insulation and control cable from indoor to outdoor as required at site,power cabling from isolator/enclosure to unit first charging of refrigerent gas drain piping of suitable size including connection drain lines from unit to nearest drain points complete all as specified and as directed.
Supply and fix 4KVA capacity voltage stabilizer copper wounded suitable for 1.5 TR inverter type split AC automatic operation,single phase naturally air cooled indoor type & designed for input variation between 130V to 300V with output voltage stabilized at 230V with accuracy of +2.5% and speed of correction 8 volts per second fixed on wall with necessary arrangement complete all as specified and as directed.
Taking down old DBs of any size complete all as specified and as directed.
M & L for sub main wiring with 2 runs of 4 Sqmm PVC insulated FRLS multi stranded copper conductor cable including suitable size PVC conduit with one run of 4 Sqmm PVC insulated FRLS cable as earth continuity wire complete all as specified and as directed. Note: Three runs of 4Sqmm cable, and one run of PVC conduit shall be measured as one length.
Supply and fixing copper refrigerant piping of both sizes for suction line 5/8" and 1/4" for discharge including thermal insulation class "o" nitrile rubber insulation density 45- 55 kg/m³, for suction/ discharge line, beyond standard length provided with original units by the manufacturer complete all as specified and as directed.
S&F single pole enclosure with a 2 pin and earth plug and socket complete with one single pole MCB 20 Amp 240 Volt complete all as specified and as directed.
S&F MCB SP 240V at 10 KA 'C' Curve of 6-32 Amps complete all as specified and as directed.
S & F 20 mm dia CPVC pipes, SDR-13.5 & plain CPVC SDR 11 fittings, fixed on wall/ceiling with all necessay fittings, solvents complete all as specified and as directed.
K THOMAS AND COMPANY
ANIE JOHN CONTRACTORS
JOBOSTRUCTURALS
LALA CONSTRUCTION
REIGN CONSTRUCTIONS
MS BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .