Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 800 RAM NAGAR ROORKEE DISTT HARIDWAR UK PIN 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹17.2 L Quoted ₹17.8 L | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER |
| 2 | L2₹19.3 L+₹1.6 L (8.80%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹19.3 L+₹1.6 L (8.80%) | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 3 | L3₹22.3 L+₹4.5 L (25.4%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹22.3 L+₹4.5 L (25.4%) | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
| 4 | L4₹23.6 L+₹5.8 L (32.8%)Rejected-AOC | ₹23.6 L+₹5.8 L (32.8%) | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
5 Jun 2025, 6:00 pmClosed
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
REPAIR/ REPLACEMENT OF ROOF TREATMENT WORK, ALUMINIUM WORK MISC FITTINGS, PVC FLOORING, FLOOR/WALL TILLING AND CERTAIN B/R WORKS OF TECHNICAL AND RESIDENTIAL AREA OF DEAL UNDER GE (I) RND DEHRADUN
2025_MES_706024_2
GE(I)RND/9470/E8/25-26
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Class Any Class Category a (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 and 1.5 of section of Part I of MES Manual on contracts-2020 as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I RND DEHRADUN
₹50,000
Yes
9 Jul 2025
15 May 2025
7 Jun 2025
15 May 2025
5 Jun 2025
22 May 2025
15 May 2025 - 22 May 2025
Amount
M&L for Brick work with sub class B bricks, straight or curved on plan exceeding 6m mean radious built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L75mm thick PCC 1:3:6, type C2, using 40mm graded stone aggregates as in Plinth protection, platform and floor surface finished even & smooth without using extra cement complete all as specified and directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in sub base of floors complete all as specified and directed.
M&L Plain cement concrete 1:5:10 type E-2 (using 40mm graded stone aggregate as in foundation filling & Mass concrete , sub base.complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in lintels upto 1.5 clear span , cills steps seismic and other similar bands, copings, hold fast and the like incluing weathering , slightly rounded or chamfered angles and throating asdirected with and icluding necessary form work in CM 1:4 complete all as specified and directed.
M&L for RCC(1:2:4) type B-1using 20 mm graded stone aggregate as in slab supported on walls, beams, and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M& L for Mild steel TMT bars 8 mm dia and over cut to length, bent to shape required, including cranking, bending spi-rally for hooping for col-umns, hooking ends and binding with and in-cluding mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for taking down/dismantling of existing roof treatment / cement plaster of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc terracing including screed bed etc. Hessian base felt/tar felt etc. (any type and thickness) with and including, removing debris out sideMOD Land at contractor is own arrangement ) complete all as specified & directed.
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys , scrubing down with water etc, complete all as specified and directed.
M&L for Rendering 15 mm thick on fair faces of concrete/brick surfaces in cement mortar 1:4 mixed with water proofing compound as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed. Note :- WPC shall be measured and paid for seprately as "supply only" under respective item of sch A/ BOQ.
M & L for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement) complete all as specified and directed.
M & L for 10 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling in cement mortar 1:3 finished even and smooth (without using extra cement) complete all as specified and directed.
Material and labour for 50mm thk (average) PCC 1:2:4 type B-1 using 20mm graded stone agg as in roof padding finished even and smooth without using extra cement all as specified and directed .
Supply only Liquid water proofing compound ISI Marked (used 200 ml per bag of cement) complete all as specified and directed.
M&L for water proofing treatment with A coat of cold applied bituminous primer over cleaned surface @ 0.30 Kg/Sqm and applying one coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm followed by APP modified five layer polymeric membrane 3mm thick, minimum weight 3.60 kg/sqm reinforced with polyester non-woven fabric (weighing not less than 150 gms/sqm) manufactured by authorised manufacturer specified in particular spicification, laid as per the manufacturer instruction with side over lap of 75mm & end over lap of 100mm & tucked into the chases on vertical surfaces and applying one coat of hot blown bitumen 85/25 grade @ 1.20 Kg/Sqm finally finished with bituminous aluminum paint @ 0.20 Kg/Sqm complete all as specified & directed. Note:- The work shall be executed through authorised applicator approved by GE.
M&L for cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
M&L for bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed.
M & L for preparation of newly plastered surface and applying of Birla/JK white wall putty approx 1 mm thick in two layer as per manufacturer's instruction on newly prepared surface and make the surface smooth by rubbing with sand papers etcand applying two coat of oil emulsion distemper over a coat of primer complete all as specified and directed.
Prepration of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed.
M&L for non skid ceramic coloured jont free tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with over and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete complete all as specified and directed.
Srl item No. 21 above but on vertical surfaces such as skirting over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tilesg all as specified and directed.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0..06 Sqm but not exceeding 0..11 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with over and includingg laying of 15 mm thick screed bed or bedding layer in CM 1:6complete and rubbish off the premises complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300 mm x 450 mm x 7mm / 350 mm x 450 mm x 7mm / 250 mm x 250 mm x 7mm thick as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match with over and including 10 mm thick rendering in cement mortar 1:4 finished rough surface to receive tiles complete all as specified and directed.
Virified Ceramic tiles 10 mm thick light shade (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed inwhite or colour cement to match over and including 15 mm thick screed bed in CM 1:6 with and complete all as specified and directed.
Srl item No 25 above but on vertical surfaces such as skirting over and including 10mm thick rendering in cement mortar 1:4 rough finish to receive the tiles with complete all as specified and directed.
M&L for Granite slab of 16 to 18 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and incl Demolition of stone slab and tiles laid bedded and pointed in any mortor of any description or thickness in floor complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick laid & jointed with grey cement slurry mixed with pigment to match the shade of slab incl rubbing & polishing over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Preparation of new plaster surfaces of wall and applying two coats of cement base paint etc complete all as specifed and directed.
Taking down chowkats or frames with shutter (without taking off shutters from the frame) n. exc. 1.50 sqm each including removing to store complete all as specified and directed.
Taking down Chowkats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n. exc. 4.00 sqm each including removing to store complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
S & FPVC (SWR) pipes 75 mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F PVC (SWR) pipes 110 mm bore, single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F PVC (SWR) bends any radius, with access door, for 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) bends any radius, with access door, for 110 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) junction, with access door, single (single T) equal or unequal, for 75 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) junction, with access door, single (single T) equal or unequal, for 110 mm bore of pipe complete all as specified and directed.
S & F PVC (SWR) reducers 110 mm bore complete all as specified and directed.
S & F PVC (SWR) vent cowl bore of 110 mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius of bore 75 mm bore complete all as specified and directed.
S & F PVC (SWR) bends any radius of bore 110 mm bore complete all as specified and directed.
S&F in repairs mortice lock, vertical type of size 100 mm with brass body 4 lever complete all as specified.
S&F powder coating anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coating anodised aluminium door shutters, aluminium section weighing not less then 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed.
S&F powder coating anodised aluminium window and ventilator shutters, side hung type without sash, aluminium sections weighing not less then 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing , anodised aluminium snap, rubber packing , anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (2 No) suitable handle (1 No) complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 200mm long and fixed complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed complete all as specified and directed.
S&F 300mm length, aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
M&L for 5.5 mm thick sheet glass ordinary quality in panes exc 0.50 sqm each fixed with & including rubber gasket in aluminium frame work complete all as specified and directed.
S&F in repair for 3.20mm thick Linoleum, plain coloured, laid dry in floors including stretching, cutting and fittinge complete all as specified and directed
S&F mild steel tubular work as in Joist,channel,angle, or tee sections, fixed independently,without connecting plates, etc. ( cut to ordinary lengths i.e within 20 mm of the length indicated , conforming to gde Fe 410-W (Gde E-250) Quality complete all as specified and directed
M&L for mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F mild steel work as in bands,strap, supports or stay for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasp and staples, chains hand made sliding bolts, clamps, hold fasts, wallties hook for hanging fans,plain angle cleats for secruing purlins to wood trusses or rafters, knee piece inserts, two way and tree ways straps , plate washers and similar samllarticles confirming to Fe 290 or E-165 complete all as specified and directed
M&L for Pre-painted galvatume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa it shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm /sqm of coating (total both surfaces) as in roof covering /cladding to wall, fixed with self tapping screws neeoprene and EPDM washers complete all as specified and directed.
M&L for Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa it shall be coated with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm /sqm of coating (total both surfaces) as in roof covering /cladding to wall, fixed with self tapping screws neeoprene and EPDM washers complete all as specified and directed.
S&F in repair venetian blind coloured powder coated 35mm wide and 1 mm thick Aluminium alloy blades with opening and closing arrangment including aluminium hanging channel at top with sliding wheel/ring including pulling rope in both side and necessary accessories complete all as specified and directed.
Providing & fixing false ceiling at all heights with perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter- locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge.
Providing and fixing 12 mm thick prelaminated particle board with decorative laminatiion on both sides flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise described and removal of dismantling materials with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15cm thickness (above or below ground floors) with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles and with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Taking down Cast iron/PVC pipe of any dia and size fixed on wall or floor including all fittings and removing of debrish to with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Demolition of ( reinforced cement concrete) (reinforcement cut as required to facilitiate demolition) of any description and in any positionnot otherwise specifically provided for and removal of demolished materials to a distance exceeding 500 M but not exceeding 1000mtr, complete all as specified and directed.
Dismantling of wall and ceiling boards any thickness including cover filletes with and including with and including removing Debris out sideMOD Land at contractor is own arrangement complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness complete all as specified and as directed. Notes for item No. 1 to 67:- (i) The work will be carried out upto 8th storey bldgs. Hence necessary complete scaffolding and other safety arrangements will be managed and made by tenderer/ Contractor accordingly at own expense. (ii) Tenderer kind attention is also invited to srl clause 1.16 of Sec-I on srl page No 1 to 67 (General rules for Safety in Construction) as specified in SSR Pt-I (2009) for safety measures/ precautions. (iii) Steel scaffolfing is to be used in the work. (iv) Necessary arrangement for temporary plug the / door / window / ventilator opening at time of taking down plaster/ new plaster till completion of work. Made by Tender / Contractor at own expense.
M/S Anil kumar (BID ID -3313001)
JS CONSTRUCTION COMPANY (BID ID -3313675)
PANTECH INSTRUMENTS AND SERVICES (BID ID -3310436)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .