Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹38.4 LAccepted-AOC | L-1 | Accepted-AOC AS CWC-II DECISION HELD ON 21/09/2023 | |
| 2 | L-2₹39.3 L+₹92,065 (2.40%)Rejected-AOC | L-2 | Rejected-AOC AS CWC-II DECISION HELD ON 21/09/2023 | |
| 3 | Rejected-Technical S 5 JALANDHAR BYE PASS ROAD PATHANKOT PATHANKOT PATHANKOT PATHANKOT PUNJAB 145001 UDYAM PB 16 0002469 | PATHANKOT | PUNJAB | 145001 | - | Rejected-Technical AS PER CWC II DECISION HELD ON 05/09/2023 |
Tender Value
₹38.7 L
EMD Value
₹77,500
Closing Date
25 Aug 2023, 2:45 pmClosed
GENERAL MANAGER
O.F.BHANDARA
Provision of electrification work in plant house utility bldg for RK-101 and RK-102 inside factory at O. F. Bhandara.
2023_MIL_164863_1
No.EO/51/ND2323/BF
Open Tender
Electrical Works
Item Rate
60 days
O.F.Bhandara
As per Tender Documents.
8 documents required · 8 mandatory
₹0
₹77,500
Yes
22 Sept 2023
18 Aug 2023
28 Aug 2023
18 Aug 2023
25 Aug 2023
18 Aug 2023
Amount
Rough excavation in hard dense soil in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out.
Rough excavation in Mud in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out.
Excavating in trenches in hard dense soil for each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out for earth pits.
Back filling of excavated soil spreading, levelling, watering & well ramming in layers.
M & L fine sand filling in the trench for cushioning of cable /Substation trench filling.
Supply & fixing of of Cast Iron Frame and Cover for earth pits in FG 150 grade of material.
S&F including fabrication work of Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc.
S & F for rolled mild steel in plates (plain or chequered),channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment over cable trench , of quality GDE Fe 410-W (Gde-E-250)quality-B complete all as specified , with riveted or bolted or welded attachment and as directed by the Engineer-in-Charge
Writing letters or figures by stenciling, 8 CM height (white enamel paint)(Block,Roman,Italic or Indian ) not exceeding 30 cm height.
S&Fof GI pipe medium grade 100 mm dia. under the road/ hard standing/Traverse.
S&Fof GI pipe medium grade 50 mm dia. for 32x6mm earth flat from earth pit to Bldg.
Supply & laying of UN-REINFORCED PRECAST CONCRETE CABLE COVER , CLASS LV, Type I, flat, size 250mm x 150mm x 40mm
M&L for XLPE insulated PVC sheathed armoured with galvanized strip steel U.G. cable with Aluminium conductor electric cables 3.5 core X 150 Sq. mm 1100 Volt grade,.as per IS:1554(part-1) & IS:7098(part-1) etc as required GLOSTER/POLYCAB/HAVELLS/UNIFLEX MAKE. Firm has to submit test reports.
M&L for XLPE insulated PVC sheathed armoured with galvanized strip steel U.G. cable with Aluminium conductor electric cables 3.5 core X 300 Sq. mm 1100 Volt grade,.as per IS:1554(part-1) & IS:7098(part-1) etc as required GLOSTER/POLYCAB/HAVELLS/UNIFLEX MAKE. Firm has to submit test reports.
Material and Labour for One light point controlled by one switch with 2.5 sq.mm. copper conductor FR PVC insulated multistranded conductor cable of Polycab/Finolex/Havells/V-Guard/HPL make in PVC conduit with saddle spacer along with 2.5 sq.mm copper conductor FR PVC insualted for running earth wire of same make .
M& L for PVC /Poly carbonate type Angle / pendent type Lamp holder . Anchor /CONA/Havells/ Legrand Make
S&F of switch piano flush single pole two way 5 amp Anchor /Cona/Havells make.
M&L for Switch socket combination 2 in 1 ,3 Pin, 5 and 15 Amp flush type universal, Anchor /CONA/Havells/ Legrand make.
S&F of PVC rectangular block for mounting ceiling roses, holders etc of size 100 mm X100 mm and 50 mm deep. Anchor /CONA/Havells/ Legrand make
M & L for celing rose,3 phase/PVC/Polycarbonate ,isolated body.Anchor /CONA/Havells/ Legrand make
M&L for earthing complete with galvanised steel earth plate elecrode 60X60 cm X6 mm thick,buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level,connected to galavanised strip 32X6 mm as earthing lead by means of bolts,nuts,check nuts and washers of galvanised iron or steel including upto 7.5 mtr length /test point as per IS:3043/1987 and SSR-2020 Plate no.3 & indiacted testing on completion as directed by EIC.
M&L for earrth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32X6 mm galvanised iron strip.
Writing for circuit/submain wiring alongwith earth wire with the 2x2.5 sqmm + 1x1.5sqmm earth wire sizes of Polycab/Finolex/Havells/V-Guard/HPL make FR PVC insulated copper conductor, single core cable in surface/recessed in PVC conduit as required.
Writing for circuit/submain wiring alongwith earth wire with the 2x4.0sqmm + 1x1.5sqmm earth wire sizes of Polycab/Finolex/Havells/V-Guard/HPL makeFR PVC insulated copper conductor, single core cable in surface/recessed in PVC conduit as required.
Demolition built in cement concrete of any description and in any position.
Supply and fixing of exhaust fan, steel bodyAC single Phase. 230V of size 300mm (12") sweep with, blades, and frame and louvers. Usha/BajajCrompton/Almonard/Orient make.
Supply and fixing of exhaust fan, steel body AC single Phase. 230V of size 450mm(18'')sweep with, blades, and frame and louvers.Usha/BajajCrompton/Almonard/Orient make.
M & L for remaking of dismantled portion of concrete / road or grouting pole/stay/LP base by PCC of 1:2:4 of type B-1 using 20 mm aggregate.
Supply and laying of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. In the existing trench complete as req. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply , laying , fixing & connection (by using heavy duty brass single cable gland and copper lugs) of XLPE insulated PVC sheathed armoured with galvanized strip steel U.G. cable with COPPER conductor electric cables 4core multi strand X 4 Sq. mm as per IS:1554(part-1) & IS:7098(part-1) etc as required Gloster/polycab/Havelles/Uniflex/Finolex/CCI make.
Supply and making end termination with brass heavy duty SINGLE compression gland and heavy duty BI-METALLIC lugs for of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required per cable per end as one set. Cable size 3½ X 300 sq. mm. Bi-metallic lug test certificate to be submitted by the contractor.
Supply and making end termination with brass heavy duty SINGLE compression gland and heavy duty BI-METALLIC lugs for of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required per cable per end as one set. Cable size 3½ X 150 sq. mm. Bi-metallic lug test certificate to be submitted by the contractor.
Supplying and laying of DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. In the existing trench complete as req. ID more than 109 mm nominal thickness 6mm for fitting to 100mm GI Pipe at bending portion as directed by EIC.
Supply & Fixing of LT cable route marker made out of 12.5 cm dia.CI plate duly rivated on top of 40x40x6 mm angle from (duly) Painted with Blacksynthetic/enamelled paint) 0.75 Mtr. long and PCC cube 15x15x15 cm at bottom.
M&L for earrth continuity conductor or main earthing lead fixed to wall on batten or parapet or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X5 mm galvanised iron strip.
Supply & fixing of G.I. watering pipe in earth pits medium grade 25 mm Dia with GI nuts & bolts ,2 nos of clamp ,funnel, steel wire mess etc .
Supply, Installation, Testing and Commissioning of wall mounted fan, 18 inch (450mm) sweep with oscillation, metal body and metal blade, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Usha/BajajCrompton/Almonard/Orient make.
M & L Cast iron pressed steel terminal boxes 60mm deep size 150x150mm rectangular for mounting, switches, sockets, fan regulator etc with 3mm thick pastic laminared sheet cover not exceeding the size 175x100mm.
M & L Cast iron pressed steel terminal boxes 60mm deep size 250x300mm rectangular for mounting, switches, sockets, fan regulator etc with 3mm thick pastic laminared sheet cover.
M & L Cast iron pressed steel terminal boxes 60mm deep size 200x150mm rectangular for mounting, switches, sockets, fan regulator etc with 3mm thick pastic laminared sheet cover.
Supply and fixing of double tube light fittings 2 x 20 watt, 230 vot AC. Bajaj, Surya, Cromton, Philips make.
Supplying , installation, testing & commissioning of LED Street Light luminaire made of die cast aluminium with street optic lenses for uniform light distribution, IP:66 protection having system lumens output not less than 3000 lumens and power consumption shall not exceed 30 watt, CCT not less than 5700, CRI not less than 70 i/c built in electronic driver and surge protector connection etc as reqired along with bracket & clamp fabricated from heavy duty 32/40/50mm dia GI pipe for wall mounting of LED fitting along with SS nut bolt washer complete (Make: Crompton/Philips/CG/Wipro/Bajaj)
Supplying , installation, testing & commissioning of LED Street Light luminaire made of die cast aluminium with street optic lenses for uniform light distribution, IP:66 protection having system lumens output not less than 6500 lumens and power consumption shall not exceed 60 watt, CCT not less than 5700, CRI not less than 70 i/c built in electronic driver and surge protector connection etc as reqired along with bracket & clamp fabricated from heavy duty 32/40/50mm dia GI pipe for wall mounting of LED fitting along with SS nut bolt washer complete (Make: Crompton LST-60-CDL-M or equivalent in Philips/CG/Wipro/Bajaj)
Supply, installation and testing of Lighting Distribution Panel-01 No. comprising of a) Incoming: 400A, 4P, MCCB 36/50 KA: 1 No. b) Outgoing: 250A, 4P, MCCB 36/50 KA: 1 No., 100A, 4P, MCCB 25/36 KA: 1 No. 32A, 4P, MCB 10 KA: 3 No., c) Outgoing: 16A, DP, MCB 10 KA C-Curve: 10 Nos. MCCB shall have Rotary handle mechanism brought outside front panel for operation. MCB should be operated from outside without opening of front door of panel with 125A RYBN copper bus bar with 100% neutral complete in all respect including all necessary accessories with suitable gland openings in incoming and outgoing and suitable space for existing incoming cable connections with the MCCB incomer with suitable anchor fastners for grouting arrangement, angle iron framework etc as required. CRCA Sheet thickness 2mm, Both Wall mount and floor mount option. Powder coated siemens gray. Firm supply required foundation frame and instal the panel over frame. Make: ABB / L&T/ SIEMENS/ SCHNEIDER ELECTRIC / MERLIN GERIN/GE.
Supply, installation and testing of Lighting Distribution Panel-01 No. comprising of a) Incoming: 63A, 4P, MCCB 25 KA: 1 No. b) Outgoing: 32A, 4P, MCB 10 KA: 2 No., c) Outgoing: 16A, DP, MCB 10 KA C-Curve: 4 Nos. MCCB shall have Rotary handle mechanism brought outside front panel for operation. MCB should be operated from outside without opening of front door of panel with 100A RYBN copper bus bar with 100% neutral complete in all respect including all necessary accessories with suitable gland openings in incoming and outgoing and suitable space for existing incoming cable connections with the MCCB incomer with suitable anchor fastners for grouting arrangement, angle iron framework etc as required. CRCA Sheet thickness 2mm, Both Wall mount and floor mount option. Powder coated siemens gray. Firm supply required foundation frame and instal the panel over frame. Make: ABB / L&T/ SIEMENS/ SCHNEIDER ELECTRIC / MERLIN GERIN/GE.
S&F testing point, made of 32 mm X 6 mm thick G.I. strip, 125 mm long, with 4 nos. of SS bolts, nuts, chuck nuts and spring washers etc. complete as required
Supplying, fabricating & fixing of 200x200x8mm G.I. base plate with suitable fastners on the existing CC blocks i/c providing & fixing of 40mm medium class G.I. Pipe of height 2.1 mtr. For fixing of air termination i/c weldding of G.I. base plate & G.I. pipe with suitable 4 Nos. of G.I. cleat i/c fixing of air termination finial, G.I strip complete etc. as reqd. with heavy duty epoxy support insulators as directed by EIC.
Supplying & fixing of red colour heavy duty DMC earthing G.I. strip insulator for fixing of lightning protection etc. complete fixing with hardwares of stainless steel as reqd.
RAJESH ELECTRICAL CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .