Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.8 LAccepted-AOC | L1 | Accepted-AOC Accepted |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
11 Sept 2023, 6:55 pmClosed
SH DC SHARMA IDSE
CWE (NW) KOCHI
SPECIAL REPAIRS / REPLACEMENT OF CEILING MOUNTED LED OPERATION THEATER LIGHTS AT INHS SANJIVANI
2023_MES_594180_3
CWE(NW)KOCHI/81367
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AS PER NIT
6 documents required · 6 mandatory
₹1,000
GE (NW) KOCHI
₹1.3 L
Yes
9 Nov 2023
12 Aug 2023
13 Sept 2023
12 Aug 2023
11 Sept 2023
19 Aug 2023
Amount
Supply, fix, testing and commissioning of Double Dome OT Light Elite (1,60,000 x 1,60,000 Lux) with full HD Qe3H60 Camera with high end light upgrade complete all as specified and as directed. Light Quality Characteristics (a) Light Intensity (Lux) : 1,60,000 Lux X 1,60,000 Lux (b) Number of Light Source : 90 39 (c) Light Field Diameter (d10 Distance of 1m) : 200-420 mm 150-320 mm (d) Light Freight Diameter (d50 Distance of 1m) : 120-250 mm 90-160 mm (e) Beam Uniformity (d50/d10 Ratio) : 0.6 (f) Comfort Halo (at 1m) : 2,000 mm 1,500 mm (g) Colour Rendition Index Ra : 95 (h) Colour Rendition Index R9 : 95 (j) Colour Temperature : 3,100 k to 5,000 k (5 steps) (k) Removable Sterile Handle : 2 Nos Electrical & Mechanical Characteristics (a) Nominal Power Consumption : 2.07A/48W 1.7A/41W (b) Radiant Energy : <3.31mW/m2Lux (c) Degree of Protection : IP54 (d) LED Life : >60,000 Hours Make : KLS MARTIN GERMAN/BRANDON UK/ STERIES or equivalent make approved by GE
Note :- Double Dome LED Operating Theatre Light with Full HD Camera with the following detailed specification, • The Operating Theatre Light should comprise of a double structure with 2 lamp heads 160000lux each dome with 360-degree rotation in all the arms and light head. The lamp heads should have multiple LED light sources including a combination of red and white LEDs to optimize colour rendition. The light should provide deep, direct, shadow less illumination. It should be cool, Infrared-free light which prevents tissue from drying out in the operating field. • The OT Light system includes the option to adjust the lamp head mounting height by adding modular extensions to the verticals. (These stack up by screwing extra ones on the bottom) • The OT light system includes a large, high quality ceiling cover which covers the larger holes in the ceilings left by other manufacturers. • The ceiling cover system provides a mounting for the power supplies beneath the ceiling cover which simplifies wiring installation and makes the PSU accessible for service. • The ceiling cover provides mountings for additional power supply units for monitors. The monitor arm solutions are pre-cables with standard cabling and our high quality, with medical approved power supply. • Monitor Cables plug directly into medical grade monitors or are provided with converter wiring to allow installation of other non-medical grade monitors. • The systems can be rewired with camera cables, so every central axis is effectively ‘camera prepared’. • A arm can be converted to a stopped monitor arm by adding the stop ring and vice versa. So, a lamp arm can convert to carry a monitor and a monitor arm can be converted back to a lamp. • The system allows for stopped bottom arms and stopped top arms to support the installations of cameras and monitors. • The introduction of the ‘Stopped Top Arm’ cable should allow multiple cables to be routed to a monitor arm without the use of expensive and complex wireless links.
Notes Continued: • The spring arm now features +45 -70 degrees of vertical movement which means that the light is less dependent on the correct mounting height and the lamp head can be brought down level with the OR table. • The Total system includes a polarity check indicator on the slip ring which helps to prevent damage to lamp heads by reverse polarity. • Covers are fixed in place with screws to avoid them being accidentally dislodged and screws are fitted with hygienic silicon covers. The covers have safety tags to avoid them accidentally being dislodged. • The OT light structure system is predominantly aluminium which reduces weight during installation and the Aluminium construction is highly corrosion resistant. • The system has again improved the levels of ingress protection to reduce the chance of damage when adverse environmental conditions allow condensation. • Brandon Medical can provide a full range of ceiling spacer frames to provide a thermal break between the cold stem and the building mounting in the warm and moist ceiling cavity space. • The 160000lux lamp heads should have a diameter minimum of 630mm for Main and 480mm for satellite, providing a compact and space efficient design to allow installation within a laminar flow theatre. • Double OT light should be supplied with emergency power back up with following specifications: • Emergency Power Units. –The system is designed to provide a single operating light with a maintained 24V DC Supply for a period of no less than 3hrs as in accordance with the regulatory and recommendatory documentation. • The unit required 230V AC under healthy conditions, in the event of a 230V AC Mains Power Failure, the batteries will provide the 24V dc with a seamless changeover.
Notes Continued: • It should also provide a NFC interface to view diagnostic information via the android App without opening the enclosure. It should be able to diagnose Cabinet Temperature, Battery Voltage, Supply voltage – supply output to the lamps, Supply current – Current in mA of the supply to the lamps. Battery Test Start Voltage current : voltage in mV of the supply to the lamps at the start of a The light should have 1. 5-step colur controls allowing the colour temperature of the light to be adjusted from 3,100 – 5000K° Kelvin via ‘Red Balance Control. 3100° K, 3300°K, 3700°K, 4200°K, 5000°K (5 steps) 2. The light should have a Comfort Halo (2000mm) to reduce eye strain for surgeons by creating a more gradual chance in contrast between the illuminated area and areas under general lighting. 3. OT light should be supplied with integrated full HD camera in built in the light head. 4. Double dome light head should have a feather touch control and wireless link to a wall mounted remote control to repeat all controls and indicators as: • Lamp head On/Off Control, Intensity, Colour adjustment, Field Size, Camera Zoom Control The Operating Theatre Light should meet the following technical specifications: • Light Intensity – 160,000 Lux (Main & Satellite) • Intensity adjustment should be from 5% to 100% • Number of LED Light Sources : Main – 90 & Staellite not less than 39 • Light Field Diameter (d10) : 200-420mm for Main, 160-320mm (sat) • Light Field Diamter (d50) Main 120-220mm, sat – 90-140mm • Beam Uniformity (d50/d10 Ratio) – 0.58 • Lamp Head Nominal Power Consumption – 48W
Notes Continued: • Radiant Energy mW/m2.Lux - <3.31 • Light head design to minimize infection – IP54 ingress protection, No to LED Life hours- >60,000 Hours, With 2 YEAR WARRANTY • Colour Rendition Index : Ra – 95 • Colour Rendition Index R1 – 99 • Colour Rendition Index R2 – 97 • Colour Rendition Index R3 – 93 • Colour Rendition Index R4 – 93 • Colour Rendition Index R5 – 98 • Colour Rendition Index R6 – 96 • Colour Rendition Index R7 – 94 • Colour Rendition Index R8 – 92 • Colour Rendition Index R9 – 95 • Red Balance Control to provide colour temperature of - 3100° K to 5000 K (3100°K, 3300° K, 3700° K, 4200° K, 5000° K) (5 steps) • Removable, Sterile Handle – 2 Nos All Control for both OT light and camera should be quoted in optional 1080p HD camera Specifications: • The HD camera is securely mounted in the light, improving infection control, and reducing system costs. • The 1080i camera provides superior high digital’ technology transmits the HD-SDI signal without further processing or scaling.
Notes Continued: Technical data for integrated HD camera : • Image Sensor 1/3” Progressive CMOS (Approx. 2.1 mega) • Scanning System 16:9 Progressive • Sync. System Internal • Effective Pixel 4,08,00,00 • Min. Illumination 0.2Lux (Day), 0.1Lux (Night), 0.005Lux (DSS on) • Horizontal Resolution 1080p/i • Lens Fixed HD lens • Functions Focus (Wide to Tele) 10x Optical Zoom, f-3.3 to 33.0 mm, F 1.8 to 3.4 • Zoom Movement Speed (Wide to Tele) 1.4 Sec (Focus Tracking ON) Exposure Auto / Manual • White Balance Auto (3,000°K~8,000°K) • ATW (1,900°K~11,000°K)Manual • Electronic Shutter NTSC : 1/30~1/30000 • PAL : 1/25~1/30000 1080i@50/60 or 59.94 1080p@50/60 or 59.94
Notes Continued: • Control RS-485 SONY-VISCA Protocol • General Operation Temperature 10 to 50 degree c • Power Input From OT light • Power consumption Approx 3W • It should have latest CE Medical Device Directive 93/42 EEC and including the 2007/47/EC Certificate, IEC 60601.2.4.1 Electrical Safety certificate and ISO13485 all latest certificates • Certificate of country of origin and manufacturers test certificates will be submitted after installation. . Rate shall be inclusive of 2 years warranty . The contractor shall provide training and demonstration for the staff with operating and servicing manual circuit diagram . All civil and electrical works required to complete the installation of OT lights including scaffolding/ladder etc shall be included in the quoted rate. . The complete installation of OT lights to be carried out by OEM only . 04 Nos cell ( comprising of 10 Nos LEDs) for main dome and 04 Nos cell ( Comprising 13 Nos LEDs) for auxiliary dome as included in number of light source as above to be provided as spare. The cost for these spare items shall be included in the quoted rate.
M&L for taking down carefully the existing UNSV OT lights of any wattage complete all as specified .
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .