Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 CrAdmitted-Finance | ₹38.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹38.8 CrAdmitted-Finance SRI KRISHNA VIHAR COLONY ROAD NO 74 SHANTI KUNJ BEUR ANISHABAD PATNA 800 002 | PATNA | PATNA | BIHAR | 800002 | ₹38.8 Cr | L2 | Admitted-Finance |
| 3 | L3₹42.7 CrAdmitted-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA UDYAM DL 06 0048538 | NORTH WEST DELHI | DELHI | 110035 | ₹42.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹47.8 CrAdmitted-Finance | ₹47.8 Cr | L4 | Admitted-Finance |
| 5 | L5₹49.8 CrAdmitted-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹49.8 Cr | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SETH GHANSHYAM DAS LAKHMAMI AND CO L7 | NIRMAL SALES CORPORATION L3 | SHRISTI DEVELOPERS PRIVATE LIMITED | MAA BHAGWATI ASSOCIATES L6 | NARSINGH DEVELOPERS LLP L5 | UMAKANT SINGH L1 | M/s MATRISWA CONSTRUCTION PRIVATE LIMITED L2 | CHHABINDRA KUMAR PRADHAN L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00BUILDINGS & STRUCTURE (Sch 'A' PART-I) | |||||||||||
| 1.01 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 35,84,00,000.00 inserted by the MES in Schedule ‘A’ Part-I. | 1 | LUMP SUM | 49,42,84,500 ₹49.4 Cr | 38,58,25,292.29 ₹38.6 Cr | - | 50,00,00,000 ₹50 Cr | 44,95,00,000 ₹45.0 Cr | 33,36,41,520 ₹33.4 Cr | 34,72,00,000 ₹34.7 Cr | 43,50,20,000 ₹43.5 Cr |
| 2.00EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) | |||||||||||
| 2.01 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 64,06,967.70 inserted by the MES in Schedule ‘A’ Part-II. | 1 | LUMP SUM | 33,25,200 ₹33.3 L | 34,55,700 ₹34.6 L | - | 51,00,000 ₹51 L | 39,00,000 ₹39 L | 79,66,087 ₹79.7 L | 55,00,000 ₹55 L | 38,44,180.62 ₹38.4 L |
| 3.00INTERNAL ELECTRIFICATION (Sch 'A' PART-III) | |||||||||||
| 3.01 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-III.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,81,978.96 inserted by the MES in Schedule ‘A’ Part-III. | 1 | LUMP SUM | 13,15,600 ₹13.2 L | 15,43,845.6 ₹15.4 L | - | 15,00,000 ₹15 L | 15,89,000 ₹15.9 L | 16,58,375 ₹16.6 L | 11,85,000 ₹11.8 L | 13,81,978.96 ₹13.8 L |
| 4.00ROAD, PATH, CULVERT AND HARDSTANDING (Sch 'A' PART-IV) | |||||||||||
| 4.01 | Lump sum price worked out by the Contractor for “ROAD, PATH, CULVERT AND HARDSTANDING” as listed in Schedule ‘A’ Part-IV.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,45,25,416.38 inserted by the MES in Schedule ‘A’ Part-IV. | 1 | LUMP SUM | 1,82,52,660 ₹1.8 Cr | 1,52,28,797.9 ₹1.5 Cr | - | 1,88,00,000 ₹1.9 Cr | 1,80,00,000 ₹1.8 Cr | 1,67,04,228 ₹1.7 Cr | 1,30,25,000 ₹1.3 Cr | 1,45,25,416.38 ₹1.5 Cr |
| 5.00AREA DRAINAGE (Sch 'A' PART-V) | |||||||||||
| 5.01 | Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part-V.
Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 22,55,110.65 inserted by the MES in Schedule ‘A’ Part-V. | 1 | LUMP SUM | 22,79,450 ₹22.8 L | 23,83,685.98 ₹23.8 L | - | 30,66,000 ₹30.7 L | 24,95,000 ₹24.9 L | 25,93,376 ₹25.9 L | 19,25,000 ₹19.3 L | 22,55,110.65 ₹22.6 L |
Updated dates
Tender Value
₹43.5 Cr
EMD Value
₹15 L
Closing Date
17 Feb 2026, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, DIST JALPAIGURI, PIN 734 008 (WB)
PROVN OF TECHNICAL BUILDING AND ALLIED WORKS (PH-II OF TWO PHASES) AT KATIHAR UNDER AGE(I) KATIHAR
2025_MES_744172_1
98807BENG/SZ/E8
Open Tender
Civil Works
730 days
KATIHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
AGE (I) KATIHAR
₹15 L
Yes
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA
25 Mar 2026
11 Dec 2025
24 Feb 2026
11 Dec 2025
17 Feb 2026
15 Jan 2026
11 Dec 2025 - 20 Dec 2025
26 Dec 2025
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
FIRE ALARM Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4.0 Sq mm, 2 Core, 1100 Volts grade complete all as specified and directed.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 66,38,405.55 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL ELECTRIFICATION (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,81,978.96 inserted by the MES in Schedule ‘A’ Part-III.
ROAD, PATH, CULVERT AND HARDSTANDING (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “ROAD, PATH, CULVERT AND HARDSTANDING” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,45,25,416.38 inserted by the MES in Schedule ‘A’ Part-IV.
AREA DRAINAGE (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 22,55,110.65 inserted by the MES in Schedule ‘A’ Part-V.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,08,979.80 inserted by the MES in Schedule ‘A’ Part-VI.
SECURITY LIGHT AND STREET LIGHT (Sch 'A' PART-VII)
Lump sum price worked out by the Contractor for “SECURITY LIGHT AND STREET LIGHT” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 2,33,753.20 inserted by the MES in Schedule ‘A’ Part-VIII.
FIRE FIGHTING (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “FIRE FIGHTING” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,06,332.00 inserted by the MES in Schedule ‘A’ Part-VIII.
FIRE ALARM (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “FIRE ALARM” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 15,13,000.90 inserted by the MES in Schedule ‘A’ Part-IX.
LIGHTNING PROTECTION (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,79,299.36 inserted by the MES in Schedule ‘A’ Part-X.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XI)
RATE In Figures To be entered by the Bidder Rs. P
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 38,34,96,000.00 inserted by the MES in Schedule ‘A’ Part-I.
Supply and fixing Flame proof mettalic junction Box 4 way, Threaded type complete all as specified and directed.
Supply and fixing Flame proof flexible metalic Hose conduit 20 mm dia, 500 mm long complete all as specified and directed.
EXTERNAL WATER SUPPLY Supply and laying pipe ductile Iron , S/S including specials, Class “K-7” ,80mm (3”) dia, for SWT including rubber gaskit push on joint complete all as specified and directed.
SECURITY LIGHT / STREET LIGHT S&F steel tubular swaged poles type 410 SP-31(9.0 meter long) Swan Neck Type complete with CI base plate and finial and single swan neck complete all as specified and directed.
S&F junction box DIA 300 X 200 X 105 made out of polycarbonate with IP 55/IP 65 protection of suitable size including - 04 Nos cable terminal, 02 Nos polycarbonate cable gland , 01 Nos DIN rail and 01 No. MCB SP, 10 KA 6 Amps complete all as specified and directed.
FIRE FIGHTING Supply and laying pipe ductile Iron , S/S including specials, Class “K-9” ,150 mm (6”) dia, for Fire Hydrent system including rubber gaskit p
Supply and laying pipe ductile Iron , S/S including specials, Class “K-9” ,80 mm (3”) dia, for SWT including rubber gaskit push on joint complete all as specified and directed.
Supply and fix 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903 complete all as specified and directed.
ush on joint complete all as specified and directed.
S&F of flame proof metallic junction box 4 way, threaded type complete all as specified and directed.
ROAD, PATH, CULVERT AND HARDSTANDING M&L for 3.00 mm thick painting to road surfaces as in lines, dashes, arrows, letters, zebra cross etc, on roads, pavements and the like etc with thermoplastic road marking paint @ 5 Kg/Sqm and applying glass grit @ 300 gms/Sqm over painted surfaces while the painting surfaces are hot including cleaning surfaces complete all as specified and directed. NOTE : Both application shall be carried out through meachanical application by the approved applicator of manufacturer of paint.
(A6) Engine mounted microprocesser based (perferably) instrument panel with digital dispaly for the following:- (i) LED indicating lamps-for Genset running, remote start, shutdown, warning, manual, auto and stop, (ii) Data Logs-engine run time and controller on time, (iii) Start/ Stop switch with key, (iv) Indication/Display of for water temp, lub oil pressue, lub oil temp, bettery charging, RMP, over speed, low lub oil trip, Engine hours, (v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency KWH shall be displayed, (B) protection to Genret. (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown, (iIi) Low coolant temp warning, (iv) Sensor failure indication, (v) Low/High battery voltage warning, (vi) weak battery warning, (vii) fail to start shutdown, (viii) Cranking lockout, (ix) High/Low AC voltage shutdown, (x) under/over frequency shutdown, (xi) loss of sencing voltage shutdown. (C) Others, (i) AVM Pads, (ii) First fill of lubricating oils, (iii) flywheel with housing, (iv) flywheel with housing, (iv) Residental silencer. (D) Alternator synchronous alternator copper wounded rated 82.5 KVA, 415 volts, 1500 RPM, 3 phase, 50Hz, AC supply with 0.8 lagging power factor at 50 degree C, 50% RH and 500 MSL, brushless type, self exicited, SPDP encl, contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating bearing (b) Permissible overloading of 10% for one hour in every 12 hrs of continuous operation (c) permissible unbalancing capability minimum 25% per phase.
Supply, install, testing & commissioning of LT panel board "out-door type" of size 1200 mm (height) x 1200 mm (breadth) x 600 mm (depth) (minimum dimensions) factory fabricated CPRI type-tested with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable & 4 side slanting canopy on roof top. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & Aluminium bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming MCCB rating. The panel board shall be fabricated out of 3.15 mm thick CRCA sheet duly pre-treated & powder coated, supporting frame made out of 50X50X5 mm angle iron & MC 100 channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork complete all as specified & as directed with & incl the following accessories : (DG DIS PANEL) BUS-BAR & internal connections:- The bus-bars shall be made up of 04 Nos Aluminium 200 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc. PROVISION FOR CABLE ENTRY :- The provision for cable entry/exit shall be provided in the bottom for both incomming & out-going cables. INCOMING :- MCCB 4P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit & adjustable overload setting having breaking capacity 16 KA of rating 100A - 01 Nos. Item Continued as 11.18
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_833283.xls
BOQ • 0.27 MB
Complete_Tender_Except_BOQ.pdf
Tender Documents • 4.84 MB
Drgs.rar
Additional Documents • 19.57 MB
Download all tender documents and submit your bid