Construction of PHC at Pahloo, Kulgam B.W.O Electric work
2026_PWDJK_302045_1
NIT No.272/2025-26 Dt/02/02/2026
Open Tender
Electrical Works
Percentage
Pahloo kulgam
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹90,741
2 Feb 2026
2 Feb 2026
24 Feb 2026
2 Feb 2026
23 Feb 2026
2 Feb 2026
Wiring for lighting points/fan points/ exhaust fan points/call bell points with 1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch , modular plate and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent make ) excl. cost of conduit.
Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing, etc. as required. (Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent ) excl. cost of conduit
Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 6 pin 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent make to be approved by EIC)
Supplying and fixing of suitable size GI box with modular plate and modular cover in front on surface or in recess, including providing and fixing of 2 no. 3 pin 5/6 A modular socket outlet and 2 no. 5/6A modular switch, connections, etc. as required. (Havells/ SSK/ Anchor/ABB/Schneider or eq.)
Supplying and fixing of modular sockets/ indicators/switches on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent)
i.3 pin 5A - 10A socket.
ii. indicator.
Point wiring for 5A -10A socket out lets (computer points) with 2x2.5 sq mm (P+N)FRLS PVC insulated 660/1100volt grade flexible stranded copper conductor wires of Havells/ Polycab/ Anchor/ Finolex/KEI/RR make in recessed or surface conduiting system and earthing the point with 1 x 2.5 sq. mm single core copper wire (loop earthing),(Maximum two points shall be connected on one circuit).(Havells/ Polycab/ Anchor/ Finolex/KEI/RR or equivalent) excl. cost of conduit
Supply, installation, testing and commissioning of 18 Watt LED recessed/ mounted (round or square) Down lighters having aluminum body, minimum 100im/w, average life 50000 hours, LM79 & LM80 test report should be from Govt. Approved NABL lab / Govt. Of India , Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro/ eq. make to be approved by EIC). Commercial series.
Supply, installation, testing and commissioning of 10 Watt (2 feet long) LED wall mounted batten ( tube lights) having aluminum housing, minimum 100im/w, average life 50000 hours (Commercial series) The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of one year reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro/ eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 5 Watt (1 foot long) LED wall mounted batten (mirror lights) having aluminum housing, minimum 100im/w, average life 50000 hours (Commercial series) The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of one year reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro/ eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 1 star 1200 mm sweep ceiling fans of Havells / Crompton Greaves/Bajaj/ Usha/ Anchor/ eq. make to be approved by EIC (Sample to be got approved), incl. cost of extension of GI rod (if required) and making of necessary connections.
Supply and fixing of two module stepped electronic fan regulator on the existing modular plate switch box, incl. connections but excluding modular plate etc. as reqd.
Supply, installation, testing and commissioning of 200-250 mm sweep shutter type exhaust fans, incl. cost of making of space in walls/ windows as per site and necessary connections. (Havells/ Philips/Crompton/Anchor/ eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 400mm sweep wall fans, incl. cost of ceiling rose and making of and necessary connections. (Havells/ Philips/ Crompton/ Anchor/ eq. make to be approved by EIC).
Supply, installation, testing and commissioning of 100Watt LED Flood lighting luminaries having aluminum body, minimum 100im/w, the luminary housing should be aluminum and the luminary optics shall have a high efficiency with transmittance, average life 50000 hours, Operating temperature -10`C to +45`C. The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department.
Supplying and fixing of modular blanking plates on existing modular plate and switch box ,excluding modular plate as required.
Wiring for sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excl. cost of conduits(Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent).
2 x 1.5 sq.mm + 1x 1.5 sq. mm earth wire
2 x 2.5 sq.mm + 1x 2.5 sq. mm earth wire
2 x 4 sq.mm + 1x 4 sq. mm earth wire
2 x 6 sq.mm + 1x 6 sq. mm earth wire
4 x 10 sq.mm + 2x 6 sq. mm earth wire
4 x 16 sq.mm + 2x 6 sq. mm earth wire
Supply and fixing of following sizes of medium class PVC conduits along with accessories, recessed in RCC slabs/walls, including cutting of walls and making good the same.
A. 25 mm dia.
B. 32 mm dia.
Supply and installation of 32A Industrial/modular plug/socket with 32A MCB for ACs
Supplying and fixing following size of perforated painted with powder coating M S cable trays with perforation not more than17.5% in convenient sections, joined with connectors, suspended from the ceiling with M S suspenders including bolts and nuts, painting suspenders etc. as required.
i. 200mm x 50mm x 1.6mm
ii. 300mm x 50mm x1.6mm
Supply and fixing of following surface/recess mounting , Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer.
i. 6 Way (4 +18) Double door
ii. 8 Way (4 +24) Double door
Supply, installation, testing and commissioning of 5-32A single pole rating 240/415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.
耀 蔀℀蠀 退℀鄀 餀℀鰀 ꈀ℀ꔀ 글℀넀 똀℀뤀 묀℀븀 였℀준 턀℀퐀 ℀ ℀ ℀ ℀ ︀℀ Ȁ℁Ѐ ℁ഀ ᜀ℁ᤀ ἀ℁℀ ␀℁─ ⴀ℁⸀ ℁㈀ 㜀℁㠀 㰀℁㴀 㸀℁㼀 䀀℁䄀 䐀℁䔀 䠀℁䤀 䬀℁䰀 刀℁匀 圀℁堀 帀℁开
Supply, installation, testing and commissioning of 40A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A TP&N rating 240/ 415V, 10 KA “C” curve MCB of Legrand/ Havells/ L&T suitable for inductive load in the MCB distribution board complete with necessary connections.
Providing / laying of shock proof rubber mat of 2mtr x1 mtr and 12 mm thick in size.
Providing of chemical earthing as per IS standards by way of digging 8 feet pit then embedding 3 mtr. Long GI earthing electrode, 80 mm dia. Connecting the plate with main control board by 10 SWG Copper wire with 1/2” dia. Full thread brass nut and bolts and washers, refilling the pit with chemical compound.
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear (c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
Normal Incoming
400 Amp, 50 KA, FP MCCB incl. Spreader links
ON Load Change Over Switch FP 400 amp. (Front operated)
Aluminum Bus Bar 800 Amp set of 4 strips
Aluminum Bus Bar 600 Amp set of 4 strips
Outgoing
250 Amp, 50 KA, FP MCCB incl. Spreader links
200 Amp, 36 KA, FP MCCB incl. Spreader links
SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear (c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator, CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge. (THREE PANELS FOR GROUND/FIRST AND SECOND FLOOR)
Providing and fixing following rating and breaking capacity and pole MCCB with thermo magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type) (THREE PANELS FOR GROUND/FIRST AND SECOND FLOOR)
Normal Incoming
200 Amp, 35 KA, FP MCCB incl. Spreader links (1no. x 3 panel)
Aluminum Bus Bar 500 Amp set of 4 strips (1set. x 3 panel)
200 Amp, 25 KA, FP MCCB incl. Spreader links (1no. x 3 panel)
Aluminum Bus Bar 400 Amp set of 4 strips (1 set. x 3 panel)
Outgoing
125 Amp, 36 KA, FP MCCB incl. Spreader links (3no. x 3 panel)
100 Amp, 30 KA, FP MCCB incl. Spreader links (3no. x 3 panel)
Space for 24 way MCBs (1job. x 3 panel)
Supply, installation , testing and commissioning of 50 KVA, 3-Phase, 415V,LT, Unbalanced AVR , operating from input voltage of L-L=320 - 460V & L-N=90-265V, thereby producing the output voltage of 415V +_2% Phase to Phase and 230V +_2% Phase to Neutral. The AVR should have inbuilt Over voltage protection, Under voltage protection & Over loading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di-electric strength. The stabilizer shall be capable of smooth operation up to 10% un- balanced in the load currents complete with servo bye pass system consisting of 200A four pole manual type change over switch. The supplier has to give guarantee for any manufacturing defect with three servicing of the equipment for two years reckoned from commissioning. The job also includes all applicable taxes, carriages , loading and unloading. (Alba/ Ess Ess Enterprises/ Cosco/AE).
Supply, laying, connecting and commissioning of 300 sq. mm 3.5 core PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade Aluminum LT cable , incl. cost of required al. thimbles duly crimped. ( under ground).
Supply and fixing of ceiling rose , incl. base block and necessary connections.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.04 MB
BOQ_979966.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .