Rewiring of Sharda Sadan field Hostel at Tanakpur Power Station
2021_NHPC_629415_1
NH/TPS/PnC/NIT/2021/ E29424/817/31 dt 08/05/2021
Open Tender
Electrical Works
Works
45 days
NHPC Ltd. Tanakpur Power Station, Banbasa
As per tender document
5 documents required · 5 mandatory
₹590
NHPC Ltd. Tanakpur Power Station
Exempted
27 Aug 2021
11 May 2021
4 Jun 2021
11 May 2021
1 Jun 2021
11 May 2021
11 May 2021 - 25 May 2021
Amount
Rewiring for light point/ fan point/ exhaust fan poaint/ call bell point with 1.5 sq.mm FR LS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/ PVC conduit including dismantling as required.( Group-B ).
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. ( Group-C )
Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing 10 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commissioning etc. as required.
Supplying and fixing 25 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of single pole in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 32 A rating, 240/415V 10 KA "C" curve miniture circuit breaker suitable for inductive load of Tripple pole and Nuetral in the exiting MCB DB complete with connection testing and commiissioning etc. as required.
Supplying and fixing 4 way(4+12) Double Door Horizontal Type Three pole and neutral, Sheet Steel, MCB Distribution bord415 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator).
Supplying and fixing 6 way(4+18) Double Door Horizontal Type Three pole and neutral, Sheet Steel, MCB Distribution bord415 Volt on surface /recess complete with Tinned copper bus bar , neuteral bus bar earth bar/ Din Bar inter connection power painted including earthing etc as required. ( But without MCB/RCCB/Isolator).
Supplying and fixing 40A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing 5/6 amps modular switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 5/6 amps modular bell push switch on the existing modular plate and switch box including connections but excluding modular plate etc.as required.
Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & box including connections but excluding moduler plate etc. as required
Supplying and fixing 15/16 A modular swich on the existing modular plate and swich box including connections but excluding modular plate etc.as required.
Supplying and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate and swich box including connections but excluding modular plate etc.as required.
Supplying and fixing two module stepped type electronic fan regulator on tha existing modular plate swich box including connections but excluding modular plate etc.as required
Supplying and Fixing Call bell /Buzzer suitable for single phase 230V. Complete as required.
Supplying and fixing 2 module (75mm+75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 4 module (125mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 6 module (200mmX75mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying and fixing 12 module (200mmX150mm), GI box alongwith modular base & cover plate for modular swiches in recess etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Wiring for submain wiring alongwith earth wire with the 2x 2.5 sq. mm+ 1x 2.5 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Wiring for submain wiring alongwith earth wire with the 2 x 4 sq. mm+ 1x4 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Wiring for submain wiring along with earth wire with the 2 x 6 sq. mm + 1x6 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Wiring for submain wiring along with earth wire with the 2 x 16 sq. mm + 1x6 sq.mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.
Supplying and fixing of 25mm of medium class PVC conduit along with accessories in surface /recess including cutting tha wal and making good tha same in case of recessed conduit as required.
Providing and fixing 100 A rating and 30KA breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Providing and fixing 250 A rating and 50KA breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Providing and fixing 400 A rating and 50KA breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .