Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.7 L+₹2.8 L (11.1%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹28.5 L
EMD Value
₹57,000
Closing Date
5 Feb 2022, 6:00 pmClosed
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur PIN 342027
REPAIR, MAINT TO LT OVERHEAD CONDUCTORS, UG CABLES, LT PANELS, CAPACITOR BANK, DIFFERENT CAPACITY OF DG SETS INCLUDING SPARES, RENEWAL OF EARTHING AND OTHER CONNECTED WKS AT RALAWAS UNDER GE BANAR
2021_MES_491972_2
8821/29/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Banar
₹57,000
Yes
9 Mar 2022
8 Jan 2022
7 Feb 2022
8 Jan 2022
5 Feb 2022
22 Jan 2022
Amount
Materials and labour for maintenance and servicing of DG Sets of following capacity complete all as specified and as directed.NOTE: (a) One service of DG Set is termed as ‘EACH JOB’.(b) Minor Spare parts like as rubber gasket,pin,seal etc shall be replaced under servicing without any cost and major parts like as oil filter, diesel filter,air filter & engine oil shall be measured & paid sepratelly under respective items of the schedule as supply only and fixing charge shall be deemed to be inculded in the unit rate of this scedule .
DG set of 320 KVA
DG set of 250 KVA
DG Set of 125 KVA
DG set of 63/62.5 KVA
DG set of 30/40 KVA
Labour only for repair and calibration of FIP of following DG Sets including strip opening and refixing of plunger, washer manifold, injection nozzles etc. all as required and testing after re-fixing on engine and setting the rated RPM complete all as specified and as directed.NOTE: Spare parts shall be measured and paid separately under relevent schedule items as supply only.
DG set of 320 KVA
DG set of 250 KVA
DG Set of 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40 KVA
Labour for overhauling of injector nozzles including strip opening and refixing of nozzles, washers, etc. and pressure setting as required for DG Sets of following capacities and replacement of timing shaft with coupling complete all as specified and as directed. NOTE: Spare parts shall be measured and paid separately under seperate under relevent schedule items as supply only.
DG set of 320 KVA
DG set of 250 KVA
DG st of 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40KVA
Labour for complete overhauling of self starter including strip opening and refixing of carbon bush, armature coil, field coil, bush and bendix pinion and other related components to the following capacities DG sets :NOTE: Spare parts shall be measured and paid separately under seperate under relevent schedule items as supply only.
DG set of 320 KVA
DG set of 250 KVA
DG Set 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40KVA
Labour only repair and overhauling of Battery Charging Alternator includingstrip opening and refixing of unserviceable armature coil, carbon set, field coil, clutch patti, bearing etc and other related items as required and re-fixing the same on mountings and testing complete for following capacities DG sets : Note: Spare parts shall be measured and paid separately under seperate seperate under relevent schedule items as supply only.
DG set of 320 KVA
DG set of 250 KVA
DG Set 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity 30/40KVA
Labour for repairing of Automatic voltage regulator, Diode forward and reverse, rotating rectifier accessories complete to the following capacity of DG set :- NOTE: Spare parts shall be measured and paid separately under seperate under relevent schedule items as supply only.
DG set of 320 KVA
DG set of 250 KVA
DG Set 125 KVA
DG set of 63/62.5 KVA
DG Set of capacity - 30/40 KVA
Strip opening the radiator and cleaning the same by water jet completely and detect the leakage/breakage and repair the radiator by soldering/brazing and testing complete all as specified and as directed for the following capacity of DG Sets :-
DG Set of capacity - 320 KVA
DG Set of capacity - 250 KVA
DG Set capacity - 125 KVA
DG Set of capacity - 63/62.5 KVA
DG Set of capacity - 30/40 KVA
Taking out burnt out winding and rewinding the alternator main field coil, rotor, exicitor coil, armature of any type with minimum 80kg copper enameled wire including other minor repairs, and testing and re-fixing the alternator after repair with alignment rotor with shaft and coupling with all required accessories for 125/100/63 KVA capacity DG set including necessary electrical and earthing connections complete all as specified and as directed.
Taking out burnt out winding and rewinding the alternator main field coil, rotor, exicitor coil, armature of any type with minimum 30kg copper enameled wire,Lumex paper,insulation tape ,insulation tube ,copper socket, including other minor repairs, and testing and re-fixing the alternator after repair with alignment rotor with shaft and coupling with all required accessories for 45/35/30 KVA capacity DG set including necessary electrical and earthing connections complete all as specified and as directed.
Supply and top up the coolant K Cool super plus-25/75 complete all as specified and as directed. MAKE: CASTROL/SERVO.
Supply and changing the engine oil of suitable grade including drain out existing used oil complete all as specified and as directed. Make : Servo/Castrol.
Supply only the following items in DG set of 320/250/125 KVA capacity.
Diesel filter element
Oil Filter element
Water pump assy
Air cleaner hose pipe with clamp
Radiator hose pipe with clamp
Safety control valve
Flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
Flexible pipe for Disel tank to filter with banjo washer , nut bolt
Air cleaner Filter
Oil pump
Automatic voltage regulator
(m) By pass filter
Supply only the following items in DG set of 63/62.5 KVA capacity.
Diesel filter element
Oil Filter element
Air cleaner hose pipe with clamp
Radiator hose pipe with clamp
Safety control valve
flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
flexible pipe for Disel tank to filter with banjo washer , nut bolt
Air cleaner Filter
Oil pump
Automatic voltage regulator
By pass filter
Supply only the following items in DG set of 40/30 KVA capacity.
Diesel filter element
Oil Filter element
Air cleaner hose pipe with clamp
Radiator hose pipe with clamp
flexible pipe for fuel pump to PT pump with banjo washer , nut bolt
flexible pipe for Disel l tank to filter with banjo washer , nut bolt
By pass filter
Automatic voltage regulator
Air cleaner Filter
Supply only following spare parts of Self starter spare parts of capacity 320/250 KVA as per existing make and cat part no-
Self clutch assembly
Self pinion assembly
Self solenoid switch assembly
Self Bandex Assembly
Self carbon rocker assembly
Self carbon brush (set of 4 pcs)
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 320/250 KVA as per existing make and cat part no-
Rectifier assembly
cutout assembly
Rotor assembly
carbon bush (Set of 2 Pcs)
Bearing
Stator assembly
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 125/63 KVA as per existing make and cat part no-
Rectifier assembly
cutout assembly
Rotor assembly
carbon bush (Set of 2 Pcs)
Stator assembly
Bearing
Supply only following spare parts of Battery charging Alternator for DG Set of capacity 30/40 KVA as per existing make and cat part no-
Rectifier assembly
cutout assembly
Rotor assembly
carbon bush (Set of 2 Pcs)
Stator assembly
Bearing
Supply only following spare parts of Self starter spare parts of capacity 125/63 KVA as per existing make and cat part no-
Self clutch assembly
Self pinion assembly
Self solenoid switch assembly
Self Bandex Assembly
Self carbon brush (set of 4 pcs)
Self carbon rocker assy
Supply only following spare parts of Self starter spare parts of capacity 30/40 KVA as per existing make and cat part no-
Self clutch assembly
Self pinion assembly
Self solenoid switch assembly
Self Bandex Assembly
Self carbon brush (set of 4 pcs)
Self carbon rocker assy
Supply only following spare parts of FIP spare parts of capacity 320/250 KVA as per existing make and cat No
Element
Delievery valve
FIP Repair kit
Supply only following spare parts of Injector for DG Set of Capacity 320/250 KVA as per existing make and cat No
Injector nozzle
Injector washer
Supply only following spare parts of FIP spare parts of capacity 125/63 KVA as per existing make and cat No
Element
Delievery valve
FIP plunger
FIP Repair kit
Supply only following spare parts of Injector for DG Set of Capacity 125/63 KVA as per existing make and cat No
Injector nozzle
Injector washer
Supply only following spare parts of FIP spare parts of capacity 30/40 KVA as per existing make and cat No
Element
Delievery valve
FIP Repair kit
Supply only following spare parts of Injector for DG Set of Capacity 30/40KVA as per existing make and cat No
Injector nozzle
Injector washer
Supply and fixing Engine stop solined switch for DG Set 320/250 as per existing make and cat no
Supply and fixing Engine stop solined switch for DG Set 125/63 as per existing make and cat no
Supply and fixing Engine stop solined switch for DG Set 30/40 as per existing make and cat no
Supply and fixing Alternator Fly wheel ring gear for DG Set 125/100/63 as per existing make and cat no
S&F for battery lead with terminal cable of copper conductor size of 19 SWG and 90cmm long as in repair completed as specified as dirtected by Engr-in-charge
Taking out burnt out winding and rewinding the Self startor coil, of any type with copper enameled wire including other minor repairs and testing and refixing the Self startor after repair with alignment rotor with shaft and coupling, Copper enameled wire, lumex paper, glass wire varnish and cotton tape etc with all required accessories for 320/250 /125 KVA DG sets including necessary electrical and earthing connections complete all as spedcified and as directed.
Taking out burnt out winding and rewinding the Self starter coil of any type with copper enameled wire including other minor repairs and testing and refixing the self starter after repair with alignment rotor with shaft and coupling, Copper enameled wire, lumex paper, glass wire varnish and cotton tape etcwith all required accessories for 63 /40/30 KVA DG sets including necessary electrical and earthing connections complete all as spedcified and as directed.
Site visit of OEM service Engineer as per DG set manufacturer for inspection and repair of DG sets as and when required basis as specified and dirtected by EIC Note:- (i) Spare parts shall be measured and paid separately under relevent schedule of items.(ii) All thr visit charge of service enginner of OEM will be paid by Contractor. Max two visit charges will be paid per DG set during inspection,repair and testing complete.(iii) Inspection of DG set of OEM service engineer and recommaded parts for repairs of DG sets/minor defacts rectified on the spot will be consider in Ist visit.(iv) Repairs of DG sets after material by the contractor and testing of DG sets as dirtected by EIC will be considered in 2nd visit.
Labour for servicing & replacement wornout parts ( relays,metering equipments,control circuits etc) of AMF pannel to the following capacity of DG set :- NOTE: Spare parts shall be measured and paid separately items as supply only.
DG Set of capacity – 320/250 KVA
DG Set of capacity - 125/63 KVA
DG Set of capacity - 30/40 KVA
Supply only power contactor 4 pole suitable for 320/250KVA DG AMF Panel .
Supply only SMPS for 320/250 KVA DG Set AMF panel
Supply only current transformer 200/5 A set of three for 320/250 KVA DG AMF Panel .
Supply only power fuse link with breaking capacity 80 KA for 320/250 KVA DG AMF Panel .
Supply only relay with board for 320/250 KVA DG AMF Panel .
Supply only controller circuit for 320/250 KVA DG AMF Panel .
Supply only power contactor 4 pole suitable for 125/63/62.5 KVA DG AMF Panel .
Supply only SMPS for 63 KVA DG Set AMF panel
Supply only power fuse link with breaking capacity 80 KA for 63 KVA DG AMF Panel .
Supply only relay with board for 63 KVA DG AMF Panel .
Supply only controller circuit for 63 KVA DG AMF Panel .
Supply only current transformer 200/5 A set of three for 63 KVA DG AMF Panel .
Supply only power contactor 4 pole for 30/35/45 KVA DG AMF Panel .
Supply only SMPS for 30/35/45 KVA DG Set AMF panel
Supply only current transformer 200/5 A set of three for 30/35/45 KVA DG AMF Panel .
Supply only relay with board for 30/35/45 KVA DG AMF Panel .
Supply only controller circuit for 30/35/45 KVA DG AMF Panel .
Supply and fix battery of capacity 150 AH 12V all as specified. Make :- EXIDE new xpress , cat part No FXPO-MHD 1500 or equavalent.
Supply and fix battery of capacity 180 AH 12V all as specified. Make :- EXIDE new xpress , cat part No FXPO-MHD 1800 or equavalent.
Supply and fix battery of capacity 120 AH 12V all as specified. Make :- EXIDE new xpress , cat part No FXPO-MHD 1200 or equavalent.
Supply and fix battery of capacity 100 AH 12V all as specified. Make :- EXIDE new xpress , cat part No FXPO-MHD 1200 or equavalent.
Supply fixing and testing Tarbo charger repair kit for DG Set cap 250/125/63 as per existing make and cat no
Supply , fixing and testing Tarbo charger repair kit for DG Set cap 35/40 as per existing make and cat No
Supply and fixing Amper meter for DG set as per existing make any type
Supply and fixing Water temp meter for DG Set as per existing make any tpye
M & L for painting to internal and external surface of LT Feeder Pillar Box/Panel Boards various sizes with two coats of synthetic enamel paint over a coat making necessary surface preparation by scrapping the pianted surfaces with wire brush/emery paper complete as per specified
Supply and fix Mild steel barrel tower bolts, 300mm long stove enamelled black, bright bolt. With connected accessories fixed on Front and rear side of the Doors for locking of LT FP Boxes complete as per specified
Material and labour for clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending, drilling holes for bolts, in any shape or size inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all complete as per dirtected by EIC
Material and labour for MS sheet 2mm/3.15mm thick for making doors of panel boards/feeder pillar boxes including taking out the old damaged doors complete work as per dirtected by EIC.
Replacement of corroded / damaged doors of panel boards/feeder pillar boxes by cutting, bending, welding MS sheet to suit with the existing MCCB's including providing hinges. Note ;- MS sheet will be measured and paid in separate item.
Material and labour for bus bar made out of aluminium strip as per existing suitable size(r-Y-B) colour insulated sleeve for phases and black colour for netural with suitable size of clamps made out of flat iron, nuts, bolts and washers including cutting, bending, welding etc and suitable as per existing complete as per dirtected by EIC
Supply and fix bus bar insulated for LT Panel/Feeder pillar heat resistance fire resistance type as per existing size and type complete as specified and dirtected by EIC
Supply and fixing DIN rail of width upto 35mm for mounting of Add on block/MCBs and other electrical items into LT panel/feeder pillar/juncation box complete
Supply and fixing DIN rail terminal block for 4 wire termination of LT cables complete as per specified and directed by EIC
Taking out/Dismantling of existing unserviceable UG Cable of any size after disconnetion from LT panel/feeder pillar complete.Note:- Earth work will be paid sepeartly
Laying in trenches or fixing or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed of following sizes. Note:- (i) Cable shall be issued under Schudle B free for fixing. (ii) Earthwork shall be measured and paid separately under relevant item of schedule 'Á'.
3.5 core 120 Sq mm
3.5 core 95 Sq mm
3.5 core 70 Sq mm
3.5 core 35 Sqmm
4 core 25 Sqmm
4 core 16 Sqmm
2 core upto 16mm
Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point.
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed.
M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection complete all as specified and dirtected
Laying only Old quarry faced stone slab retrived from respective items of sch.
Dismantling of existing unserviceable GI pipe 80/40mm .
Boring under road and foot path for inserting 40/80 mm bore GI tubing for drawing UG cable, complete all as per specified and directed NOTE- GI Pipe to be paid separate items .
Material and labour for 80 mm dia galvanized iron tube medium grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers.
Material and labour for 40 mm dia galvanized iron tube medium grade for cable protection pole ,plinth protection, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers.
Supply and fix LT straight through joint out door type of size 70 sqmm to 120 Sqmm 3.5/4 core suitable for PVC / XLPE power cables complete.Make : Dension/MS-Seal/Fontech.
Supply and fix LT straight through joint out door type of size 25 sqmm to 50 Sqmm 3.5/4 core suitable for PVC / XLPE power cables complete.Make : Dension/MS-Seal/Fontech.
Supply and fixing MCCB 4 Pole 320 Amp 415 volt breaking capacity 36 KA with adjustable thermal and megnetic setting compete.
Supply and fixing MCCB 4 Pole 250 Amp 415 volt breaking capacity 36 KA.with adjustable thermal and megnetic setting compete.
Supply and fixing MCCB 4 Pole 200 Amp 415 volt breaking capacity 25 KA.with adjustable thermal and megnetic setting compete.
Supply and fixing MCCB 4 Pole 125 Amp 415 volt breaking capacity 16 KA.with adjustable thermal and megnetic setting compete.
Supply and fixing MCCB 4 Pole 63 Amp 415 volt breaking capacity 16 KA.with adjustable thermal and megnetic setting compete.
Supply & fix digital power factor meter in existing panels of sutable size having range of 1/5 A and 110v/230v/440v with all acessories all as directed by Engr-in-Charge
Supply and fix CTs of ratio 200/5 A indoor resin cast ring type used on existing panel .
Supply and fix CTs of ratio 100/5 A indoor resin cast ring type used on existing panel .
Supply and fix CTs of ratio 50/5 A indoor resin cast ring type used on existing panel .
Supply and fixing LED type indicator lamp (RYB) (Set of three)
Supply and fixing Spreaders For LT Line heavy duty as per sepcified as per directed Make:- Indoasian or equivalent.
Supply & lay electrical insulation rubber matting as per ISI of size 1mx2 mtrx19mm Make: Jaipuria or equivalent
Supply and fixing Rotary Handle dirtect for panel Make:- Indoasian
Dismantling of existing damaged unserviceable earth pits, test points, GI wire / GI Strip / copper strip of any size complete
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below ground level connected to galvanized iron earth stip of size 32 x 6 mm by means of bolt, nut, check nut and washer of galvanized iron or steel protected by galvanized iron pipe of 40 mm bore light grade, incl. funnel, 20 mm dia bore galvanized iron pipe medium grade for watering, wire mesh, charcoal or coke and common salt in alternative layers all around the earth electrode compacted thickness 15 cm incl. excavation and earth work, PCC 1:3:6 type C2, CI pit cover, incl. disposal of surplus soil to a distance n. exc. 50 m, complete testing on completion, all complete as shown in electrical plate No 3, SSR Part-I all as specified and directed.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos, 8 mm dia 25 mm long hex head screw complete as specified as dirtected
Earth continuity conductor or main earthing lead fixed to wall /floor connection of earthing lead to equipment fixed to poles or any other indicated situation for loop earthing etc as required 32X6 MM dia galvanised iron strip complete as specified as dirtected .
M & L Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps bolts and nuts of approved for LT 440 volts, of size 25 X15cms complete as specified as dirtected
Material & Labour for PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation of LT panel as per directed by Engr-in -charge.
Cleaning the Surrounding area (not less than 2X2 mtr) of Two/Four pole structure,Lt panel area cutting the bushes,grass by root and leveling the soils, dressing the cables and two coat white wash on the panel foundation ,earth pit near around the Lt Panel etc complete as per directed by Engr-in-Charge
M&L for writing of LT panel number with black/blue colour on panels/feeder pillar box by professional painter with suitable size, height and width complete as specified and dirtected by EIC
Supply only White Lime (Chunna) jodhpuri in rock foam as per specified
S&F Power correction capacitors heavy duty 5 kVAr 440 V Make :- L&T
S&F Power correction capacitors heavy duty 10 kVAr 440 V Make :- L&T
S&F Power correction capacitors heavy duty 15 kVAr 440 V Make :- L&T
S&F Power correction capacitors heavy duty 20 kVAr 440 V Make :- L&T
S&F Power correction capacitors heavy duty 25 kVAr 440 V Make :- L&T
Supply and fix 3 pole Capacitor duty contactors AC3 12A confirms to IS-60947 Make :- MO12 of L&T/equaivated
Supply and fix 3 pole Capacitor duty contactors AC3 18A confirms to IS-60947 Make :- MO18 of L&T/equaivated
Supply and fix 3 pole Capacitor duty contactors AC3 25A confirms to IS-60947 Make :- MO25 of L&T/equaivated
Supply and fix 3 pole Capacitor duty contactors AC3 32A confirms to IS-60947 Make :- MO32 of L&T/equaivated
Supply and fix 3 pole Capacitor duty contactors AC3 40A confirms to IS-60947 Make :- MO40 of L&T/equaivated
Supply and fix fornt mounting Add on auxilary contact blocks of MO type as per existing NO+NC includling 2.5mm copper control cable upto 0.5 meter complete as specified and directed by EIC
Supply and fix Side mounting Add on auxilary contact blocks of MO type as per existing NO+NC includling 2.5mm copper control cable upto 0.5 meter complete as specified and directed by EIC
Supply and fix Spare coil contact MO32 of L&T
Supply and fix Spare coil contact MNX40/MO40 of L&T
Supply and fix Extended Rotary Handle Black colour suitable as per existing size
Supply and fix Electronic timer Type ST100 3-30 Sec for 240/415V 50Hz complete as per sppecified
Supply and fix Handle assembly suitable for 100 to 800A ON/OFF complete as per specified
Supply and fix Extended ROM for MCCB any size as per exisiting pannel complete
Supply and fix Panel door mounted key lock set complete as per specified and dirtected
Supply and fix PVC cable duct size 30x25 one meter long side hinging inside panel
Supply and fix Tear drop Knobs upto 400A suitable as per exisiting complete
Supply and fix LED Indicator lamp (R-Y-B) set of three complte for panel mounting as per specified
Supply and fix Aluminium cable lugs for size Pin/bottle type upto 16 sqmm as per sepcified as dirtected
Supply and fix Aluminium cable lugs for size Pin/bottle type 16sqmm to 35 sqmm as per sepcified as dirtected
Supply and fix Aluminium cable lugs for size Pin/bottle 50 sqmm to 120 sqmm as per sepcified as dirtected
Supply and fix cable gland for different size per site requirement as per sepecified as dirtected by EIC
Re-routing /Re-Laying of Lt cables in trenches or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed of following size Note:-Excavation work paid separately
(a) upto 50 Sqmm 3.5/4 core
(b) 50 Sqmm to120 sqmm 3.5 core
(c) 150sqmm to 240 sqmm 3.5 core
Dismantling of old ACSR conductor from Poles of any size and removal from site.
Supply and Fixing ACSR conductor on poles including stringing and fixing in position and binding to insulators and jumpers, complete all as specified and directed.
Fixing/Stringing only LT overhead line of ACSR conductor of any Size and span not exc. 50 Mtr including binding with aluminium conductor and jumper including trimming/pruning/dressing the tree branches and cleaning or creepers from poles all as directed by Engr-in-charge.
Dismantling and taking down cross arms of MS channel or angle sections, clamps, nut and bolt, washers, back plate of any size/shape complete and removal from site.
Supply and fixing cross arms, bracing supports clamps,ms sheet from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size complete as directed .
M&L for painting with two coats of synthetic enamel paint over a coat of cross arms, bracing supports clamps,ms sheet from structural steel sections including poles complete as directed .
Dismantling old unserviceable stay assembly complete including necessary excavation and demolition of concrete and removal from site.
Supply and fixing stay assembly complete with accessories as shown in electrical plate No. 1 of MES schedule part I with and including 20 mm dia stay rod, stay clamp and galvanized stay strand of size 7/4 mm including necessary clamps, nut, bolts etc
Dismantling of unserviceable insulators of any type/size and Supply and fix shackle type vitreous white, brown or green insulators for working pressure 1100 volt of 90 mm dia and 75 mm height including galvanized mild steel straps of 31x3 mm size 12 mm dia insulator bolts, nuts & washers.
Dismantling of unserviceable insulators of any type/size and Supply and fixing pin type porcelain, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 100 mm height 65 mm dia for 1100 volts grade.
Dismantling of unserviceable insulators of any type/size and Supply and fixing loop type insulators vitreous, porcelain white, brown or green large size with over all dimensions of 90 x 140 mm clearance or hole 25.5 mm.
Dismantling of unserviceable LT bushing of any type/size and removal from site.
Perventive maintance of LT panels/feeder pillar box/Electric meter panel box comprissing of following works to be carried out as under:- (i) Cleaning of panel boards by hand/air blower after switching off main supply.(II) tighting of all electrical termination joints (iii) Dresing of internal control wiring and repairs of minor defects on the spot.
Supply only white soft cotton clothes for cleaning of electrical equipments complete
Supply only CRC spray botttle for cleaning of electrical parts/equipments complete
M & L for replacement of transformer LT bushing in site suitable for 1100 volts grade complete with brass rod, rubber bush washers nuts and cork sheet gasket for the rating 63 to 500 KVA indoor/outdoor transformer complete all as specified and directed
Supply and laying for 12.5 to 40mm Graded stone aggregate in area of installation arround the panel area and substation or as dirtected after cleaning the existing ground surface and removing grass and unorganic particales all as reqd and as directed at site complete all as specified and as directed by Engr-in-Charge
S&F Plasting transparent glass cover plate of 4x4inch size or as per existing suitable for electric meter panel board Top cover complete including four nos screwing complete
Cutting of road, hard standing,PCC 45cmX45 cmmx30cm for laying of cable and making good surface give the shape of as cable trench as per site requirement as per directed by Engr-in-Charge
M&L for repairing of 63 KVA Engine 4 nos of cylinders,arragement , repais of mechnical Class A2 Governor,repais of starter motor ect with accessories complete as per specified and directed by EIC Note:-the following items including in this price . (a) Cyl Head repairs. (b) Piston Ring. (c) 'O'Ring push rod. (d) Fan belt (03 Nos). (e) Gasket.
Dismantling of unserviceable LT pole of any type/size and removal from site.
Supply & install Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and of type 410 SP-31 (9 metres long). Note: Earth work shall be measured & paid separately
Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in copping/collar of poles and foundation of stay assembly etc complete all as specified and directed.
Dismantling of unserviceable LT Panel of any type/size and removal from site.
Supply, Installing,testing and commissioning of LT Panel factory made outdoor type as per latest IS mark with following minimum thickness - Load bearing member/Doors - 2mm, Non-load bearing member/internal partitions - 1.5mm, Glandplate/Base channel-3MM , board floor mounted, dust and vermin proof, 3 phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V and Impulse withstand of 12kV and minimum internal Arc with-stand of 65kA, 500mSec as per latest IS mark, weather proof, with separate hinge door for each compartment with Operating handle & locking arrangement with back door common openable(screwed/Lockable), grouted in PCC 1:2:4 Complete. Painting as per defined 7 Tank process with epoxy powder polymerized at high temperature and aluminium busbar (TPN) suitable for 150A with double compression aluminium cable glands with the following accessories with IP -66 rating :- (a) Incoming - MCCB 125 Amp 4 pole 415 V 18 kA rating (b) Outing - (i) MCCB 63 Amp 4 Pole 415V 18 kA - 02Nos (ii) MCCB 40 Amp 4 Pole 415V 18kA - 02 Nos . (iii) Spare compartment for MCCB - 01 nos . (iv) LED indicating lamps for main supply (R-Y-B)
Anil Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .