Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ACCEPTED |
| 2 | Accepted-Technical COOCHBEHAR 97 RABINDRA NAGAR | COOCHBEHAR | ALIPURDUAR | WEST BENGAL | Accepted-Technical ACCEPTED |
| 3 | Accepted-Technical COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | Accepted-Technical ACCEPTED |
Tender Value
₹4.0 L
EMD Value
₹8,004
Closing Date
27 Jan 2026, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AE/CESD,(PWD)
AE/CESD,(PWD), KHUDIRAM SARANI BY LANE, COOCHBEHAR
WBPWD/AE/CESD/e-NIT-10 of 25-26
2026_WBPWD_982643_1
WBPWD/AE/CESD/e-NIT NO-10/T of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Percentage
15 days
COOCHBEHAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,004
18 Mar 2026
2 Jan 2026
30 Jan 2026
2 Jan 2026
27 Jan 2026
8 Jan 2026
Sub Head--01 Dismantling Dismentling the existing E.I. work by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC
Sub Head---02 Distribution wiring Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) partly in 20mm size PVC rigid conduit 'FR' (Brand approved by EIC) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] (different colour for UPS and non-UPS switch & switch board as per direction of EIC) Av. run 8 mtr
Av. run 10 mtr
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (make Finolex / Havells /KEI) in 20mm/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required as to GS 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 2.5 sqmm + 1 x 1.5sqmm (for computer board, PP) [For existing & power plug board as new power boards will charged from power HTPN only]
2 x 6 sqmm + 1 x 4 sqmm ( from PBDB to LBDBs)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc.including supplying sockets, tapes. as per G S 2.5sqmm
Sub Head---03 VTPNDB,HTPNDB,SPNDB & others Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Make: L&T/ Legrand/ ABB/ SIEMENS/ Schneider] 2+10 way Enclosure
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Legrand, as to GS. 240 V, 40A DP for LBDB
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Make-Legrand, as to GS. 6A - 32A SP MCB for PBDB & LBDB
Sub Head 04 Plug & socket Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (make-Finolex/Havells/KEI) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish as per G S On Board
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S& F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS.
Sub Head--05 Supply of light fittings:- Supply and Delivery of 4 feet Industrial box type single LED tube fitting incl. Supply & Delivery of 1 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Supply and Delivery of 4 feet Industrial box type twin LED tube fitting incl. Supply & Delivery of 2 no. 240V, 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 105 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
Sub Head 06---Fixing of Light Fittings Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Sub Head 07---- Supply of Fan Fittings Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. (Make- Crompton / Usha / Orient/ Polar) [BEE star rated] Sweep Size- 1200 mm (48"), Wattage ≤ 55 Watt, R.PM ≤ 350, Air Delivery ≥ 220 C.M.M
Supply & Delivery of 220V, Single Phase, 50 Hz A.C heavy duty exhaust fan of following sizes having complete metal body. (Make- EPC/ USHA/Orient CROMTON) [BEE star rated] 300 mm (12"), 4 Blade, RPM ≤ 920 , Wattage ≤ 45 Watt, Sound level ≤ 46 dB, Air Displacement (In CFM) ≥ 750
Sub Head 08 Fixing of fan fittings Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting (As per drawing no 475 of PWD specification book---May 1991)
Supply & Fixing Socket type fan regulator (Step type) (Make Anchor) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S.
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12")
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For 30 cm (12") Exhaust fan
Sub Head 09----- Miscelleneous Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG)
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. [For existing down rod & Concealed Switch Box painting]
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :. [For existing down rod & Concealed Switch Box painting] On steel or other metal surface : With super gloss (hi-gloss) -Two coats (with any shade except white)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
cancelled_1.pdf
pdf • 0.45 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 0.69 MB
Tendernotice_3.pdf
PDF • 0.96 MB
BOQ_2397101.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .