| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.6 CrAccepted-AOC 2ND LINE GANDHI NAGAR NEAR KALKI MANDIR BERHAMPUR GANJAM 760001 ODISHA | GANJAM | ODISHA | 760001 | ₹42.6 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L3₹27.8 CrAccepted-AOC | ₹27.8 Cr | L3 | Accepted-AOC L3 bidder matching L1 Price |
| 3 | L2₹78.8 CrRejected-Finance 301 ASHIRWAD PARAS CORPORATE ROAD OPP PRAHLADNAGAR GARDEN SATELLITE AHMEDABAD 380015 | AHMADABAD | GUJARAT | 380015 | ₹78.8 Cr | L2 | Rejected-Finance Not matching the L1 Price |
Tender Value
₹71.7 Cr
EMD Value
₹1.8 Cr
Closing Date
16 Feb 2024, 3:00 pmClosed
D S Das, Joint Director, TREDA
Vigyan Bhawan 2nd floor, Gorkhabasti, Agartala, West Tripura District, Pin - 799006
Design, survey, manufacture, supply, erection, testing, commissioning of Solar Photovoltaic Power Plants including establishment of micro grids on turn-key basis as per DNIeT
2024_TREDA_45663_1
No.F.6(416)/TREDA/4593 dated 04.01.2024
Open Tender
Solar Power Plants
540 days
as per DNIeT
As per DNIeT
8 documents required · 8 mandatory
₹25,000
₹1.8 Cr
Yes
TREDA Head qtrs,Agartala
16 Mar 2024
5 Jan 2024
16 Feb 2024
5 Jan 2024
16 Feb 2024
5 Jan 2024
5 Jan 2024 - 15 Jan 2024
17 Jan 2024
Design, manufacture, supply, erection, testing and commissioning of 2 KWp Solar Photovoltaic Power Plant as per technical specifications of DNIe-T on turn-key basis
Design, manufacture, supply, erection, testing and commissioning of 5 KWp Solar Photovoltaic Power Plant as per technical specifications of DNIe-T on turn-key basis
Design, manufacture, supply, erection, testing and commissioning of 10 KWp Solar Photovoltaic Power Plant as per technical specifications of DNIe-T on turn-key basis
Design, manufacture, supply, erection, testing and commissioning of 15 KWp Solar Photovoltaic Power Plant as per technical specifications of DNIe-T on turn-key basis
Design, manufacture, supply, erection, testing and commissioning of 20 KWp Solar Photovoltaic Power Plant as per technical specifications of DNIe-T on turn-key basis
Design, manufacture, supply, erection, testing and commissioning of 25 KWp Solar Photovoltaic Power Plant as per technical specifications of DNIe-T on turn-key basis
Supplying & drawing of ISI marked heavy duty 1.1 KV grade, twin core multi strand, 6 sq. mm. Aluminium conductor cable (FR), PVC sheath, PVC insulated, extruded type, steel wire armoured cable suitable for power transmission as per relevant ISS for distribution line using GI Pole for domestic connections including supply & fitting, fixing of insulators etc. as required for establishing power distribution network.
Supplying & drawing of ISI marked heavy duty 1.1 KV grade, twin core multi strand, 10 sq. mm. Aluminium conductor cable (FR), PVC sheath, PVC insulated, extruded type, steel wire armoured cable suitable for power transmission as per relevant ISS for distribution line using GI Pole for domestic connections including supply & fitting, fixing of insulators etc. as required for establishing power distribution network.
Supplying & drawing of ISI marked heavy duty 1.1 KV grade,XLPE insulated 3.5 core, 25 sq. mm. Aluminium conductor cable (FR), PVC sheath, PVC insulated, extruded type, steel wire armoured cable suitable for power transmission as per relevent ISS for distribution line using GI Pole for domestic connections including supply & fitting, fixing of insulators etc. as required for establishiong power distribution network.
Supply & Erection of 12 ft. long, 4 inch dia ISI marked GI Pole with 250 mm X 250 mm MS Plate of 10 mm thickness using 4 nos. of T-bolts (SS/GI) of 25 mm thickness and 50 cm length with grouting (1:2:4 - Cement:Sand: Stone aggregate) of minimum 1 ft X 1 ft X 2 ft.
Supply, erection of Pole Mounted Outdoor Type Junction Box (IP 65 enclosure, ISI marked) for service connections
Extension of domestic connection from Pole Junction Box with twin core 2.5 sq. mm. PVC sheathed & insulated conductor cupper cable (FR) (ISI marked) and GI bearing wire & real insulator including fitting fixing of ISI marked 10 KA breaking capacity, B/C curve 1.5 to 2.5 Amps DP MCB in MCB DB at the house of beneficiary
Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
2 way SPN MCB DB (single door):-
Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:-
2 X 1.5 sq. mm
Supplying and drawing 2.5 sq. mm Copper conductor wire along with other wire for loop earthing including connection etc. as required.
Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm PVC insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc. as required:-
SHORT POINT (Upto 3 meters)
MEDIUM POINT ( Above 3 meters to 6 meters)
LONG POINT (Above 6 meters to 10 meters)
Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
Surface mounted integrated 10 watt LED batten with polycarbonate diffuser:-
Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:-
Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser having facility of Multiple Light Level i.e. 5 hours at full light (100% light level), rest of the time at 50% light level and ON/OFF switch in enclosure suitable for outdoor application & including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
12 watt LED street light fixture with integral driver and secondary lens (IP 66):-
Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12"x 12" having locking arrangement including CC work, holes on earth pipe etc. as required.
Extra for using salt (5 kg) and charcoal (46 kg) for pipe earth electrode as required.
Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required.
Providing and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc. as required.
Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-
32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300mmx240mmx80mm):-
63 amps 415 volts four strip Copper busbar chamber 4 ways of size (330mmx280mmx100mm):-
Supplying and installation of Switch disconnector fuse unit (Main Switch) of the following ratings with all accessories including necessary connection etc. as required:-
16 amps 240 volts DP main switch (rewireable):-
32 amps 240 volts DP main switch (rewireable):-
63 amps 415 volts TPN main switch (rewireable):-
Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:-
Construction of Control Room (Minimum 86 sq. ft.) for PCU, Battery, ACDB, DCDB etc.for 2 KWp Power Plant
Construction of Control Room (Minimum 108 sq. ft.) for PCU, Battery, ACDB, DCDB etc. for 5 KWp Power Plant
Construction of Control Room (Minimum 160 sq. ft.) for PCU, Battery, ACDB, DCDB etc. for 10 KWp Power Plant
Construction of Control Room (Minimum 215 sq. ft.) for PCU, Battery, ACDB, DCDB etc. for 15 KWp Plant
Construction of Control Room (Minimum 270 sq. ft.) for PCU, Battery, ACDB, DCDB etc. for 20 KWp Plant
Construction of Control Room (Minimum 323 sq. ft.) for PCU, Battery, ACDB, DCDB etc. for 25 KWp Plant
SAHAJ SOLAR LIMITED
TECHSUNBIO GREEN ENERGY PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid