Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L1 | Accepted-AOC accept | |
| 2 | L2₹24.0 L+₹1.3 L (5.76%)Rejected-AOC | L2 | Rejected-AOC accept | |
| 3 | L3₹25.1 L+₹2.4 L (10.6%)Rejected-AOC R O SUJANPUR TEHSIL DISTT HAMRIPUR | L3 | Rejected-AOC accept |
Tender Value
₹15.9 L
EMD Value
₹31,300
Closing Date
9 Mar 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
Providing LWSS to PC habitation Under ( Jal Jeevan Mission ) in GP Bhoura, Thandol and Malahoo in Tehsil Palampur Distt Kangra.( H.P.)
2021_HPIPH_45056_1
THL-KNG05-729 (19985-20025 dated 03.03.2021
Open Tender
Civil Works - Water Works
Item Wise
180 days
Providing LWSS to PC habitation Under ( Jal Jeeva
Please refer Tender documents.
10 documents required · 10 mandatory
₹400
₹31,300
Yes
15 Dec 2021
3 Mar 2021
10 Mar 2021
3 Mar 2021
9 Mar 2021
3 Mar 2021
120 days
Amount
Excavation in foundations and trenches(for pipes and pits in all depths etc.) in all lifts and in all kinds of soils such as pick work, jumper work, blasting in soft/hard rock, chiseling/wedging out of rock (where blasting is prohibited)and saturated soils, stacking the excavated earth within all leads and lifts, clear from the edge of excavation and then returning the stacked soil in 15 cms. layers when required into plinths, sides of foundation and trenches etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed by Engineer-in-charge within all leads and lifts including uprooting of trees, dressing of beds and sides and preparation of sub-grade, restoration of unmetalled/metalled/paved surfaces to its original conditions including soring, strutting, timbering and dewatering , where ever required, providing diversion for traffic, fixing night signals, fixing caution boards, crossing over trenches for access to houses complete and to the entire satisfaction of the Engineer-in-charge.
Laying, jointing steel flanged pipes after every pipe of following diametr .Conforming to IS 1239-1990 (Part-II), having wall thickness as specified below capable of withstanding required test pressure, including manufacturing and febrication of reducers/ tapers , all short pieces, etc. as per site requirement made from parent tubes . The laying of pipe shall also include flanged joints duly welded in three layers (Two inner & one outer), where ever required as per direction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately) and all operations such as cutting, welding, jointing, fabrication of tees i.e. lowering and laying in excavated trench to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the entire satisfaction of the Engineer in charge. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The damaged portion of the pipes and all the specials ( If damaged during laying & jointing operation of pipe) made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing, welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts.
1st Tube Well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-5) outer dia 89.50 mm , at every 6 mtr pipe flanged from RD 0 to 800 = 800 Rmt
2nd Tube well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-17) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 0 to 80 = 80 Rmt
2nd Tube well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-17) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 80 to 550 = 470 Rmt
2nd Tube well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-17) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 550 to 1300 = 750 Rmt
Providing MS flanges (In pairs) for the joints of G.I. pipes mentioned as below and same shall conform to BIS 6392-1971 ( latest with up to date amendments) including the cost of nuts and bolts of required sizes, 3mm thick compressed asbestos fiber/synthetic rubber gaskets conforming to relevant BIS standards and it shall also include carriage of materials within all leads and lifts complete in all respect to the best satisfaction and direction of Engineer in charge.
1st Tube Well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-5) outer dia 89.50 mm , at every 6 mtr pipe flanged from RD 0 to 800 = 800 Rmt/6=133 Nos
2nd Tube well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-17) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 0 to 80 = 80 Rmt/6=13 Nos
2nd Tube well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-17) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 80 to 550 = 470 Rmt / 6 =78 Nos
2nd Tube well G.I. ( M. Class) pipe 80mm dia with wall thickness 4.00 mm of , (FT-5) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 550 to 1300 = 750 Rmt /6 =125 Nos
1st - Tube Well,Supply of submersible pumping set of (KSB /Kalama/Kirloskar/Johnston/Cromption/BS) make conforming to BIS; 8034-1976 latest suitable for lifting clear water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head,75.98 Mtrs,Discharge required from each pump.,2.58 LPS for each pump ( One Will act as stand by),No. of pump required,2.00 Nos. One act as stand by,Location of the site of installation of machinery.The site is located at a distance of 12 Kmts from Palampur.The Altitude of installation.The altitude of place is 700 mtrs above MSL,Type of current.AC Three phase supply with,Rate Voltage, 415+ 10%,Type of water and its source,T/Well,Charactristics of water.a)Ambient Temperature dig.c,20 dig. C,b)Turbidity NTU, NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,Depth of S/Well,80 mtrs,LWL in S/ well,mtrs.,Dia of Bore,Maz draw down,Static water level in S/Well, mtrs,Center line level of Pump ,877.52 mtrs,Discharge level of highest point,947.52 mtrs,Static head in Mrs,70 mtrs.,Length of R/Main (Including Column Assembly),800 mtrs.,Dia of Rising main,80 MM,No of working hours per day,16 Hours,Limit of pump operation.(-) 15 % (+) 10% of total head,R.P.M. of pumping set.,2900 RPM ( or to be specified by the tenderer),Test run.8 Hours continueously for 7 days
Supply , installation, testing and commissioning of PLC (Programmable Logic Controller) based Fully Automatic LT Panel for submeresible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump automatically as per site requirement along with sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirement through PCL panel (CPRI approved , with 50 KA Short Circuit and IP-55 protection duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4 mm at bottom inside panel 1 No. board with two earth tereminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in gray colour all as spcified & directed, Make of panel board : dvepl / aspl / tricolite. The pannel board should also have following items ( i to xviii).
PLC (Programmable Logic Controller),1.00 Nos
ICTP switch with HRC fuses L&T / Standard / Havells make & having capacity 30 % extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.1.00 Nos
MCB /MCCB suitable capacity of Schneider/Siemens/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.1.00 Nos
Y-D starter of suitable capacity for submersible pump Make - L&T / ABB/ Schneider.1.00 Nos
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.1.00 Set
Star delta timer.1.00 Nos
Single phase parventer of reputed make Minillic / L & T / Standard & Suitable capacity.1.00 Nos
Automatic Phase Sequnce Corrector with prevention against, phase revarsal protection, under / over load protection Make ABB/ L&T / Siemens/GIC.1.00 Nos
Control MCB 6A -SP.1.00 Nos
On / Off indicator and push button. Set of 1 each
Control and power wiring.LS
Power capacitor of suitable capacity.1.00 Nos
Control terminal, Bus Bar, i.e.Bolt, insulator, etc.LS
LED 5 Watt.1.00 Nos
Cooling fan 230 VAC.1.00 Nos
Hour run Meter.1.00 Nos
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast Iron double flanged sluice valve 80 mm dia class PN1.6 confirming to BIS-780-1984 (to be provided on R/main side) capable of with standing nominal seat test pressure of 16 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast Iron double flanged swing check type reflux valve 80 dia class PN 1.6 vconfirming to BS 5312-1984 having bye pass arrangement (to be provided on R/main side) and shall be suitable for withstanding nominal seat pressure of 16 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 2.5 mm^2 ( From HPSEB Meter to Switch &Starter).
On motor side 3 core flat joint less copper cable of size 2.5 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses.
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1979 latest with up to date ammendments.
P/Laying Column assembly of G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. Column assembly =80 mm dia G.I.flanged pipe(medium grade) NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
2nd Tube Well, Supply of submersible pumping set of (KSB /Kalama/Kirloskar/Johnston/Cromption/BS) make conforming to BIS; 8034-1976 latest suitable for lifting clear water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head,207.35 Mtrs,Discharge required from each pump.2.40 LPS for each pump ( One Will act as stand by),No. of pump required,2.00 Nos. One act as stand by,Location of the site of installation of machinery.,The site is located at a distance of 12 Kmts from Palampur.,The Altitude of installation.The altitude of place is 700 mtrs above MSL,Type of current.AC Three phase supply with,Rate Voltage,415+ 10%,Type of water and its source,T/Well,Charactristics of water.,a)Ambient Temperature dig.c,20 dig. C,b)Turbidity NTU, NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,Depth of S/Well,80 mtrs,LWL in S/ well, mtrs.,Dia of Bore,Maz draw down,Static water level in S/Well, mtrs,Center line level of Pump ,790.45 mtrs,Discharge level of highest point,974.40 mtrs,Static head in Mrs,183.95 mtrs.Length of R/Main (Including Column Assembly),1300 mtrs.Dia of Rising main,80 MM,No of working hours per day,16 Hours,Limit of pump operation.,(-) 15 % (+) 10% of total head,R.P.M. of pumping set.2900 RPM ( or to be specified by the tenderer)Test run.8 Hours continueously for 7 days
Supply , installation, testing and commissioning of PLC (Programmable Logic Controller) based Fully Automatic LT Panel for submeresible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump automatically as per site requirement along with sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirement through PCL panel (CPRI approved , with 50 KA Short Circuit and IP-55 protection duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4 mm at bottom inside panel 1 No. board with two earth tereminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in gray colour all as spcified & directed, Make of panel board : dvepl / aspl / tricolite. The pannel board should also have following items ( i to xviii).
PLC (Programmable Logic Controller)1.00 Nos
ICTP switch with HRC fuses L&T / Standard / Havells make & having capacity 30 % extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.1.00 Nos
MCB /MCCB suitable capacity of Schneider/Siemens/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.1.00 Nos
Y-D starter of suitable capacity for submersible pump Make - L&T / ABB/ Schneider.1.00 Nos
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.1 set
Star delta timer.1.00 Nos
Single phase parventer of reputed make Minillic / L & T / Standard & Suitable capacity.1.00 Nos
Automatic Phase Sequnce Corrector with prevention against, phase revarsal protection, under / over load protection Make ABB/ L&T / Siemens/GIC.1.00 Nos
Control MCB 6A -SP.1.00 Nos
On / Off indicator and push button.Set of 1 each
Control and power wiring.LS
Power capacitor of suitable capacity.1.00 Nos
Control terminal, Bus Bar, i.e.Bolt, insulator, etc.LS
LED 5 Watt.1.00 Nos
Cooling fan 230 VAC.1.00 Nos
Hour run Meter.1.00 Nos
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Steel Iron double flanged sluice valve 80 mm dia class ASA-150 confirming to BIS-1414 (to be provided on R/main side) capable of with standing nominal seat test pressure of 21 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast Iron double flanged swing check type reflux valve 80 dia class ASA150 vconfirming to BS 1868 having bye pass arrangement (to be provided on R/main side) and shall be suitable for withstanding nominal seat pressure of 21 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 4.00 mm^2 ( From HPSEB Meter to Switch &Starter).
On motor side 3 core flat joint less copper cable of size 2.5 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses.
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1979 latest with up to date ammendments.
P/Laying Column assembly of G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. Column assembly =80 mm dia G.I.flanged pipe(medium grade) NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Sanjeev
RAJE ENGINNERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .