Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.1 L+₹73,238.70 (4.78%)Rejected-AOC A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L2 | Rejected-AOC L2 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
18 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 871 EWS
JOSHIMATH-246443
COMPREHENSIVE MAINTENANCE OF MISC EM SERVICES TO ELECTRICAL NETWORK SYSTEM, ZONE-III AT JOSHIMATH UNDER GE 871 EWS
2021_MES_444812_1
8592/E8
Open Tender
Electrical and Maintenance Works
Works
270 days
JOSHIMATH
REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 871 EWS
₹32,000
Yes
19 Jul 2021
21 May 2021
21 Jun 2021
21 May 2021
18 Jun 2021
4 Jun 2021
21 May 2021 - 3 Jun 2021
60 days
Amount
Excavation in trenches n exc 1.5 metre wide and nexc 1.5 metre depth getting out in hard dense soil all as specified and directed.
Excavation in trenches nexc 1.5 metre wide but depth exc 1.5 metre but nexc 3.0 metre foundation and getting out in soft disintegrated rock all as specified and directed.
Excavation in trenches nexc 1.5 metre wide and nexc 1.5 metre depth and getting out in soft disintegrated rock all as specified and directed.
M&L for making good the disturbed surface by filling PCC 1:2:4 type B-1 using 20 mm graded course aggregate to match with existing surfaces all as specified and directed.
Removing of excavated soil to a distance nexc 50 metre and deposited where directed at a level not exc 1.5 metre above the starting point all as specified and directed.
Returning and filling in including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick using excavated soil all as specified and directed
Removing excavated soil to a distance nexc 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
M&L local sand dry, filling in trenches around under ground cable all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured.
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable all as specified and directed.
M&L PCC (1:4:8) type D-2 (using 40 mm graded course stone aggregate) lean concrete below foundation of steel tubular poles including necessary form work for fair finished surfaces of concrete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete including necessary form work for fair finished exposed surfaces of concrete all as specified and directed at site.
M&L PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work for fair finished exposed surfaces of concrete all as specified and directed.
Supply and fixing in repairs, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 120 sqmm 3.5 core all as specified & directed. Make: Havells/Polycab/Finolex/Universal/Mescab
All as per Item No 13 here-in-before but of size 50 sqmm 3.5 core
All as per Item No 13 here-in-before but of size 25 Sqmm 4 core
All as per Item No 13 here-in-before but of size 16 Sqmm 4 core
All as per Item No 13 here-in-before but of size 10 Sqmm 2 core
Supply and fix in repairs light grade galvanised mild steel pipe 80mm bore with all fittings, laid under road crossing, drain, paths, fixed to poles/ walls with suitable mild steel clamps, bolts, nuts and washers all as specified and directed as for cable protection all as specified & directed. Make :- Jindal/TATA/Prakash surya Note:- Excavation & earth work shall be measured and paid for separately under respective items of this schedule.
All as per Item No 18 here-in-before but of size 40 mm bore
Supply and fix in replacement of 1100 volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor all as specified and directed. Make: Havells/Polycab/Finolex.
Supply and fix in repairs 1100 volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size aluminum conductor 10 sq mm stranded conductor all as specified and directed. Make: Havells/Polycab/Finolex.
Supply and fix in repairs 1100 volts grade heavy duty cable PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size of aluminum conductor 16 sq mm stranded conductor all as specified and directed. Make : Havells/Polycab/Finolex.
Supplying, errecting and fixing in repairs of steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type/size all as specified and directed. Make : India Co. Ltd Jamshedpur/Fabrico(India) Pvt Ltd Meerut/National Tubing Co. Kanpur Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under respective items of this schedule.
Supply and fix in repairs, commissioning of street light fitting 48 watt LED, endura pearl neo new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 including 1.60 metres. long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts, nuts & washers and XLPE Cable to fitting all as specified and directed. Make:- Havells cat part No. ENDURAPEARLNEOSL48WLED757PASYTOPC or equivalent of Phillips/Bajaj Note :-Rates quated by contractor are deemed to be inclusive of pvc heavy duty conduit along with 3 run of 1.5 sqmm pvc insulated unsheathed copper multistranded conductor ISI marked from MCB box to street light all as specified.
Supply and fix in repairs, commissioning from existing poles/buildings of any height/type of new LED flood light fitting 100 watt JETA IRIS energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting etc complete fixed bracket made out by GI pipe (light grade) of suitable size and MS clamp and nut bolts washers etc complete and connected with twin core cable 4 sqmm from flood light to fittings connector all as specified and directed. Make:- Havells cat part No JETAIRISFLS100WLED757SYMLTG or equivalent of Philips/Bajaj
Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia TMT bars @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar, including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge. NOTE :- GI earth wire and protection pipe beyond 7.5 metres will be measured and paid separately.
Lopping/prooning of tree branches upto the extend to obtain clearance all around the LT over head lines/ HT over head lines conductor upto 3 metres from furthest conductor on pole including removing of cut branches and cleaning of site all as specified and directed. Note :- (a) The trees branches etc will be left as it is and will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO and they will be responsible to lift the wood. (b) Prooning of all tree branches up to 6 inches girth in one tree shall be measured as one Job. (c) Contractor will employ sufficient labour to complete the job with in time as directed. (d) Contractor will be responsible for any type of mis-happening/accident while prooning the trees. (e) Contractors supervisor will take proper shut down from MES installation before starting the work and clear it before resuming power supply . However full assistance will be provided by MES staff. (f) The contractor will provide proper tools and safety devices to his staff for prooning of trees.
M&L for Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length(if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified and directed. Note:- (a) Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) . (b) Five lines together will be measured as one span from pole to pole.
M&L for painting to poles (9/11 metre long) including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5metre height complete, spray painting with two coats of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing, etc.all as specified and directed
Supply, fixing in replacement, connecting and testing MCCBs in existing LT panel box/feeder pillar boxes (KIOSK) of capacity 160 Amps 4 pole breaking capacity 25 KA with thermal as well as magnetic balance adjustable type all as specified and directed. Make : L&T/SCHNEIDER/LEGRAND
All as per Item No 30 here in before but 63 Amps and 16 KA. Make : L&T/SCHNEIDER/LEGRAND
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, 20mm graded crushed stone aggregate of size 600X600X300mm including form work and plastering and two coat of white wash all as specified and directed.
M&L in replacement of earthing complete with using galvanized mild steel earth plate (electrode) 600 mmx 600 mmx 6 mm thick buried directly in ground, earth pit not less than 2.25 metre deep below ground level with top edge of the earth plate not less than 1.50 metre below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all round the plate using 32X6 mm GI earth strip as earth lead moulded and riveted to earth plate at one end and connected to main equipment at switch/control board at another end, GI earth lead incased in and including 40 mm dia GI ‘light grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘light grade’ as water pipe from earth chamber to upper edge of the earth plate, GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded crushed stone aggregate) as in pits chamber and RCC pit cover 50 mm thick of precast RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate)duly reinforced with mild steel round bars 6 mm dia @ 150 mm c/c both ways with 10 mm dia mild steel bars as in lifting handles with and including necessary excavation & earth work including laying the GI pipe concealed in floor/wall all as per plate No. 3 of SSR Part I complete all as specified and directed and testing on completion. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
S&F in repairs pole box size 400 x 250 x 150 mm fabricated out of 2 mm thick MS Sheet having 4 Nos aluminium busbar of suitable size with 1 No. MCB SP 6 Amps front openable hinged cover outdoor type weather proof suitable for mounting on steel pole including fixing MS clamp 02 Nos with nuts, bolts and washers all as specified and directed. Make : HPL, C&S, Gaurav
M&L for applying one coat of synthetic enamel paint including preparation of surfaces on iron gate, rolling shutter, LT panel, capacitor panel and change over switches all as specified and directed.
M&L for LT End joint kit for 120 Sqmm size including dismentling of existing complete all as specified and directed. Make : Raychem/Birla-3M/Perreli/Denson
Supply and fix in repair stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm, galvanized thimbles, G.I. stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 on ser Page No.19-47 of MES Schedule Part-I all as specified and directed. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately.
M&L in repairs of broken earth pit of size 350x350x350 mm made of PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site with testing result. complete all as specified and directed.
Supply and fix in repairs old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 50 sqmm including necessary connection all as specified and directed. Make : Axis/Dowells/Indiana
All as per item No 41 above but aluminium lugs of size 70 to 120 Sq mm. Make : Axis/Dowells/Indiana
S&F in repairs aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified and directed.
S&F in repairs galvanized iron strip 32 x 6 mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground /drawn into hume pipe. NOTE : Excavation & earth work shall be measured and paid for seperately under relevant item of schedule all as specified and directed.
S&F in repairs second class hard wood wooden block of size 15x15x15 cm with hole of 8 cm depth & suitable dia for fixing of air termination rod of any size all as specified and directed.
S&F in repairs GI tubes light grade, galvanised iron, 20mm bore including necessary GI fittings, laid in trenches or under floor or fixed with poles/walls for fixing of air termination all as specified and directed.
Supply and fix in repairs single pointed air termination aluminium rod 12mm dia, 300 mm long all as specified and directed.
S&F in repairs of test point terminal block made of gun metal or phosphorous bronze 75x75x25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90x90x90mm made of 1.6mm plain sheet and screwed to wall for protection of test point all as specified and directed.
S&F in repairs cable seperator heavy duty made of plastic with PVC clamps heavy duty three phase separator all as specified and directed.
S&F in repairs cable seperator heavy duty made of plastic with PVC clamps heavy duty two phase separator all as specified and directed.
S&F in repairs ACSR conductor of size 6/1 x 2.59 (Weasel) and 6/1 x 2.11 (Squirrel) ISI marked for LT over head lines on poles including stretching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor all as specified and directed by Engineer-in-Charge.
S&F in repairs cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4 mm dia all as specified and directed.
S&F in repairs mild steel cross arms, bracings, supports, clamps, and back plates fabricated from structural steel sections as ordered including necessory nuts, bolts, washers , welding, bending, cold or hot , drilling holes for bolts , in any shape or size as indicated or directed with and including preparations of new steel surfaces & applying two coats of aluminium paint over one coat of red oxide Zinc chrome primer all as specified and directed.
M&L 100 mm thick PCC 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) including finishing the surface even and fair all as specified and as directed
S&F in repairs mild steel work in framed work such as gates, grills, framed guard bars, gratings, ladders, MS clamp for supporting of cable etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work all as specified and directed
Amit Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .