Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC 7 1 532 1 MILANGARH ROAD SHYAMNAGAR NORTH 24 PGS WEST BENGAL | SHYAMNAGAR | NORTH 24 PARGANAS | WEST BENGAL | 7432127 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.8 L+₹35,654 (5.53%)Rejected-Finance P O SASINDA VILL KASHIYA P S BELDA WEST MEDINIPUR PIN 721445 | BELDA | PASCHIM MEDINIPUR | WEST BENGAL | 721445 | L2 | Rejected-Finance L2 | |
| 3 | L3₹7.0 L+₹54,048 (8.38%)Rejected-Finance 6201 M G ROAD KOLKATA 700 009 | KOLKATA | KOLKATA | WEST BENGAL | 700009 | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.4 L+₹90,760 (14.1%)Rejected-Finance NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹18,592
Closing Date
3 Jun 2025, 11:00 amClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
AMC of EI of whole electrical system ARDD Gr. Floor to 4th Floor Salt Lake Kolkata-106 Supply and installation of drainage water system of different type AC machines and repairing, replacement and fabrication work of M.S platform of AC machines.
2025_WBPWD_853038_1
WBPWD/EE/BED/e-NIQ-19/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Animal Resources Development Departmen
Please refer Tender documents.
5 documents required · 5 mandatory
₹18,592
16 Jun 2025
27 May 2025
5 Jun 2025
27 May 2025
3 Jun 2025
27 May 2025
Amount
Dismantling of existing outdoor units & Angle Iron Frame for 1.5/2.0 ton A.C machines with own tool & tackles as per direction of EIC.
Supply & Fixing of MS Angle Iron Frame with 6 nos Heavy Duty Anchor Bolt Fasteners as required for holding 1.5/2.0 ton AC outdoor unit as per direction of EIC.
Refixing of existing 1.5/2.0 ton A.C machines outdoor units at newly installed Angle Iron Frame with own tool & tackles as per direction of EIC.
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping Split AC system, complete with fittings and including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. (i) 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes (As per standard 85864 or ANSIB 16.22) incl. 19 mm thick insulation.
(ii) 5/ 8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) mm incl. 19 mm thick insulation.
Supply & Laying PVC Drain Pipe 25mm dia with 6mm thick nitrile rubber insulation (Make-supreme / Ori-Plast)
Charges for dismantling of damaged copper pipeline after complition of civil work as per direction of EIC.
Charges for dressing and proper arrangement of copper pipe after complition of AC machine of different floor as per direction of EIC.
Charges for insulation of copper pipe with elastometric nitrile rubber tubular sleeves section and wripping the same as per direction of EIC.
S & F 1.1 KV grade, PVC insulated & unsheathed 3 Core 2.5 Sqmm Copper flexible Cable for Socket to Indoor & Indoor to outdoor connection as per direction of EIC.
Supplying, fifting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to lS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fiftings as required, jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class -I, SDR-11 (Dia) 40 mm.
(iii) 25 mm
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer- incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. lf necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly.' (a) 3.9 meter height
(b) Extra for additional 3.6 height or part thereof
S & Charging Refrigerent R32 Gas as per direction of EIC.
S & Charging Refrigerent R410A Gas as per direction of EIC.
Repair and replacement of damaged part of MS grill guard and platform and painting of 5’x4’ (3 side Railing) in size MS Platform made by M.S. Channel,angel & flats with (approx 3”) square gapping for the installation of outdoor Unit of split type A.C. Machine.The Platform are made with M.S Channel of size -75x75x8 mm for support of both side 7 middle of the platform also the channel are partly painting and placing inside the wall. The platform constructed by M.S. angel iron frame of by 50x50x6mm in required size incl. 8 nos. support cross wise form wall to frame for proper resting the platform. More over to complete the Platform by proper placing & by M.S. flat of size -19x6 mm with 3” square gapping (approx) over M.S. angel iron frame with & and 3 side grilling arrangement by angel frsme etc. Proper painting the platform by two coats of after proper scraping byb emery paper for smooth finish as per requirement & direction of E.I.C.
Painting of any steel/ iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint as to GS. A) One coat of red lead/Zinc chromate priming. B) 1st coat of aluminium paint over one coat of RO priming C) 2nd coat of aluminium paint over 1st coat
Supply and fixing of 35/36 watt system wattage 6500 K colour Temperature, cool day light colour, recessed mounted IP 20 LED 2ft X 2ft luminaries having > 3050 lm system output. Luminary shall be made up of CRCA epoxy polyester powder coated housing. Luminaries shall have optical grade High Efficiency Translucent Optical component for very high efficiency with minimum glare.Driver output voltage shall be less than SELV limits for safe DC operation and maintenance. The Driver should be fully designed and manufacture in India. The fittings should be fixed in false ceiling by hanging with chain / spring and fastner and as required for proper fixing with the actual ceiling and complete with all accessories having following Model/Cat No.- Philips RC380B LED42S- 6500 G6 L60W60 PSU OD S1/ Wipro CRCO1ORO3OHP57G3 /As per choice of EIC
Supply & Deiivery of LED street light luminarie IP 66,made up of pressure die cast aluminium housing witJl Toughened glass/ PC cover provided with high power LEDs and secondary optics PC/PIvIMA lens and Silicon filled BIS registered Potted Vibration proof Driver with built in 4 KV surge protection and 1OKV extemal SPD with Efficacy>120 lumen/watt, CRI >70, CCT> 5700K. Make:- Wipro DOT/Crompton, Raptor Pro/ Bajaj,EDGE NXT LED/ PANASONIC BLOOM /Havells Endura SunDown/PHILIPS Urban edge PIus) Driver Mk.- Philips Signify/Wipro / Xitanium/ Inventronics. LED Chip mk.-Nichia,Cree,Osram, Lumiled. A) 90-100 Watt
Less Cost dismantle materials :
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
BARSHA ENTERPRISE (BID ID -6498437)
SUMAN ENTERPRISE (BID ID -6468189)
ANIKET COOLING AND REFRIGERATION CO (BID ID -6480862)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .