Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.2 LAccepted-AOC | 1 | Accepted-AOC 1st | |
| 2 | 2₹15.2 L+₹915.77 (0.06%)Rejected-AOC COLLEGE PARA BALURGHAT DAKSHIN DINAJPUR | BALURGHAT | DAKSHIN DINAJPUR | WEST BENGAL | 2 | Rejected-AOC 2nd | |
| 3 | 3₹15.3 L+₹5,494.63 (0.36%)Rejected-AOC | 3 | Rejected-AOC 3rd |
Tender Value
₹15.3 L
EMD Value
₹31,000
Closing Date
11 Mar 2026, 5:00 pmClosed
Chairman, Balurghat Municipality
Sova Majumder Sarani, Balurghat, D/Dinajpur
Construction of Room for Cloth Bank including Internal electrification within Balurghat Municipality
2026_MAD_1012858_1
MAD/ULB/BLGT/PW/23/25-26
Open Tender
CIVIL WORKS
Percentage
90 days
Balurghat Municipality
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹31,000
Yes
19 Jun 2026
23 Feb 2026
14 Mar 2026
24 Feb 2026
11 Mar 2026
25 Feb 2026
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. (a) upto 150 mm. thick
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete.( Payment to be made on the basis of measurement of finished quantity of work ).
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches
Cement concrete with graded stone ballast (40 mm size excluding shuttering) (a) 1:3:6 proportion
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint asper item 8 (a) of subhead C of Section (C).
Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) Pakur Variety
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, omplete as per drawing and direction. (JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL) (a) For works in foundation and upto roof of ground floor/upto 4 m
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (f) 25 mm to 30 mm shuttering without staging in foundation
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (i) With 1:6 cement mortar (b) 15 mm thick plaster
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing 10 kg/sq m to16 kg/m2. In Ground Floor
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats.In Ground Floor
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats.In Ground Floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss)-With any shade except white.
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).a) In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making acessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. P.W.D. /S& P/ P-89/It. No-4/(7th Corrigenda)
Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989/ 2009 and I.S. 1729/2002 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will however be paid seperately). (ii) 100 mm dia. (internal)
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm(depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Bazree (N.B Variety) (Other manufacturerer not specified)
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes a) For Exposed Work 20 MM DIA
32 MM DIA
(b) For Concealed Work 15 mm Dia
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. markng with fittings(tested to 21 kg/sq.cm.). 20 MM DIA
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) – (Multilayer) 1(a) 500 litre capacity
Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L.
Labour for punching hole in plastic water storage tank upto 50 mm dia.
Cutting hole through wall,roof or cornice and mending good all damages.
Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore. (a) For depth upto 150 metre.(i) 40 mm dia. boring etc. (49/1 )
Supplying PVC strainer of approved make with adapter conforming to I.S.12818specifications.(i)40mm dia. (51/4 )
Supplying, fitting and fixing plug of approved make conforming to I.S. specifications. (i) 40 mm ( 102/1)
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes (Dia) 40 mm ( 49/10 )
Supply and fixing polythene pipe complete with fittings as necy. Under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beem casting work of building construction) (PWD Elec. Sch Nov 2017, P No-E-2, (B) It no.- 1) (b) 19mm dia 3mm thick Polythene Pipe
Cutting Channel of 40mmX40mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below by means of iron hooks and supplying and drawing 18 SWG GI wire as fish wire incl. mending good damages to building works. (PWD Elec. Sch Nov 2017, P No-E-2, (B) It no.- 3) (b) 19 mm dia 3 mm thick polythene pipe with 1X14 SWG GI earth continuity.
Supplying and drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. Connection as required (PWD Elec. Sch Nov 2017, P No-E-9, (C ) It no.- 1) (s) 2x36/0.3 (2.5 sqmm) + 2x22/0.3 (1.5 sqmm) ECC
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and and ceiling portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. (PWD Elec. Sch Nov 2017, P No-E-20, (G) It no.- 2) (ii)) (i) Average run 7 mtr
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. (PWD Elec. Sch Nov 2017, P No-E-20, (G) It no.- 3) (i)) (i) On Board. (PWD Elec. Sch Nov 2017, P No-E-20, (G) It no.- 3) (i))
(v) Average run 6 mtr. (PWD Elec. Sch Nov 2017, P No-E-20, (G) It no.- 3) (v))
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [PWD Schedule Page E-18, Item no. 9 (b)]
Supply & Fixing 240V, Modular socket (2 Module) type fan regulator ( step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. Making necy. Connections etc. [PWD Schedule Page E-18, Item no. 10]
Supply & delivery of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts. Size: 1200 mm [I & WD . P-115, 5.3.G.1.1]
Fixing only ceilling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connections as required by 2 x 1.5 sq.mm flexible copper wire. [PWD Schedule Page C-3, Item no. 21(a)]
Supply and fixing of philips Smartbrite Xtra 4ft run length LED Batten Tube light, incl Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm día El conduit (14 SWG) supports incl. S&F El conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length [I & WD . P-110, 5.3 F.4.0.2] Crompto Make : 18 Wt.
Supply of 20 W LED Lamp, (Philips make, Base B22/B27, 2000 LM) (WB I & WD schedule P-114, I- 5:3 F.28.1)
Fixing only 20 W LED Lamp [PWD Schedule Page C-2, Item no. 11]. (PWD sch - Page-C-2, Item No.-11)
Supplying & fixing sheet steel Main switches on angle iron frame on wall 100/125 A 415V TPN with fuse on L&N (Havells make) [PWD Schedule Page D-1, Item no. 1 (b)]
Supply & fixing 415 V, 125A TPN on load front operated Changeover switch with sheet steel enclosure on angle iron frame on wall with nuts bolts etc. (Havells make) [PWD Schedule Page D-2, Item no. 3 (a)]
Supply & fixing 415V, 125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S&F 3 ns. DIN type HRC fuse as per rating. (Havells make) [PWD Schedule Page D-3, Item no. 4 (a)]
Suuply & Fixing sheet steel metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachmenmt and painting as required- (As per Drawing no. 470 of PWD Specification Book May- 1991) 4 bars. 415V, 100/125A. Dimension of Al. Bars [ 85 mm long]- 4x25x5 mm; Dimension of Sheet Metal Box - 500x150mm. [PWD Schedule Page D-12, Item no. 19 (a)]
Supplying and fixing double-door Vertical TPN MCB Distribution Board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Up to 160 A 12 Way Enclosure (607915) Legrad make. [PWD Schedule Page D-11, Item no.15]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32A SP MCB (Make -Havells) [PWD Schedule Page No-D-6;Iteam No-7]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. (2 Way) (PWD sch - Page-D-9, Item No.-11)
Supply & fixing 240/415 V MCB isolator on din rail of existing DBs and necessary connection 63A DP. (Legrand make) [PWD Schedule Page D-5, Item no.6]
Supply,delivaryof 1.1KV grade 4 Core x10 sq.mm XLPE Insulated PVC sheathed Al armoured Cable (Polycab/ Gloster/Havells) as per IS- 7098 (UDMA Page-11, Item no. 1.c)/3)
Supplying and fixing compression type gland complete withbrass gland, brass ring & rubberring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: 4core10 sqmm cable PWD Sch Page-F-4;Item-7 [c]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials (xi) 4 core 10 sqmmcable PWDSchPage-F-5;Item-8(b)
Earthing with 50 mm dia G.I. pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI(Hot dip) wire (4 Mts. Long), 13mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe [PWD Schedule Page G-1, Item no.2(a)]
Fixing only flood light fitting with suitable tie clamps and M.s. Plate for mounting on pole/tower or similar structure PWD Schedule Page No C-3 / Item No. 20(a)
Supply,delivery of LED Foodlight luminaire with secondary optics made in pressure die-cast housing and heat sink in aluminium extrusion with IP 66 & minimum output of 11000 lumen;Max wattage of 120watt. [BVP 192 LED 110 CW HONB FG GR PSU] (Philips/Bajaj/Havells) Ref: Letter under memo no. ME/277/1G-26/17 Pt, IV dt.23.05.2023. (Sl. No. 03)
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. 3 core 6 sq.mm. [I & WD . P-101, 5.3.A1]
Supply & installation water pump 220/240 V. 1 H.P. residential water pump self-priming single phase , high suction capacity , wide voltage range, line connection etc. complete set. (Crompton/KSB make ) UDMA Pg-44;34
Supply, Delivery and installation of Co2 type fire extinguishers: HSN code-84241000 4.5 Kg capacity with ISI marked Co2 type fire extinguisher squeeze grip type conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief controller of explosive, Nagpur, fitted with ISI marked controller of explosive, Nagpur, fittet with ISI marked controlled valve conforming to IS:3224, high pressure 1 mtr. long discharge hose and horn complete with initial gas charged with carrying handle and wall mounting bracket suitable for operating between (-)30ºC to (+)55ºC. Fire rating -13B. [UDMA Pg-24;78 (C )]
Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 300 mm sweep RPM 1400 (12") [I & WD . P-115, 5.3.G.5.3]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: (b) 30 cm (12") [PWD Schedule Page C-4, Item no. 28]
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) (b) For 30 cm (12") Exhaust fan [PWD Schedule Page C-4, Item no. 30]
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR UNARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. 2 core 6 sq.mm. [I & WD . P-101, 5.3.A1]
Supply, Delivery and installation of IFB 9 kg Washer with Dryer AI Powered, 30 min Steam Refresh Program, 100% Dry Ready-to-Wear Clothes, Eco Inverter Motor, 9 Swirl Wash Mimic Handwashing, Fully Automatic with Hot Water Wash, WiFi Connectivity with In-built Heater Brown (WDR EXECUTIVE ZMN) with Washing machine stands.
WBSEDCL three phase meter charge (Rs.40000.00 X 1no.)
Add GST @ 18%
Add cess @ 1%
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
Tendernotice_2.pdf
PDF • 1.35 MB
BOQ_2487886.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .