Tender Value
₹14.4 L
EMD Value
₹29,000
Closing Date
4 Jan 2020, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR
REPAIR REPLACEMENT OF OLD US WOODEN BOX METAL BOX DB MCBS SUBMAIN WIRING IN CERTAIN OTMs SMQ OMQs T AF STN MOUNT ABU
2019_MES_305910_1
85833 E8
Open Tender
Civil Works - Others
Item Rate
120 days
Mount Abu
Please refer tender document
7 documents required · 7 mandatory
₹500
GE AF NO 2 JODHPUR
₹29,000
Yes
1 Feb 2020
12 Dec 2019
6 Jan 2020
12 Dec 2019
4 Jan 2020
27 Dec 2019
Amount
Taking down main distribution board and dismantling of main switch board, DBs 8 Way , 12 way , 16 Way complete including fixture and fittings and removing materials to store for keeping in safe custody or removing from site and making good disturbed surfaces of wall floor etc. complete all as specified and directed.
Taking down MCBs any size and removing materials to store for keeping in safe custody or removing from site and making good disturbed surfaces of wall floor etc. complete all as specified and directed.
Taking down old MS / wooden shutter and boxes complete and removing materials to store for keeping in safe custody or removing from site and making good disturbed surfaces of wall floor etc. complete all as specified and directed.
Taking down old MS / wooden meter box complete and removing materials to store for keeping in safe custody or removing from site and making good disturbed surfaces of wall floor etc. complete all as specified and directed.
M&L for TPN sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar 6 way double door complete all as specified and directed.
M&L for TPN sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar 4 way double door complete all as specified and directed.
M&L for SPN sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar 12 way double door complete all as specified and directed.
M&L for SPN sheet metal enclosures distribution board where MCB to be used with 200 Amps rated bus bar 8 way double door complete all as specified and directed.
M&L in replacement for MCB TPN 100 Amps, C curve 440/415V complete all as specified and directed.
M&L in replacement for MCB TPN 63 Amps, 440/415V. complete all as specified and directed.
M&L in replacement for MCB SPN 40 Amps, 240 V complete all as specified and directed.
M&L in replacement for MCB SPN 20 Amps, 240 V. complete all as specified and directed.
M&L in replacement for MCB single pole 6-10 Amps, 240 V complete all as specified and directed.
Taking down old unserviceable submain wiring off size complete including fixture and fittings and removing materials to store for keeping in safe custody or removing from site and making good disturbed surfaces of wall floor etc. complete all as specified and directed.
M & L for Submain wiring with 2 runs of 6 Sqmm single core copper conductor cable FRLS drawn through in rigid PVC conduit ISI marked with fitting and 4 Sqmm single core copper conductor cable FRLS for continues earth wire concealed type incl cutting chases in stone wall for conduits all as directed. Note:- Two runs of main wire and one rum of earth wire and conduit shall be measured as one length.
M & L for submain wiring with 2 run of 4 S mm single core copper conductor cable FRLS drawn through in rigid PVC conduit ISI marked with fitting and 2.5 Sqmm single core copper conductor cable FRLS for continues earth wire concealed type incl cutting chases in stone wall for conduits all as directed. Note:- Two runs of main wire and one rum of earth wire and conduit shall be measured as one length.
Supply and Fix sintex meter boxes for installing electronic meteres double door hinged partition Size 700mmX480mmX210mm complete make-Sintex
M & L in replacement of MS shutter box made out of 2 mm thick sheet for protection and covering of meter box and main supply DB in box on wall including all hinges and lockup handle and painting etc complete
M & L rendering 15 mm thick on fair faces of brick work or concrete surfaces cement plaster 1:6 as in repair including three coat of white wash on wall
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0mm thick, buried directly in ground (earth pith not less than 2.25 mtr deep below ground level) with top edge of plated not less than 1.5 mtr below normal ground level connected toincl galvanized iron or steel earth lead wire 4.0mm dia by mean of bolts nuts check nuts & washers of galvanized iron or steel including 15mm dia medium grade GI protection pipe and connected to main switch board watering pipe shall be 20mm dia GI medium grade incl excavation earth work in any type of soil, PCC pit, RCC cover complete. Note:- GI protection pipe and earthwire upto 7.5 meters length shall be deemed to be included in quoted rates.
M&L for galvanized iron or steel earth lead wire 4.0mm dia complete.
M/S Balkishan Panwar Construction
Haritwal traders
rathore construction co.
Choudhary Traders and Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .