Loading…
Loading…
Tender Value
₹30 L
EMD Value
₹30,000
Closing Date
10 Sept 2026, 4:00 pm
Executive Engineer (O&M), DGVCL Bharuch Rural Division
Annual Rate contract for Erection and Maintenance work of HT/LT Line and TC Structure and Laying, Testing & Commissioning of 11/22KV underground XLPE cable with cable end termination & straight though jointing kits Work Under Villages Khojbal, Nandida and Akhod under Coastal Scheme under Atali Sub Division Only under Bharuch Rural Division
340147
BRH-2026-27-82
Open
Electrical and Maintenance Works
Works
Bharuch
1 document required · 1 mandatory
₹2,360
Executive Engineer DGVCL, Bharuch
₹30,000
30 Aug 2026
30 Aug 2026
30 Aug 2026
10 Sept 2026
30 Aug 2026
Labour rates for Annual Rate contract for Erection and Maintenance work of HT/LT Line and TC
Structure and Laying, Testing & Commissioning of 11/22KV underground XLPE cable with cable end
termination & straight though jointing kits Work Under Villages Khojbal, Nandida and
Akhod under Coastal Scheme under Atali Sub Division Only under Bharuch Rural Division.
::DGVCL Circular of Revised SOR rates for the year 2024-25::
1) Letter No: DGCS/1408/01/2025 Approved Date: 27-01-2025, 2) Letter No: DGCS/1411/01/2025
Approved Date: 27-01-2025 3) Letter No: DGCS/1408/01/2025 Approved Date: 27-01-2025
The Labour rates are excluding of GST.
(A). CAPITAL WORK LABOUR RATES
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING
OF CROSS ARMS, CLAMPS ANTI-CLIMBING DEVICES, DANGER
BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS AND NUMBERING COMPLETE WITH
COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING
OFCROSS ARMS, TOP FITTING CLAMPS ANTI- CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE
AND PAINTING OF STEEL POLE, FABRICATED MATERIALS
USED ON THE POLEAND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY
CROSSING ON BG/MG/NG LINE FOR 0.400/11/22KV OVERHEAD
LINES I.E INCLUDING EXCAVATION OF PIT & REFILLING OF
EARTH, FIXING CROSS ARMS, TOP FITTING CLAMPS, ANTI-
4 9926000004 CLIMBING DEVICES DANGER BOARD, INSULATORS ETC. No.
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COSTOF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS
KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
5 9926000005 DANGER BOARDS,INSULATORS ETC.COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS
AND EARTHING.(WITHOUT AB SWITCH)
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO
11 METERS.STEEL POLE INCLUDING EXCAVATION OF PITS &
REFILLING OFEARTH, FIXING OF CHANNELS, SUPPORTING
ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER
6 9926000006 BOARDS, INSULATORS ETC.COMPLETE & PAINTING OF No.
POLES,FABRICATED MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING
OF AB SWITCH, HG FUSES OF 8 MTRS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS SUPPORTING ANGLES,
CLAMPS, ANTI- CLIMBING DEVICES, DANGER BOARDS,
7 9926000007 INSULATORS,DOFUSES ETC. COMPLETE AND PAINTING OF No.
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDINGOF ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING
OF AB SWITCH,HG FUSES, 9 TO 11 METERS STEEL POLES
INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,
FIXING OFCHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-
CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC.
COMPLETE AND PAINTING OF POLES FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.(WITH AB
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING
OFAB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 8 METER, 200KG PSC
POLE METERS POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS, SUPPORTING
ANGLES, BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING
DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS
USEDON THE POLES AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING
OF AB SWITCH,HG FUSES TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX 9 TO 11 METERS STEEL
POLES INCLUDING EXCAVATION OF PITS & REFILLING OF
EARTH CARTING OF TRANSFORMERS FROM STORE TO SITE,
FIXINGOF CHANNELS SUPPORTING ANGLES, BRACING,
CROSS ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC. COMPLETE
AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS OF GUY SETS
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH AS PER STANDARD SPECIFICATION
11 9926000011 WITH STAY CLAMPS, STAY WIRE, ANCHOR ROD, TURN No.
BUCKLE, EYEBOLT, GUY INSULATOR, CEMENT CONCRETE
BLOCK ETC. BUT EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF
CEMENT SAND METAL (1:2:4) AND WATER ETC. AS PER
STANDARD SPECIFICATION.(cement Should be 53 grade)
used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING COST OF
13 9926000013 COAL,SALT ETC. BUT WITHOUT COST OF GI WIRE AS PER No.
STANDARD SPECIFICATION(20kg solt+20kg coal)
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING
INCLUDINGCOST OF COAL SALT ETC. BUT WITHOUT COST OF
PIPE/GIPLATE GI WIRE AS PER STANDARD SPECIFICATION.
(20kg solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE COMPLETE WITH
CLAMPS, BRASS NIPPLE, BRASS HOLDER TECK WOOD
BUSH,REFLECTORS FUSE, WIRING ETC. AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
STRINGING OF(30mm2)ACSR/34MM@,55MM2 AAA
CONDUCTOR for ALL TYPE OF CONDUCTOR (EXCEPT DOG
CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING
OF INSULATORS, BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC
2.5/4MM2 TWIN CORE CABLE FROM TERMINAL POLE TO
18 9926000018 METERING POINT INCLUDING FIXING OF METER WITH No.
METER EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION
WITH PVC 4MM2/10MM2 FOUR CORE CABLE FROM TERMINAL
POLE TO METERING POINT INCLUDING FIXING OF METER
WITH METER EARTHING COMPLETE WORK AS PER
STANDARD SPECIFICATION BUT EXCLUDING COST OF
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK
AREA FOR ERECTION OF POLE/ GUY ETC. AS PER STANDARD
SPECIFICATION OVER & ABOVE NORMAL COST COVERED
AGAINST EXCAVATION OF PIT UNDER NORMAL SOIL FOR
ERECTION OF POLE, GUY, DOUBLE POLE STRUCTURE
EARTHING WITH THE APPROVAL OF SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL
PROVIDING GUARDING OF LT LINES ON ROAD/RAIL
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND TELEPHONE LINE No.
CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTOR, DISTRIBUTION
BOX. ON 8 METERS 200 KGAND PSC POLE INCLUDING
EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING
OF TRANSFORMERS FROM STORES TO SITE, FIXING OF
CHANNELS, SUPPORTING ANGLES, BRACINGS CROSS ARMS
CLAMPS, ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING
OFAB SWITCH , HG FUSES, TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON 9 to
11 METERS RSJ POLE INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS FROM
STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
27 9926000027 ANGLES, BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING No.
DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS
USED ON THE POLE AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OFGUY SETS AND EARTHING.
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF
CROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS
KG PSC POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES
29 9926000029 DANGER BOARDS,INSULATORS ETC.COMPLETE AND No.
PAINTING OF FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS
AND EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR ONE
30 9926000030 FOR 11/22KV & LT LINES INCLUDING FIXING COND
OFINSULATORS, BINDING JUMPERING ETC. PER KM
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES ONE
31 9926000031 INCLUDING FIXING OF INSULATORS, BINDING JUMPERING COND
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING
OF AB SWITCH, HG FUSES, TRANSFORMERS, LIGHTENING
ARRESTORS, DISTRIBUTION BOX. OF 10 METERS
KGAND PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS
FROMSTORES TO SITE, FIXING OF CHANNELS, SUPPORTING
32 9926000032 ANGLES, BRACINGS CROSS ARMS CLAMPS, ANTI-CLIMBING No.
DEVICES, DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF FABRICATED
MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF
33 9926000033 FABRICATION AT STORE & STACKING OF POLE SAFELY ON No.
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF
34 9926000034 FABRICATION AT STORE & STACKING OF POLE SAFELY ON No.
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC
POLE) (WITH TRANSFORMER) WITH CREDITING OF
35 9926000035 FABRICATION & TRANSFORMER AT STORE & STACKING OF No.
POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC
POLE) (WITHOUT TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE & STACKING OF POLE SAFELY ON
ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF
37 9926000037 MESSENGER WIRE AND TO PROVIDE SERVICE KM
CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE CONNECTION
BOX COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF
38 9926000038 MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION KM
ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED & DIRECTED BY
ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM
INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND DIRECTED BY
ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ
MM INCLUDING FITTING OF ALL ACESSARIES I.E. SPECIAL
DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF
41 9926000041 MESSENGER WIRE AND TO PROVIDE SERVICE CONNECTION KM
ON AERIAL BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE CONNECTION BOX
COMPLETE AS REQUIRED & DIRECTED BY ENGINEER IN
DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING
THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITHOUT TRANSFORMER) WITH
43 9926000043 CREDITING OF FABRICATION AT STORE AND STACKING OF No.
POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON
10MTR,270KG PSC POLE(WITH TRANSFORMER) WITH
44 9926000044 CREDITING OF FABRICATION AT STORE AND STACKING OF No.
POLE SAFELY ON ROAD SIDE OR CREDITING TO
DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND
45 9926000045 CREDITING FITTING OF ALL ACESSARIES AND FABRICATION KM
TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM
46 9926000046 AND CREDITING FITTING OF ALL ACESSARIES AND KM
FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM
47 9926000047 AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ
48 9926000048 MM+1*35 SQ MM AND CREDITING FITTING OF ALL KM
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+
49 9926000049 SQ MM AND CREDITING FITTING OF ALL ACESSARIES TO KM
DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG ONE
50 9926000050 CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING COND
OF INSULATORS, BINDING JUMPERING ETC. PER KM
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES
INCLUDING , BINDING JUMPERING ETC.
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR
METER. (METER WILL BE PROVIDED BY DGVCL)
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER
53 9926000053 AND OLD METER SHOULD BE CREDITED TO SDN STORE. No.
(METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER
CONNECTION. (CT COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR
55 9926000055 METER CONNECTION AND OLD CT SHOULD BE CREDITED TO PER CT
SDN STORE. (CT COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER
(MMB WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX.
(METER WILL BE PROVIDED BY DGVCL)
58 9926000058 PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER No.
CABLE 3.5 METER (CABLE TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF PER
59 9926000059 TERMINAL CONNECTION WITH PROPER SIZE OF LUGS. (LUGS TERMINA
COST IS BORNE BY AGENCY) TION
LABOUR CHARGE FOR THE SPOT READING OF DTR METER
WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY
BY SURVEYOR PERSON OF AGENCY IN PRO- FORMA REPORT
60 9926000060 SHOULD BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PER DTR
PARAMETER OF VOLTAGE, CURRENT & LOAD AS SHOWN IN
PER-FORMA IS FILLED) AS PER THE INSTRUCTION OF
ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER
WITH DETAIL SURVEY OF DEFECT IF ANY. A DULY SIGN COPY
BY SURVEYOR PERSON OF AGENCY IN PRO- FORMA REPORT
SHOULD BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-
FORMA IN FAULT CONDITION IN WHICH READING
PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER BOX,
PROVIDING & FIXING OF 1.5SQ MM SINGLE STRAND 10 CORE
62 9926000062 ARMOURED COPPER CABLE (3.5METER), TERMINATION IN No.
METER & COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL
BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING METER BOX,
TERMINATION IN METER & COIL ETC. (WITHOUT 10CORE
COPPER CABLE) (METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
Binding of messenger Conductor at with a distance not more
64 9926000064 than 0.75 mtr with 6 turns minimum on XLPE Cable with single No
strand binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT
65 9926000086 Terminal protector (UV Resistance) with using 95/120/150 sq.mm PER SET
long barrel aluminium lug. (1Set = 3 Nos i.e. on R, Y, B)
Supply & Installation of HT EPR Tap on 11/22 kV Distribution
Transformer with replacement of bare conductor by HT ABC
66 9926000087 conductor (DO bottom side to transformer) after removal of PER SET
semiconductor by HT ABC (6 inch both side). HT ABC to be
supplied by DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of Maintenance
Free, Ready Capsule, Pipe-In- Cage (Pic) Type, Earth Electrodes
67 9926000088 for HT Feeder Pole Having 2000 mm Electrode Length as per the NO
Tender Specifications and Drawing. (All Materials Will Be
Supplied By Agency)
Supply, Installation, Testing and Commissioning of Maintenance
Free, Ready Capsule, Pipe-In- Cage (Pic) Type, Earth Electrodes
68 9926000089 for HT Feeder Pole Having 3000 mm Electrode Length as per the NO
Tender Specifications And Drawing. (All Materials Will Be
Supplied By Agency)
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
Supply and Installation of 25 X 3 mm GI Strip having hot dip-
galvanized-zinc coating of 80-100 microns without any joints or
welding. Both the end of the GI strip should be connected with GI
nut bolts and required fabrication work for giving separate
earthing connections to
(1) Neutral of the transformer
(2) MS structures of the transformer centre (Approximately
meter GI strip per transformer centre
- as per requirement and instruction of Engineer in-
charge) (All Materials will be supplied by Agency)
Supply and Installation of uPVC standard make Pipe of 1.25"
diameter for covering GI strip with UV protected Cable Ties of
70 9926000092 550 X 7.6 mm size to bind with pole face(Approximately 25 meter Meter
uPVC pipe for GI strip covering per transformer centre -as per
requirement and instruction of Engineer in-charge.
Supply & fixing of up to 33 kV Conductor sleeve for Busbar to
Drop out Fuse and Drop out fuse to Transformer H.T. including
Busbar (12 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to
Drop out Fuse and Dropout fuse to Transformer H.T. without
Busbar (12 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
Supply & fixing of up to 33 kV Conductor sleeve for Busbar to
Drop out Fuse and Drop out fuse to Transformer H.T. including
Busbar(15 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
Supply & fixing of upto 33 kV Conductor sleeve for Busbar to
Drop out Fuse and Drop out fuse to Transformer H.T. without
Busbar(15 mm sleeve) as per technical specification. (All
Materials will be supplied by Agency)
Supply & fixing of Disc type Red Colour FRP(Non-flammable)
material with Weather resistant, Non-conductive bird guard
OD=300 MM, ID=33 MM, Width =1.25 MM, one side cut from ID
to OD. (All Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-useable
boot (LT Side 1.1 kV) including LT (1.1 kV) insulating taps. All
live part at LT side shall be covered with fixing of LT insulating
Nylon Net around Transformer Centre
77 9926000097 Nylon Net (12 * 15 ft) Per Net
78 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated material for
fitting nylon net shall be provided by DGVCL)
(B) LINE MAINTENANCE
80 9924000001 Cutting of Tree branches surrounding HT/LT line Per Tree
Replacement of old jumpers & providing new double jumpers with
8" binding [D Type] & capsuling with PVC pipe etc
82 9924000005 Support pole for Stay PSC/STP/RSJ No.
83 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
Pin binding of conductor 11/22kv Pin insulator per pole in coastal
area with cleaning.
85 9924000008 Pin binding of conductor LT shackle insulator No.
86 9924000009 Replacement of one/both disc. insulator at strain pole No.
87 9924000010 Replacement of LT shackle insulator at cut point No.
88 9924000011 Refixing of V cross Arm No.
89 9924000012 Replacement of V cross Arm (With Transportation & Painting) No.
90 9924000013 Refixing of Top fitting in proper position No.
91 9924000014 Replacement of Top fitting No.
92 9924000015 Replacement of LT cross Arm No.
Providing DO fuse on DP with carting & jumpering (ONE DO
Numbering of pole with paint by preparing back ground of one
colour and have lettering(height 3" * width 0.5") using stencil
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
95 9924000018 Fixing of MMB(1PH.) at consumer end No.
96 9924000019 Fixing of MMB(3PH.) at consumer end No.
97 9924000020 Replacement of (1ph.) meter for Urban area No.
98 9924000021 Replacement of (1ph.) meter for Rural area No.
painting consumer no. on MMB (Urban) (with letter size height
40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter size height
40mm* width 8mm)
101 9924000024 Replacement of deteriorated Single phase Service line No.
Fixing of new dist. Box with complete wiring including clamps,
Repairing of guarding involving reshaping of bearer wire cross
lacing binding etc.
Painting of steel fabricated material of RSJ DO DP structure with
Painting of steel fabricated material of RSJ pole mounted
transformer double pole structure with paint
106 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
painting of steel fabricated material of PSC Single pole (HT
line) with paint
painting of steel fabricated material of PSC DO DP double pole
painting of steel fabricated material of PSC double pole at pole
mounted transformer with paint
110 9924000033 Providing line separator single phase No.
111 9924000034 Providing line separator three phase No.
Replacement / Providing of stay insulator along with adjustment
of tension in stay wire
Replacement of deteriorated /providing LT dist. Box with new up
to 100KVA capacity & crediting it to store.
Replacement of deteriorated/providing LT dist. Box with new
above 100KVA capacity & crediting it to store.
115 9924000038 Adjustment of tension in stay wire No.
116 9924000039 Refitting of LA No.
Converting pin point to Shackle point including dismantling &
117 9924000040 location
restringing etc.
replacement of 11KV Pin insulator with providing new double pin
replacement of 22KV Pin insulator by new 11kv pin insulator with
spares & providing new double pin binding
120 9924000043 Providing 11kv double disc insulators with binding & restringing No.
Replacement of existing 11kv conductor (all size) with new double
122 9924000046 Plumbing of PSC Pole with straightening at pin point No.
123 9924000047 Plumbing of PSC Pole with straightening at tension point No.
Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of
stone Murom etc.
Providing new 11kv AB /GO switch with fabrication and insulated
colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with providing new
insulated jumper, binding, lugs etc
Providing cage type loop guard in vertical LT line with using PVC
127 9924000052 per pole
reel insulators etc
Labour charges for replacement /providing of MMB & service with
all accessories for three phase connection
Labour charges for replacement /providing of MMB & service with
all accessories for single phase connection
Dismantling of existing Dist. X'mer centre(RSJ /STP POLE)
130 9924000055 25/63/100/200 KVA with all fabrication & crediting the old No.
material to store
131 9924000056 Disconnection from LT pole 1 phase No.
Reconnection from LT pole 1 phase ( payment after receipt of R/C
133 9924000058 Disconnection from LT pole 3 phase No.
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
Reconnection from LT pole 3 phase ( payment after receipt of R/C
Dismantling & removing of service line from pole & crediting to
Dismantling & removing of service line from pole & crediting to
137 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No.
138 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No.
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in
length) with salt and coal 10kg each, including pvc rigid pipe
139 9924000064 20mm dia. ( 1.5mtr length) to pass exposed part of G.I. wire at No.
consumer end with all materials, earth resistance should be less
Providing and fixing of single core 1.5 sq mm single strand copper
insulated cable with cable nail clip for spiral type earthing at
consumer end. The end of G.I. no 8 is to be connected by
connector with copper cable of which other end shall be
140 9924000070 connected to the earth terminal of meter box. This item shall be per meter
used in location where there is more distance between earth
terminal and earthing terminal of meter. (All materials supplied
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including
fitting of all accessories i.e. special design suspension / tension
clamp, fixing of cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge of existing
141 9924000065 bare conductor and crediting in to store & dismantling of service KM
line from LT bare conductor and to provide service connection on
Aerial Bunch Cable by insulated piercing connectors through
service connection box complete as required & directed by
Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM
including fitting of all accessories i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle insulator etc. for
fixing of messenger wire and inclusive of dismantling charge of
142 9924000066 existing bare conductor and crediting in to store & dismantling of KM
service line from LT bare conductor and to provide service
connection on Aerial Bunch Cable by insulated piercing
connectors through service connection box complete as required
& directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including
fitting of all accessories i.e. special design suspension / tension
clamp, fixing of cross arm, binding to pin insulator, preparing
shackle point, jumpers etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to store complete as
required & directed by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including
fitting of all accessories i.e. special design suspension / tension
clamp, fixing of cross arm, binding to pin insulator, preparing
shackle point, jumpers etc. and inclusive of dismantling charge of
existing bare conductor and crediting in to store complete as
required & directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM
including fitting of all accessories i.e. special design suspension /
tension clamp, fixing of cross arm, LT shackle insulator etc. for
fixing of messenger wire and inclusive of dismantling charge of
145 9924000069 existing bare conductor and crediting in to store & dismantling of KM
service line from LT bare conductor and to provide service
connection on Aerial Bunch Cable by insulated piercing
connectors through service connection box complete as required
& directed by Engineer in Charge.
(C) UG CABLE RATES
Labour charge for excavation of cable trench of 400mm width x
1200mm depth, in any type of soil for laying of cable of size up
to 240 mm2 (For additional cable 200 mm additional width shall
be considered i.e. half trench length is to be considered)
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
Labour charge for excavation of cable trench of 600mm width x
1200mm depth, in any type of soil for laying of cable of size up
to 240 mm2 (For additional cable 200 mm additional width shall
be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x
1500mm depth, in any type of soil for laying of cable of size up
to 240 mm2 (For additional cable 200 mm additional width shall
be considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to
240 mm2 & preparation of sand layer 100mm thick, in the cable
trench & covering the cable with 150 mm dia (Inner), thickness
25 mm, 1.0 meter long RCC half round muffs and providing and
149 9925000004 fixing of 4inch width yellow colour polyethylene tape with Meter
printing "CAUTION ELECTRIC CABLE BELOW" at 0.75 m depth
from ground surface after laying cable in trench. This will provide
indication that electric cable is passing underground so as to
protect cable from mechanical injuries, refilling the same, as per
Instruction of Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger
machine without damage to surface road at max 2.0 mtrs depth
& putting of 6.11 kg/cm2 , class-4,Green colour, 110mm O.D.
8.5mm thickness H.D.P.E. pipe confirms to IS 4984- 1987(3rd
revision) and BIS certification and laying of 11KV/22KV XLPE
cable of size up to 240 mm2 in HDPE pipe, as per Site Condition
150 9925000005 (excluding cost of pipe). The detail map obtained from HDD Meter
machine and excel sheet (hard and soft copy) indicating the
respective depth and distance from adjacent landmark for each
segment for HDD is must require to be submitted. HDD to be
depth 1.5 mtrs to 2.0 mtrs as per site conditions and as per
instruction of EIC.
Labour charge for horizontal drilling manually without damage
to surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2,
class-4, Green colour, 110mm O.D. , 8.5mm thickness H.D.P.E.
pipe confirms to IS 4984-1987(3rd revision) and BIS certification
and laying of 11KV/22KV XLPE cable of size up to 240 mm2 size,
as per Site Condition (excluding cost of pipe). The detail map and
excel sheet (hard and soft copy) indicating the respective depth
and distance from adjacent landmark for each segment of cable to
be submitted. Drilling to be carried out at depth Minimum
mtrs to 2.0 mtrs as per site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green colour, 110mm O.D. ,
mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification for laying of underground 11KV / 22KV XLPE cable
up to 240 mm2 size.
Labour work for RCC concreting on disputed location and
repairing of damage portion of road crossing for the work carried
out for roads crossing as well as concreting & muffing of
poles including all materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width
x 150 mm thick x 650 mm height embedded in earth at least
300 mm below & 350 mm above ground level respectively at
distance approx. 50 meters along the length of cable. The RCC
concreting (1:2:4)(all necessary materials will be in bidder's
scope) of route marker is to be carried out 300 mm width x
154 9925000009 mm thick x 300 mm below ground level as per instruction of No.
EIC. The route marker should be with name of company with
approved yellow colour-DGVCL. The distance from marker to
cable and cable depth with feeder name etc., marked with arrow
sign is to be painted on it. The route marker is to be fixed at
location near to any fixed permanent location (not necessary to fix
exact on top of cable) as per instruction of EIC.
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
Erection of D.P. (double pole) structure using 9 / 11 Mtr.
RSJ pole with cable connection arrangement along with fitting of
155 9925000010 necessary fabrication for 11KV cable including excavation of pit & No.
refilling of earth as per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ
pole with cable connection arrangement along with fitting of
156 9925000011 necessary fabrication for 11KV/22 KV cable including excavation No.
of pit & refilling of earth as per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC
pole with cable connection arrangement along with fitting of
157 9925000012 necessary fabrication for 11KV cable including excavation of pit & No.
refilling of earth as per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole with
cable connection arrangement along with fitting of necessary
158 9925000013 fabrication for 11KV/22 KV cable including excavation of pit & No.
refilling of earth as per instruction of EIC. (Exclusive of
concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size
up to 240 mm2 on DP Structure with fixing of 02 Nos
polymer cleats on top and middle part. Polymer cleats, nut
bolts etc. fixing material to be provided by contractor.
Providing & fixing of 6.11kg/cm2, class-4, Green colour,
110mm O.D., 8.5mm thickness H.D.P.E. pipe confirms to IS
4984 and BIS certification on the erected DP structure for
the mechanical protection of cable by inserting the cable inside
160 9925000015 HDPE pipe. The HDPE pipe shall be erected in such a way that Per Job
300mm shall be below the ground level and the rest 2700mm
shall be supported on the DP Structure with 01 No Polymer
cleat. All materials including polymer cleat and Nut bolt to be
provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-
B GI pipe with pit to be filled with salt & coke and construction of
chamber as per DGVCL Drg. No. dg /100 for DP and cable. The
earthing pit should be joined with cable by G.I. strip of size 1”
width & 2 mm thick. All material GI pipe, Coke, Salt etc will be
supplied by bidder.
Supply & fixing of heat shrink type end terminations
(outdoor) for up to 11kV 3C x 185 mm2 size XLPE cable as
per DGVCL technical specification. (Make 3M or Raychem
Supply & fixing of heat & shrinkable end terminations
(outdoor) for up to 22 Kv 3C x 185 mm2 size XLPE cable as
per DGVCL technical specification. (Make 3M or Raychem
Supply & fixing of heat shrink type end terminations (indoor)
164 9925000019 for up to 11kV 3C x 185 mm2 size XLPE cable as per DGVCL No.
technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations (indoor)
165 9925000020 for up to 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL No.
technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint for up
166 9925000021 to 11kV 3C x 185 mm2 size XLPE cables per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint type
167 9925000022 for up to 22kV 3C x 185 mm2 size XLPE cable as per DGVCL No.
technical specification. (Make 3M or Raychem Only)
Labour charge for excavation of 2100mm long x 1200mm wide x
1200 mm deep joint pits for installation of 11kV / 22kV
Straight through joints as per instruction of engineer-in-
charge & covering the cable with 150 mm dia (Outer), thickness
25 mm, 1.0 meter long RCC half round muffs & refilling same
as per instruction of EIC.
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
Providing and fixing of insulating bus bar, made from 11KV/22KV
XLPE cable after removal of semi conducting layer and applying
of PVC heat shrinkable anti- tracking core insulating tubing
(1.1KV), on both end terminal using Aluminium long barrel heavy
duty up to 240 sq mm lugs, Aluminium bus connector. Taping
with PG- clamp for bus conductor as per drawing and as per
instruction of EIC. The Aluminium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating tapes.(11KV/22KV XLPE
cable will be in scope of DGVCL while all other materials will be in
bidder's scope)
Testing of cable at various points and commissioning the feeder
170 9925000025 as per instruction of engineer-in-charge. Test result shall be No.
submitted by contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout
drawings with GIS mapping as per actual cable routing
showing road crossing, HDPE pipe sleeving, jointing locations,
Providing and fixing of Sign Board at junction point Made out of
mm aluminium sheet size 750x300 mm (2.5 x 1ft) rectangle, as
per design, pre-treated with phosphate process and acid etching
coated with one coat of epoxy primer and two coats of best quality
paints, reflectorized with Hi-Intensity retro – reflective sheeting
as per the latest and frame fabricated from suitable size iron
angle. The Sign Board is to be fixed on the base prepared from
channel and bracing angles which is grouted by means of cement
concreting of 1:2:4 for size of 300 mm dia x 800 mm height (500
mm to be grouted in ground). The details to be displayed on sign
board will be given by In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution
Transformer Centres Made out of 2mm aluminium sheet size
300x300mm (1x1ft) as per design, pre-treated with phosphate
process and acid etching coated with one coat of epoxy primer
and two coats of best quality paints, reflectorized with Hi-
Intensity retro- reflective sheeting as per the latest and frame
fabricated from suitable size iron angle. The Sign Board (Danger
Board is to be fixed at the location as per instruction of In-charge
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm
(W) from 3 mm aluminium sheet along with 1.0 mm dia
aluminium binding wire for fixing of aluminium tag near end
174 9925000029 termination joint at DP structure for identifying the cable. The No.
details of feeder i.e. 11 / 22 KV with feeder name should be
punched on the tag by letter punch of size 16 mm as per
instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations
175 9925000030 (outdoor) for 11kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations
176 9925000031 (outdoor) for 22 kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrink type end terminations
177 9925000032 (indoor) for 11kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat & shrinkable end terminations
178 9925000033 (indoor) for 22 kV 3C x 240 mm2 size XLPE cable as per No.
DGVCL technical specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint for
179 9925000034 11kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
Supply & fixing of heat shrinkable straight through joint type
180 9925000035 for 22kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
specification. (Make 3M or Raychem Only)
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRL type- 3 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRLL type- 4 Way RMU including Two numbers
of earthings as per Drawing (material is in bidder's scope) and as
per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRL type-3 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRLL type-4 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e. Two
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:
Drg. 11kv-01. All required material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two
numbers of Isolator & Two number of Breaker)Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:Drg.
11kv-02.All required material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:
Drg. 22kv-01. All required material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e. Two
numbers of Isolator & Two number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:Drg.
22kv-02.All required material will be supplied by contractor.
Modifications e.g. Providing and fixing of Terminal protectors i.e.
Re-use able boot (HT Side 11/22KV, LT Side 1.1KV) including
11/22 KV insulating taps and L.T.(1.1 KV) insulating taps ,Busbar,
Tapping from Bus Bar (11/22 KV XLPE cable) through P.G.
Clamp for H.T. Jumper to D.O. Fuse to bushings of Transformer
Centre, providing & Fixing of jumper and providing & fixing of
Heat Shrinkable Anti Tracking Core Insulating Tubing (Insulation
189 9925000046 Level 11/22 KV) in H.T. jumper , Clamping arrangement of cable No.
support frame on both side of existing Over Head type
Distribution Transformer to utilize in Under Ground cable
network as per drawing & as per instruction of Engineer in
charge. All live parts i.e. PG-Clamp, connections of D.O. fuses, HT
bushings etc. shall be covered with fixing of 11/22 KV HT
insulating tapes. (11/22 KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope).
Laying of any size of 11/ 22 KV XLPE /PILC Cable in readymade Per Cable
trench or in open space Per Mtr
191 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long
RCC half round pipe
Laying, Testing & commissioning of Specially designed 11 KV
193 9601000866 55mm2 AAAC Medium Voltage Covered conductor as per the CKM
technical specifications (with accessories)
ESTIMATE COST Thirty Lakh Rupees Only. Rs. 30,00,000/-
1. DGVCL will provide key material like M.S. materials, ABC/Bare conductors, PSC/RSJ Poles, Insulators,
Fabricated materials etc. to the contractor.
2. All fabricated items shall be fabricated as per DGVCL approved drawing and by welding rods
confirming to the relevant ISI specification and as directed by Engineer in charge.
3. Necessary electricity connection for fabrication items shall be provided by DGVCL on payment of
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Letter No: DGVCLDBHR/0427/08/2026 Approved Date: 29-08-2026 04:36
required charge for connection & electricity bill of the same shall be paid by the agency.
4. All the rates are inclusive of PF & Exclusive of GST applicable time to time.
5. All steel material are to be painted as below:
1. Scrubbing of rusted surface properly before applying the paints on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles is must require.
2. Two coats of approved ISI mark red oxide (primer) is to be properly painted for the RSJ poles &
steel fabricated materials of RSJ/PSC poles.
3. Two coats of approved ISI mark silver paint (i.e. triple mangoes or equivalent quality silver paint)
is to be properly painted on to the RSJ poles & steel fabricated materials of RSJ/PSC poles.
6. Cable End Termination and Straight Joint should be of Make 3M or Raychem Only.
Executive Engineer,
Bharuch Rural Division,
DGVCL, Bharuch.
File No: DGVCLDBHR/TEN/e-file/4444/2026/2694/Technical
Approved By: Executive Engineer,Technical,DGVCLDBHR
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SCHEDULE-B TENDER NO BRH-2026-27-82.pdf
CONDITIONS TENDER NO BRH-2026-27-82.pdf
NOTICE INVITING TENDER BRH-2026-27-82.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].