All Schedules CURRENT TRANSFORMER(WOUND PRIMARY), BURDEN:15VA RATIO:60/1A,CLASS:1, INSULATION CLASS:B REF. STD:IS2705 FREQUENCY:50/60HZ,STC:3KA FOR1SEC, HSV/IL:0.66/3KV MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. L.T Resin Cast Rectangular Window Type CT Frequency:50/60 Hz Ratio :3200/1A Class: 0.5 Burden: 15VA ISF less than or equal to 5 ILV 0.72/3 kV. Ins Class: B Ref Std: IS16227-1 and 2 ID :210x40mm. Secondary Terminals on 40mm Side. Drawing No: LRRM-13-30-WOC Enclosed MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. L.T Resin Cast Rectangular Window Type CTFrequency: 50/60 Hz Ratio: 3200/1AClass: PS(As per tender documents)MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. L.T.Residual Voltage Transformer Three Phase Frequency:50/60 Hz Ratio: 415V/RT3//110V/3 Class: 3P(Residual Protection) Burden :50VA (Total) Voltage Factor : 1.2 Continuous./1.9 for 8 hrs. ILV 0.72/3 kV. Ins Class: B Vector Group/Connection :Star-open delta Primary:A,B,C,N Secondary:da,dn Ref Std IS16227-1 and 3 Type : Resin Cast.Terminals are terminated to terminal blocks. Drawing No. RPT-3PH-W-17-3448-04-Rev-01 Note: Three Nos. Single Phase Voltage Transformers mounted on common base MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. L.T.Voltage Transformer Three Phase Frequency: 50/60 Hz Ratio: 415V/110V (Phase to Phase) ,415V/RT3//110V/RT3 (Phase to Neutral) Class: 0.5 Burden :50VA(Total) Voltage Factor: 1.2 Continuous./1.9 for 8 hrs. ILV :0.72/3 kV. Ins Class :B Vector Group/Connection :Star/Star(YNyN0) Ref Std: IS16227-1 and 3 Type : Resin Cast. Terminals are terminated to terminal blocks. Drawing No. RPT-3PH-W-17-3448-02-Rev-01 Note: Three Nos. Single Phase Voltage Transformers mounted on common base MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. L.T.Voltage Transformer Three Phase Frequency: 50/60 Hz Class :3P Burden :50VA (Total) Ratio: 415V/110V (Phase to Phase) ,415V/RT3//110V/RT3(Phase to Neutral) Voltage Factor :1.2 Continuous./1.9 for 8 hrs. ILV: 0.72/3 kV. Ins Class:B Vector Group/Connection:Star/Star(YNyN0) Ref Std: IS16227-1 and 3 Type : Resin Cast.Terminals are terminated to terminal blocks. Drawing No. RPT-3PH-W-17-3448-03-Rev-01 Note: Three Nos. Single Phase Voltage Transformers mounted on common base. MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Class PS Transformer (Bar primary) Ratio : 630/1A Insulation Class :B Ref. Std. : IS 2705 Vk greater than or equal to 120 V, RCT less than or equal to 3 Ohms, Imag: Vk/2 less than or equal to 30mA Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 170 x 110, HT equal to 65 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Class PS Transformer (Bar primary) Ratio : 1600/1A Insulation Class :B Ref. Std. : IS 2705 Vk greater than or equal to 350 V, RCT less than or equal to 7.5Ohms, Imag : Vk/2 less than or equal to 30 mA Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 160 x 80, OD equal to 250 x 170, HT equal to 70 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Class PS Transformer (Bar primary) Ratio : 2500/1A Insulation Class :B Ref. Std. : IS 2705 Vk greater than or equal to 256 V, RCT less than or equal to 8Ohms, Imag : Vk/2 less than or equal to 30 mA Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 160 x 80, OD equal to 260 x 175, HT equal to 50 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Class PS Transformer (Bar primary) Ratio : 3200/1A Insulation Class :B Ref. Std. : IS 2705 Vk greater than or equal to 395V, RCT less than or equal to 15 Ohms, Imag : Vk/2 less than or equal to 30mA Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 160 x 80, OD equal to 260 x 180, HT equal to 45 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Class PS Transformer (Bar primary) Ratio : 4000/1A Insulation Class :B Ref. Std. : IS 2705 Vk greater than or equal to 450V, RCT less than or equal to 20Ohms, Imag: Vk/2 less than or equal to 30mA Dimensions : ID equal to 160 x 100, OD equal to 260 x 195, HT equal to 45 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 1000/1A Burden : 15 VA Class : 0.5 Insulation Class: B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 110 x 30, OD equal to 160 x 80, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 1000/1A Burden : 15 VA Class : 1 Insulation Class: B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 110 x 30, OD equal to 160 x 80, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 125/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 3KA for 1 Sec HSV/IL: 0.66/3KV Terminal Arrangement:3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 150/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 30, OD equal to 95 x 95, HT equal to 75, Terminal Arrangement: NA MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 1600/1A Burden : 15 VA Class : 0.5 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 110 x 40, OD equal to 170 x 95, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 200/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20,OD equal to 130 x 85, HT equal to 50 Terminal Arrangement: 1(SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 250/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 140 x 95, HT equal to 45 mm Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 2500/1A Burden : 15 VA Class : 0.5 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 160 x 80, OD equal to 225 x 130, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 2500/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 160 x 80, OD equal to 225 x 130, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 3200/1A Burden : 15 VA Class : 0.5 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Insulation Class :B Ref. Std. : IS 2705 Dimensions : ID equal to 160 x 80, OD equal to 220 x 130, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 400/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 130 x 75, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 4000/1A, Burden : 15 VA, Class : 5P20 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Insulation Class : B Ref. Std. : IS 2705 Dimensions : ID equal to 160 x 100, OD equal to 290 x 195, HT equal to 55 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 630/1A Burden : 15 VA Class : 0.5 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 120 x 80, HT equal to 50 Terminal Arrangement: 1(SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary) Ratio : 630/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 120 x 80, HT equal to 50 Terminal Arrangement: 1(SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Bar primary)Ratio : 4000/1A, Burden : 15 VA,Class : 0.5 Frequency: 50/60Hz,STC: 50KA for 1 SecHSV/IL: 0.66/3KV Insulation Class : BRef. Std. : IS 2705Dimensions: ID equal to 160 x 100, OD equal to 235 x 160, HT equal to 40 Terminal Arrangement: 1 (SHORTER SIDE)MAKE:Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 10/1A Frequency: 50/60Hz, STC: 3KA for 1 Sec HSV/IL: 0.66/3KV Burden : 15 VA Class : 1 Insulation Class :B , Ref. Std. : IS 2705 Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement: 3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 100/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 3KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement:3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 20/1A Burden : 15 VA Class : 1 Insulation Class :B Frequency: 50/60Hz, STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Ref. Std. : IS 2705 Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement: 3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 25/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement: 3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 5/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705. Frequency: 50/60Hz,STC: 3KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement: 3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 50/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement: 3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio : 75/1A Burden : 15 VA Class : 1 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 3KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : L equal to 125, W equal to 95, H equal to 95 Terminal Arrangement: 3 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio:15/1A,VA:15,Class:1,Insulation Class: B HSV/I.L: 1.1/3.4KV, Ref Std: IS2705,IEC -44 -1 Frequency:50/60Hz,volts:1100V,ISF less than 5 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Metering Current Transformer (Wound primary) Ratio:30/1A,VA:15,Class:1, Insulation class: B HSV/I.L: 1.1/3.4KV, Ref Std: IS2705,IEC -44 -1 Frequency:50/60Hz,volts:1100V,ISF less than 5 MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 1000/1A Burden : 15 VA Class : 5P20 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 110 x 30, OD equal to 210 x 130, HT equal to 60 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 1600/1A Burden : 15 VA Class : 5P20 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 110 x 40, OD equal to 210 x 130, HT equal to 55 mm MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 250/1A Burden : 15 VA Class : 5P20 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 65KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 210 x 160, HT equal to 95 mm Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 2500/1A Burden : 15 VA Class : 5P20 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 160 x 80, OD equal to 255 x 160, HT equal to 60 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 3200/1A Burden : 15 VA Class : 5P20 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Insulation Class :B Ref. Std. : IS 2705 Dimensions : ID equal to 160 x 80, OD equal to 260 x 175, HT equal to 50 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 400/1A Burden : 15 VA Class : 5P20 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz,STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 185 x 130, HT equal to 75 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Protection Current Transformer (Bar primary) Ratio : 630/1A Burden : 15 VA Class : 5P20 Insulation Class :B Ref. Std. : IS 2705 Frequency: 50/60Hz, STC: 50KA for 1 Sec HSV/IL: 0.66/3KV Dimensions : ID equal to 60 x 20, OD equal to 170 x 120, HT equal to 80 Terminal Arrangement: 1 (SHORTER SIDE) MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Single Phase Voltage Transformer Ratio : 415/RT3/110/RT3V Burden : 50 VA Class : 0.5 Insulation Class :B Ref. Std. : IS 3156 Dimensions : L equal to 160, W equal to 140, H equal to 170 mm V. F. : 1.2 Continuous and 1.5 for 30 Secs Terminal Arrangement: NA MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. Resin Cast Single Phase Voltage Transformer Ratio :415/RT3/110/RT3V Burden : 50 VA Class : 3P Insulation Class :B Ref. Std. : IS 3156 Dimensions : L equal to 115, W equal to 110, H equal to 115 V.F. : 1.2 Continuous and 1.5 for 30 Secs Terminal Arrangement: NA MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd.
# Schedule Awarded To Bids Value 1 CURRENT TRANSFORMER(WOUND PRIMARY), BURDEN:15VA RATIO:60/1A,CLASS:1, INSULATION CLASS:B REF. STD:IS2705 FREQUENCY:50/60HZ,STC:3KA FOR1SEC, HSV/IL:0.66/3KV MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. TS ENTERPRISES 2 ₹1,295.64 2 L.T Resin Cast Rectangular Window Type CT Frequency:50/60 Hz Ratio :3200/1A Class: 0.5 Burden: 15VA ISF less than or equal to 5 ILV 0.72/3 kV. Ins Class: B Ref Std: IS16227-1 and 2 ID :210x40mm. Secondary Terminals on 40mm Side. Drawing No: LRRM-13-30-WOC Enclosed MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. KALPA ELECTRIKAL PVT LTD 2 ₹3,227.30 3 L.T Resin Cast Rectangular Window Type CTFrequency: 50/60 Hz Ratio: 3200/1AClass: PS(As per tender documents)MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. KALPA ELECTRIKAL PVT LTD 2 ₹5,133 4 L.T.Residual Voltage Transformer Three Phase Frequency:50/60 Hz Ratio: 415V/RT3//110V/3 Class: 3P(Residual Protection) Burden :50VA (Total) Voltage Factor : 1.2 Continuous./1.9 for 8 hrs. ILV 0.72/3 kV. Ins Class: B Vector Group/Connection :Star-open delta Primary:A,B,C,N Secondary:da,dn Ref Std IS16227-1 and 3 Type : Resin Cast.Terminals are terminated to terminal blocks. Drawing No. RPT-3PH-W-17-3448-04-Rev-01 Note: Three Nos. Single Phase Voltage Transformers mounted on common base MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. KALPA ELECTRIKAL PVT LTD 2 ₹6,844 5 L.T.Voltage Transformer Three Phase Frequency: 50/60 Hz Ratio: 415V/110V (Phase to Phase) ,415V/RT3//110V/RT3 (Phase to Neutral) Class: 0.5 Burden :50VA(Total) Voltage Factor: 1.2 Continuous./1.9 for 8 hrs. ILV :0.72/3 kV. Ins Class :B Vector Group/Connection :Star/Star(YNyN0) Ref Std: IS16227-1 and 3 Type : Resin Cast. Terminals are terminated to terminal blocks. Drawing No. RPT-3PH-W-17-3448-02-Rev-01 Note: Three Nos. Single Phase Voltage Transformers mounted on common base MAKE: Precise electrical / Kalpa electrikal pvt Ltd./Paras power engineering pvt. Ltd./Automatic Electric Ltd. KALPA ELECTRIKAL PVT LTD 2 ₹8,614
Show All 44 Schedules