Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹97.9 L
EMD Value
₹2.0 L
Closing Date
26 Dec 2019, 12:00 pmClosed
SUPRINTEDENT ENGINEER
SE RWD CIRCLE PITHORAGARH AT TAKANA
RAJKIYA INTER COLLAGE SENLEKH MI BHAWAN NIRMAN KARY AT GANGOLIHAT
2019_RES_21455_2
1340 Dated05-12-2019
Open Tender
Civil Works - Buildings
Item Rate
360 days
GANGOLIHAT
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Yes
EE RWD DIVISION PITHORAGARH
₹2.0 L
Yes
4 Jan 2020
7 Dec 2019
27 Dec 2019
7 Dec 2019
26 Dec 2019
7 Dec 2019
Amount
Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and rammingof bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth i levellingup with cement concrete 1:6:12(1 cement:6 coarse sand aggregate 20mm nominal size)at plinth level with 1:6 C/S mortar.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treated bars
Centring and shuttering including strutting, ropping etc. and removal of form for.
foundation,footing,bases of columns,etc.for mass concrete
Columns,Pillars,Piers,Abutments,Posts and Struts.
Suspended floors,roofs,landings,balconies and access platform.
Lintels,beams,plinth beams,girders,bressumers and cantilevers.
Backfilling in foundation Trenches as per Drawing and technical spesification cliuse 1108
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)
Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters 35mmtkick.
Structural steel work riveted,bolted or welded in built up se trusses and framed work,including cutting,hoisting,fixing in and applying a priming coat of approved steel primer all complete:
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
12 mm cement plaster of mix 1:6 C/F sand.
Cement concrete flooring 1:2:4 (1cement:2 coarse sand:4 grad finished with a floating coat of neat cement including cement slurry 40mm thick with 20mm nominal Size stone.
Providing and fixing glass strips in joints of metre terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.
Providing and fixing aluminium handles ISI marked anodised(anod less than grade AC10 as perIS:1868)transparent or dyed to req.125mm
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete.250x16 mm
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete.200x10 mm
Providing and fixing aluminium hanging floor door stopper ISI mar (anodic coating not less than grade AC 10 as per IS : 1868) transp required colour and shade with necessary screws etc. complete.Twin rubber stopper
White washing with lime to give an even shade New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work(two or more Coats)over & including priming coat with cement primer.
Finishing walls with Two coat Deluxe Multi surface paint system for interiors and exteriors including one coat of Special primer
Painting wood work with Deluxe Multi Surface Paint of required shade.Two or more coat applied @0.90ltr/10sqm over an under coat of primer applied @0.75ltr/10sqm of approved brand or manufacture. Manufacture
Painting steel work with Deluxe Multi Surface Paint of required shade.Two or more coat applied @0.90ltr/10sqm wiyhout priming coat of approved brand or manufacture.
Cement plaster skirting(up to 30cm height) with cement mortar 1:3(1cement:3coarse sand) finished with a floating coat of neat cement.18mm thick
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in 1:6 C/S Mortar.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes(thickness by the manufacturer) with water absorption’s less than 0.08% and IS: 15622 of approved make in all colours and shades,laid on 20mortar 1:4(1cement:4 coarse sand) including grouting the joints and matching pigments etc.,complete.Size of Tile 60x60 cm
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of thickness 4 mm
Providing and fixing white vitreous china water closet squatting pan (Indian type) :Orissa pattern W.C. pan of size 580x440 mm
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 ltr
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete32 mm dia.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 18.12.1 15 mm dia nominal bore
Providing and fixing brass stop cock of approved quality :15 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 18.18.1 15 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 18.49.1 15 mm nominal bore
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110mm bend
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm dia. Pipe
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 18.32.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 18.51.1 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 18.52.1 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 18.53.1 15mm nominal bore
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes 75 mm dia. conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
P & F of P.V.C. bend including all cost 75 mm
Making soak pit 2.5 m.diameter and 3.00 m. deep with 45*45 cm. dry honycomb brick masonary
Lab Block
Excavation in Soil with Dozer with lead upto 100 m Excavation for roadway in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 m, including trimming bottom and side slopes in accordance with requ
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and rammingof bottoms, lift upto 1.5 m, including getting out th
Providing and laying in position cement concrete of specified grade cost of centring and shuttering-All work upto plinth level 1:5:10 C/S 40mm Stone Ballast.
Providing and laying in position specified grade of reinforced ceme upto plinth level 1:1.5:3 (1cement:1.5 coarse sand:3 graded stone aggregate 20mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete Thermo-Mechanically Treated bars
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand
Centring and shuttering including strutting, ropping etc. and removal of form for.
Foundations, footings, bases of columns, etc. for mass concrete
Columns,Pillars,Piers,Abutments,Posts and Struts.
Lintel , Beam ,Plinth beam ,girders bressumers and cantilivers
Suspended floors, roofs, landings, balconies a access platform.
Structural steel work riveted,bolted or welded in built up se trusses and framed work,including cutting,hoisting,fixing in and applying a priming coat of approved steel primer all complete:
Brick work with F.P.S. bricks of class designation 75 in superstruct level upto floor V level in all shapes and sizes in 1:6 C/S Mortar.
12 mm cement plaster of mix 1:6 C/F sand
Cement plaster skirting(up to 30cm height) with cement mortar 1:3(1cement:3coarse sand) finished with a floating coat of neat cement.18mm thick
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Cement concrete flooring 1:2:4 (1cement:2 coarse sand:4 grad finished with a floating coat of neat cement including cement slurry 40mm thick with 20mm nominal Size stone.
Providing and fixing glass strips in joints of metre terrazo/ cement concrete floors. 40 mm wide and 4 mm thick. 2.5 time of flooring
Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters 35mmtk
Providing and fixing panelled or panelled and glazed shutters for doors , windows and clerestory window including ISI marked black enamelled M.S. but hinges with necessary screws including panelling which will be paid for separately. 30 mm thick for frame work
Providing and fixing panelled or panelled and glazed shutters for doors , windows and clerestory window including ISI marked black enamelled M.S. but hinges with necessary screws including panelling which will be paid for separately. 30 mm thick for panelling work
Providing and fixing aluminium handles ISI marked anodised(anod less than grade AC10 as perIS:1868)transparent or dyed to req.125 mm
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete 200x10 mm
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete.250x16 mm
Providing and fixing aluminium hanging floor door stopper ISI marked required colour and shade with necessary screws etc. complete.single rubber stopper
White washing with lime to give an even shade New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work(two or more Coats)over & including priming coat with cement primer.
Finishing walls with water proofing cement paint of required shade new work ( Two or more coats applied @ 3.84 kg/10 sqm)
Painting wood work with Deluxe Multi Surface Paint of required shade.Two or more coat applied @0.90ltr/10sqm over an under coat of primer applied @0.75ltr/10sqm of approved brand or manufacture. Manufacture
Random Rubble Masonary laid dry in breast wall,retaining wall, parapets,scupper etc. Including supply of all materials,labour,t & p& royality etc,required for proper complition of work.(As per PWD Uttarakhand specifications)
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. .(As per PWD Uttarakhand specifications)
Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
s/f of sign board & photography L/S
M/S VIKRAM SINGH PAL
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .