| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC | ₹4.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹46,924−₹4.2 L (89.9%)Rejected-AOC | ₹46,924−₹4.2 L (89.9%) | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | P ANIL KUMAR L2 | P.Sreekumar P.S.Electricals L1 |
|---|---|---|---|---|---|
| 1.00Maintenance and repair | |||||
| 1.00 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group A | 18 | point | 1,103.22 ₹19,857.96 | 1,050 ₹18,900 Lowest |
| 1.00 | 1.8.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point
with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A | 2 | point | 1,078.89 ₹2,157.78 | 1,025 ₹2,050 Lowest |
| 1.00 | OD105690/2025-2026:Supply and fixing of 1200 mm LED Tube poly carbonate body 1200 mm, T8 I, 1X 18 w with nominal system level lumen package of 2100 Lumen having efficiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc. The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification, as required. Philips make master tube | 75 | each | 749.66 ₹56,224.5 Lowest | 800 ₹60,000 |
| 1.00 | OD100170/2025-2026:Supply of 1200 mm LED Tube poly carbonate body 1200 mm, T8 I, 1X 18 w with nominal system level lumen package of 2100 Lumen having efficiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc. The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification, as required. | 25 | each | 660.39 ₹16,509.75 Lowest | 700 ₹17,500 |
| 1.00 | OD100172/2025-2026:Supply, conveyance, installation, testing and commissioning of cast aluminum stove enameled elliptical shaped BULK HEAD fittings suitable for B22 LED Bulb, fixed directly on wall including cutting necessary holes, giving connections with the extended original wiring, making good the damages, colour washing etc as required. | 10 | each | 512.55 ₹5,125.5 Lowest | 550 ₹5,500 |
| 1.01 | OD100174/2025-2026:Supply of 7W /9W LED Bulb suitable for B 22 type holder and 230/240 volt AC 50 Hz power supply( Philips or its Equivalent standard) | 30 | each | 108.41 ₹3,252.3 | 107 ₹3,210 Lowest |
| 1.01 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | 50 | each | 2,077.12 ₹1,03,856 | 2,050 ₹1,02,500 Lowest |
| 1.01 | OD100171/2025-2026:Supply of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | 18 | each | 1,846.09 ₹33,229.62 Lowest | 1,850 ₹33,300 |
| 1.01 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | 100 | metre | 103.35 ₹10,335 | 100 ₹10,000 Lowest |
Tender Value
₹5.1 L
EMD Value
₹12,710
Closing Date
17 Sept 2025, 6:00 pmClosed
AEE
pwd electrical sub division Tvpm
GENERAL-Running maintenance contract to Electrical Installations in the RHS Quarters at Melarannoor, Poojappura, Tvpm-2025-26-Electrical Maintenance-General Electrical Work
2025_PWD_788410_2
ESDT/ET-103/2025-26
Open Tender
Electrical Works
Item Rate
180 days
pwd electrical sub division Tvpm
please refer tender documents
6 documents required · 6 mandatory
₹1,125
₹12,710
16 Oct 2025
9 Sept 2025
19 Sept 2025
9 Sept 2025
17 Sept 2025
9 Sept 2025
Amount
Maintenance and repair
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.8.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
OD105690/2025-2026:Supply and fixing of 1200 mm LED Tube poly carbonate body 1200 mm, T8 I, 1X 18 w with nominal system level lumen package of 2100 Lumen having efficiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc. The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification, as required. Philips make master tube
OD100170/2025-2026:Supply of 1200 mm LED Tube poly carbonate body 1200 mm, T8 I, 1X 18 w with nominal system level lumen package of 2100 Lumen having efficiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc. The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification, as required.
OD100172/2025-2026:Supply, conveyance, installation, testing and commissioning of cast aluminum stove enameled elliptical shaped BULK HEAD fittings suitable for B22 LED Bulb, fixed directly on wall including cutting necessary holes, giving connections with the extended original wiring, making good the damages, colour washing etc as required.
OD100174/2025-2026:Supply of 7W /9W LED Bulb suitable for B 22 type holder and 230/240 volt AC 50 Hz power supply( Philips or its Equivalent standard)
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD100171/2025-2026:Supply of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
1.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
1.23.8:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.Bell push
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD100169/2025-2026:Supply and renewing of Piano type Step socket type fan regulator in place of the existing faulty ordinary<br>regulator using mechanized cutting of holes in the existing hylem sheet and giving connections etc required
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
OD100162/2025-2026:Supply 2.5 mfd. Ceiling Fan Capacitor, ISI marked etc as required
OD100165/2025-2026:Supply and replacement of Rubber Shackle and Cotter pin for Ceiling Fan
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD100168/2025-2026:SITC of 32, HRC Fuse Base with HRC Fuse link
OD100167/2025-2026:Supply and fixing 20mm normal size 1way terminal rigid PVC junction box with lid etc as required
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
90.12.5.28:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 35 sq mm
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.10.4:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation77/63 mm or nearest size
9.3.18:Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm
OD105493/2025-2026:Supplying of channel iron 75 mm X 40 mm X 3 mm (3.5 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes and painting with primer and finished paint as required .
OD105618/2025-2026:Supplying and fixing 200 A, 415 V lug type Porcelain Kitkat fuse unit
OD105623/2025-2026:Supplying and fixing 100 A, 415 V lug type Porcelain Kitkat fuse unit
OD105463/2025-2026:Supplying and fixing the following neutral links - 200 A, 415 V, 2 way neutral link mounted on metal frame/ channel
OD105632/2025-2026:Supplying and fixing the following neutral links - 100 A, 415 V, 2 way neutral link mounted on metal frame/ channel
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
OD100163/2025-2026:Urgent maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan ,checking all electrical connection in the DB and switch board.
OD100175/2025-2026:Painting letters or figures of the follwing sizes with enamel paint as identfication mark to SB, DB, panel board etc as required
OD100166/2025-2026:Charges for Painting of Panel Board in installed position with one or more coats of paintingwith synthetic enamel paint of approved brand and Colour , including checking all switches , metes, fuses inter connections etc and tightening the connections, attending petty repairs etc., as required(measurement taken by whole sheet area )
OD100164/2025-2026:Charges for dismantling the existing EI, complete, making good the damages of walls and conveying the dismantled materials to section store.
P ANIL KUMAR (BID ID -2343275)
Bidder Name
P ANIL KUMAR
P.Sreekumar P.S.Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1314972.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .